SCADAPack 530E 535E. remote Programmable Automation Controller



Similar documents
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Application/Connection Examples

securityprobe5es -X20

IntesisBox Modbus Server Fidelio IP

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

securityprobe 5E Standard

How To Run An Nport I5000A Device Server

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Compatible with all of the Ravica range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

TX2123 RS485 TO ETHERNET ADAPTOR

Z-TWS4. Multifunction Straton / LINUX Controller.

IntesisBox Modbus Server SAMSUNG Air Conditioners

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

R-Win. Smart Wireless Communication Management System

Designed for the needs of automation, telecommunications, remote supervision, and monitoring

Foxboro Evo Process Automation System


Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Optimize your simple machines... Modicon M218 Selection Guide

1 Mi kołaj Z Mik ar ołaj Z zyc arzy ki cki

MICROLOGIX PROGRAMMABLE CONTROLLERS SELECTION GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

IntesisBox KNX Modbus TCP master

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

Telephone- and leased line modem for industrial applications TD-36

Rack mounted telephone- and leased line modem for industrial applications

Straton and Zenon for Advantech ADAM Copalp integrates the straton runtime into the ADAM-5550 device from Advantech

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output

Electronic Control Devices The European Product Catalogue 2007

WHITE PAPER. SCADA Systems

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

PCS0100en Persy Control Services B.V. Netherlands

Electronic Control Devices The European Product Catalogue 2007

Foxboro Evo Process Automation System

Modular I/O system Rugged Modular I/O System Solutions EN certified for railway applications

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

Modbus Server SAMSUNG Air Conditioners

SHEET. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

User manual Compact Web PLC WP240 series IEC-line

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

FLYPORT Wi-Fi G

TK800-Series Industrial GPRS / UMTS / LTE Router

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

TAC I/NETTM MR-AHU-HP. Application Specific Controller

NETWORK ENABLED EQUIPMENT MONITOR

TAC I/NETTM. Intrusion Alarm System

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

COMPUTING INDUSTRIAL EMBEDDED RUGEDIZED 19 INDUSTRIE PC

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Cisco 7816-I5 Media Convergence Server

Modicon M340 The all-in-one PAC

EA7-T8C EA7-T10C EA7-T12C EA7-T15C

S-series SQ Controller

Remote Monitoring Unit SC8100. Monitoring Unit SC8100

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

Vibration analysis and monitoring Compact. Powerful. Modern technology.

MVME162P2. VME Embedded Controller with Two IP Slots

38 Series - Relay interface modules A

38 Series - Relay interface modules A

3500/22M Transient Data Interface

Technical Information POWER PLANT CONTROLLER

Environmental data Temperature: -20 C to +55 C (Operating) -55 C to +85 C (Storage) Humidity: 0 95%

think ahead TRILITHIC One-box Integrated Solution Flexible & Expandable Open Architecture IP-Based Alerting Protocols

Job Aid Pre-Installation Information S8500 Media Server

DCS Series 1 kw, 1.2 kw, & 3 kw

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

IntesisBox KNX Modbus RTU master

Unidirectional Transmitter/ Receiver Units Introduction

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide

Application Server V240 Platform

Remote monitoring & control solutions for cathodic protection rectifier

Alcalde # 1822 Col. Miraflores C.P Guadalajara, Jal. Mexico MX 01 (33) y USA 001 (619) (San Diego, CA.

NAFEM Gateway User s Manual For Watlow part numbers NGW , NGW , NGWC , NGWC

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Communication standards and Carel solutions

In-Sight Hardware specifications

ABB RTU560A Series CMU & Modules

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

M2M I/O Modules. To view all of Advantech s M2M I/O Modules, please visit

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

How To Set Up A Modbus Cda On A Pc Or Maca (Powerline) With A Powerline (Powergen) And A Powergen (Powerbee) (Powernet) (Operating System) (Control Microsci

Indoor / Outdoor Antenna

TAC I/NETTM. Process Control Unit

1 Serial RS232 to Ethernet Adapter Installation Guide

A-307. Mobile Data Terminal. Android OS Platform Datasheet

NX safety stand-alone

applicomio Profibus-DP

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

WP WinPAC-8x49 Series (WP-8149/8449/8849) is the new generation WinCE based InduSoft PAC (Programmable Automation Controller).

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Transcription:

SCADAPack 530E 535E remote Programmable Automation Controller

1 With the SCADAPack 500E range, Schneider Electric introduces the first ever remote Programmable Automation Controller (rpac). This data sheet presents the first two models of that new range, the SCADAPack 530E and the SCADAPack 535E. The ARC Advisory Group has defined the rpac as a whole new way to look at remote site automation. An rpac combines the power of a PAC with the versatility of an RTU. The SCADAPack 500E rpac is a platform that dramatically increases performance (execution speed, connectivity, number of remote/ local I/O), adheres to open standards, and can operate in the harsh demands of a remote environment. SCADAPack 500E provides: Open standard telemetry protocols such as DNP3 level 4 with Security Suite (Secure Authentication and/or Data Encryption) and IEC 60870-5-101/-104 Open standard industrial protocols such as Modbus RTU, Modbus TCP and DF1 Open standard IEC 61131-3 programming environment Data concentrator for any DNP3, Modbus or DF1 devices Up to 29 active SCADA masters, up to 100 remote/local slave devices and up to 100 remote DNP3 devices in peer-to-peer mode Remote management suite (ability to amend configuration, modify programs and update firmware remotely, using open standard DNP3) Up to 515 internal digital/analog inputs/outputs 1ms resolution time-stamped digital inputs, 30ms sampled analog inputs with 16-bit ADC 3 Ethernet and 4 Serial ports, 1 embedded 3G modem, 1 USB device port for configuration 1 USB host port for external storage (memory stick up to 32GB) Tool-free DIN rail mounting system Withstands 15g acceleration IP2x terminal blocks Operation from 40 to +70 C ( 40 to +158 F) Compact form factor

Specifications 2 Controller Processor Memory Event Logging Capacity (events) Database Capacity (points) Data Concentrator capacity (points) Data Concentrator capacity (devices) File System Typical Storage Communications Serial Ports: Serial1, Serial2 Serial Ports: Serial3, Serial4 Embedded Wireless Serial Protocols Ethernet Ports: Eth1, Eth2, Eth3 IP Protocols Master - Slave capability USB Device USB Host General Logic control I/O terminations Dimensions Packaging Environment General characteristics SPEAr 1380 32-bit dual-core Cortex A9 microcontroller, up to 600MHz 128MB NAND FLASH, 128MB DDR3 RAM Non-Volatile RAM CMOS SRAM with lithium battery retains contents for 2 years with no power 40,000 (this number decreases if the database is greater than 10,000 points) Up to 20,000 (this number decreases if the event pool is above 7,000 events) Approximately 15,000 Approximately 100 Internal: 10 MB; External: 32 GB (on optional memory stick) RS-232 port, 8-pin modular RJ45 jack, full or half duplex with RTS/CTS control and operator interface power control, supports baud rates up to 115,200 bps. Rated to ±15kV (IEC 61000-4-2, Air Discharge) static protection RS-232 port, 8-pin modular RJ45 jack, full or half duplex, or RS-485 port, 2-wire, half-duplex, supports baud rates up to 115,200 bps In RS-232 mode, rated to ±15kV (IEC 61000-4-2, Air Discharge) static protection The controller board is fitted with Socket Modem support, for future use DNP3 level 4 slave/master and peer-to-peer, IEC 60870-5-101 slave, Modbus slave/master, DF1 master 8-pin modular RJ45 jack, 10/100 Mbps UTP (10/100Base-T), transformer isolated DNP3 level 4 in TCP Master/Slave, UDP Master/Slave and peer-to-peer, IEC 60870-5-104 Slave, Modbus/TCP Server, Modbus/TCP Client, Modbus RTU in TCP Client NTP Client/Server, Telnet Server, FTP Server, BOOTP Server, Can simultaneously report to up to 29 independent masters (3 in DNP3, 2 in IEC 60870-5-5-101/104, 20 in Modbus TCP and 4 in Modbus RTU ) and connect to up to 100 remote devices in DNP3 peer-to-peer. As a data concentrator it can manage up to 100 local or remote DNP3 slaves, and up to 100 local slaves communicating with Modbus RTU, Modbus TCP or DF1 serial. USB 2.0 compliant B -type receptacle, for local configuration USB 2.0 compliant A -type receptacle, supports USB devices up to 32GB (specific memory sticks supported) IEC 61131-3 SCADAPack Workbench programming suite (LD, ST, FBD & SFC) SCADAPack 530E: 11-pole connector, 0.0810...3.31mm 2 (28...12 AWG), solid or stranded SCADAPack 535E: 5, 6, 7, 9, 11-pole connectors, 0.0810...3.31mm 2 (28...12 AWG), solid or stranded SCADAPack 530E: 150.5mm (5.93 ) wide, 134.8mm (5.31 ) high, 74.9mm (2.95 ) deep SCADAPack 535E: 150.5mm (5.93 ) wide, 182.3mm (7.18 ) high, 86.5mm (3.41 ) deep Corrosion resistant zinc-plated steel with black enamel paint -40 C (-40 F) to 70 C (158 F) operating, -40 C (-40 F) to 85 C (185 F) storage 5% RH to 95% RH, non-condensing Shock & Vibration IEC 60068-2-27 (tested up to 15g), IEC 60068-2-6 Warranty 3 years on parts and labor

Specifications 3 Power Supply Rated Voltage General characteristics 12...30 Vdc, 5W typical. Limit voltage: 11.5...32 Vdc; turn on voltage: 10...11.5 Vdc; turn off voltage: 9...10 Vdc Maximum Power SP530E + 4 x 6601 expansion IO modules + USB: 8.7W Power Requirements SP530E (Controller) 3.7 W SP535E (Controller with integrated IO) 4.8 W 6601 (Expansion IO) 1.1 W USB (5V at 100mA) 0.6 W Serial port (5V at 250mA) 1.5 W For analog output power requirements see the Analog Output specifications. Voltage input Power Consumption (W) 530E 535E 535E + 6601 535E + 2 x 6601 535E + 3 x 6601 11.5V 3.0 4.1 5.2 6.3 7.4 13.8V 3.0 4.1 5.2 6.3 7.4 24V 3.4 4.5 5.6 6.7 7.8 30V 3.7 4.8 5.9 7.0 8.1 Certifications EMC and radio frequency General safety UL 508 Hazardous locations FCC 47 CFR Part 15, Subpart B ICES-003 Issue 5 August 2012 CE and RCM markings ccsaus Non incendive Electrical Equipment for use in Class I, Division 2, Groups A, B, C and D IECEx/ATEX Class I, Zone 2

Specifications 4 Controller board (530E and 535E) Digital and Analog Inputs/Outputs Digital Inputs 2, 12 24 Vdc Turn on voltage: 8 Vdc (minimum), Turn off voltage: 4 Vdc (maximum) Over-voltage tolerance: 150% sustained over-voltage without foreseeable damage DC input current: 0.4 ma at 12 Vdc, 0.8 ma at 24 Vdc Time stamping: 10 ms Ground return connected to Chassis Ground Digital Output 1, Sinking MOSFET output, rated 30V, 0.5A, ground return connected to Chassis Ground Internal power monitor Power input - analog input and low indication, onboard lithium battery - low indication Internal temperature monitor Controller temperature range -40 C +75 C (-40 F...+167 F) I/O board (535E and 6601 standalone module) Analog Inputs 6, dipswitch-configurable to 4...20 ma, 0...20 ma, 1...5 V, or 0...5 V Uni-polar, differential, voltage or current Resolution: 24-bit ADC (16-bit over the measurement range) Accuracy: ±0.1% of full scale at 25 C (77 F), ±0.2% over temperature range Isolation: 250 Vac isolation from channel to channel and from rpac logic and chassis Input Resistance: 250 Ω or 800 kω in current/voltage configurations Under range: 4...20 ma measures to 0 ma Common Mode Rejection: -80dB (50/60Hz) 30 ms sampling rate Analog Outputs 2 (optional), 0...20 ma, 4...20 ma, voltage output may be accomplished with external precision resistor Uni-polar Resolution: 12-bit over 0...20 ma range Accuracy: ±0.15% at 25 C, ±0.35% of full scale over temperature range Response Time: less than 10 µs for 10% to 90% signal change Power Supply: 12 30 Vdc, external Power (Current) Requirements: 10 ma plus up to 20 ma per output Isolation: transformer, 500 Vdc maximum to RTU logic and chassis Load Range: 12 Vdc: 0 475Ω, 24 Vdc: 0 1075Ω, 30 Vdc: 250 1375Ω Logic End-Of- Scan to Signal Update Latency: less than 10 ms (typically 5...8 ms) Status & Reporting: Open Loop status, output value poll Controls: Direct Operate, Select Before Operate Digital Inputs 16, 12 24 Vdc Turn on voltage: 9 Vdc (minimum), Turn off voltage: 4 Vdc (maximum) Over-voltage tolerance: 150% sustained over-voltage without foreseeable damage DC input current: 0.9 1.2 ma at 12 Vdc, 2.1 2.4 ma at 24 Vdc Time stamping: 1 ms Sequence of Event Isolation: in 2 groups of 8. Isolation from RTU logic and chassis: 1000Vac/1500Vdc Digital Outputs 8, relays (2 Form C, 6 Form A) Form C: SPDT, separate Normally Open/Normally Closed/Common Form A: Normally open, one common Isolation: 500 Vac minimum to RTU logic Maximum Switching Voltage: 30 Vdc or 25 Vac Maximum Switching Load: 60 W or 50 VA (2A) Status & Reporting: Individual relay pole feedback to software, output state poll Controls: Direct Operate, Select Before Operate, Trip/Close, Latch, Pulse Counter Inputs 8, shared with digital input channels 1 to 4: 0 1.5kHz, 5 to 8: 0 150Hz. Additional I/O I/O Expansion Supported modules: 6601 external module Maximum number of modules per unit: SCADAPack 530E: 16 (*) SCADAPack 535E: 15 (*) (*): to reach this limit, additional power supply modules are required

Model 5 SCADAPack 530E/535E Model TBUP530 TBUP535 E A B C D Select: Controller SCADAPack530E, 32-bit controller, Dual Core SCADAPack535E, 32-bit controller, Dual Core, comes with additional I/O Select: Platform SCADAPack E Firmware (Configuration Software included), executes two IEC 61131 kernels, Workbench required Select: SCADA Security None AGA-12 Encryption for DNP3 (Security Administrator application required) DNP3 Secure Authentication SAv2 (Security Administrator application required) DNP3 Secure Authentication with AGA-12 (Security Administrator application required) Select: Protocol Option 5 DNP3 Serial/IP mstr/slave/peer-to-peer, IEC 60870-5-101/104 Slave, Modbus RTU/TCP mstr/slave, TCP/IP, DF1 mstr Select: License Option 6 Full DNP3 Data Concentrator License, Multiple DNP3 Master License (up to 3 Masters) A Select: Analog Inputs P530: None P535: adds 6, shipped selectable as 0-20mA or 4-20mA B P535 only: adds 6, shipped selectable as 0-5V or 1-5V A Select: Digital Inputs/Outputs P530: 2 Digital Inputs (12/24V), 1 Digital Output (open collector) B P535: 16 Digital Inputs (12/24V) and 8 Dry Contact Relay outputs (6 Form A, 2 Form C) 0 None Select: Analog Outputs 1 P535 only: 2 channel Analog Output option, shipped selectable as 0-20 ma or 4-20mA, external DC supply 0 None S U Select: Integrated Communication Interfaces Select: Certifications With FCC, UL508, CE marking and RCM Adds ccsaus Nonincendive Electrical Equipment for use in Class I, Division 2, Groups A, B, C and D X Adds IECEx/ATEX Class I, Zone 2 I/O Expansion Modules (Supported by SCADAPack 530 & 535 Controllers only) Part No. TBUX297583 TBUX297584 TBUX297585 TBUX297586 I/O expansion and distributed architecture Expansion Modules (complete the following part numbers with S, U or X depending on certification required) Model 6601-20mA, 16 D/I 12-24 volts, 10 Dry Contact relay O/P, 6 config. A/I (0/4-20mA) Model 6601-5V, 16 D/I 12-24 volts, 10 Dry Contact relay O/P, 6 config. A/I (0/1-5V) Model 6601-20mA, 16 D/I 12-24 volts, 10 Dry Contact relay O/P, 6 config. A/I (0/4-20mA), 2 A/O (external DC supply) Model 6601-5V, 16 D/I 12-24 volts, 10 Dry Contact relay O/P, 6 config. A/I (0/1-5V), 2 A/O (external DC supply) 1. Depending on the options chosen (with or without the future socket modem), SCADAPack 535E embedded DC supply can power either two (2) or four (4) 6601 IO expansion modules. When more 6601 IO expansion modules are required in any of these two configurations, then it is necessary to use one of our power supply extensions (one unit can power up to 8x 6601 modules). 2. SCADAPack 535E can be used as a Remote I/O master, managing up to 15 SCADAPack ES slave units: SCADAPack 535E automatically downloads the corresponding configuration into these slave devices (which is very useful when replacing devices, as the operator does not have to do any firmware setting). Schneider Electric Telemetry & Remote SCADA Solutions 415 Legget Drive, Suite 101, Kanata, Ontario K2K 3R1 Canada Direct Worldwide: 1 (613) 591-1943 Fax: 1 (613) 591-1022 Toll Free within North America: 1 (888) 267-2232 www.schneider-electric.com 2014 Schneider Electric. All Rights Reserved. Schneider Electric is a trademark and property of Schneider Electric SE, its subsidiaries and affiliated companies. All other trademarks are the property of their respective owners - September 2014 Part Number TBULM08038-03 v028 Document number 0100BR1431