Unidirectional Transmitter/ Receiver Units Introduction

Similar documents
Wireless Connectivity Solutions

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Electronic Control Devices The European Product Catalogue 2007

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Telephone- and leased line modem for industrial applications TD-36

Electronic Control Devices The European Product Catalogue 2007

Rack mounted telephone- and leased line modem for industrial applications

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

SR450 RECEIVER OPERATING INSTRUCTIONS

Quick Connect. quick - simple - efficient.

Regards from the Team at Rheology Solutions.

Bluetooth to Serial Adapter

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

WIRELESS INSTRUMENTATION TECHNOLOGY

M2M I/O Modules. To view all of Advantech s M2M I/O Modules, please visit

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

3500/22M Transient Data Interface

IntesisBox Modbus Server Fidelio IP

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Model: DC-A2IO Advanced HVAC Controller

FOM-5A, 6A. Asynchronous Fiber Optic Modem

IntesisBox KNX - LON

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Indoor / Outdoor Antenna

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

IntesisBox KNX Modbus TCP master

LDG DTS-4/4R Desktop Coaxial Switch / Remote

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Intelligent RS-485 I/O expansion unit: RU-87Pn Series

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

KNX Panasonic Air Conditioners

Waveguide Access Point WGA631. Product Guide

IntesisBox KNX Modbus RTU master

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

ABB RTU560A Series CMU & Modules

How To Use A Ds340 (Dsp)

O C M III. Open Channel Flow Monitor

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

GSM Voice Auto Dialer & SMS Sender JC-999

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Microcor Wireless Transmitter (MWT)

User manual Compact Web PLC WP240 series IEC-line

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

DPI 260 SERIES: Digital Pressure Indicators

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

PRO 5000 CPE 1D Quick Installation Guide

IntesisBox KNX LG Air Conditioning

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

Product Specifications

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Loop-IP6702 TDMoEthernet

TDMoEthernet. Description

How To Use A Sound Card With A Subsonic Sound Card

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers

Wireless Solutions for Environmental Monitoring and Process

FX07 Field Controller

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Rosemount 333 HART Tri-Loop

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

Rosemount 333 HART Tri-Loop

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

This Antenna Basics reference guide includes basic information about antenna types, how antennas work, gain, and some installation examples.

Wireless Connectivity

F2400 FOM II Series Fiber Optic Modem Technical Manual

WEATHER STATION FOR SOLAR FARM MONITORING

1701/22 FieldMonitor Management Interface Module

Long Reach PoE over Coaxial Extender Kit

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

A RF18 Remote control receiver MODULE

Turbo X channel UHF true diversity

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

DTS/DRS-1000RV. Owner s Manual. DTS-1000RV: DVI/HDMI or VGA, Audio, RS-232C Transmitter Extender

TAC I/NETTM. Process Control Unit

TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE

IntesisBox Modbus Server SAMSUNG Air Conditioners

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Installation Instructions. Wireless Adapter/Repeater. Introduction Rev C

Best Practices Guide for Obvius Data Acquisition Products

airmax Wireless Broadband CPE Datasheet Models: AG-HP-2G16, AG-HP-2G20, AG-HP-5G23, AG-HP-5G27 High Performance, Long Range Integrated InnerFeed CPE

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

SPECIAL SPECIFICATION 6819 Wireless Ethernet Microwave Radio

AP60. 9 Wireless. Wireless-b/g/n Long Range PoE Access Point. Wireless-b/g/n Long Range Radio. Passive PoE and 4-LAN Ports. IP Finder Management 4 LAN

Antenna Trainer EAN. Technical Teaching Equipment INTRODUCTION

Loop-V4300 MINI DACS E1/ T1 CONVERTER

Smart Wireless Devices. LAN-WMBUS-G Wireless MBUS, high performance Temperature, Humidity and Pulse counting device.

MLC TM Maximum Productivity and Versatility for Control without Compromise!

LT-82 Stationary IR Transmitter

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

HDO700 P FIBRE OPTIC TRANSMITTER

Transcription:

Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created as output signals, or output via serial link or field-bus. Weidmuller units have the ability to form sophisticated peer-to-peer networks, with event-reporting messaging to optimize wireless density. Weidmuller products are designed for high reliability operation on open licensefree radio bands. WI-I/O 9-L Unidirectional Transmitter/Receiver Units The Unidirectional range of products is suitable for connecting to a single sensor or group of sensors and provides an economical solution for remote monitoring systems. The Unidirectional L products can also be used in more complex networks as signal transmitters or receivers. Frequency hopping spread spectrum 902-928 MHz license-free USA/Canada/Mexico Configurable sub-bands license-free South America, Australia/NZ, Asia, Europe Applications Wireless connection of flowmeters or energy meters Monitoring storage tanks Monitoring cathodic protection on pipelines Wireless alarms from power reticulation fault relays Transmitter unit Input-only transmitter unit - two digital/pulse inputs, one analog input and one thermocouple mv input Transmits to Receiver unit as a matched pair where the input signals are re-created as output signals, or can transmit to a Multi-I/O or Gateway unit Class 1 Div 2 hazardous areas approval C US Up to 3000 wireless units per network External inputs plus internally calculated values - analog setpoint status, pulse count, power supply voltage input 20 to +100mV with cold-junction compensation and linearization for J, K or T-type Setpoints status generated by comparing analog input to high and low setpoints inputs can also be used as pulse count inputs Power supply 9 30VDC, measured and available as a transmitted variable 24VDC analog loop supply internally provided RS232 Configuration port Features Matched transmitter/receiver pair of modules, or individual transmitter and receiver units Peer-to-peer communications. Exception reporting. Reliable self-checking messages. Highly secure data encryption. Multi-hop repeater functions - up to 5 intermediate units can be configured in any input-output link Factory configured as a matched Transmitter/Receiver pair or user-configurable with E-Series Windows configuration program 16

Receiver unit Output-only receiver unit - three digital contact outputs and one analog output Receives radio commands from Transmitter unit as a matched pair where the input signals are re-created as output signals, or can receive commands from a Multi-I/O or Gateway unit Class 1 Div 2 hazardous areas approval C US Up to 3000 wireless units per network Power supply 9 30VDC; 24VDC analog loop supply internally provided Communications failure indication and configurable output Outputs can be configured as retained or reset (fail-safe) on communications failure LED indication of radio signal strength RS232 Configuration port Transmitter/Receiver Unit Ordering Information Unit Description WI-I/O 9-L-T Wireless Transmitter (900 MHz) WI-I/O 9-L-R Wireless Receiver (900 MHz) WI-I/O 9-L-P1 900 MHz Wireless Transmitter/ Receiver Pair with two -2 db Dipole Antennas WI-I/O 9-L-P2 900 MHz Wireless Transmitter/ Receiver Pair with two 0 db Dipole Antennas Dimensions WI-I/O 9-L-T OK D1 D2 SP TX AZ SET 6720005005 PG 3.9" (100 mm) 4.7" (120 mm).09" (23 mm) General Frequency: frequency hopping spread spectrum, Sensitivity: line-of-sight range 20 miles (4W ERP - effective radiated power ), 15km ( ERP); 3000 ft /1000 m in obstructed industrial environments; radio transceiver or gateway units Antenna Connector: SMA connector for antenna or coaxial cable connection Temperature: -40 to 60 C / -40 to 140 F Humidity: Regulatory Approvals: EMC compliant 89/336 EEC, EN 301 489, AS3548, FCC Part 15, Approved to FCC Part 15.247, RS210 Housing: DIN-rail thermo-plastic enclosure 100 x 22 x 120 mm / 3.9 x 0.9 x 4.7 inches Transmitter Unit: Power/OK, radio TX, DIN1, DIN2, analog set-point status Receiver Unit: Power/OK, radio RX, DO1, DO2, DO3, communications fail LEDs also used to provide radio signal strength indication Input Source Function external status Pulse Total external count external analog external analog Set Point internal status Supply Voltage internal analog Input values transmitted as per WIB-net (see page 8) protocol - exceptionreporting on signal change, and update time. Up to 5 repeater addresses, configurable. 17

/ Pulse Inputs Two inputs, suitable for voltage-free contacts / NPN, or voltage input 0-1 VDC on / >3 VDC off pulse input max. rate 10 Hz, 50 msec on time. Pulse counted as 16-bit register. Inputs Floating differential input, 16-bit, Inputs Millivolt (-20mV to +100mV), J, K, or T type linearization Accuracy better than 1 C RS232 RJ45 female DCE, used for configuration LED Indication Transmitter Unit Power/OK, radio TX, DIN1, DIN2, analog set-point status Receiver Unit Power/OK, radio RX, DO1, DO2, DO3, communications fail LEDs also used to provide radio signal strength indication Normal Supply: 9-30 VDC, power consumption @12VDC - receiver normal 70mA, max. 250mA Transmitter normal 70mA, transmitting max. 600mA loop supply internally generated, 24VDC 35mA Internal monitoring of supply voltage may be transmitted as an input (transmitter unit only) Set-point Status High and low set-points generate internal digital statusset-point status sets (on) when analog value < low setpoint and resets (off) when analog value > high set-point. Status is transmitted as per digital input, set-point values are set via the front panel rotary switch or configuration software. Separate set-points for (4-20 ma), thermocouple and supply inputs are configurable Receiver Outputs Outputs Three relay contact outputs, 260V 1A Outputs, source output, 12-bit, 0.1% Communication Failure Internal status based on configurable time-out value Comms-fail status can be configured to a local output Fail-Safe On comms-fail, outputs user-configurable as retained last correct value or reset (fail-safe) Configuration and Diagnostics Factory configuration transmitter/receiver matched pair, AI to AO, 2DI to 2DO, SP status to DO3 via RS232 - RJ45 cable User configuration via serial port. Unidirectional units can be configured to network with multi-i/o and gateway units. Diagnostics features: read input values, write output messages 18

Unidirectional Transmitter/Receiver Units 900 MHz WI-I/O 9-L-T Transmitter WI-I/O 9-L-R Receiver C C1D2 US Technical Data Pulse floating differential input: Accuracy Receiver Outputs Comms-Fail Fail-safe Power consumption @12VDC loop supply internally generated Internal monitoring of supply low voltage status Power consumption increases for pulse inputs > 10Hz. General Data Operating Temperature Humidity EMC Standards Mounting LED indication: Transmitter Unit LED indication: Receiver Unit frequency hopping spread spectrum Transmit power Maximum line of sight range Antenna connector Dimensions mm (in) Configuration Diagnostics Ordering Data Accessories: DB9 Female-RJ45 Serial configuration cable two inputs, suitable for voltage free contacts / NPN, or voltage input 0-1 VDC on / >3 VDC off max rate 10 Hz, 50 msec on time. Pulse counted as register. Receiver 100mA, Transmitter 40mA quiescent, during radio transmission (50 msec) 300mA RS232 RJ45 female DCE, used for configuration Power/OK, Radio TX, DIN1, DIN2, Setpoint status 20 miles (4W ERP), 15km ( ERP); 3000 ft / 1000 m in obstructed industrial environments. Radio repeater units. Each transmission may be configured to be sent 1 to 5 times. User configuration via serial port. Unidirectional units can be configured to network with Multi-I/O and Gateway units. Diagnostics features - read input values, write output messages. WI-I/O 9-L-T 6720005005 WI-CSER-RJ45 6720005108 Receiver 100mA, Transmitter 40mA quiescent, during radio transmission (50 msec) 300mA RS232 RJ45 female DCE, used for configuration Power/OK, Radio RX, DO1, DO2, DO3, Communications Fail. 20 miles (4W ERP), 15km ( ERP); 3000 ft / 1000 m in obstructed industrial environments. Radio repeater units. Each transmission may be configured to be sent 1 to 5 times. User configuration via serial port. Unidirectional units can be configured to network with Multi-I/O and Gateway units. Diagnostics features - read input values, write output messages. WI-I/O 9-L-R 6720005006 WI-CSER-RJ45 6720005108 19

Unidirectional Transmitter/Receiver Units 900 MHz WI-I/O 9-L-P1 Set - 1 Transmitter, 1 Receiver WI-I/O 9-L-P2 Set with 2 WI-ANT-DPL-0-8 C C1D2 US Technical Data Pulse floating differential input: Accuracy Receiver Outputs Comms-Fail Fail-safe Power consumption @12VDC loop supply internally generated Internal monitoring of supply low voltage status Power consumption increases for pulse inputs > 10Hz. General Data Operating Temperature Humidity EMC Standards Mounting LED indication: Transmitter Unit LED indication: Receiver Unit frequency hopping spread spectrum Transmit power Maximum line of sight range Antenna connector Dimensions mm (in) Configuration Diagnostics Ordering Data Kit Contents 20 two inputs, suitable for voltage free contacts / NPN, or voltage input 0-1 VDC on / >3 VDC off max rate 10 Hz, 50 msec on time. Pulse counted as16 bit register. Receiver 100mA, Transmitter 40mA quiescent, during radio transmission (50 msec) 300mA RS232 RJ45 female DCE, used for configuration Power/OK, Radio TX, DIN1, DIN2, Setpoint status Power/OK, Radio RX, DO1, DO2, DO3, Communications Fail. 20 miles (4W ERP), 15km ( ERP); 3000 ft / 1000 m in obstructed industrial environments.radio distances can be increased by up to 5 intermediate repeater units. Each transmission may be configured to be sent 1 to 5 times. Factory configuration transmitter/receiver matched pair, AI to AO, 2DI to 2DO, SP status to DO3. User configuration via serial port. Unidirectional units can be configured to network with Multi-I/O and Gateway units. Diagnostics features - read input values, write output values, radio signal strength, monitor communication messages. WI-I/O 9-L-P1 6720005007 Two -2 db Dipole antennas (6720005086) Two 3 ft. antenna connecting cables/brackets One configuration cable two inputs, suitable for voltage free contacts / NPN, or voltage input 0-1 VDC on / >3 VDC off max rate 10 Hz, 50 msec on time. Pulse counted as16 bit register. Receiver 100mA, Transmitter 40mA quiescent, during radio transmission (50 msec) 300mA RS232 RJ45 female DCE, used for configuration Power/OK, Radio TX, DIN1, DIN2, Setpoint status Power/OK, Radio RX, DO1, DO2, DO3, Communications Fail. LEDs also used to provide radio signal strength indication 20 miles (4W ERP), 15km ( ERP); 3000 ft / 1000 m in obstructed industrial environments. Radio distances can be increased by up to 5 intermediate repeater units. Each transmission may be configured to be sent 1 to 5 times. Factory configuration transmitter/receiver matched pair, AI to AO, 2DI to 2DO, SP status to DO3. User configuration via serial port. Unidirectional units can be configured to network with Multi-I/O and Gateway units. Diagnostics features - read input values, write output values, radio signal strength, monitor communication messages. WI-I/O 9-L-P2 6720005008 Two 0 db Dipole antennas (6720005080) Two 15 ft. antenna connecting cables/brackets One configuration cable