Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas 34-XY-03-01, May 2012 Function The WG/A5xx is part of the XYR 5000 family of wireless products. These transmitters cover a wide pressure range, and can be used to monitor a variety of processes and assets in hazardous and remote areas. Since there are no wires to run, the transmitter can be installed and operational in minutes, quickly providing information about the variable being monitored. The Smart Response Manager allows the transmitter to adapt to changing process conditions, allowing greater visibility to process variation. Smart Response Manager allows the user to set thresholds which, when exceeded, cause the transmitter to adjust sampling and data transmission rates. Wireless Transmitters The transmitter combines a high accuracy piezoresistive sensor with a Radio Frequency (RF) transceiver operating in the 900MHz license-free band. Communication is a digital protocol, using Frequency Hopping Spread Spectrum (FHSS). FHSS ensures data integrity by continually switching the carrier wave over a wide range of frequencies. Power is supplied by a C size 3.6 V lithium battery, with an expected lifetime of up to five years. Base Radio Enjoy the benefits of wireless technology today: Improve Product Quality Ensure High Uptime Reduce Maintenance and Operational Costs Meet Regulatory Requirements Enhance Flexibility
XYR 5000 WG5xx/WA5xx Wireless Gauge and Absolute Pressure Transmitters 2 Models Gauge Pressure Model # UPPER RANGE LIMIT PSIG/BAR DIAPHRAGM/BODY MATERIAL (wetted parts) WG511 0 30/2.1 316L SS/304 SS WG512 0 250/17.2 316L SS/304 SS WG513 0 1000/69 316L SS/304 SS WG514 0 5000/344.7 17-4 PH/304 SS WG519 0 10000/690 17-4 PH/304 SS Absolute Pressure Model # UPPER RANGE LIMIT PSIA/BAR DIAPHRAGM MATERIAL (wetted parts) WA515 0 30/2.1 316L SS/304 SS WA516 0 250/17.2 316L SS/304 SS Remote Gauge Pressure without Yagi Model # UPPER RANGE LIMIT PSIG/BAR DIAPHRAGM/BODY MATERIAL (wetted parts) WG521 0 30/2.1 316L SS/316 SS WG522 0 250/17.2 316L SS/316 SS WG523 0 1000/69 316L SS/316 SS WG524 0 5000/344.7 17-4 PH/316 SS WG525 0 100/6.9 316L SS/316 SS WG526 0 15/1.03 316L SS/316 SS WG529 0 10000/690 17-4 PH /316 SS Remote Gauge Pressure with Yagi Model # UPPER RANGE LIMIT PSIG/BAR DIAPHRAGM/BODY MATERIAL (wetted parts) WG561 0 30/2.1 316L SS/316 SS WG562 0 250/17.2 316L SS/316 SS WG563 0 1000/69 316L SS/316 SS WG564 0 5000/344.7 17-4 PH/316 SS WG565 0 100/6.9 316L SS/316 SS WG566 0 15/1.03 316L SS/316 SS WG569 0 10000/690 17-4 PH/316 SS
XYR 5000 WG5xx/WA5xx Wireless Gauge and Absolute Pressure Transmitters 3 Wireless General Specifications Wireless Communication RF Transmit Power Data Rate 902 MHz 928 MHz Frequency Hopping Spread Spectrum (FHSS) FCC certified ISM license-free band. Every data block transmitted is verified (CRC check) and acknowledged by the Base Radio. 31 mw, 17.8 mw typical. Configurable: 4.8 Kbps, 19.2 Kbps, or 76.8 Kbps. Antenna Omnidirectional Yagi Directional Signal Range Internal 3 omni-directional, ¼ wave, monopole. Up to 2000 feet (600 meters) from Base Radio with clear line of sight.* *Actual range may vary depending on site topography. Length: 18. Gain: 6 dbd. Weight: 1.5 lbs. Polarization: Vertical. Up to 5000 feet (1500 meters) from Base Radio with clear line of sight.* Self Diagnostics Self-checking software and hardware that identifies and reports out of spec conditions, and field unit low battery voltage Site Survey Tools RSSI Link Test Received Signal Strength Indicator displays the RF signal strength in one of seven ranges. Link Test measures the wireless link performance of a transmitter running in normal operating mode. This function looks at wireless performance in both directions, from the transmitter to base radio and vice versa and assigns a rating to that performance or quality of signal. Features Automatic Re-transmit Battery Life Saver The field unit checks with the base radio to insure successful receipt of data. If data was not received, the transmitter retries on the next RF cycle. Ensures communication confidence in the harshest of industrial environments. At the maximum transmit rate this feature is inactive. To save conserve battery power, all field units will attempt to synchronize with the network using the following technique: Time Field Unit Synchronization Attempts and Attempt Delay 0 1 minute Continuous Synchronization attempts 1 10 minutes One attempt with a 10 second delay between attempts 10 30 minutes One attempt with a 30 second delay between attempts 30 60 minutes One attempt with a 1-minute delay between attempts 1 12 hours Three-attempt burst with a 5-minute delay between attempts 12 24 hours Three-attempt burst with a 10-minute delay between attempts 24 36 hours Three-attempt burst with a 30-minute delay between attempts 36 48 hours Three-attempt burst with a 1-hour delay between attempts 48 + hours Three-attempt burst with a 2-hour delay between attempts
XYR 5000 WG5xx/WA5xx Wireless Gauge and Absolute Pressure Transmitters 4 Operating/Storage Conditions Humidity Temperature Ambient Sensor: Ambient Electronics: Process fluid: Display (Full visibility): Display (Reduced visibility): Storage: 99% RH (non-condensing). -40 to +230 F (-40 to +110 C) -40 to +149/+185 F (-40 to +65/+85 C) (see Model Selection Guide) -40 to +250 F (-40 to +121 C) -4 to +158 F (-20 to +70 C) -40 to +185 F (-40 to +85 C) -58 to +185 F (-50 to +85 C) Device Configuration Parameter Configuration Configuration Panel RF Channel Setup: 1 to 16. Baud Rate: 4.8 Kbps, 19.2 Kbps, 76.8 Kbps. RF ID: 1 to 100. Password. Tag Name (up to 21 characters). Normal Transmit Rate: (1 5 sec, 10 sec, 15 sec, 20 sec, 40 sec, 1 min). Normal Sampling Rate: (1 10 sec, 15 sec, 20 sec, 30 sec, 1 min). Abnormal Transmit Rate: (1 5 sec, 10 sec, 15 sec, 20 sec, 40 sec, 1 min). Abnormal Sampling Rate: (1 10 sec, 15 sec, 20 sec, 30 sec). Pressure Normal Upper Value: Disabled/Enabled. Enabled to change Sampling and Transmit rates during abnormal process conditions. Pressure Normal Lower Value: Disabled/Enabled. Enabled to change Sampling and Transmit rates during abnormal process conditions. Engineering Units: PSI, bar, mbar, Pa, kpa, Torr, Atm, inh20, inhg, fth20, mmhg, g/cm2, kg/cm2. Pressure Zero. Offset: User defined offset will be transmitted instead of actual value. Trim: Applies a user-defined one- or two-point correction curve to the actual value. Integrated LCD display with membrane switch buttons for local configuration. LCD display is 7-digit (alternating) high contrast, anti-reflective monochrome. Display cycles between pressure level and RF status. Performance Models: WG511, 512, 513, 521, 522, 523, 525, 526, 561, 562, 563, 565, 566 WA515, 516 Accuracy (linearity and hysteresis) ± 0.1% of full span over temperature Combined Zero and Span Stability Less than ± 0.1% of full span per year at 21 C (70 F)
XYR 5000 WG5xx/WA5xx Wireless Gauge and Absolute Pressure Transmitters 5 Performance Models: WG514, 524, 564, 519, 529, 569 Reference Span: (Accuracy) TDa: Reference Span: (Temperature) TDt Accuracy: (± % Span) (Reference includes combined effects of linearity, hysteresis and repeatability) Terminal Board Zero Temp Effect: (± % Span per 50 F [28 C]) Combined Zero and Span Temperature Effect: (± % Span per 50 F [28 C]) Thermal Hysteresis (± % Span) = 0.75 Stability (± % Span per year) = 0.50 2500 psig (172 bar) 1800 psig (124 bar) =0.312 for Process Variable < TDa or =0.110 for Process Variable = or > TDa =0.30 x Process Variable < TDt) =0.10 for Process Variable = or > TDt =0.35 x Process Variable < TDt) =0.15 for Process Variable = or > TDt Physical Specifications Process connections Base Material (bob-wetted) Electronic Housing Vibration and Shock Random Vibration Net weight Electromagnetic Compatibility (CE Compliance) 1/2" - NPTM. 304 SS Lexan V0 Rating and UV Stable. Certified per IEC EN00068 2-6 (Vibration) and 2-27 (Shock) Certified to withstand 6 g s, 15 minutes per axis from 9 500 Hz. Pressure w/o Yagi Remote Sensor w/o Yagi Remote Sensor w/yagi 1 kg (2 lbs.) 6.7 kg (13 lbs.) 7.7 kg (15 lbs.) Operates within Specifications in fields from 80 to 1,000 MHz with Field Strengths to 10 V/m. Meets EN 50082-1 General Immunity Standard and EN 55011 Compatibility Emissions Standard. Approvals Environmental protection NEMA 4X, IP 65 Combined FM/CSA FM Intrinsically safe - Class I, Div. 1, Groups A,B,C,D,E,F,G,T4, Class I, Zone 0, AEx ia IIC T4, (Ta = -40 C to +85 C) Enclosure 4 CSA - Intrinsically safe - Class I, Div. 1, Groups A,B,C,D,E,F,G,T4, Class I, Zone 0, Ex ia IIC T4, (Ta = -40 C to +85 C) Enclosure 4 Combined CE/ATEX CE EMC Conformity, ETSI EN 300 489-1 Intrinsically Safe, Zone 0/1: Ex II 1 G EEx ia IIC T4 (Ta = -40 C to +65 C) IP65 Non-Sparking, Zone 2: Ex II 3 G EEx na, IIC T6 (Ta = -40 C to +85 C) IP65
XYR 5000 WG5xx/WA5xx Wireless Gauge and Absolute Pressure Transmitters 6 Dimensions 97.5/3.84 97.5/3.84 131.5/5.19 187.2/7.38 mm/inches Integral Remote Sensor w/yagi Remote Sensor
XYR 5000 WG5xx/WA5xx Wireless Gauge and Absolute Pressure Transmitters 7 Model Selection Guides are subject to change and are inserted into the specifications as guidance only. Prior to specifying or ordering a model check for the latest revision Model Selection Guides which are published at: www.honeywellprocess.com/en-us/pages/default.aspx Model Selection Guide 34-XY-16U-01 Issue 13 Page 1 of 2 XYR 5000 Wireless Gauge & Absolute Pressure Transmitters Model Selection Guide Instructions Select the desired key number. Key Number I (Approvals) _ - - II (Options) KEY NUMBER Description Gauge Pressure Transmitter Gauge Pressure Transmitter Gauge Pressure Transmitter Gauge Pressure Transmitter Gauge Pressure Transmitter Span 0-30 psig (2 bar) 0-250 psig (17.2 bar) 0-1000 psig (69 bar) 0-5000 psig (345 bar) 0-10000 psig (689 bar) Selection WG511 WG512 WG513 WG514 WG519 Availability Absolute Pressure Transmitter Absolute Pressure Transmitter 0-30 psia (2 bar-abs) 0-250 psia (17.2 bar-abs) WA515 WA516 TABLE I - CERTIFICATION OPTIONS Certificate Approval Type Location or Classification Intrinsically CL I, II, III, Div 1, Gp A,B,C,D,E,F,G T4; Safe CL I, Zone 0, AEx ia IIC T4; Enclosure Type 4X Class I, Div 2, Groups A,B,C,D; Suitable for Combined FM & CSA ATEX* Nonincendive CL II, III, Div 2, Groups F,G, T4; CL I, Zone 2, AEx na IIC T4; Enclosure Type 4X Intrinsically CL I, II, III, Div 1, Gp A,B,C,D,E,F,G T4; Safe CL I, Zone 0, Ex ia IIC T4; Enclosure Type 4X Class I, Div 2, Groups A,B,C,D; Suitable for Nonincendive CL II, III, Div 2, Groups F,G, T4; CL I, Zone 2, Ex n IIC T4; Enclosure Type 4X Multiple Marking** Ex II 1 G EEx ia IIC T4; Ta -40 to 65 Int. Safe, Zone 0/1, Ex II 3 G EEx nl, IIC T4; Ta -40 to 85 or Non-Sparking, Enclosure IP 65 Zone 2 * See ATEX installation requirements in the Operator's Manual. ** The user must determine the type of protection required for installation of the equipment. The user shall then check the box [ ] adjacent to the type of protection used on the equipment certification label. Once a type of protection has been checked on the label, the equipment shall not then be reinstalled using any of the other certification type. AG 3G b TABLE II - OPTIONS Battery Holder Only - No Battery Included Battery Battery - Standard Included Standard Warranty Warranty Additional Warranty - 1 year Additional Warranty - 2 years 00 B1 00 W1 W2 RESTRICTIONS Restriction Letter Available Only With Not Available With Table Selection Table Selection b Mutually exclusive - select one NOTE: Manuals are provided on CD with each shipment. Manuals may also be downloaded free of charge @ http://hpsweb.honeywell.com/cultures/en-us/products/instrumentation/xyr5000wireless/default.htm
XYR 5000 WG5xx/WA5xx Wireless Gauge and Absolute Pressure Transmitters 8 XYR 5000 Wireless Remote Sensor GP Transmitters 34-XY-16U-16 Issue 9 Page 1 of 1 Model Selection Guide Instructions Select the desired key number. Key Number I (Approvals) _ - - II (Options) KEY NUMBER Description Span Selection 0-30 psig (2 bar) WG521 0-250 psig (17.2 bar) WG522 0-1000 psig (69 bar) WG523 0-5000 psig (345 bar) WG524 0-100 psig (6.9 bar) WG525 0-15 psig (1 bar) WG526 Availability 0-30 psig (2 bar) 0-250 psig (17.2 bar) 0-1000 psig (69 bar) 0-5000 psig (345 bar) 0-100 psig (6.9 bar) 0-15 psig (1 bar) WG561 WG562 WG563 WG564 WG565 WG566 TABLE I - CERTIFICATION OPTIONS Certificate Approval Type Location or Classification Intrinsically CL I, II, III, Div 1, Gp A,B,C,D,E,F,G T4; Combined FM & CSA (CSA Pending) ATEX* Safe CL I, Zone 0, AEx ia IIC T4; Enclosure Type 4X Nonincendive Class I, Div 2, Groups A,B,C,D; Suitable for CL II, III, Div 2, Groups F,G, T4; CL I, Zone 2, AEx na IIC T4; Enclosure Type 4X Intrinsically CL I, II, III, Div 1, Gp A,B,C,D,E,F,G T4; Safe CL I, Zone 0, Ex ia IIC T4; Enclosure Type 4X Nonincendive Class I, Div 2, Groups A,B,C,D; Suitable for b CL II, III, Div 2, Groups F,G, T4; CL I, Zone 2, Ex n IIC T4; Enclosure Type 4X Multiple Marking** Ex II 1 G EEx ia IIC T4; Ta -40 to 65 Int. Safe, Zone 0/1, or Ex II 3 G EEx nl, IIC T4; Ta -40 to 85 3G Non-Sparking, Zone 2 Enclosure IP 65 * See ATEX installation requirements in the Operator's Manual. ** The user must determine the type of protection required for installation of the equipment. The user shall then check the box [ ] adjacent to the type of protection used on the equipment certification label. Once a type of protection has been checked on the label, the equipment shall not then be reinstalled using any of the other certification type. AG TABLE II - OPTIONS Battery Holder Only - No Battery Included Battery Battery - Standard Included Standard Warranty Warranty Additional Warranty - 1 year Additional Warranty - 2 years 00 B1 00 W1 W2 RESTRICTIONS Restriction Available Only With Not Available With Letters Table Selection Table Selection b Mutually exclusive - select one NOTE:
XYR 5000 WG5xx/WA5xx Wireless Gauge and Absolute Pressure Transmitters 9 Sales and Service For application assistance, current specifications, pricing, or name of the nearest Authorized Distributor, contact one of the offices below. ASIA PACIFIC (TAC) hfs-tacsupport@honeywell.com Australia Honeywell Limited Phone: +(61) 7-3846 1255 FAX: +(61) 7-3840 6481 Toll Free 1300-36-39-36 Toll Free Fax: 1300-36-04-70 China PRC - Shanghai Honeywell China Inc. Phone: (86-21) 5257-4568 Fax: (86-21) 6237-2826 EMEA Honeywell Process Solutions, Phone: + 80012026455 or +44 (0)1202645583 FAX: +44 (0) 1344 655554 Email: (Sales) sc-cp-appssalespa62@honeywell.com or (TAC) hfs-tacsupport@honeywell.com NORTH AMERICA Honeywell Process Solutions, Phone: 1-800-423-9883 Or 1-800-343-0228 Email: (Sales) ask-ssc@honeywell.com or (TAC) hfs-tacsupport@honeywell.com SOUTH AMERICA Honeywell do Brasil & Cia Phone: +(55-11) 7266-1900 FAX: +(55-11) 7266-1905 Email: (Sales) ask-ssc@honeywell.com or (TAC) hfs-tacsupport@honeywell.com Singapore Honeywell Pte Ltd. Phone: +(65) 6580 3278 Fax: +(65) 6445-3033 South Korea Honeywell Korea Co Ltd Phone: +(822) 799 6114 Fax: +(822) 792 9015 Specifications are subject to change without notice.
XYR 5000 WG5xx/WA5xx Wireless Gauge and Absolute Pressure Transmitters 10 For More Information Learn more about how Honeywell s XYR 5000 Wireless Gauge and Absolute Pressure Transmitters can be used to monitor a variety of processes, visit our website www.honeywellprocess.com/xyr-5000 or contact your Honeywell account manager. Honeywell Process Solutions 1860 West Rose Garden Lane Phoenix, Arizona 85027 Tel: 1-800-423-9883 or 1-800-343-0228 www.honeywellprocess.com 34-XY-03-01 May 2012 2010 Honeywell International Inc.