API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined



Similar documents
AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report

WATERS QUANTITATIVE ANALYSIS solutions

SERVICE PLANS. More Productivity. Less Worry. SERVICE PLANS

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

AxION edoor. Web-Based, Open-Access Mass Spectrometry Software

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Factors Influencing LC/MS/MS Moving into Clinical and Research Laboratories

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

NUVISAN Pharma Services

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

aurora ICP-MS Innovation with Integrity The Science of Sensitivity ICP-MS

The Sievers 900 Series TOC Analyzers

LC-MS/MS for Chromatographers

Appendix 5 Overview of requirements in English

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

Waters Core Chromatography Training (2 Days)

NexION 350 ICP-MS Maximum throughput. Minimum downtime. Optimum insight.

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

ProteinPilot Report for ProteinPilot Software

Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS. Mikaël LEVI Shimadzu France

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

AutoSpec Premier. Are you? Analyzing dioxins and related compounds? Required to satisfy regulatory requirements?

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

How To Test For Contamination In Large Volume Water

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Rapid and Reproducible Amino Acid Analysis of Physiological Fluids for Clinical Research Using LC/MS/MS with the atraq Kit

LIFECYCLE. Thermo Scientific. Enterprise Solutions

Smart Monitoring Service

SCION SQ Series GC-MS

RapidFire High-throughput MS technology. Enhancing Drug Discovery Turning Mass Specs into Plate Readers

TotalChrom. Chromatography Data Systems. Streamlining your laboratory workflow

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

DO MORE AND DO IT WITH CONFIDENCE. Empower 3 Chromatography Data Software

Hardware Manual. AB SCIEX API 4000 LC/MS/MS System

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

AMD Analysis & Technology AG

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

aurora M90 Innovation with Integrity A new era in ICP-MS ICP-MS

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

A Streamlined Workflow for Untargeted Metabolomics

Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

Integration of DiscoveryQuant Software into Automated In-Vitro ADME Assay Workflows

SimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data

QGA Quantitative Gas Analyser

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

endless One platform possibilities for DNA, RNA, protein and cell analysis Agilent 2100 Bioanalyzer Our measure is your success.

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Investigating Biological Variation of Liver Enzymes in Human Hepatocytes

SimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data

Cliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.

Analytical Products and Solutions. Complete service and maintenance solutions for your analytical equipment. usa.siemens.com/analyticalproducts

Welcome to the fully integrated autoimmune laboratory. Saves time by reducing hands-on functions NOVA Lite Barcoded IFA Slides

Introduction. Methods. Sample Processing

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

Considerations When Validating Your Analyst Software Per GAMP 5

Analyst 1.6 Software. Software Reference Guide

UV-Vis spectrophotometers

Pesticide residue analysis: New Trends. Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific

AppNote 4/2014. Prep-and-Shoot : The Completely Automated Workfl ow for the Hydrolysis and Analysis of Urine Samples by LC/MS/MS.

Thermo Scientific ConFlo IV Universal Interface

Measurement & Analytics. VIS Multiphase Flow Meter High gas content applications solved with no radioactive source - Measurement made easy

ProSightPC 3.0 Quick Start Guide

Validation Guide for the DNA IQ Reference Sample Kit for Maxwell 16 Printed in USA. 9/06 Part# GE181

Analyst 1.6 Software. Getting Started Guide

Phoenix Apollo Laboratory TOC Analyzers and Services Designed To Meet Your Needs

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

Microsoft SQL Server on Stratus ftserver Systems

Application Deployment Experts

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

IR READY TOGO. Spectrum Two FT-IR Spectroscopy

Transcription:

API 3200 LC/MS/MS SYSTEM Performance, productivity and value combined API 3200 LC/MS/MS SYSTEM

Reliability, reproducibility, and confidence in your data. With an unmatched heritage of technological innovation and dependability, the triple quadrupole API 3200 System offers an attractive blend of performance, throughput, and value.

High uptime, superior reproducibility, maximal productivity Designed for high-throughput labs doing small molecule quantitation, the compact, affordable API 3200 System delivers best-in-class reliability and reproducibility over virtually all samples encountered in environmental, food, clinical research, and pharmaceutical applications. Like all of our industry-leading triple quadrupole and QTRAP systems, the API 3200 System platform features the Turbo V ion source with plug-and-play probes that let you analyze an extended range of compounds over a wide range of flow rates. Patented Curtain Gas interface and LINAC collision cell technologies provide superior ruggedness and selectivity for your most exacting quantitative analyses. Powerful software, advanced automation features, and robust engineering increase your productivity, giving you the ability to routinely analyze hundreds of samples day after day, year after year. Absolute ionization Innovative Turbo V ion source efficiently ionizes compounds and virtually eliminates cross-contamination, even with large sample loads, for high-sensitivity quantitation over a wide range of flow rates. Superior MS/MS performance Patented, proven LINAC collision cell technology provides faster scan times. So you can analyze more compounds per run, with no compromise in sensitivity or mass spectral quality. Maximal uptime Proprietary Curtain Gas interface reduces the need for routine maintenance and ensures maximal productivity by protecting the interface region and quadrupole analyzer from contamination. Greater throughput High-productivity software applications, including automated methods development, enable unattended operation and routine analysis of hundreds of samples per day every day. Response Aldicarb sulfone (rel std dev 3.6%) Aldicarb (rel std dev 3.6%) Ease of use You don t have to be a mass spec expert to achieve expert results. Advanced acquisition and processing software completely automates setup and analysis. Results, systems, and support you can count on The API 3200 System is backed by one of the world s most extensive service and support organizations. Our promise is to help keep your lab up and running at maximal productivity. Injection Number Ruggedness and reproducibility of the API 3200 system. Running more than 1,200 injections of carbamate insecticides extracted from soil samples over the 3.5 days, the API 3200 system exhibits exceptional stability with relative standard deviations of 3.6% for the response of the two carbamates.

An affordable benchtop platform built on premier technology The API 3200 LC/MS/MS System takes advantage of a number of proprietary mass spectrometry innovations to deliver the performance required by demanding applications in regulated environments all at an excellent value. Curtain Plate Orifice Skimmer Curtain Gas Interface The proprietary Curtain Gas interface reduces the need for routine maintenance and ensures maximal uptime and productivity by protecting the interface region and quadrupole analyzer from contamination. LINAC Collision Cell The patented LINAC collision cell ensures maximal ion transfer Source free of crosstalk from the interface to the detector in MS/MS mode, allowing simultaneous multicomponent analyses. So you can monitor more compounds and multiple reaction monitoring (MRM) Curtain Gas Interface transitions without any appreciable loss in signal. LINAC collision cell technology also enables fast scanning, with uncompromised performance in all modes of operation, including product ion, precursor ion, and neutral loss scans. Curtain Plate Orifice Skimmer IQ1 Q1 Source Q0 High Pressure Cell ST IQ2 Curtain Gas Interface

Turbo V DuoSpray PhotoSpray NanoSpray III Convenient Plug and Play Ion Sources Rugged, reliable, and easily interchangeable ion sources are available for a wide range of applications and flow rates to suit your analysis needs. Rapid source changeover minimizes downtime and simplifies routine maintenance. All connections are fully integrated into the source housing There are no extra lines to attach and no lost time. The innovative Turbo V ion source efficiently ionizes compounds and virtually eliminates cross-contamination, even with large sample loads. Embedded ceramic heater technology and improved gas dynamics contribute to the system s low detection limits and enable high-sensitivity quantitation over a wide flow range up to 3 ml/min. The quick-change ESI and APCI probes let you switch between ionization modes in seconds. The DuoSpray Source contains two separate inlets for ESI and APCI probes, allowing the optimal ionization technique and conditions for each compound during an LC run. It speeds up method development while also increasing throughput and data quality. The PhotoSpray Source for atmospheric pressure photo-ionization expands the range of compounds that can be analyzed, often at higher sensitivities than ESI or APCI. The PhotoSpray source can ionize many compounds that are not easily ionized by ESI or APCI, such as polyaromatic hydrocarbons (PAHs). The NanoSpray III Source is an ultra low flow source designed for minimal sample consumption and highest sensitivity at flow rates from 50 nl/min to 2 μl/min. It is ideal for analyzing biological samples such as peptides and proteins even with very small sample amounts. The source features easy tip and column replacement with finger-tight fittings and a quick release spray assembly for simplified maintenance and troubleshooting. Q2 Q3 Exit DF LINAC Collision Cell IQ3 Q3 Detector

More reliable, more confident results from every experiment A new generation of industry-trusted Analyst software lets you configure, tune, acquire data, explore, and quantitate with high confidence even when working with complex matrices. You can automatically create fully optimized methods for multiple compounds, quickly generate new quantitation methods, and analyze and compare analytical results. Analyst software also provides a comprehensive feature set for GLP labs, including full support for 21 CFR Part 11 compliance. It offers an easily administered, integrated security model that adapts to the needs of your lab, and gives you added confidence in your data. Powerful, automated add-on applications, such as Information Dependent Acquisition (IDA) further extend the system s data acquisition and processing capabilities.

Outstanding Inter- and Intra-day Quantitative Performance r=0.9999 r=0.9998 Impressive linearity over a wide dynamic range is demonstrated in this calibration curve of five replicate injections at each concentration level of cyanazine, a triazine herbicide. The excellent accuracy and percent coefficient of variation (%CV) illustrate the consistent high-quality quantitative results achievable day after day with the API 3200 System. To confirm the stability and reproducibility of the calibration and quantitative performance of the API 3200 System, three replicate injections of atrazine were run at each concentration level to create the calibration curve above. During the course of the four-day study, nine replicate injections were run at each concentration level. The %CV and accuracy surpass the typical quantitative analysis performance requirements and demonstrate the exceptional stability and reproducibility of the API 3200 System. Outstanding inter- and intra-day quantitative performance makes rapid validation of your methods a certainty. Simplified Cross-Platform Methods Transfer Many labs employ multiple AB SCIEX triple quadrupole and QTRAP LC/MS/MS systems in their daily work. Because all of these platforms use the same Analyst software and Turbo V ion source, method transfer is quick and easy simply copy over the source parameters, adjust compound-specific instrument parameters, and start running. In this way, a method can be developed on the API 3200 System and then transferred among other AB SCIEX platforms, such as AB SCIEX 5500 Systems, providing extra flexibility for busy labs looking to maximize output.

You invest in our technology. We invest in your success. As the world leader in mass spectrometry, AB SCIEX solutions are backed by the industry s most extensive service and support organization. With more than 1000 service professionals, experienced compliance specialists, and over 150 PhD application scientists worldwide, we are dedicated to supporting your technical needs and helping you get the most out of your AB SCIEX systems. AB SCIEX service professionals are recognized as the most highly qualified in the industry. They are certified on our instrument platforms through a rigorous 4-step certification program, with re-certification occurring every two years. This award-winning program helps to ensure that you receive the most efficient, highest-quality, and most up-to-date service available for AB SCIEX products and technology. Choose from flexible service plans and a variety of services for the right level of support for your laboratory s needs and budget. Our customer support network is available to provide expert assistance in the use and application of AB SCIEX products through a comprehensive range of services, including application support, technical service, and training. Whether you access our service and support team by phone, email, on-site visits, or through our innovative remote monitoring technology, you can be confident that the AB SCIEX organization will be there for you 24x7. For more information, visit www.absciex.com For Research Use Only. Not for use in diagnostic procedures. 2010 AB SCIEX. The trademarks mentioned herein are the property of AB Sciex Pte. Ltd. or their respective owners. AB SCIEX is being used under license. 0280510-01 07/2010 Headquarters 353 Hatch Drive Foster City CA 94404 USA Phone 650-638-5800 www.absciex.com International Sales For our office locations please call the division headquarters or refer to our website at www.absciex.com/offices