A gas ion source for continuous-flow AMS



Similar documents
An example: helium isotopes. An example: helium isotopes. Limits to Detection/Measurement. Lecture 14 Measurements II: Mass spectrometry

Status of High Current Ion Sources. Daniela Leitner Lawrence Berkeley National Laboratory

High Power Neutral Beam Injection in LHD

AMD Analysis & Technology AG

Background Information

Chemical Sputtering. von Kohlenstoff durch Wasserstoff. W. Jacob

Analyzing Small Molecules by EI and GC-MS. July 2014

Vacuum Evaporation Recap

13C NMR Spectroscopy

Polymer growth rate in a wire chamber with oxygen, water, or alcohol gas additives

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

HIGH CURRENT OPERATION OF THE ACSI TR30 CYCLOTRON

Pesticide Analysis by Mass Spectrometry

INFRARED MONITORING OF 110 GHz GYROTRON WINDOWS AT DIII D

Tuning & Mass Calibration

Thermo Scientific ConFlo IV Universal Interface

Chapter 1: Moles and equations. Learning outcomes. you should be able to:

Principles of Ion Implant

Ion Beam Sputtering: Practical Applications to Electron Microscopy

CONCEPT OF DETERMINISTIC ION IMPLANTATION AT THE NANOSCALE

EXPERIMENTAL CONDITIONS FOR CROSS SECTION MEASUREMENTS FOR ANALYTICAL PURPOSES. L. Csedreki 1. Abstract. I. Introduction

Remote Monitoring and Control of Irradiation Experiments

Lecture 12. Physical Vapor Deposition: Evaporation and Sputtering Reading: Chapter 12. ECE Dr. Alan Doolittle

Nuclear Structure. particle relative charge relative mass proton +1 1 atomic mass unit neutron 0 1 atomic mass unit electron -1 negligible mass

2 Absorbing Solar Energy

Plasma Source. Atom Source, Ion Source and Atom/Ion Hybrid Source

Characterization of excited states of 15 N through 14 C(p,p) 14 C using polarized proton beam

Coating Technology: Evaporation Vs Sputtering

CHROMOCTANE O N LINE ANALYZER


Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Mass Spectrometry. Overview

Secondary Ion Mass Spectrometry

Experimental Study on Super-heated Steam Drying of Lignite

CHE334 Identification of an Unknown Compound By NMR/IR/MS

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Mass spectrometry. What are the principles behind MS? What do all MS instruments have in common?

Short overview of TEUFEL-project

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

The TSL 6.4 GHz ECR ion source status, improvements and measurements

Nuclear Physics. Nuclear Physics comprises the study of:

Lab 7: Residual Gas Analyzers

The photoionization detector (PID) utilizes ultraviolet

Dose enhancement near metal electrodes in diamond X- ray detectors. A. Lohstroh*, and D. Alamoudi

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Supporting information

Overview. Inficon s Product

How To Build An Amd Quas 3 Ar Mass Spectrometer

1. In the general symbol cleus, which of the three letters. 2. What is the mass number of an alpha particle?

Gamma Ray Detection at RIA

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)

[ Care and Use Manual ]

= atm. 760 mm Hg. = atm. d. 767 torr = 767 mm Hg. = 1.01 atm

The HEMP Thruster - An Alternative to Conventional Ion Sources?

The ithemba LABS Radioactive Beam Project. R A Bark

Accurate calibration of on-line Time of Flight Mass Spectrometer (TOF-MS) for high molecular weight combustion product analysis

Modern approaches to determination of toxic metals in marine environmental objects. Atomic absorption and inductively coupled plasma, advantages and

QGA Quantitative Gas Analyser

Expectations for GC-MS Lab

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

On-line Dissolved Gas Analysis

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

Name Class Date. F N A cm 2 A cm 2 Unknown: Step 2: Write the equations for Pascal s principle and pressure, force, and area.

A new concept for isotope ratio monitoring LC/MS. A Wide Range of Applications

How To Test For Contamination In Large Volume Water

Chapter 2: The Chemical Context of Life

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

Introduction to Geiger Counters

The Use of Hydrogen Carrier Gas for GC/MS

How To Use Gc-Ms

Process Instrumentation

Reaction Engineering of Polymer Electrolyte Membrane Fuel Cells

Request for Quotes Goods/Trade Services RFQ for Gas Chromatograph Mass Spectrometer (GCMS) (PCS# RFQ)

Exhaust emissions of a single cylinder diesel. engine with addition of ethanol

CH3 Stoichiometry. The violent chemical reaction of bromine and phosphorus. P.76

Technique of Monitoring Dioxins in Flue Gas from MSW Incinerators using Dioxin Precursor Analyzer

Experiment #5: Qualitative Absorption Spectroscopy

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Balancing chemical reaction equations (stoichiometry)

RF SYSTEM FOR VEPP-5 DAMPING RING

BTU ANALYSIS USING A GAS CHROMATOGRAPH

MYRRHA Injector Design

AS COMPETITION PAPER 2008

LC-MS/MS for Chromatographers

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

MEMS mirror for low cost laser scanners. Ulrich Hofmann

HSeries. High Power High Quality. Ultra-High Speed, Sensing Ionizer SJ-H Series

Solar Energy. Outline. Solar radiation. What is light?-- Electromagnetic Radiation. Light - Electromagnetic wave spectrum. Electromagnetic Radiation

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

Fuel Cell Activities at TU Graz

Chapter 5 TEST: The Periodic Table name

ORGANIC SAMPLE PREPARATION

Transcription:

Nuclear Instruments and Methods in Physics Research B 223 224 (2004) 149 154 www.elsevier.com/locate/nimb A gas ion source for continuous-flow AMS R.J. Schneider a, *, S.-W. Kim a,c, K.F. von Reden a, J.M. Hayes a, J.S.C. Wills b, V.S. Griffin a, A.L. Sessions a, S. Sylva a a Woods Hole Oceanographic Institution, Mail Stop 8, Woods Hole, MA 02543, USA b ChalkRiver Laboratories, ChalkRiver, ON, Canada K0J 1J0 c Advanced Technology Institute Ltd., Sapporo, Hokkaido 006-0814, Japan Abstract The first gas-fed ion source for radiocarbon AMS applications (without sputtering) has been operated at the Woods Hole NOSAMS Facility. A three-year, off-line test program resulted in positive carbon ion currents up to 1 ma and negative ion currents up to 80 la. Recently, the compact, permanent-magnet microwave plasma ion source and magnesium vapor charge-exchange canal were coupled to the recombinator injector of the 2.5 MV Tandetron. When the ion source was operated on CO 2 at a flow rate of about 200 ll per minute, negative carbon ion beams up to 20 la were obtained, at an energyof 35 kev. Radiocarbon measurements were performed on standard reference gases and the dynamic response to square-wave pulses of gas was determined. Time constants in the ion source are less than 1 s, which should allow analysis of chromatographic peaks of CO 2 with verylittle broadening. A combustion device has been constructed to generate CO 2 for direct injection into the source. Argon carrier gas is used to buffer the pressure at one atmosphere in the sample gas injector. A dedicated ion-beam injector, with higher angular acceptance and higher transmitted currents, is being constructed for the AMS system. Ó 2004 Published byelsevier B.V. PACS: 82.80.Ms; 29.25.Ni; 27.20.+n Keywords: Radiocarbon; Ion source; Accelerator mass spectrometry 1. Introduction A microwave plasma ion source has been tested extensivelyusing a test stand which included a silica-capillary-based gas handling system to produce constant flows in the range of 100 1000 ll/ min into a plasma discharge. When a flow of CO 2 was introduced into the ion source, a positive ion * Corresponding author. Tel.: +1-508-289-2756; fax: +1-508- 457-2183. E-mail address: rschneider@whoi.edu (R.J. Schneider). current was extracted and analyzed with a spectrometer magnet. Small samples containing several micromoles of CO 2 could be entrained in a stream of argon used as a carrier gas. In this way, a stable plasma discharge was maintained. To obtain negative carbon ions for use in AMS systems, a charge-exchange canal was inserted immediately following the ion source. The argon beam was largelyneutralized and passed into a beam dump whereas the negative carbon ion beam was analyzed. The results of these tests have been reported in [1 3]. A short summaryappears in Table 1. The efficiencyof producing positivelycharged carbon 0168-583X/$ - see front matter Ó 2004 Published byelsevier B.V. doi:10.1016/j.nimb.2004.04.031

150 R.J. Schneider et al. / Nucl. Instr. and Meth. in Phys. Res. B 223 224 (2004) 149 154 Table 1 Typical microwave ion source test stand results, with a 5-mm extraction aperture and a 5-mm gap and gas flows of 0.25 ml/min Analyzed current Extraction supply Canal temperature ( C) RF power (W) 2.5 ma, argon 35 kv/12 ma 50 84 735 la, 12 C þ 35 kv/15 ma 50 220 81 la, 12 C 35 kv/15 ma 498 221 ions from continuouslyflowing CO 2 molecules with this ion source is about 4% and the conversion yield of the charge exchange process is about 8.5%. We obtained positive carbon ion currents close to 1 ma and measured 13 C/ 12 C ratios with instabilityof less than 1% over a 20 h period. We began byusing pure CO 2 gas flowing into the ion source at about 0.2 ml/min. We also constructed a gaspulse injector (described in [1], with the latest version shown in Fig. 1) for studying the time-response of the system to well-defined pulses of CO 2 carried within an argon carrier gas stream. With this device, we learned the importance of eliminating small dead volumes of gas, which can contribute to long tails on injected gas pulses and consequentlyon the ion pulses. The efficiencyof C þ ion production in pulse mode is reduced from Fig. 1. Gas-sampling system used in testing and development of the microwave ion source. Each of the large circles represents a valve in which alternate sets of adjacent ports can be connected. In the state shown, loop 1 is being purged with Ar carrier gas which is flowing to the open split. The gas not being accepted bythe flow-limiting capillaryis being directed to a flow meter. Simultaneously, loop 2 is being filled with CO 2. Toggling the sampling valve places the CO 2 sample into the stream being sent to the ion source. the continuous flow mode, bythe splitting factor of the open split (as shown in Fig. 7). There are generallytwo components in the decayof an ion pulse from the source. The short component, with a time constant less than 1 s, depends on ion extraction from the plasma discharge. The long component, with a time constant 10 100 s or more, is dominated bythe release of molecules from these trapped volumes but also includes delayed release of molecules which stick to the walls of the discharge chamber. We believe that the AMS communityhas been discouraged in the past from pursuing this method in the mistaken belief that it was the wall effect which dominated the tailing rather than simple, deadvolume trapping. At the Lawrence BerkeleyLaboratory, where radioactive beams are generated with high frequencyecr (Electron Cyclotron Resonance) ion sources, the decaytimes for 11 C 4þ have been measured [5]. The fast component was 3 to 6 s, and the slow component was about 6 min. The latter was thought to represent wall-sticking from the plasma chamber, but mayhave also been influenced bysmall trapped volumes. Since we needed to produce negative ions for injection into the tandem accelerator, we then added a magnesium vapor charge exchange canal and were able to obtain negative carbon ion currents up to 80 la. In the past, sodium, lithium and cesium have all been used as donors of electrons for negative ion formation. A comprehensive studywas made at Universityof Aarhus in the late 1970s [4]. The equilibrium charge state fraction for carbon ions (having an electron affinity1.268 ev) in magnesium vapor was around 10%. There is both less scattering and a lower equilibrium target thickness for carbon ions in magnesium vapor than in the heavier alkali vapors. As a practical matter, the handling and cleaning of sodium- and lithium-vapor charge-exchange canals has often

R.J. Schneider et al. / Nucl. Instr. and Meth. in Phys. Res. B 223 224 (2004) 149 154 151 reduced the efficiencyof use. The magnesium sublimes directlyfrom a solid to a vapor. No dangerous condensates are formed and the scale on the copper heat-shield can be soaked off in a bucket of water (outdoors, for release of hydrogen). The 1 cm diameter by16 cm long vapor cell [3] is operated at a temperature of 495 C. The beam emerging from the canal has a half-angle of 0.71. We obtain about 8.5% efficiencyfor the production of negative carbon ions. charge-exchange canal. Tests were carried out from Januaryto earlymay, 2002, during intervals in the radiocarbon-analysis production schedule. At first, pure CO 2 was introduced into the ion source. Ions were extracted at 35 kv, with the 2. Installation on the AMS In December of 2001 we mounted the microwave ion source and charge-exchange canal onto the recombinator injector of the NOSAMS accelerator for a test. To do this, it was necessaryto temporarilydismount the NEC-MCSNICS sputter ion source from one of the recombinators. The arrangement is shown in Fig. 2. The acceptance of the recombinator is limited, so we inserted a watercooled, 5-mm aperture to limit the beam emerging from the charge-exchange canal to a half-angle of 0.25. The resulting intensitywas about 23% of the total output. We also installed graphite blocks in the first magnet chamber where we expected argon ions to hit if theywere not neutralized bythe Fig. 2. Plan view of the microwave ion source and chargeexchange canal as theywere installed on the recombinator injector of the AMS system, January 2002. A neutral beam dump, consisting of a water-cooled copper cylinder, was used to collect the Ar beam from the Ar carrier gas. Not shown is the other injector, or the complete accelerator. Fig. 3. Mass spectrum as measured with a Faradaycup in the symmetryplane of the recombinator. There appears to be verylittle hydride component present, as the gas was pure CO 2.

152 R.J. Schneider et al. / Nucl. Instr. and Meth. in Phys. Res. B 223 224 (2004) 149 154 2.8E-08 14 2.4E-08 12 2.0E-08 10 Current (A) 1.6E-08 1.2E-08 8 6 14 C Counts/s 8.0E-09 4 4.0E-09 2 0.0E+00 0:00 0:04 0:08 0:12 0:16 0:20 0:24 Time (h:mm) Fig. 4. Currents of 12 C (solid lines) and 13 C (dashed lines) and counts of 14 C as collected from combusted HOxI (left) and HOxII (right) samples. The numbers of counts collected were 421 and 510, respectively. The 12 C current is attenuated bya rotarychopper to about 1% of its full intensity. 0 25 20 Current (µa) 12 C - 15 10 5 0 160 170 180 190 Time (s) Fig. 5. A carbon current pulse as measured bythe AMS system, representing a 1.1 lmol CO 2 sample injected over 10 s utilizing the system shown in Fig. 1. The fast decay has a time constant less than 1 s. suppression electrode at )1.8 kv to minimize back-streaming electrons. A mass spectrum was obtained from the Faradaycup in the symmetry plane of the recombinator. It is shown in Fig. 3. One of the first things noticed was the absence of significant hydrides, compared with output of the sputter ion source. (This maybe related to the use of small amounts of hydrogen in the preparation of graphite.) For the attempt to detect radiocarbon, we required a convenient source of modern CO 2 since tank CO 2 is radiocarbon dead. Accordingly, the first 14 C/ 12 C ratios were measured on CO 2 gas collected from fermenting beer and also from combusted oxalic acid standards and dead graphite blanks. We obtained a fraction modern of 1.068 for the beer gas, consistent with a modern taste! Data were acquired for the three carbon isotopes

R.J. Schneider et al. / Nucl. Instr. and Meth. in Phys. Res. B 223 224 (2004) 149 154 153 simultaneously, as is done with the sputter ion source, with ten-second integration times. Fig. 4 shows the counts collected from combusted HOxI and HOxII samples. A 2-m length of 100 lm capillarywas used to limit the gas flow rate to 0.25 ml/min. The overall efficiencyfor detection of ions bythe AMS system was equivalent to 0.001 ions at the collector per molecule of continuouslyflowing gas introduced to the ion source. For pulse-mode operation, the samples were loaded into 108 ll sample loops, for injection into the carrier. The AMS system response to a single 1.1 lmol pulse is shown in Fig. 5. The integration time was one second for this data. An examination of the falling side of the pulse reveals the fast (0.87 s) and slow (13.0 s) components. This has encouraged us to think of possible applications to chromatography, where the slowlyvarying outputs could easilybe resolved bythis gas ion source system. The maximum 12 C current we were able to obtain in the recombinator during these tests was 20 la due to the limited acceptance. System background counts were as low as those observed with the sputter ion source except during transmission of intense argon beams through the first magnet. Further investigation of scattered beam events needs to be done. 3. Conclusions and future plans To work around the limited acceptance of the recombinator, we are currentlybuilding a new injector which will be installed on the axis of the accelerator, as shown in Fig. 6. This will permit us to utilize the full output of the microwave ion source byusing the accelerator solelyas a 14 C detector, with the negative 12 C beam being measured off-axis in the injector. The charge-exchange canal is being closelycoupled to the ion source, for optimum transmission. Here we will relyon the stabilityof the AMS system over measurement cycles of at least one hour, which has been adequatelydemonstrated. Major components of the injector include a new double-focussing spectrometer magnet with 70-mm aperture (Buckley Systems, Auckland, New Zealand), dual Faraday cups to collect 12 Cand 13 C, and an einzel lens to focus the 14 C beam into the accelerator. We will operate this injector off-line initiallyand install it on the accelerator during 2003. During this period, we will further investigate combustion devices for producing and drying CO 2. Applications will be quite different from those using the sputter ion source. Continuouslyvarying radiocarbon sources can be measured rather than static samples. A different class of sample materials should be anticipated, since the efficiency(carbon ions per CO 2 molecule) is about 1/10 that of the best sputter source. Also, the ideal flow rate for the present ion source is about 1/10 that of a standard GC instrument. Methods of separating and splitting sample and carrier gases will have to be developed. Precision expected for 14 C/ 12 C with these limitations is shown in Fig. 7. Such a system would lend itself to detection of the absence of radiocarbon in otherwise super-modern materials, Fig. 6. Plan view of the future installation of a gas ion source injector on the AMS system. The injector is at the extreme left. Not shown is the neutral beam dump after the magnet. A lens and steerers will be used to introduce the beam into the zero-degree port of the accelerator. The (negativelycharged) stable isotopes will be measured after the magnet, and onlythe radiocarbon will be counted bythe AMS.

154 R.J. Schneider et al. / Nucl. Instr. and Meth. in Phys. Res. B 223 224 (2004) 149 154 σ R /R, % 50 20 10 5 2 Natural abundance 10x natural abundance 100x natural abundance 1 0.5 0.01 0.1 1 10 Sample, µmol C dead to 2 modern has been developed in order to explore the expected performance of the system. Acknowledgements Gas samples were supplied bythe Sample Preparation Laboratoryat NOSAMS. We thank the Universityof Toronto, for loaning us the compact microwave plasma ion source, originally built at the Chalk River Laboratories of Atomic Energyof Canada Limited and also for the loan of a large ion implanter magnet, which was used as part of the test stand. We thank Diamond Semiconductor Group (Gloucester, MA) for the loan of a 40kV power supply. This work has been supported in part bya National Science Foundation Cooperative Agreement, OCE-9807266. Fig. 7. Precision of 14 C/ 12 C ratio measurements as a function of sample size and 14 C abundance for continuous-flow analyses in which a 20 s wide pulse of CO 2 is added to argon carrier gas flowing at 0.25 ml/min. The ion source is assumed to accept 0.2 ml/min. The split efficiencyis thus 80% for small samples but lower for large samples, in which the CO 2 mayraise the flow rate, leading to the non-linearityobserved. in other words as an inverse tracer. The profiling of layers in sediments with an embedded oil spill, or the measurement of a gas which is continuously evolving from a chemical or biological reactor, come to mind. A simulated chromatogram containing components ranging from radiocarbon References [1] R.J. Schneider, K.F. von Reden, J.M. Hayes, J.S.C. Wills, W.G.E. Kern, S.-W. Kim, Nucl. Instr. and Meth. B 172 (2000) 252. [2] S.-W. Kim, R.J. Schneider, K.F. von Reden, J.M. Hayes, J.S.C. Wills, Rev. Sci. Instr. 73 (2) (2002) 846. [3] R.J. Schneider, S.-W. Kim, K.F. von Reden, J.M. Hayes, J.S.C. Wills, in: R. Hellborg (Ed.), Proceedings of Symposium North Eastern Accelerator Personnel, SNEAP XXXIV, Lund, Sweden, 2002, p. 28. [4] J. Heinemeier, P. Hvelplund, Nucl. Instr. and Meth. 148 (1978) 65. [5] D. Wutte, C. M. Lyneis, M. A. Leitner, Z. Q. Xie, in: Proceedings of the 14th International Workshop on ECR Ion Sources, CERN, Geneva, Switzerland, 1999.