SIMULTANEOUS QUANTITATIVE DETERMINATION OF OPIOID DEPENDENCY TREATMENT DRUGS IN HUMAN URINE USING UPLC/MS/MS



Similar documents
WATERS QUANTITATIVE ANALYSIS solutions

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

[ Care and Use Manual ]

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

[ DISQUE DISPERSIVE SAMPLE PREPARATION EXTRACTION PRODUCTS ] QuEChERS. Simplifed

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Jennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION

Salman Azimi, 1 Nayan S. Mistry, 2 and Michelle Wood 2. Drug Quality Control Laboratory, Supreme Council of Health, Doha, Qatar 2

Screening and quantitative determination of drugs in diluted urine by UPLC-MS-MS

ApplicationNOTE Introduction

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

Comprehensive LC/MS Analysis of Illicit and Pain Management Drugs, Including Their Metabolites, in Urine

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

[NUGENESIS SAMPLE MANAGEMENT ] AMPLE IMPROVING LAB EFFICIENCY, ANAGEMENT ACCELERATING BUSINESS DECISIONS. bigstock.com $69

A Generic Kit-Based Approach for Quantifying Monoclonal Antibody Drugs Through Direct Digestion of Discovery Study Samples

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

AutoSpec Premier. Are you? Analyzing dioxins and related compounds? Required to satisfy regulatory requirements?

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

Overview. Purpose. Methods. Results

Therapeutic Drug Monitoring of Antiretroviral Drugs with HPLC-MS

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

[ Care and Use Manual ]

AppNote 6/2011. Determination of Pain Management Drugs using Automated Disposable Pipette Extraction and LC-MS/MS KEYWORDS ABSTRACT

Glyphosate and AMPA. Medical Laboratory Bremen, Haferwende 12, Bremen, Germany. BUND, FoE

A Complete Solution for Method Linearity in HPLC and UHPLC

Successful Sample Preparation Strategies for LC/MS/MS Analysis of Drugs in Complex Biological Matrices for Forensic Toxicology Applications

Hydrophilic-Interaction Chromatography (HILIC) for LC-MS/MS Analysis of Monoamine Neurotransmitters using XBridge BEH Amide XP Columns

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

United States Department of Agriculture Food Safety and Inspection Service, Office of Public Health Science

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

An Improved SPE-LC-MS/MS Method for the Quantification of Bradykinin in Human Plasma Using the ionkey/ms System

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

AppNote 7/2009. Analysis of Drugs of Abuse using Automated Disposable Pipette Extraction and LC/MS/MS KEYWORDS ABSTRACT

One Source Toxicology Laboratory, 1213 Genoa Red Bluff, Pasadena, Texas 77504

Opiates in Urine by SAMHSA GC/MS

DEVELOPMENT OF PFCs HIGH SENSITIVITY ANALYSIS METHOD APPLIED RETENTION GAP TECHNIQUE WITH UPLC/MS/MS

Image Lab Software for the GS-900 Densitometer

Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

How To Test For Contamination In Large Volume Water

Supported Payment Methods

ProteinChip Energy Absorbing Molecules (EAM)

Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS. Mikaël LEVI Shimadzu France

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

Henry Shion, Robert Birdsall, Steve Cubbedge, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Supported Payment Methods

Introduction. Methods. Sample Processing

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

Patients with COPD were recruited according to the inclusion criteria; aged 40-75, current or

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

New drugs of abuse? A case study on Phenazepam & Methoxetamine

Waters System Solutions for Drugs of Abuse Analysis

Supplementary Materials and Methods (Metabolomics analysis)

Advances in Steroid Panel Analysis with High Sensitivity LC/MS/MS. Kenneth C. Lewis 1, Lisa St. John-Williams 1, Changtong Hao 2, Sha Joshua Ye 2

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow

E-Seminar. Financial Management Internet Business Solution Seminar

Matrix Effect in Bio-Analysis of Illicit Drugs with LC-MS/MS: Influence of Ionization Type, Sample Preparation, and Biofluid

Image Lab Software How to Obtain Stain-Free Gel and Blot Images. Instructions

A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

IOOF QuantPlus. International Equities Portfolio NZD. Quarterly update

Application of Structure-Based LC/MS Database Management for Forensic Analysis

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

A Generic LC-MS Method for the Analysis of Multiple of Drug of Abuse Classes with the Thermo Scientific Exactive TM System

Eleanor Riches Waters Corporation, Manchester, UK INTRODUCTION

Transcription:

SIMULTANEOUS QUANTITATIVE DETERMINATION OF OPIOID DEPENDENCY TREATMENT DRUGS IN HUMAN URINE USING UPLC/MS/MS Russell Watts 1, Allan Traynor 2, Michelle Wood 1. 1 Waters Corporation, MS Technologies Centre, Manchester, UK. 2 Concateno plc, London, UK. OBJECTIVE To develop and validate a single simple and rapid UPLC/MS/MS method for the simultaneous quantitative determination of the opioid dependency treatment drugs methadone, buprenorphine and dihydrocodeine in human urine. INTroDUCTION Across the developed countries of the world,.4-.8% of adults develop a dependence on illicit opioids 1. Common treatment methods include detoxification by supervised withdrawal and tapered doses of replacement drugs 2. Buprenorphine, methadone and more recently, dihydrocodeine have been shown to be effective as replacement drugs for the treatment of opioid dependency 3-5. Urine analysis of these compounds is essential to monitor abstinence and detect or confirm relapses. The associated overdose risk, potential for abuse and links with criminal activity has made the analysis of these compounds widespread in other areas of toxicology such as post-mortem and forensic. MATERIALS Specimens Validation was performed using human urine samples obtained from Concateno (London, UK) and Salford Royal NHS Foundation Trust Hospital (Manc hester, UK ). All samples were stored at -2 C until analysis. Blank urine obtained from volunteers was used as the control material to prepare all the calibrators and quality controls (QC). Standards Standard reference material, deuterated analogues and drug metabolites were purchased from LGC Promochem (Teddington, UK). A mixed standard stock solution containing buprenorphine (BUP) and norbuprenorphine (NBUP) at 12.5 µg/ml and methadone (METH), 2-ethylidene-1, 5-dimethyl-3, 3-diphenylpyrrolidine (EDDP) and dihydrocodeine (DHC) at 125 µg/ml was prepared in methanol. A mixed internal standard (IS) stock solution containing buprenorphine-d4 (BUP-D4) and norbuprenorphine-d3 (NBUP-D3) at 1.25 µg/ml and methadone-d9 (METH-D9), 2-ethylidene-1, 5-dimethyl-3, 3-diphenylpyrrolidine-D3 (EDDP-D3) and dihydrocodeine-d6 (DHC-D6) at 2.5 µg/ml was prepared in methanol. Figure 1. Waters ACQUITY TQD System.

EXPERIMENTAL Sample preparation Enzymatic hydrolysis was performed on all samples, calibrators and QC s (25 µl) after the addition of the IS (1 µl). 1 M Sodium acetate, ph 5 (2 µl) and β-glucuronidase (1 µl Helix pomatia, 1, units/ml, Sigma-Aldrich, Gillingham, UK) were added to the samples which were then heated at 56 C for 1 hour. After hydrolysis, saturated disodium tetraborate buffer (25 µl) was added to all samples and a liquid/liquid extraction (LLE) using a mixture of dichloromethane, hexane, diethyl ether and isoamyl alcohol (3:2:5:.5) was performed. The supernatant was taken to dryness using a sample concentrator block (5 C) under nitrogen, before being reconstituted with a 5/5 mix of methanol and mobile phase A (25 µl). MS conditions MS system: Ionization mode: Capillary voltage: Collision Gas Pressure: Acquisition Mode: Data Processing: Compound Precursor ion (m/z) BUP 468 468 NBUP 414 414 METH 31 31 EDDP 278 278 Waters TQ Detector ESI Positive 3 kv 4.5 x 1-3 mbar Multiple reaction monitoring (MRM) MassLynx v4.1 with TargetLynx Product ion (m/z) 55 414 83 11 265 223 234 186 Cone voltage (V) 6 6 55 55 3 3 45 45 Collision energy (ev) 5 35 5 45 15 2 3 3 DHC 32 199 5 35 32 128 5 35 LC conditions LC system: Waters ACQUITY UPLC Column: ACQUITY UPLC HSS T3 column (2.1 x 1 mm, 1.8 µm) Column temp: 3 C Flow rate: 3 L/min. Mobile phase A: 5 mm Ammonium acetate containing.25 % formic acid in water Mobile phase B: Methanol Gradient: 15-95% B over 5 min. Injection volume: 1 L Strong Wash Solvent: Mobile phase B (8 µl) Weak Wash Solvent: Mobile phase A (24 µl) BUP-D4 472 59 65 5 NBUP-D3 417 83 55 45 METH-D9 319 268 35 15 EDDP-D3 281 234 45 3 DHC-D6 38 22 5 35 Table 1. MRM conditions used for all compounds and their internal standards. Bold transitions used as the quantifier ion. Results and Discussion The MRM conditions used for the measurement of all compounds of interest and their respective internal standards are summarised in Table 1. Figure 2 shows the MRM chromatograms obtained from a 5 µl injection of a low level urine calibrator (5 ng/ml for METH, EDDP & DHC, 5 ng/ml for BUP & NBUP). The quantifier/qualifier ion ratios for all compounds were monitored for all calibrators, QC s and samples and were found to be within ±2% of the target ion ratios.

1 1 1 1 1 1 1 1 1 1 % BUP 2.5 3. 3.5 4. 4.5 5. BUP 2.5 3. 3.5 4. 4.5 5. METH 2.5 3. 3.5 4. 4.5 5. METH 2.5 3. 3.5 4. 4.5 5. EDDP 2.5 3. 3.5 4. 4.5 5. EDDP 2.5 3. 3.5 4. 4.5 5. NBUP 2.5 3. 3.5 4. 4.5 5. NBUP 2.5 3. 3.5 4. 4.5 5. DHC 2.5 3. 3.5 4. 4.5 5. DHC 2.5 3. 3.5 4. 4.5 5. min Figure 2. MRM chromatograms for qualifier and quantifier ions obtained from a low level calibrator. The upper trace is the qualifier ion and the lower trace is the quantifier ion chromatogram for each compound. A calibration curve (25-25 ng/ml for METH, EDDP & DHC, 2.5-25 ng/ml for BUP & NBUP) was prepared by adding all the compounds to blank urine. Calibrators and QC s were prepared by the same procedure as previously described for the samples. Quantitation was performed by the integration of the area under the peak of the specific MRM chromatogram. Figure 3 shows a typical standard curve for all compounds in urine. Calibrators were plotted using 1/x weighting and found to be linear for all compounds, over the investigated range (coefficient of determination r 2 = >.997). Limits of detection were.5 ng/ml for EDDP, 1ng/mL for METH & DHC and 2 ng/ml for BUP & NBUP, all of which were acceptable for this analysis. Intra-day precision and accuracy were assessed by adding all the compounds to blank urine (n=5) at three QC concentrations ( 7.5, 5 a n d 2 n g /m L f o r B U P & N B U P a n d 75,5 a n d 2 ng/ml for METH, EDDP & DHC). Inter-day precision was assessed by analysing the QC samples in duplicate on five different days. Intra and inter-day precision and accuracy were found to be good, with precision CV s <14% and accuracy between 96-115 %, as shown in Table 2. QC Level (ng/ml) Intra-day Accuracy (%) Intra-day Precision (% RSD) Inter-day Accuracy (%) Inter-day Precision (% RSD) BUP 7.5 115.1 6.4 114.7 5.8 5 11.2 3.2 113.8 4.5 2 96.4 2.7 99.7 5.3 NBUP 7.5 12.2 6.1 11.1 13.9 5 17.5 6.7 11.2 5.5 2 97. 8.9 13.5 6.7 METH 75 98.8 7.5 98.5 6.2 5 99. 5.6 99.9 5.5 2 13.4 3.4 13.2 4. EDDP 75 96.8 6.4 11. 7.3 5 1.5 4.7 1.4 5.2 2 12.2 3.1 12.9 7.6 DHC 75 11.4 5. 12.6 7.2 5 18.4 5.4 1.4 6.9 2 11.6 1.9 1.9 5.2 Table 2. Intra and inter-day precision and accuracy for all the compounds of interest at 3 QC levels across the calibration range.

Compound name: BUPRENORPHINE Correlation coefficient: r =.998533, r^2 =.99768 Calibration curve: 1.6468 * x +.56876 type: Internal Std ( Ref 7 ), Area * ( IS Conc. / IS Area ) 2 5 1 15 2 25 Compound name: NORBUPRENORPHINE Correlation coefficient: r =.998364, r^2 =.996731 Calibration curve: 1.1168 * x +.125856 type: Internal Std ( Ref 8 ), Area * ( IS Conc. / IS Area ) 1 1 1 A 1. 2. 3. 4. 5. 6. B 1. 2. 3. 4. 5. 6. C 2 5 1 15 2 25 Compound name: METHADONE Correlation coefficient: r =.999221, r^2 =.998442 Calibration curve:.272741 * x + -.653811 type: Internal Std ( Ref 9 ), Area * ( IS Conc. / IS Area ) 5 1 15 2 25 Compound name: EDDP Correlation coefficient: r =.999259, r^2 =.998519 Calibration curve:.389288 * x + -1.25946 type: Internal Std ( Ref 1 ), Area * ( IS Conc. / IS Area ) 5 1 5 1 15 2 25 Compound name: DIHYDROCODEINE Correlation coefficient: r =.999667, r^2 =.999333 Calibration curve:.28597 * x + -.282692 type: Internal Std ( Ref 11 ), Area * ( IS Conc. / IS Area ) 5 5 1 15 2 25 Figure 3. Typical calibration curves obtained for all compounds of interest. 1 % 1. 2. 3. 4. 5. 6. D 1. 2. 3. 4. 5. 6. min Figure 4. Chromatograms showing the post-column infusion of METH (A+B) and DHC (C+D) at 1 ng/ml, during the injection of solvent blank (A+C) and a prepared urine blank (B+D). Red arrows show the elution position of both compounds. The stability of prepared samples and calibrators were assessed over 24 hours. A prepared calibrator (5/5 ng/ml, BUP & NBUP/ METH, EDDP & DHC) was stored at 5 C in the dark in the ACQUITY sample manager and an injection performed every hour. No significant changes in absolute peak area were found for any of the compounds over the investigated time period. Matrix effects were assessed in 2 ways, firstly a post-column infusion of all compounds was performed during the injection of a solvent blank and prepared urine (n=5). An example is shown in Figure 4. BUP and NBUP showed some areas of ion suppression in all samples at the same retention time as the compounds. To investigate this further, a second type of experiment was performed by spiking blank prepared patient samples (n=7) with all compounds and comparing the absolute peak areas against the equivalent concentration of calibrator in solvent. The average matrix effects were found to be acceptable for METH, EDDP & DHC but BUP & NBUP showed a significant degree of matrix effects; -39% and +19.3%, respectively. Therefore, deuterated internal standards were used in all calibrator, QC s and samples to minimise the impact of the measured matrix effects on the data quality.

The utility of the newly-developed UPLC/MS/MS method was demonstrated by the analysis of 58 authentic samples. These samples had been previously analysed at Concateno plc, using two separate LC/MS/MS assays i.e., one assay for BUP and its main metabolite (NBUP) and one for METH and its main metabolite (EDDP). The BUP, NBUP assay comprised a fairly lengthy sample preparation step including enzymatic hydrolysis and solid-phase extraction (SPE); total preparation time was approximately 3.5 hours/batch. Final analysis was then performed using a 7 minute LC/MS/MS method 6. The in-house METH, EDDP assay comprised a simple urine dilution with.5 hour total preparation time for a sample batch followed by final analysis using a 5 minute LC/MS/ MS method. These urine samples were subsequently analysed using the newlydeveloped technique. The same preparation protocol (enzymatic hydrolysis followed by LLE; total preparation time estimated at 2 hours/batch) was suitable for all of the analytes of interest and was followed by the UPLC/MS/MS assay which monitored all compounds simultaneously in a single 6.5 minute run time. Preliminary results showed that many samples contained METH and EDDP concentrations which were above the calibration range used. For accurate quantification, these samples required dilution and reanalysis. In order to reduce the need for reanalysis, additional experiments were performed to assess the linearity of the method for METH and EDDP over an extended analytical range. The responses for these two analytes were found to be linear to 25, ng/ml. When all the high samples were re-quantified using the extended calibration series, quantitative results were comparable to those diluted and reanalysed, thus minimising reanalysis. Overall, the single UPLC/MS/MS method showed very good agreement with the results obtained from the previously desc ribed proc edures ( Figure 5). T he cor rel ations ranged from r 2 =.956.995 for METH, EDDP, BUP and NBUP. In respect to DHC, no suitably quantified patient samples could be obtained. Samples (n=2) containing DHC that had been qualitatively analysed using thin layer chromatography were obtained and analysed using the newly developed method. The qualitative results showed good comparison. UPLC/MS/MS (ng/ml) UPLC/MS/MS (ng/ml) 25 2 15 1 5 3 2 1 Figure 5. Analysis of METH and BUP concentrations in patient samples by Concateno plc and the developed Waters UPLC/MS/MS method. Conclusions Methadone y =.9867x + 37.452 R 2 =.9978 5 1 15 2 25 LC/MS/MS (ng/ml) Buprenorphine y =.9232x + 5.1416 R 2 =.9793 1 2 3 LC/MS/MS (ng/ml) The developed method has been shown to be accurate and precise in the measurement of all the compounds of interest with a single analysis that takes only 6.5 minutes. The method was successfully applied to the analysis of patient samples and quantitative results showed good correlation to an established method for methadone, EDDP, buprenorphine and norbuprenorphine. This method allows the rapid urine analysis of patients in opioid dependency therapy and having all treatment drugs in one single method, removes the issue of changing between multiple methodologies in the determination of three prescribed treatment drugs. The use of one assay for the analysis of these treatment drugs offers significant time saving benefits, including a fifty percent reduction in sample preparation time, which provides increased productivity and profitability for the analytical laboratory.

ACKNOWLEDGEMENTS George Waite, Salford Royal NHS Foundation Trust Hospital (Manchester, UK) for supplying anonymous patient samples containing dihydrocodeine. References 1. Degenhardt L, Hall MD, Warner-Smith M, Lynskey M. Geneva: World Health Organisation, 24; 119-75. 2. Mattick RP, Hall WD. Lancet 1996; 347: 97-1. 3. Mattick RP, Kimber J, Breen C, Davoli M. Cochrane Database Syst Rev 28; 2: CD227. 4. NICE technology appraisal guidance 114. www.nice.org.uk/ta114. 5. Robertson JR, Raab GM, Bruce M, McKenzie JS, Storkey HR, Salter A. Addiction 26; 11: 1752-59. 6. Polettini A, Huestis MA. J. Chromatogr. B, 21; 754: 447 459. Austria and European Export (Central South Eastern Europe, CIS and Middle East) 43 1 877 18 7, Australia 61 2 9933 1777, Belgium 32 2 726 1, Brazil 55 11 4134 3788, Canada 1 8 252 4752 x225, China 86 21 6879 5888, CIS/Russia +497 727 449/29 9737, Czech Republic 42 2 617 1 1384, Denmark 45 46 59 88, Finland 358 9 5659 6288, France 33 1 3 48 72, Germany 49 6196 46, Hong Kong 852 29 64 18, Hungary 36 1 35 586, India and India Subcontinent 91 8 2837 19, Ireland 353 1 448 15, Italy 39 2 265 983, Japan 81 3 3471 7191, Korea 82 2 63 48, Mexico 52 55 5524 7636, The Netherlands 31 76 58 72, Norway 47 6 384 6 5, Poland 48 22 833 44, Puerto Rico 1 787 747 8445, Singapore 65 6273 7997, Spain 34 93 6 93, Sweden 46 8 555 11 5, Switzerland 41 56 676 7, Taiwan 886 2 2543 1898, United Kingdom 44 28 238 61, All other countries: Waters Corporation U.S.A. 1 58 478 2/1 8 252 4752 29 Waters Corporation. ACQUITY, UPLC, Ultra Performance LC, T-Wave, MassLynx, TargetLynx and The Science of What s Possible are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. June 29 7235EN KK-PDF Waters Corporation 34 Maple Street Milford, MA 1757 U.S.A. T: 1 58 478 2 F: 1 58 872 199 www.waters.com