ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Section: R100 Bulletin: R Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System

Fire Pump Controllers Remote Alarm Panels

Considering the alternatives to the McDonnell & Miller Series 150 mercury LWCO?

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

FLASH TANK ECONOMIZER PRODUCT GUIDE

In-Line Electronic Flow Switches

Electronic Flow Switches

Electrical Circuits Types of Electrical Switches Switch Operation Standard Combinations... 6

BASIC WIRING Electrical Circuits Types of Electrical Switches Switch Operation Standard Combinations...144

Model DE-3 Air Release Head

I. STEAM GENERATION, BOILER TYPES

Factory owners must ensure the boiler is:

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

The city of Milwaukee s Sample Preventative maintenance manual for Electronically monitored boilers

Water Leak Detection System

Chicago Stationary Engineer Licensure Examination Information

Sanitary Type Electronic Flow Switches

Some Criteria for Choosing a Steam Boiler for a Microbrewery

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

SELF-POWERED VOLTAGE DETECTING & PROTECTING RELAY

Boiler & Pressure Vessel Inspection discrepancies and failures

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Galvanic Parts Per Million Dissolved Oxygen Systems

Guidelines for Preparing for a Temporary Steam Plant

Boiler Blowdown. Boiler Blowdown Benefits. Best Operating Practices for Boiler Blowdown

Routine and Emergency Boiler Operation

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:

Boiler Preparation, Start-Up and Shutdown

GUIDELINES FOR LOGBOOKS COMPLIANCE TO BOILER REGULATIONS N.J.A.C. 12:90

Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold

Expert Report. History of the development of water level control in steam- and hot water boilers

IGEMA BOILER LEVEL & TDS CONTROLS

MODEL FLX PACKAGED BOILER

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

DC400 Dispensing Cutoff System

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

In-Line Electronic Flow Switches

Overview of Heat Recovery Boiler Systems and Operating Costs Factors Effecting Blowdown Blowdown Heat Recovery The Energy Tank

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

WD600 STEAM TRAPS. Thermodynamic Steam Trap

SCOTCH MARINE FIRETUBE STEAM BOILER MANUAL 3-Pass & 4-Pass Wetback High & Low Pressures BoHP Gas / Oil / Gas & Oil

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Mobrey Hydrastep and Hydratect

CO2 Alarm. Operation. Application

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Advantium 2 Plus Alarm

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

Commercial Semi-Instantaneous Water Heaters

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

COLUMBIA MULTI-PASS HORIZONTAL BOILER MPH SERIES INSTALLATION, OPERATION

REQUEST FOR QUOTATIONS

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

MAC-120HE-01 Air-Cooled Chiller

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Bolted contact switches. Pringle switches

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

WD-AMX Water Detection Controllers

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

INSTALLATION, OPERATION, MAINTENANCE AND PARTS MANUAL 'J' SERIES - GAS FIRED STEAM BOILERS (6J - 60J)

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

BOILER ROOM GUIDE. Reference Guide

SIOUX HYBRID WATER HEATER

Morrison Bros. Co. General Product Specifications

Conlift1, Conlift2, Conlift2 ph+

HYDRAULIC AND LUBE OIL HEATERS HYDRAULIC AND LUBE OIL HEATERS. HL Series. Warren Electric Corporation

Condensate water pump with neutralisation system

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Thermatel Model TA1 Mass Flow Transmitter

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

Laboratory & Scientific Line. Horizontal Steam Sterilizers

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

MM-825(A) McDonnell & Miller General Catalog

SURGICAL SCRUB SINKS INSTALATION-OPERATION-MAINTENANCE USER MANUAL

Cooling Capacity CFM in. w.c. (125 Pa)

Electronic, Digital and Mechanical Vibration Switches

Cooling Capacity CFM in. w.c. (125 Pa)


The First Line of Safety

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

Streaming Potential System (SPT1000, SPD1000)

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

Steam System Efficiency. Bill Lumsden Leidos Engineering

INSTALLATION INSTRUCTIONS MC95HAE-1 MASTER CONTROLLER

Transcription:

SPC 1000 Single Point Control ABC-1000 Retropak Section: F100 Bulletin: 100.2 Date: 03/09 Supercedes: 5/01 Features and Benefits Design pressure to 450 WSP Meets ASME, CSD-1 Requirements LED Monitoring High current load electromechanical relays allow for easy control of pump and alarm circuits Built in Positive Blow Down Indicator TM assures proper blow down while maintaining uninterrupted boiler service Self diagnostic capability is standard - the result is enhanced safety Electronics can be remotely mounted for added flexibility No floats, linkages or mercury switches Automatic reset feature is standard, manual reset available Gage glass and gage glass cocks can be supplied as an option The ABC-1000, Automatic Boiler Level Controller, is a microprocessor based device designed to maintain optimum feed-water level in a boiler, provide low water level alarm and fuel cut off. Personnel and equipment safety are its primary functions. This device is intended for use on Package Boiler Systems with a maximum design pressure of 450 psig. ABC1000 Controller Board The ABC-1000 meets all requirements for level control and fuel cut off contained in ASME CSD-1 for automatically fired boilers.

Column Designator A B C D E F G H Weight (lbs) Steam& Water Connections 06T 1" 16" 4 7/8" 1/2" 11 1/2" 2 5/8" 2 1/4" NA 30 Top & Bottom 08T 1 1/4" 16" 4 7/8" 1/2" 11 1/2" 2 5/8" 2 1/4" NA 30 Top & Bottom 11T 1" 17" 5 7/8" 1/2" 11 1/2" 3 5/8" 2 1/4" NA 32 Top & Bottom 22T 1 1/4" 17" 5 7/8" 3/4" 12 3/4" 2 3/8" 3 1/2" NA 32 Top & Bottom 33T 1" 17" 5 7/8" 1/2" 11 1/2" 3 5/8" 2 1/4" 2" 32 Top and Side Column 33T with side outlet water connection, bottom connection will be plugged. Probe Housing 2.125 Spare 4th Probe Location (3/8 NPT) D (NPT) Top View A (NPT) 3.500 E B 3.500 0.750 A L M H HH A 0.750 C G L - low water cut off M - pump on H - pump off HH - spare (plugged) H F A (NPT) Optional side outlet water connection column 33T only, (1 NPT) Section A-A

Specifications ABC-1000 Electronics: Input Voltage 115 VAC, 50-60Hz Maximum Ambient Temperature: 60 o C /140 o F Contact Ratings: Pump Circuit N.O. N.C. 115 VAC 16FLA/60LRA 5.8FLA/34.8LRA 230 VAC 12FLA/50LRA 4.9 FLA/20LRA Contact Ratings: Alarm/Fuel Cutoff N.O. N.C. 115 VAC 20A Resistive 10A Resistive 230 VAC 20A Resistive 10A Resistive Contacts: 2 SPDT Time Delay: 0-30 sec. delay on make and break for both pump and alarm relays Reset Options: Automatic or Manual Approvals: Probe Column: Standard Column Material: Carbon Steel - ASTM A106B - ASTM A285C Probe Connection: Integral 3/8 FNPT Gage Glass Connection; 1/2 FNPT or 3/4 FNPT Steam and Water 1 or 1 1/4 FNPT Top and Connections: Bottom or Top and Side Maximum Design Pressure: 450 PSIG How to Order Contact your local Sales Representative or Clark-Reliance Model Number Code: RABC1000 - - Time Delay in Seconds (00,01,02,04,08,16,30) Column Designator (06T, 08T, 011T, 022T, 033T)

SPC-1000 Single Point Control Specifications SPC-1000 Electronics: Input Voltage 115 VAC, 50-60Hz Maximum Ambient Temperature: 60 o C /140 o F Contact Ratings: Alarm/Fuel Cutoff N.O. N.C. 115 VAC 20A Resistive 10A Resistive 230 VAC 20A Resistive 10A Resistive Contacts: Time Delay: Reset: Approvals: Probe Connection: Steam and Water Connection: Controller: 1 SPDT 0, 3, 5 sec. Delay on make and break Manual Integral 3/8 FNPT 1 MNPT Open Circuit Board Features and Benefits Meets ASME, CSD-1 requirements LED Monitoring Adjustable Time Delay Use as Low Water Cut Off, High Water Alarm or any Single Point Level Application Valve Control, Pump Control, Alarms Safety Interlock Maximum Design Pressure: 450 PSIG The SPC-1000 meets all requirements for level control and fuel cut off contained in ASME CSD-1 for automatically fired boilers. How to Order Contact your local Sales Representative or Clark-Reliance Assembly Model Number: RSPC1000 - - - _P Time Delay in Seconds (00,03,05) Probe Length (feet): 2, 3, 4, 5, 6 Controller Model Number Time Delay in Seconds (00,03,05) Probe and Housing Model Number: Probe Length (feet): 2, 3, 4, 5, 6 Replacement Probe Part Number: Probe Length (feet): 2, 3, 4, 5, 6 RSPC1000 - - RSPC- P RPABC- P

ABC - 1000 Retropak Specifications The ABC-1000 Retropak is a simple way to upgrade boiler controls for enhanced safety and performance while at the same time reducing routine repair costs. An additional benefit is that this device eliminates mercury switches and snap-action switches while maintaining the electrical contact ratings of your existing equipment. Contact ratings of each circuit are listed on page three of this catalog. Over the past 50 years many boilers have been supplied with float-type controls, as shown below, (see figure 1). The ABC-1000 Retropak maintains current contact point and is easily installed on the existing water column via an adaptor flange, (see figure 2). This 10 minute conversion results in a conductivity probe based system (see figure 3) with all the features and benefits of the ABC-1000 control unit while at the same time eliminating moving parts, bellows, floats and mercury/snap switches. 12:00 12:05 12:10 Figure 1 Figure 2 Figure 3 Notes: Maximum design pressure of the ABC-1000 Retropak is limited to the maximum design pressure of the attached pressure vessel- up to 450 PSIG. 120 vac power supply needed. How to Order Contact your local Sales Representative or Clark-Reliance Model Number Code: RABC1000 - - FP Time Delay in Seconds (00,01,02,04,08,16,30)

Separate SPC-1000 with Manual reset Water Column (ABC-1000) Pump Control and Low Water Cut-Off (ABC-1000) Condensate Receiver Alarm Boiler Feed Pump Burner High High Alarm ABC 1000 LWCO Alarm Feedwater Pump To Fuel Cut Off Typical Boiler Level Control Arrangements Burner