Owner's Copy. 104873 December 14, 2011 ELECTRICAL INSTRUCTIONS FOR ADVANTEX EA OR EX MODELS



Similar documents
INSTALLATION INSTRUCTIONS FOR ARCHITECTURAL VALUE SERIES DELAYED EGRESS AND "H" MODELS (HURRICANE) Endcap P/N:

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Model 2300DR Installation Guide

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Wiper Motor Marinco 2.5. Installation Instructions

Life Safety, Security Door Hardware and Integrated Door Security Systems

1R / 4-BUTTON SERIES

TS93 EMR T/PT/TDE. Surface applied door closer

Adaptability to Enhanced Security

Adaptability to Enhanced Security

Wireless Home Security Alarm System AM 500

OPL BASIC. Dosing System for Professional Laundry machines. Contents

MODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system way pager system

How To Control A Car Alarm On A Car With A Remote Control System

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV Kit Number. Models. Additional Parts Required. Kit Contents

AC-115 Compact Networked Single Door Controller. Installation and User Manual

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

MODELS 7007 Gorilla Cycle Alarm 7017 Gorilla Cycle Alarm with 2-way pager system way pager system

CONTENTS TOOLS REQUIRED: Ratchet 13mm Socket 10mm Socket Phillips Screwdriver Pliers Panel Removal Tool. Amp Installation

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

VEHICLE SECURITY SYSTEM G25/G20

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

PRO PLM Installation Instructions

TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N

Advantium 2 Plus Alarm

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Exit Devices TABLE OF CONTENTS

WIRELESS HOME ALARM SYSTEM (WHA1)

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

INSTALLATION INSTRUCTIONS

Mobile Satellite Solutions. A WiWorld Partner SATELLITE TV ANTENNA CONTROLLER RFM-1000/1100 TECHNICAL MANUAL STOW SEARCH

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

Cooktop Low-Profile Ventilation Hoods

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

TS510 & TS500. Installation & User Guide. Compatible Equipment

Wireless Home Security System Product Manual (Model #80355)

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Networkfleet 3500 Product Line Installation Guide

INSTALLATION INSTRUCTIONS

CAD-05 Kit GSM Auto Dialer. Owner s Manual

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter

SECURITY SYSTEM SMART SIREN KIT

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

TRIMBLE TX5 3D LASER SCANNER QUICK START GUIDE

GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois U.S.A. tel: fax: @gaertnerscientific.

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

2M IR Mini Dome Quick Installation Guide

e-ask electronic Access Security Keyless-entry

Installation Instructions for FT-10 Network PowerCommand ATS Communication Module (NCM) Kits and

KEYPAD LOCK RETROFIT KIT

Business/Home GSM Alarm System. Installation and User Manual

How To Program An Autodialer

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

8900 EMR (WITH DETECTOR)

GENUINE PARTS INSTALLATION INSTRUCTIONS

SR-i900 Series. Phone (480)

Electrified Products TABLE OF CONTENTS. Power Transfers...12 Pressure Sense Bars...12 Proximity Cards & Keys... 4

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Chevy Equinox / GMC Terrain (with monochrome display) G

GPS AutoSteer System Installation Manual

Quick Installation Guide LCD GSM ALARM SYSTEM LH

No Rainfall Data is Collected

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

INSTALLATION INSTRUCTIONS

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200

The Child Reminder System Installation Manual

Digital Keypad Use s Manual

User Guide. Model: MAS-WA-SYS

INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM

Manual for Fire Suppression & Methane Detection System

Auto Sentry-eXP Maintenance

VEHICLE THEFT/SECURITY SYSTEMS

Companion Service Guide

INSTALLATION INSTRUCTIONS

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

INSTALLATION AND OPERATION MANUAL

Schlage Control Smart Locks

Procenter Delivery System* Troubleshooting Charts

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Keypad Locks User Guide

Remote Access System Installation

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

Alarm Security Kit - NVR

INSTALLATION INSTRUCTIONS

The $25 Son of a cheap timer This is not suitable for a beginner. You must have soldering skills in order to build this kit.

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

Business/ Home GSM Alarm System

SEC-ALARM200 WIRELESS ALARM SYSTEM

Car Alarm Series 2 B 2 Buttons

Transcription:

104873 December 14, 2011 Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)629-2900 / 1-800-729-3839 / Fax (830)620-6711 E-MAIL: detex@detex.com INTERNET: www.detex.com ELECTRICAL INSTRUCTIONS FOR ADVANTEX EA OR EX MODELS Rim, SVR, CVR & Mortise EA - Exit Alarm EX - Request to exit EXxW - Request to exit, weatherized EXV - Request to exit, voltage EXVxW - Request to exit, voltage, weatherized Dwg #: 101379 RIM (SS) 104600 RIM (AL) 101559 SVR (SS) 104690 SVR (AL) 103200 MORTISE (SS) 104695 MORTISE (AL) 105260 CVR (60) 105280 CVR (70/80) EC1 Endcap P/N: 101642-X EC1 Endcap (for FCA) P/N: 102095-X EC1 Endcap Bracket P/N: 100147 (shown) EC1 Endcap Bracket with 9V battery holder P/N: 101093 Fillerplate SubAssembly (EA x CD) P/N: 100860-X Hex Nut P/N: 100783 9V Battery P/N: PP-5567 EC2 Endcap (S.S.) P/N: 104304-X EC2 Endcap (AL) P/N: 104612-X EC2 Endcap (AL) (for FCA) P/N: 104686-X EC2 Endcap (S.S.) (for FCA) P/N: 104317-X Door Sign P/N: EA-561 (electrified versions only) EC2 Endcap Bracket P/N: 104303 EC2 Endcap Bracket with 9V battery holder P/N: 104636 * Note: Parts listed above will vary according to product configuration. Mortise cylinder available as an option. Standard Yale type cam required. See Mortise cylinder installation page. Owner's Copy 104873 Page 1

"EA" ALARM OPERATIONS Note: Unit is shipped with Disable Auto Rearm turned ON and Status Indicator turned OFF Refer to tables 1, 2 & 3 on page 3 Red LED PushPad Siren (LHR shown) Mortise cylinder Green LED SPECIAL NOTES and DEFINITIONS 1. When operating the ON/OFF switch, there is a slight delay. 2. The key is inserted and removed only in the horizontal position (home position). 3. Key function: counter clockwise (CCW) = Armed; clockwise (CW) = Disarmed 4. The power needs to be removed to register changes in the slide switches. a. Status Indicator (This will affect battery life) b. Disable Auto Rearm c. Dis Lo Bat INDicator UNIT ARMING TEST: 1. Turn key counterclockwise (CCW) (key is removable after rotating back to horizontal position) 2. Red LED will flash twice, then green LED will illuminate for the 15 second delay time, then turn off. The siren will sound three short beeps indicating the unit is armed. 3. Depress Pushpad (Siren will sound and red LED will illuminate) 4. Turn key clockwise (CW). Turns alarm off. Figure 1. Device features. LOW BATTERY ALERT: 1. Siren will beep and red LED will blink at approximately 45 second intervals when battery is low DOGGING FEATURE: (non-fire rated units only) 1. Depress Pushpad 2. While holding Pushpad depressed, turn key clockwise (CW). Pushpad should remain depressed (Key is removable after rotating back to horizontal position) 3. Unit is now disarmed. STATUS INDICATOR 1. Slide the switch to ON and apply power. 2. If the unit is armed, the red LED will blink every 15 seconds. 3. If the unit is disarmed, the green LED will blink every 15 seconds. Disable AUTO REARM (Off) 1. When the unit is in full alarm and the bar is released, the alarm will shut off after 2 minutes. Care and Maintenance: R The Detex Advantex devices are designed to provide many years of maintenance free service under normal usage. Periodically inspect and lubricate the unit to extend its life. 104873 Page 2

"EA" SWITCH OPTIONS Switch selections must be made before applying power or installing battery (See Figure 1) Status Indicator Off * On Disable Auto rearm On * Off Disable Low Battery Off * On Alarm sounds until turned off with key. Extended bypass is enabled. Table 1 Figure 1. Selector switches detail Status Description The Device gives no indication of armed or disarmed status. The Device flashes red or green LED every 15 seconds. Red indicates armed status and green indicates disarmed. Table 2 Auto Rearming Feature Setting Unit sounds alarm for 2 minutes after bar is released. Alarm will automatically rearm after 2 minutes. Table 3 Note: AC power must be applied for switch to operate Status Description The device flashes one red LED and one beep about every 45 seconds The device gives no indication of battery being low. (EA shown) See Table 3 See Table 2 See Table 1 ON ON ON Dis Lo Bat STATUS Disable INDICATOR AUTO REARM * Factory default settings: STATUS INDICATOR switch set to "OFF" Disable AUTO REARM switch set to "ON" Dis Lo Bat switch set to "OFF" Figure 2. EA wiring detail Battery Connector (Standard) J2 J1 P2 P1 12/24 V AC/DC External Supply (sold separately) (24V AC/DC Optional) Bypass/Remote Signal (Optional) Protect wires to avoid pinching Table 4 (P1 wire usage) Remote Signal Remote Bypass Pin 1 Pin 2 Pin 3 Brown Common Pin 4 Violet N.O. contact Yellow Normally Open Pin 5 Violet N.O. contact Green Normally Closed Pin 6 ---- ---- Contacts rated at 1.0A @ 30VDC or 0.5A @ 125VAC 1 2 3 4 5 6 Figure 3. P1 detail 104873 Page 3

Slide endcap assembly onto extrusion CHECKING FOR DEVICE CLEARANCE (Cut-Off procedure if required) 1 CAUTION: Check for device and door frame clearance. If no cut-off needed, proceed to the next page. 2 Cut fillerplate and extrusion STRAIGHT & SQUARE to desired length and deburr L Secure with tape before cutting Minimum Fillerplate Length Type LX x LD LX x (HD/CD) EA Length (L) 2-1/2" 3" 7-1/2" For aluminum Advantex finish cutdown applications: After cutting, the baseplate extrusion can be reversed to place the cut end inside the head cover. To do so, loosen the setscrew inside the aluminum baseplate extrusion and slide extrusion out, reverse, & slide back in. Tighten setscrew. Cylinder nut socket p/n 103779 (sold separately) Dogging Assembly MORTISE CYLINDER INSTALLATION CD (Cylinder Dogging) Cylinder Installation Spacers Fillerplate Mortise Cylinder Endcap Mortise Cylinder with standard Yale cam required Figure A1 Endcap Mounting Bracket Follow steps "a" through "g" for EA installations a. Remove endcap and endcap mounting bracket. b. Remove fillerplate. c. Remove and discard shipping insert and nut. Loosen (2) screws from dogging assembly. d. Install mortise cylinder (sold separately) with large hex nut provided. e. Trial fit dogging assembly. If cylinder is too short, remove spacers as necessary and reattach them under the (2) screw heads (See Figure A1). Fasten the (2) screws to the rest of the assembly. NOTE: The key should easily turn in both directions. f. Rotate key counterclockwise g. Assembly complete. Continue with Panic Hardware instruction. 104873 Page 4

"EX" Wiring Instruction Fillerplate Subassembly Endcap (EC1 shown, EC2 available) EX, EXxW (0.1A) Wire Color Connection Brown/White Common Gray/White Closed Yellow/White Open EXV (3A), EXVxW (5A) Wire Color Connection Brown/Black Common Gray/Black Closed Yellow/Black Open POWER TRANSFER OPTIONS Note: For high traffic areas an electric through-wire hinge or power transfer is recommended. Electric Hinge p/n: EWH8-X Power Transfer p/n: PT-5 Flex Conduit/End Cap Kit p/n: FCA (Order FCA x Finish) (EC1 shown) OPTION 1 OPTION 2 Electric Hinge Endcap Prep Power Transfer Endcap Prep (By Others) (By Others) OPTION 3 FCA Flex Conduit Endcap Prep (Optional Accessory) Wire chase through door Wire chase through door 1/2" hole through the inside door face (EC1 shown) 1/2" hole through the inside door face FLEX CONDUIT INSTALLATION (See Appendix A for catalog number) Adjust for Handing (LHR shown) (EC1 shown) 104873 Page 5

Advantex EA Troubleshooting Tips for Default Setting Problem When unit is armed, red LED flashes twice, green LED is on for 15 seconds, but the unit does not give three beeps after the green LED goes off. Probable Cause The actuator is sticking to the micro switch. Action Call Detex. 1-800-729-3839 No LED activity when key is turned ccw to armed position. Dead or weak battery. Battery not secured to connector correctly. Battery connector or wires damaged. Install new battery, LED's should flash and the siren beep once. Secure battery correctly. Call Detex. 1-800-729-3839 AC powered unit gives a low battery indication. LED's do not flash to indicate armed or disarmed status. No AC power. Battery not installed. OR Low battery Status indicator switch in off position. Technical Support 1-800-729-3839 Verify power from transformer and check for correct voltage at connector P2. Install battery. If battery is not desired, disconnect power and slide the 'Dis Lo Bat IND' switch to 'ON' position. Remove power from unit. Slide 'Status indicator' switch to 'ON' position. Reinstall power. 104873 Page 6

Appendix A Optional Accessories Advantex Flex Conduit Kit Catalog No: FCA-[Specify Finish] Electrical Wires Not Supplied (EC1 endcap) (EC2 endcap) Note: For high traffic areas an electric through-wire hinge or power transfer is recommended. Flex Conduit Kit Catalog No: FCV-W-3 or FCV-W-10 Waterproof Connectors Provided Tamper Kit Security Kit - Rim, Catalog No: SSK1 SVR, Catalog No: SSK2 Mortise, Catalog No: SSK3 Security Screws R Security Pin TORX Bits provided Key Stop Kit (Momentary Shunt) Catalog No: KS Dogging Lever Assembly (shown for reference ONLY) Key Stop Screw 104873 Page 7