Installation Instructions For Aurora LED Accent Housing 3 Round & Square Trimless AL2-ARE3 & AL2-ASE3. Fig.1 Complete Fixture

Similar documents
WORKFLOW CHART. Installation Instructions For Genna LED 3.5 Wall Wash. Housing and Plaster Plate. General Information. Genna Trim and LED Module

Connecting the Channel A

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

id led 4" square housing FL44

id led square housing FL44


INSTALLATION GUIDE TH STREET SACRAMENTO, CA U.S.A TOLL FREE PHONE

DISPLAY & EXH I B I T

Determine the desired location fixture and center the coaxial cord location to the electrical box.

DE Frame with C Series Sidelight

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Triac Printed Circuit Board Replacement

INSTALLATION INSTRUCTIONS

1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Ceiling Fan Installation Instructions

Light fixtures are attached permanently to

Panel Track Installation Guide

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

NATIONAL INSTITUTE OF BIOLOGICALS

Horizontal Mini Blinds Installation Guide

LED MOTION ACTIVATED FLOOD LIGHT

Beadboard Wall Bookcase

WARNING! DO NOT ATTEMPT TO INSTALL THIS KIT IN A POWERED CONVEYOR.

All-Season Sunroom Sliding Glass Door Installation Instructions

Customer Service or visit us online at smithnoble.com. Wood Shutters. Step by Step Installation. Troubleshooting Tips

Smart Cam, CC-Smart-Cam, and Smart Cam Packages Installation and Quick Start Operating Instructions

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

LUCCI AIRFUSION QUEST II CEILING FAN

60" TulleTM. Instruction Manual. A Kichler Select ceiling fan

HALO H27RICT. 6" RECESSED DOWNLIGHTING Incandescent. eliminate need for separate wire nuts - simply strip supply wires and push in

TECHNICAL INFORMATION

Hollow or Cinder Block Wall Mount Job Aid

Wiper Motor Marinco 2.5. Installation Instructions

INSTALLATION INSTRUCTIONS

ECM-D70T / ECM-D70T1.5

SAN FRANCISCO. U.S. Patents: 5,951,253; 6,158,964; 6,171,060; 6,250,885 INSTRUCTION MANUAL WARRANTY CERTIFICATE

HOW TO INSTALL A BEAUTIFUL NEW KITCHEN

Atlanta CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. IF UNSURE CONSULT A QUALIFIED ELECTRICIAN

Digital TV Coat Hanger Antenna

Installation Instructions

DIY Y6. Build Manual V.A 2014

AutoDome Easy II. VEZ Series. Mounting Manual

5800 Temperature Sensor Cable Assembly

QWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS

POD Visor Instructions

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

12. REAR WHEEL/BRAKE/SUSPENSION

GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois U.S.A. tel: fax: @gaertnerscientific.

Speed-Mat Rectangle Cutter

HVAC Vents & Diffusers

Electrical Wiring Technical Bulletin

Sealant. 30" Model No D: 17-7/8" TO 18-3/8" (454 to 466mm) W: 29-3/4" TO 30-1/4" (756 to 768mm) Under Countertop Installation

Andersen Electric Window Opener for Andersen Awning and Roof Windows

SPIRAL STAIR KIT INSTALLATION MANUAL

glass & Glazing Products

39HQ Airovision Air Handling Units

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

TopSky DLG Installation Manual

Picnic Table Plans. Made out of a single sheet of plywood, it s also portable! By Kevin Ayer. This children's picnic table would

Clad Direct Glaze Window Installation Instructions

Repairing Drywall Techniques for fixing everything from popped screws to big holes

CELO5. User & Installation Manual.

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

User s Manual. High Performance Fanless VGA Cooler. Model : VNF100. Please visit our website and watch the VNF100 installation video installation.

CONTENTS TOOLS REQUIRED: Ratchet 13mm Socket 10mm Socket Phillips Screwdriver Pliers Panel Removal Tool. Amp Installation

Service Guide. Gateway M275

Step by step guide to installing your own Ku Band satellite dish

Original Assembly Guide

Wren Kitchens Installation Tips Carefully check your kitchen delivery Measuring out and marking up Fitting the base cabinets...

Solstice/Sky Water Pump Replacement

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A

How to Install GoBoard:

Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows

Rack installation instructions

CortezTM A Kichler Décor Ceiling Fan

Installation Instructions

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

CRASH RAIL INSTALLATION HEIGHT

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Guidelines for Earthquake Bracing of Residential Water Heaters

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Active and Passive Sash Replacement

Traditional Sonar and DSI Sonar Installation

I BEAM TRACK INSTALLATION

Installation Instructions

Network Camera. Quick Operation Guide V4.0.1

ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec

ELECTRIC CONVECTION BUILT-IN OVEN

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Scottsdale 52 in Ceiling Fan Owne r s manual. Scottsdale Ventilador de Techo de 1,32 Manual del Propietario

Brick Veneer Construction

LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.

Reachout Lock Replacement for Andersen 2-Panel and 4-Panel 400 Series Frenchwood Gliding, 200 Series Narroline, and Perma-Shield Gliding Patio Doors

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

Transcription:

015 Pure Lighting. All Rights Reserved. Installation Instructions For Aurora LED Accent Housing 3 Round & Square Trimless AL-ARE3 & AL-ASE3 1718 W. Fullerton Ave Chicago, IL 60614 Tel: 773-770-1195 Fax: 773-935-5613 www.purelighting.com info@purelighting.com General Information Fixture must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing. Compatible only with traditional, level 5 surface finishing, not self-leveling, PVA primer systems. Not for use in wood or tile ceilings. Fig.1 Complete Fixture 6 1/16" (154mm) HOUSING ANCHOR SCREENS WORKFLOW CHART 1. Locate and mount housing. Screw and lock-in housing 3. Connect wires in housing 5 7/8" (149mm) 18 1/" (470mm) 8 7/8" (5mm) 1 1/8" (307mm) PLASTER PLATE CONTRACTOR 1. Install and cut drywall around housing. ADJUSTABLE GEARS HIDDEN BEHIND THE LAMP. 1. Adjust plaster flange frame and tighten wing nuts.. Connect the LED MR16 wiring to the plaster plate. 3. Screw plaster plate into housing. 4. Test LED MR16. CONTRACTOR 1. Plaster, sand & paint.. Clean aperture with clean damp towel. TILT GEAR Fig. Pan tilt Mechanism attached to inside of plaster plate. BACK LIGHT SHIELD HOT AIMING WITH PHILLIPS SCREWDRIVER PAN LOCK PAN ROTATION RING 1. Clean aperture with clean damp towel, where the drywall contractor missed.. Adjust pan rotation ring and aim lamp. You're done! Important Scan with your mobile device to watch the installation video or visit: www.purelighting.com/aurora-install LIGHT SPILL SHIELD 5 BULLET CATCHES SNOOT RETAINING RING LOCKING RING (INCLUDED) LED MR16 LAMP LOCKING RING (INCLUDED) Importante Escanear con el dispositivo móvil para ver el video de instalación o visite: www.purelighting.com/aurora-install Fig.3 Snoot Assembly HOT AIMING TILT SCREW SNOOT LAMP HOLDER 1

A ANCHOR SCREENS 1 5 7/8" (149mm) 14 3/4" (375mm) 8 7/8" (6mm) ALIGNMENT NOTCH B NOTE: APERTURE IS CENTERED WITH CURVES IN HOUSING. (NOT CENTER IN FIXTURE) NOTE: APERTURE IS CENTERED WITH CURVES IN HOUSING. ALIGNMENT NOTCH 1 1/8" (308mm) MUST BE FLUSH WITH JOIST 1: Use these dimensions when locating the center point of the aperture during the installation process. Align the fixture using a laser or a chalk line. NOTE: Drywall anchor screens may be removed, if the joist are less than 14 1/" apart. Refer to page 8 to shorten the hanger bars, : Hanger bars must align and remain flush with joist. C D 4 REMODEL NOTE: CUT TO MIDDLE OF JOIST. 3 3: After fixture is positioned, tighten all (10) screws on hanger bars. 4: After installation, pull on fixture to ensure there is no movement.

E INSIDE AURORA JUNCTION BOX (NOT TO SCALE) ELV DIMMER WHITE (NEUTRAL) INPUT GND BLACK (HOT) HOT NEU HOT - Neutral + Dimmable Switchleg TO NEXT FIXTURE (FOR BRANCH WIRING) *NOTE* Leave 1" of wire in the junction box for future maintenance through the f ixture aperture. INSIDE AURORA FIXTURE LED POWER SUPPLY MR16 LED LAMP WIRING DIAGRAM FOR USE WITH PURE LIGHTING AURORA NON-RGB FIXTURES 3

CONTRACTOR F Contratista hojas de pared tiene que instalar la hoja de pared y corte un aqujero 14 3/4" (375mm) X 1 1/8" (308mm) con une corte rotatorio alrededor el enseres fijo o lo corte un agujero antes que instalar. G ANCHOR SCREEN CUTOUT 5 6 ROTARY TOOL 5: Drywall contractor must install drywall and cut 14 3/4" (375mm) X 1 1/8" (308mm) hole with rotary cutting tool around fixture or pre-cut hole in drywall prior to installation. ANCHOR SCREW 6: Electrian must anchor drywall anchor screens. Insert screws through drywall into anchor screen on fixture. H I CEILING 7 PLASTER FLANGE FRAME LOOSEN WINGNUTS TO ADJUST PLASTER FLANGE FRAME 8 7: Loosen (4) wing nuts and adjust plaster flange frame to be flush with drywall. All 4 corners MUST be exactly even with drywall. Plaster flange frame adjusts to accommodate 1/" (13mm) to 1 1/4" (3mm) ceiling thickness. 8: Use a straight edge or level and move plaster flange frame up or down to be exactly even with drywall ceiling. 4

J TIGHTEN WINGNUTS TO ADJUST PLASTER FLANGE FRAME 9 K LED QUICK CONNECTOR 9 USE A PEN TO TIGHTEN LOCKING RINGS. 10 LAMP LOCKING RING LED MR16 LAMP LOUVER AND LENS LOCKING RING SNOOT LAMP HOLDER 9: Tighten (4) wing nuts securely. 10: Assemble lamp holder fixture to MR16 socket. Use a pen to tighten locking rings into place. L M 11 1 11: Loosely attach plaster plate using all (4) screws. After all (4) screws are started, go back and tighten the screws securely. 1: Check to ensure that the plaster plate is flush and even with the drywall. 5

N O 15 MR16 LED ACCENT LIGHT 14 HANDS MUST BE CLEAN WHEN ADJUSTING FIXTURE 13: Turn on and test LED MR16 to ensure it is properly installed. 14: To aim lamp, loosen pan lock, rotate and position the pan rotation ring. P Q OPEN SPACE ON RACK 16 GEAR COVER 15 17 18 TOP CLIP HANDS MUST BE CLEAN WHEN ADJUSTING FIXTURE 15: Tilt and rotate lamp assembly as needed. When lamp is properly adjusted, secure pan lock. BOTTOM CLIP 16: Measure the distance of the open space on the track. 17: Remove the protective film from the gear cover. 18: Cut the gear cover to fit the space if necessary. 6

R 1 19 APERTURE S CONTRACTOR Compatible only with traditional, level 5 surface finishing, not self-leveling, PVA primer systems. RACK GEAR COVER GEAR COVER RACK 0 Aplicar incluido Perfect Finish FibaTape Ultra-Thin Tape alrededer de los cuatro lados 19: Insert the gear cover (make sure the gear cover clips are facing the lamp assembly rack) from the bottom of the aperture. : Apply included Perfect Finish FibaTape Ultra-Thin Drywall Tape around all four sides of the plaster plate. DO NOT OVERLAP. 0: Secure by snapping in the two bottom clips of the gear cover first to the bottom edge, then snap in the top two clips to the top edge. T U 4 3 Aplique una capa delgada de Durabond 45 compuesto alrededor de todo cuatro lados de la placa de yeso Lijar superficie de yeso. Repita según sea necesario hasta que la superficie es totalmente lisa antes de pintar. 3: Apply a thin layer of Durabond 45 compound around all four sides of the plaster plate. 4: Sand plastered surface. Repeat as needed until surface is completely smooth before painting. 7

V W 7 HANDS MUST BE CLEAN WHEN ADJUSTING FIXTURE 5: Paint and finish plaster plate and wall. Remove paint shield from plaster plate 0-60 minutes after painting. 7 6: Clean all excess paint from the aperture. 7: Wash hands and clean all drywall residue from inside aperture, with a clean damp towel. Electrician or lighting designer - ensure pan rotation ring is adjusted, locked in place, and the lamp is aimed properly. SHORTENING THE HANGER BAR (ONLY FOR JOISTS SPACED LESS THAN 14.5") X HOUSING Y HOUSING HANGER ARM HANGER ARM 1 1 1 1 HANGER ARM 3 ANCHOR SCREEN 3 PHILLIPS SCREW 1: Remove the four Phillip screws on the housing to remove the two anchor screens, and put the screws back on. : Pull the hanger arms completely out of the housing. 3: Break the ends completely off hanger arms. 8

Z HOUSING HANGER ARM 4 4 4: Insert the hanger arms back into the housing, and continue to step A on page to complete instillation. 9