Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C



Similar documents
T7079A,B Solid State Remote Temperature Controllers

Y7230A CO 2 Alarm System

WD-AMX Water Detection Controllers

Q309A,B; Q335C; Q340A; Q390A Thermocouples and Q313A,B,C,F Thermopile Generators

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

CompactLogix Power Supplies Specifications

MCR1900 Media Converter 19-Slot Chassis

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Advantium 2 Plus Alarm

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Power Supplies 3. SDN-P DIN Rail Series

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

PSR The compact range Description

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

! WARNING. Before using product, read and understand instructions.

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

T7560A,B,C Digital Wall Module

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

, User s Manual

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Phone: Fax: Web: info@clrwtr.com

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Agilent 4338B Milliohm Meter

SlimSeal SSL Connector. Now Available in 1 Position. Free Hanging Version

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Digital Pressure Measuring Instrument MDR480

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Current Probes. User Manual

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Modular I/O System Analog and Digital Interface Modules

PS6500 Storage Arrays Rack Mount Instructions

Remote Alarm Monitoring System

Electronic overload relay EF19 and EF45

Electronic Control Devices The European Product Catalogue 2007

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Duct Humidity Transmitter

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Digital input modules

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Radiant Temperature Sensor TY7321

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

HERZ-Thermal Actuators

RAY-MAX Integrated Solar Power Strip

INSTALLATION INSTRUCTIONS

UV100A Ultraviolet Air Treatment System

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

IO-RM3 3-Stage Relay Module

Electronic Control Devices The European Product Catalogue 2007

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Bimetallic Overload Relay Specifications

TR21, TR22, TR23, and TR24 Wall Modules

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Contents. Document information

Description. Dimensions. Features. precision works better

Video Camera Installation Guide

Oil and Coolant Circulating Heating System. Model - OCSM

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Softstarters Type PSR

LIEBERT VNSA Installation Sheet

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

ST Series POWER SUPPLIES USER INSTRUCTIONS

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

Three-phase monitoring relay CM-PFE

650W Single Output Power Supply

DALI RC BASIC SO. Control unit Operating instructions

DC400 Dispensing Cutoff System

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Instructions A Amp AC/DC Current Probe

Current Transformers

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown


PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Application/Connection Examples

200W DISCRETE POWER AMPLIFIER K8060

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ADM1TE 5/30A DIN rail single phase two wire energy meter

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

Transcription:

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C DESCRIPTION FEATURES PRODUCT DATA Very low operating trip points LED status indication Integral DIN rail mounting flange Easy wiring, non-polarity sensitive Accepts up to a 350 MCM (17.3 mm) cable Operates up to 200 or 250 continuous amps RoHS and WEEE compliant Limited five year warranty The CSS solid core and the CSP split core current switches have either Normally-Open (N.O.) or Normally-Closed (N.C.) output configurations. All of these sensors will have a solidstate output with an adjustable trip point (setpoint). These current switches are ideal for providing status information on any type of AC current using equipment. The CSS series current switches are an excellent choice for new installations. The CSP series current switches are ideal for retrofit or existing installations since it is not necessary to power down the unit and disconnect any wires during the installation process. The CSS and CSP current switches are accurate, reliable, easy to install and require less servicing than differential pressure switches, flow switches and paddle wheels. These current switches should be used in applications in which a current switch with adjustable trip point is required. A current switch can be used to monitor fan and pump status, motors, compressors and electrical equipment for proper operation. A change in the operating current may indicate motor failure, belt loss/slippage or mechanical failure. Any time one of these events occur the current can significantly increase or decrease, thus tripping the sensor and notifying building management of an alarm condition. The CSS and CSP series current switches can be used to monitor devices with a maximum continuous operating current of up to 200 or 250 Amps depending on the model. These switches will not need to be externally powered since the power for the switch is induced from the conductor being monitored. Another great feature of the CSS and CSP series current switches is that they include both a red and green LED that will indicate the Status of the switch contacts. All of these units come with a unique 1-3/8 in. (35 mm) DIN rail mounting flange and a limited five year warranty. Contents Features...1 Description...1 Specifications...2 Ordering Information...2 Safety...4 Installation...4 Troubleshooting...6 IND.CONT.EQ. 3JHX 63-2651 1

SPECIFICATIONS Sensor Power: Induced from monitored conductor Amperage Rating: 0 to 200 Amps and 0 to 250 Amps (See Table 1) Operating Frequency Range: 40 Hz to 1 khz Isolation Voltage: 2220 Vac Max Sensing Current Voltage: 600 Vac Output Switch Rating: CSS-O; CSP-O: 0.3 Amps @ 200 Vac/Vdc CSS-C; CSP-C: 0.15 Amps @ 300 Vac/Vdc Adjustable Trip Point (Setpoint): See Table 1 Hysteresis (Dead Band): 10% Setpoint, typical Status Indication: Red LED - Above Trip Point Green LED - Below Trip Point Aperture (Hole) Size: 3/4 in. (19 mm), Accepts up to 350 MCM (17.3 mm) cables Dimensions: See Figures 1 and 2 DIN Rail Size: 1-3/8 in. (35 mm) Unit Weight: CSS: 0.21 lb (0.1 kg) CSP: 0.23 lb (0.1 kg) Enclosure Rating/Color: UL94-5VB/Burgundy Operating Temperature Range: 5 to 104 F (-15 to 40 C) Operating RH Range: 0 to 95% RH, non-condensing Agency Approvals: CE, UL Environmental Compliance: RoHS-Directive 2002/95/EC WEEE-Directive 2002/96/EC NOTE: DO NOT use the LED s to indicate whether the sensors have power applied to them. Product Number Core Type Normal Position Table 1. Operating Specifications Adjustable Trip Point Output Switch Rating CSS-O-A300-001 Solid N.O. 1.0-250 Amps 0.30 Amps @ 200 Vac/Vdc CSS-O-A200-001 Solid N.O. 0.5-250 Amps 0.30 Amps @ 200 Vac/Vdc CSS-C-A300-001 Solid N.C. 1.0-250 Amps 0.15 Amps @ 300 Vac/Vdc CSP-O-A300-001 Split N.O. 3.0-200 Amps 0.30 Amps @ 200 Vac/Vdc CSP-O-A200-001 Split N.O. 2.0-200 Amps 0.30 Amps @ 200 Vac/Vdc CSP-C-A300-001 Split N.C. 3.0-250 Amps 0.15 Amps @ 300 Vac/Vdc CSP-C-A200-001 Split N.C. 2.5-250 Amps 0.15 Amps @ 300 Vac/Vdc Max. Current Cont. Max. Current for 6 secs. Max. Current for 1 sec. 200 Amps 400 Amps 800 Amps 200 Amps 400 Amps 800 Amps ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE wholesaler or distributor, refer to the TRADELINE Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory). 2. Honeywell Customer Care 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Toronto, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 63-2651 1 2

TOP VIEW 13/32 (10) TRIP TRIP OFF ADJ TRIP ON TRIP ON = ABOVE TRIP POINT ADJ. RANGE: 0.8-250A OUTPUT: 0.3A @ 200 VDC/VAC 13/64 (5) TYP. LEFT SIDE VIEW 2-27/32 (72) FRONT VIEW RIGHT SIDE VIEW 25/32 (20) 2-17/64 (58) TERMINAL BLOCK 9/64 (4) 1-3/8 (35) 3-3/8 (86) 63/64 (25) M23581A Fig. 1. CSS current sensor dimensions in inches (mm) TOP VIEW 1/2 (13) TRIP TRIP TRIP OFF ON ADJ TRIP ON = Above Trip Point Adj. Range: 2.0-250A Output: 0.3A @ 200 VDC/VAC 7/32 (6) TYP. 2-27/32 (72) LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW TERMINAL BLOCK 3/4 (19) 49/64 (19) 2-45/64 (69) 9/64 (4) 1-3/8 (35) 3-21/64 (85) 1-5/64 (25) M23580A Fig. 2. CSP current sensor dimensions in inches (mm) 3 63-2651 1

R R SOLID CORE AND SPLIT CORE ADJUSTABLE CURRENT STATUS SWITCHES SAFETY WARNING For CSS-O,C ensure that all power sources are disconnected and locked out before installation as severe injury or death may result from electrical shock due to contact with high voltage wires. 3X CAUTION This product is not intended to be used for life or safety applications. CAUTION This product is not intended for use in any hazardous or classified locations. C R U L US INSTALLATION Make sure that all installations are in compliance with all national and local electrical codes. Only qualified individuals that are familiar with codes, standards and proper safety procedures for high voltage installations should attempt installation. The current switches will not require external power, since the power for the current switch is induced from the conductor being monitored. WARNING Never rely on the LEDs to determine whether power is present at the current switch. The red LED will indicate whether the current is above the adjustable trip point. The green LED will indicate whether the current is below the adjustable trip point. IMPORTANT The current switch should be used on insulated conductors only! 3X Fig. 3. Sensor placed on DIN rail C R U L US M25289 The current switch may be mounted in any position using the (2) #8 x 3/4 in. (19 mm) Tek screws and the mounting holes in the base or snapped directly on to the 1-3/8 in. (35 mm) DIN rail (See Figures 3 and 4). Leave a minimum distance of 1 in. (25 mm) between the current switch and any other magnetic devices, such as contactors and transformers. For applications in which the normal operating current is below the 0.8/2.0 Amps trip point (See Fig. 5), the conductor being monitored may be looped through the sensor 6/12 times giving you a total operating current of 6/12 times the original current. Fig. 4. Sensor removed from DIN rail M25290 Example: A small fan operating at 0.2 Amps can be wrapped through the sensor 6 times to give you a total operating current of 1.2 Amps flowing through the CSS-O-A300-001. Another option is to use CSS-O-A200-001. A small fan operating at 0.2 Amps can be wrapped through the sensor 16 times to give you a total operating current of 3.2 Amps flowing through the CSP-O-A300-001. Another option is to use the CSP-O-A200-001. C U L US U L US Fig. 5. Wires through sensors C M25291 63-2651 1 4

R R SOLID CORE AND SPLIT CORE ADJUSTABLE CURRENT STATUS SWITCHES WARNING The secondary of the 5 amps current transformer must be shorted together before the power may be turned on to the monitored device. For applications in which the normal operating current is greater than 250 Amps or for conductor diameters larger that 3/4 in. (19 mm) in diameter, and external 5 Amps Current Transformer (C.T.) must be used as shown in Fig. 6. 600:5 RATIO 5A C.T. WIRE NUT Latch Operation Pressing down on the two (2) side tabs and swinging the cover open opens the split core current switch as shown in Fig. 7. Lifting up the latch with a flat-tip screwdriver as shown in Fig. 8 can also open the unit. Press down firmly on the cover to close the current switch. An audible click will be heard as the tab slides over the tongue on the base. CAUTION Mating surfaces of the magnetic core are exposed when the sensor is open. Silicone grease, present on the cores to prevent rust, can capture grit and dirt if care is not exercised. Operation can be impaired if anything prevents good contact between pole pieces. Visually check the mating parts of the core before closing the current sensor. INSULATED CONDUCTOR EXAMPLE: FOR CURRENTS UP TO 600 AMPS, USE A 600:5 RATIO C.T. AS SHOWN. M25295A Fig. 6. Current transformer C US C U R L US U L M25298 Fig. 7. Opening sensor by hand Wiring Honeywell recommends the use of a 2 conductor 16 to 22 AWG (1.3 to 0.3 mm 2 ) shielded cable or twisted wire, copper wire only, for all current switch output applications. A maximum wire length of less than 98.4 feet (30 meters) should be used between the current switches and the Building Management System or controller. C US U L NOTE: When using a shielded cable, be sure to connect only (1) end of the shield to ground at the controller. Connecting both ends of the shield to the ground may cause a ground loop. M25299 Fig. 8. Opening with a screwdriver When removing the shield from the sensor end, make sure to properly trim the shield so as to prevent any chance of shorting. The current switch output terminals represent a solidstate switch for controlling AC and DC loads and is not polarity sensitive. The recommended torque to be used on the terminal block connections is 5.93 in-lbs. (0.67 Nm). The aperture (hole) size of the current switch is 3/4 in. (19 mm) and will accept a 5 63-2651 1

maximum cable diameter of 350 MCM (17.3 mm). See Fig. 9 for use as a digital input to a building management system and Fig. 10 for use as a pilot relay application. Fig. 9. Digital circuit DIGITAL INPUT #1 BUILDING MANAGEMENT SYSTEM DDC CONTROLLER DI (STATUS) DO (RELAY COIL OR CONTACTOR) M25302 RELAY CONDITIONER Calibration of Adjustable Trip Point The adjustable current switch has an operating range of 0-250 Amps. Do not exceed! The adjustable current switch comes with its fifteen-turn adjustable potentiometer set counterclockwise to its maximum position. The adjustable current switch can monitor Under load, Normal load and Overload conditions, depending on how it's set. The procedure below is for Normal load condition for part numbers CSS-O- A300-001 and CSS-O-A200-001. Normal loads With power on and the adjustable current switch on the proper range, turn the fifteen-turn adjustment potentiometer clockwise until the red LED turns on and stop immediately. The adjustment switch is now tripped. The adjustable current switch Hysteresis (Dead Band) is 10% of the trip point typically. TRANSFORMER 24 VAC COIL 120 VAC LINE 24 VAC COIL M23933 Fig. 10. Analog circuit TROUBLESHOOTING Problem Red LED is on but the current switch didn t activate. Red LED didn t turn on and the current switch didn t activate Sensor doesn t switch at all, regardless of current level. Solution Disconnect the wires from the current switch output. Measure the resistance across the contacts with an Ohmmeter. See Table 2 below for resistance readings for a good unit. Verify that the conductor you are monitoring is above the adjustable trip point. If the sensor is monitoring less than the adjustable trip point, looping the wire may be required. See Fig. 5. Adjustment potentiometer is probably set to its maximum or minimum position. Turn the potentiometer clockwise all the way and verify if the LED switches from red to green. Table 2. Resistance Readings For Good Unit. Product Number Resistance if switch is open Resistance if switch is closed CSS-O-A300-001 Greater than 1 Meg ohms Approximately 2 ohms CSS-O-A200-001 Greater than 1 Meg ohms Approximately 2 ohms CSS-C-A300-001 Greater than 1 Meg ohms Approximately 12 ohms CSP-O-A300-001 Greater than 1 Meg ohms Approximately 2 ohms CSP-O-A200-001 Greater than 1 Meg ohms Approximately 2 ohms CSP-C-A300-001 Greater than 1 Meg ohms Approximately 12 ohms CSP-C-A200-001 Greater than 1 Meg ohms Approximately 12 ohms 63-2651 1 6

7 63-2651 1

Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario M1V 4Z9 customer.honeywell.com U.S. Registered Trademark 2007 Honeywell International Inc. 63-2651 1 C.H. Rev. 06-07