P.O. Box 554-2665 ZN Bleiswijk Brandpuntlaan Zuid 16-2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com



Similar documents
Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009

Challenges for Use of Fixed Fire Suppression Systems in Road Tunnel Fire Protection

FIRE SAFETY FOR OFFICE WORKERS

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

INITIAL ASSESSMENT OF THE IMPACT OF JET FLAME HAZARD FROM HYDROGEN CARS IN ROAD TUNNELS AND THE IMPLICATION ON HYDROGEN CAR DESIGN

Motor Vehicle Fatalities Accepted by the Workers Compensation Board

Fire Risk in Metro Tunnels and Stations

Get Alarmed, Tennessee! Smoke Alarm Program Saves

State of the road tunnel safety technology in Japan

Safety and Environmental Information for External Companies Koehler Oberkirch

JOINT CBA AND SIA GUIDANCE FOR THE STORAGE OF FLAMMABLE LIQUIDS IN SEALED PACKAGES IN SPECIFIED EXTERNAL STORAGE AREAS

Medicine Hat Fire Department. Special Event Requirements. medicinehat.ca/fire. August 2012

MINISTRY OF TRANSPORTATION OF THE REPUBLIC OF LITHUANIA MARINE SHIP ACCIDENT AND INCIDENT INVESTIGATION MANAGER

Previder Datacenters it starts here

Current as of 11/10/08 1 of 1

Emergency Planning Guideline

Andrea Basti* Italian National Institute of Nuclear Physics (INFN) Gran Sasso National Laboratory (LNGS) *Research Grant Holder

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007

Photovoltaic System Technology

P.O. Box ZN Bleiswijk Brandpuntlaan Zuid NZ Bleiswijk The Netherlands

Interested in conducting your own webinar?

Boiler & Pressure Vessel Inspection discrepancies and failures

Death in the line of duty...

CFD STUDY OF TEMPERATURE AND SMOKE DISTRIBUTION IN A RAILWAY TUNNEL WITH NATURAL VENTILATION SYSTEM

Mercedes-Benz Vito. Specifications

TECHNICAL ADVISORY BULLETIN

FIRE RISK ASSESSMENT

The Delivery Hub health, safety and environment Raising the bar 2 Traffic management entry and exit

Guidance Notes FSR 2014

FLA S FIRE SAFETY INITIATIVE

Rail Accident Report. Passenger train collision with a road vehicle at Swainsthorpe level crossing, Norfolk 13 November 2005

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN : 2007

Name Of Occupancy Date. Yes No Describe

Explosion of a gasoline vapour cloud formed in a hydrocarbon loaded effluents storage tank 10 December 1999 Arquata Scrivia Italy

Director, National Institute for Occupational Safety and Health. California Fatality Assessment and Control Evaluation (CA/FACE) Program

Ohio Gas Association 2011 Technical Seminar Lessons Learned From Liability Insurance Claims Paid

Fire testing procedure for concrete tunnel linings

Approval Standard for Plastic Suspended Ceiling Panels

Sensitivity Analysis of Safety Measures for Railway Tunnel Fire Accident

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

MOTOR VEHICLE ACCIDENT CLAIM FORM

Security Tools. Forms. Physical Security Assessment Security Plan Template Traffic Control Plan Template

Decree of the Ministry of the Environment. on fire safety of garages

Document Name: Driving Skills. Purpose: To outline necessary driving skills required to maximize driving safety.

Scientific Issues in Motor Vehicle Cases

DCSS (ACB) Data Center Fire Suppression Procedures

December Newsletter by Vincent Dunn Backdraft and flashover, what is the difference?

Ontario Association of Fire Chiefs Position Paper Residential Fire Sprinklers

Fire Safety Risk Assessment

SAFETY AND ENVIRONMENTAL INFORMATION FOR EXTERNAL COMPANIES. Koehler Kehl

Flammable Liquids Storage

Monthly Warehouse Inspection Checklist

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

The soot and scale problems

Gas Explosion at a Subway Construction Site

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

Home Inspection Report

High-performance steam boiler and hot water boiler plants for industry

NEW SCIENCE FIRE SAFETY ARTICLE INNOVATING FIRE ATTACK TACTICS SUMMER 2013 UL.COM/NEWSCIENCE

MOTOR VEHICLE ACCIDENT CLAIM FORM

ALPERTON COMMUNITY SCHOOL MATHS FACULTY ACHIEVING GRADE A/A* EXAM PRACTICE BY TOPIC

Helsinki, Finland. EPA Award 2011

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

HealthcareBookings.com Security Set Up

chapter 3 basic driving skills

Sauna & Bath House Insurance Presentation/Proposal

Auto v. Mobile Equipment in the CGL

National Transportation Safety Board

Guidelines for designing a wood pellet storage facility

Portable Fire Extinguisher Presentation

A FIREPROOF HOME. Good advice on how to safeguard yourself and your family against fire. Engelsk

Evanston Main Street Station TOD Plan and Study. Appendix A.1: Station Area Existing Conditions

301.7D. Mini Hydraulic Excavator

Fundamentals and practice of CNG safety -

Marquee Building Consents & Fire Safety Guidelines

After the Fire! Returning to Normal

T r a i n i n g T a b l e t

Factors to Consider When Developing an Evacuation Plan

Safety Evidence for Bicycling

Healthcare Help Supporting Health Providers. Module 2 Resources for Fire Warden Refresher Training HH.NET LTD

EMERGENCY ACTION PLAN. for

Electronic & Integrated: The New edvir and Beyond. Rick Ochsendorf - CTP SVP Operations and Product Management

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

Integrated Solar Radiant Systems

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Ionization alarms are best suited for rooms, which contain highly combustible material. These types of material include:

Safety and Environmental Information for External Companies

Fire Damage. To Help Prevent. a Guide

The Impact of IoT for Building Service Contractors

15-Passenger Van Safety Frequently Asked Questions & Recommendations for Safe Operation

Civil Engineering Sector Labour-Management Health and Safety Committee

KINGDOM OF SAUDI ARABIA SAUDI STANDARDS, METROLOGY AND QUALITY ORGANIZATION SASO SAUDI STANDARD. DRAFT No /2013

COMPREHENSIVE PROPERTY INSPECTIONS

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

P.O. Box ZN Bleiswijk Brandpuntlaan Zuid NZ Bleiswijk The Netherlands

Section 14. Forklift Safety Contents 14.1 Operator Safety

FIRE PREVENTION PLAN

Transcription:

P.O. Box 554-2665 ZN Bleiswijk Brandpuntlaan Zuid 16-2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com Investigation into the fire in the Heinenoordtunnel on 21 May 2014 Report no. Sponsor Author(s) Efectis Nederland BV M.P. de Feijter B.Be. Ir. R.J.M. van Mierlo M.Sc. Project number 2014105/111 Date of issue Number of pages 16 All rights reserved. No part of this publication may be reproduced and/or published without the previous written consent of Efectis Nederland. Submitting the report for inspection to parties who have a direct interest is permitted. In case this report was drafted on instructions, the rights and obligations of contracting parties are subject to either the Standard Conditions of Efectis Nederland or the relevant agreement concluded between the contracting parties. 2015 Efectis Nederland BV Page 1 / 16

CONTENTS 1. INTRODUCTION 3 1.1 Purpose of the investigation 3 1.2 Description of the investigation 3 2. INFORMATION 5 2.1 The Heinenoordtunnel 5 2.2 The incident 6 2.3 Other information 9 3. ANALYSES 14 3.1 Heat release rate 14 3.2 Performance of the tunnel lining 15 3.3 Performance of the longitudinal ventilation system 15 3.4 Evacuation 15 4. CONCLUSION 16 This report consists of sixteen pages and may only be used in its entyrety. Page 2 / 16

1. INTRODUCTION On May 21th 2014 a truck crashed into a wall of the Heinenoord tunnel near Barendrecht, The Netherlands and caught fire. The truck driver died in the accident and two people who were involved in the accident got injured. The tunnel was closed for traffic for almost 19 hours. This caused a 100 km long traffic jam in the area of Rotterdam. Heinenoordtunnel Figure 1 The tunnel incident caused a 100 km long traffic jam. (source: www.hulpverleningsforum.nl) Efectis (on its own initiative) responded to the incident on May 21th and started an investigation with the permission of the owner of the tunnel, Rijkswaterstaat and the Rotterdam-Rijnmond Fire Department. Although Rijkswaterstaat allowed Efectis to investigate this fire and this report was reviewed by Rijkswaterstaat, they are not responsible for the contents of this report. 1.1 PURPOSE OF THE INVESTIGATION Efectis investigated the fire to collect data about tunnel fires, to analyse the fire development and to assess the performance of the tunnel lining and the effect of the longitudinal ventilation system. 1.2 DESCRIPTION OF THE INVESTIGATION Efectis investigated the fire on site at the tunnel on May 21th around 17:45hr. Pictures of the damage were taken and information from the Fire department was obtained. Through contacts at Rijkswaterstaat, the Fire department and the contractor Imtech 1, more information was gathered about the incident, the damage and the performance of fire safety measurements. 1 Involved in tunnel repair This report consists of sixteen pages and may only be used in its entyrety. Page 3 / 16

Based on information about the fire load and the duration of the fire, the heat release rate was estimated. The performance of the fire fighting equipment in the tunnel and the efficiency of the fire departments attempt to fight the fire are not a part of this investigation. This report consists of sixteen pages and may only be used in its entyrety. Page 4 / 16

2. INFORMATION 2.1 THE HEINENOORDTUNNEL The Heinenoordtunnel was opened in 1969 as part of the highway A29 near Barendrecht 2. The tunnel is an immersed tunnel under the river Oude Maas that was built in sections of 8,8 meter high, 30,7 meter wide and 115 meter long and gives room to 2x3 traffic lanes. The tunnel has a length of 614 meters and is used by ±85.000 motor vehicles/day 3. Figure 2 Cross section of the tunnel (The lanes and the barrier in picture are not up to date. The tunnel has 3 highway lanes. The concrete barrier is placed near the wall in the middle of the tunnel to provide an escape path) 4 Figure 3 Longitudinal cross section of the tunnel Along the wall in the middle of the tunnel concrete barriers are placed on both sides to create an 1,25 meter wide evacuation path. Every 100-125 meters an escape door is positioned in the middle wall. The tunnel is, amongst others, equipped with a longitudinal ventilation system, a public address system, emergency phones and fire hoses. The lights on the tunnel roof are made of LED s. Illuminated green signs point to the nearest escape door and the fire fighting equipment. 2 http://www.wegenwiki.nl/heinenoordtunnel 3 Statistics from 2010 4 Tunnels in the Netherlands : underground transport connections, Ministry of Infrastructure and Environment This report consists of sixteen pages and may only be used in its entyrety. Page 5 / 16

Figure 4 Fire fighting equipment and escape route signs 2.2 THE INCIDENT At 13:30:51 on May 21th the Fire department was alarmed for a fire in the tunnel. According to an eye witness 5 a tyre of the truck (a Mercedes-Benz Actros 1841 LS 6 ) involved in the accident blew up. The truck zigzagged and drove into the concrete barrier and the tunnel wall on the left side. After hitting the wall the truck turned over and caught fire. In the crash the truck hit another car (Ford Fiësta, 2013). The truck slided while burning over approximately 100 meters through the tunnel and stopped blocking 2,5 lanes of the tunnel. The car that was hit by the truck turned upside down right behind the truck. The driver and passenger of the car got out on their own with severe (burn) injuries. The truck driver died in the accident. Figure 5 gives an impression of the situation short after the accident. Figure 6 gives an impression of the amount of smoke produced by the fire. The truck stopped near the middle of the tunnel. Traffic in front of the truck was able to exit the tunnel. The traffic behind the truck came to a halt. Through the PA system people were instructed to leave their car and exit the tunnel. The eye witness is a public bus driver who entered the tunnel right behind the truck. He describes a calm evacuation. According to the bus driver people were following instructions. According to the camera images from the tunnel, the fire lasted for about 31 minutes. The cabin of the truck, the container floor, the truck tyres, the (diesel) fuel and the front of the car were consumed by the fire. The cargo load of the truck in the 40 container consisted of drums filled with salt, stacked on wooden pallets. Most of the wooden pallets and the drums were consumed by the fire. The salt was still in the container. 5 http://youtu.be/5wrkdvzaakc (The eye witness is a public bus driver who entered the tunnel right behind the truck.) 6 Fire department Rotterdam-Rijnmond / Rijksdienst voor het wegverkeer This report consists of sixteen pages and may only be used in its entyrety. Page 6 / 16

Figure 5 Picture of the fire in the tunnel. (source: Twitter account Richard Hoogeveen, @RichardMaasdijk) Figure 6 Smoke at the tunnel south exit (source: www.hulpverleningsforum.nl) This report consists of sixteen pages and may only be used in its entyrety. Page 7 / 16

Figure 7 gives an impression of the situation in the tunnel after the accident. Figure 7 Schematic situation in the tunnel after the accident Figure 8 Remains of the truck cargo load. This report consists of sixteen pages and may only be used in its entyrety. Page 8 / 16

2.3 OTHER INFORMATION 2.3.1 Fire load The fire load consisted of the truck and trailer and half the car. The following information was obtained about the truck and the trailer. Truck: Brand: Mercedes-Benz Type: Actros 1841 LS Fuel: diesel (430 litre) Empty weight: 7150 kg Tare weight: 7250 kg Gross weight: 18600 kg cylinder capacity: 11946 cm3 Power: 300 kw (408 hp) Parts of the truck like the dashboard are made of plastics. Based on information from Daimler-Mercedes a maximum of 8% of the truck consists of plastics and other material than metal, tyres and fuel. The tyres are mainly made of rubber with a mass of about 70 kg (estimated). There were 6 tyres on the truck. Trailer and container: 3 axles = 6 tyres Wooden floor (trailer floors are constructed out of bamboo or laminated wood). For this investigation the floor is assumed to be constructed out of laminated wood with a thickness of 30mm. Most floors are constructed of hardwood 7. For this investigation a density of 700 kg/m 3 is assumed) Estimation of the cargo load: 20 Euro-pallets 360 cardboard or fibre drums filled with salt (The empty drums are estimated to weigh about 3 kg each) Car: For the car an average amount of energy based on earlier research 8 is used. Object Mass (kg) Total Energy (MJ) 9 Plastics on the truck 572 17.732 Tyres on the truck 420 11.760 Diesel fuel 360 (worst case) 15.120 Trailer floor 590 9.912 Trailer tyres 420 11.760 Trailer load (pallets) 480 8.380 Trailer load (cardboard or cellulose fibre) 1.080 17.604 ½ Car (Ford Fiësta) n/a 2.625 Total 94.893 2.3.2 Tunnel protection and damage to the tunnel The tunnel roof and the upper parts of the walls are protected with a 27,5 mm thick PROMATECT-H lining. The lining is mounted in 1990. The longitudinal tunnel ventilation system was on during the fire. The picture in figure 5 shows that the part of the tunnel behind the truck is clear of smoke, while flames are visible in the entire tunnel cross section. Smoke is pushed to the tunnel exit on the south side (figure 6). The damage patterns on the 7 Information about the construction of containers was obtained from CETEM Containers (www.cetem.com) 8 CTICM, ARBED Recherches, TNO, July 1998, Demonstration of real fire tests in car parks and high buildings. Daniel Joyeux, August 1997, Natural fires in closed car parks. 9 Deel 2: Toepassingsinstructie BVB 2007, bijlage A, Save, April 2007. This report consists of sixteen pages and may only be used in its entyrety. Page 9 / 16

wall next to the truck cabin also indicate the influence of longitudinal ventilation. Figure 9 gives an impression of the damage pattern on the tunnel wall. The damage extends in the direction of the airflow. Figure 9 Damage pattern on the tunnel wall The red lines in figure 9 give an indication of the shape of the damage. In the direct vicinity of the truck cabin the concrete wall showed damage due to spalling. A maximum spalling depth of 2,5 cm was measured (figure 10). The concrete showed a buff discolouration, which indicates temperatures 10 reached more than 1.000 C. The discolouration of the concrete was only visible around the cabin and can be explained by direct flame impingement. 10 Principles of Fire Investigation, Institution of Fire Engineers, Roy A. Cooke, Rodger H. Ide, 2006 This report consists of sixteen pages and may only be used in its entyrety. Page 10 / 16

Figure 10 Spalling of concrete Figure 11 The tunnel lining directly over the cabin shows a clean burn. Directly over the cabin and in front of the cabin a clean burn pattern was visible on the tunnel lining. The lining has a black appearance along the length of the tunnel (this is probably due to sooth from traffic). Due to the fire the black layer of sooth directly above the cabin of the truck was burned off. Figure 11 gives an impression of the lining on the tunnel wall and roof directly over the cabin. In this picture you can see the remains of a speaker of the PA system. The speaker was consumed by the fire. This report consists of sixteen pages and may only be used in its entyrety. Page 11 / 16

An indication of the thickness of the smoke layer in the tunnel during the fire can be found in figure 9. The black rectangle on the left side of the picture is an escape route sign. This sign is totally covered in sooth, which indicates that the smoke layer was at least as low as 1,2 meters above the road surface. In figure 11 a sign above a fire extinguisher placed on the tunnel lining is not covered in sooth (on the bottom right side of the picture). This gives an indication that there was no or just a thin smoke layer on the up wind side of the truck. In figure 12 the damage to the barrier and the left tunnel wall due to the crash is visible. Figure 12 Damage to the barrier and the left tunnel wall due to the crash On the tunnel roof a lighting system was installed consisting of LED lights. Most part of this lighting system was still working after the fire. Some parts were melted or soothed. In figures 13 and 14 the damage to the lighting system is visible in an overview of the accident area in the tunnel. Figure 13 Overview from behind the truck. Large parts of the lighting system are on after the fire This report consists of sixteen pages and may only be used in its entyrety. Page 12 / 16

Figure 14 Overview from the front side of the truck The contractor who repaired the tunnel after the fire stated that the electric wiring behind the PROMATECT-H tunnel lining showed no damage. This report consists of sixteen pages and may only be used in its entyrety. Page 13 / 16

3. ANALYSES 3.1 HEAT RELEASE RATE Based on the duration of the fire and the estimated amount of materials consumed by the fire it is possible to calculate the heat release rate during the fire. From the analysis in paragraph 2.3.1 a total amount of energy of 94.893 MJ was present in the tunnel. Most part of this fuel was consumed by the fire. Part of the pallets in the container were still visible. The amount of fuel burned is estimated to be 90%. The heat release rate is calculated based on a total amount of energy 85.404 MJ. Efectis was allowed to watch the video footage from the CCTV system in the tunnel. In this video it is visible that the fire grew quickly (within one minute) directly after the crash. This rapid fire development can only be explained by a ruptured fuel tank. The hypothesis of a ruptured fuel tank is confirmed by the fact that just after the crash a reflecting surface (pool of fuel) is visible between the truck and the car behind the truck (based on video footage). The fire department was alarmed at 13:30:34 and the first attempt to extinguish the fire was made around 13:46. It is estimated that between the crash and the alarm 2 minutes passed by. The previous analysis leads to a fire curve that grows to a maximum in 1 minute and maintains about the same rate of heat release (HRR) during 18 minutes. The fire lasted for a total of 31 minutes. Within the remaining 12 minutes the fire decayed and was extinguished by the fire department. The peak output of the fire is estimated to be between 50 and 65 MW. In figure 15 the estimated fire curve is given. 70 Estimated Heat Release Rate Heinenoordtunnel HRR (MW) 60 50 40 30 20 10 HRR 0-10 Figure 15 0 5 10 15 20 25 30 Estimated fire curve Time (min.) This report consists of sixteen pages and may only be used in its entyrety. Page 14 / 16

3.2 PERFORMANCE OF THE TUNNEL LINING From within the tunnel the PROMATECT-H lining showed no visible damage. After editing the photo used in figure 11 it became visible that some parts of the tunnel lining were cracked. It is not possible to determine whether these cracks are a result of the fire or were present in the lining before the fire occurred. 3.3 PERFORMANCE OF THE LONGITUDINAL VENTILATION SYSTEM On the video footage no back layering of smoke is visible. The smoke stain on the tunnel ceiling and walls indicate that the ventilation system in the incident tube was functioning properly. The fire department communication was hindered by the sound level of the ventilation system. It is safe to state that the ventilation system in the incident tube was functioning the way it should during the fire. Almost no heat damage occurred beyond 40m from the fire (downstream). Up to 60 m beyond the burning truck there was more damage and pollution to the installations in the tunnel. Although all systems remained functional, the damage and smoke pollution in and on the installation makes a replacement in due time over a total length of 200 m necessary. The tunnel cross section behind the burning truck was filled with smoke which indicates a laminar flow through the tunnel cross section. 3.4 EVACUATION The evacuation is visible on the video footage. On youtube an interview with a bus driver, who stopped right behind the accident, can be found (reference in paragraph 2.2). Traffic stopped directly behind the truck and the car involved in the crash. At first some cars backed up and one van turned around. The professional drivers (two public bus drivers) initiated an evacuation and through the PA system people were told to leave their car and exit the tunnel. The evacuation went calm and in order. The two victims in the car managed to escape the burning vehicle. When the fire department arrived they walked towards the fire truck and were treated for burn injuries by the first arriving fire fighters. This report consists of sixteen pages and may only be used in its entyrety. Page 15 / 16

4. CONCLUSION The PROMATECT-H tunnel lining protected the tunnel during the fire. The tunnel lining was still in place and performed as expected. The estimated heat release rate of the fire (max. 58 MW) and the duration of the fire is below the design criteria of the tunnel. The longitudinal ventilation system mixed smoke and cool air which led to relative low temperatures just behind the burning truck and prevented heat damage to the tunnel lining and the functionality of the tunnel installations. Further downstream the installations were more damaged and polluted which makes replacement in due time necessary. The ventilation system prevented smoke from flowing upstream and made a safe evacuation and safe fire fighter operations possible. The P.A. system made a smooth evacuation possible. The incident made clear that the presence of professional drivers helps in an emergency situation to speed up the evacuation. M.P. de Feijter B.Be, IAAI-CFI Project leader fire investigation R.J.M. van Mierlo M.Sc. Senior project leader fire engineering This report consists of sixteen pages and may only be used in its entyrety. Page 16 / 16