Determination of N-cyclohexyl-diazeniumdioxide (HDO) containing compounds in treated wood using GC-MS



Similar documents
Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

AppNote 6/2003. Analysis of Flavors using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Indoor Air Comfort Test Report

Expectations for GC-MS Lab

Application Note # MS-14 Fast On-site Identification of Drugs with the mobile GC/MS system E²M

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

Pesticide Analysis by Mass Spectrometry

Analyzing Small Molecules by EI and GC-MS. July 2014

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Setting up a Quantitative Analysis MS ChemStation

Background Information

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

Analysis of Liquid Samples on the Agilent GC-MS

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

How To Analyze Pesticide Levels In Lemon Oil

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Application of TargetView software within the food industry - the identi cation of pyrazine compounds in potato crisps

All the prepared formulations were subjected for following. evaluation parameters and obtained results were showed in Tables 6.3 &

How To Test For Contamination In Large Volume Water

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

Fractional Distillation and Gas Chromatography

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

AMD Analysis & Technology AG

ALLERGENS IN PERFUMES: GAS CHROMATOGRAPHY^ MASS SPECTROMETRY

IUCLID 5 COMPOSITION AND ANALYSIS GUIDANCE DOCUMENT: IRON ORES, AGGLOMERATES [EINECS NUMBER , CAS NUMBER ] IRON ORE PELLETS

Analysis of Phthalate Esters in Children's Toys Using GC-MS

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Aromatic plants: from extraction to analysis

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

MASS SPECTROMETRIC IDENTIFICATION OF SOME SULPHUR CONTAINING PHENALKYLAMINE DESIGNER DRUGS *

How To Use Gc-Ms

6. ANALYTICAL METHODS

Multi-Shot Pyrolyzer EGA/PY-3030D. Flexible Versatile Reproducible

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

Quantitation of Drugs in Dried Bloodstains. Thomas Meyer Anna Gomenyuk Nadiah Lester

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Chemical analysis service, Turner s Green Technology Group

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Paper Chromatography: Separation and Identification of Five Metal Cations

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

WHITE PAPER CONTINUOUS AIR MONITORING USING GRIFFIN 460 MOBILE GC/MS. HEADINGS: ALL CAPS, 12 PT TREBUCHET FONT, ICx BLUE

Integrated Data Mining Strategy for Effective Metabolomic Data Analysis

SCREENING FOR THE PRESENCE OF PARA-METHYLTHIOAMPHETAMINE IN URINE BY SOME COMMERCIAL IMMUNOASSAYS AND CONFIRMATION BY GC/MS

Supplementary Materials and Methods (Metabolomics analysis)

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

NITRIC OXIDE and NITROGEN DIOXIDE 6014

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Performance and advantages of qnmr measurements

Bridging the analytical gap

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

TECHNICAL BULLETIN. ProteoMass Peptide & Protein MALDI-MS Calibration Kit. Catalog Number MSCAL1 Store at Room Temperature

Technical Procedure for the Solid Phase Extraction of Acidic, Neutral and Basic Drugs for GC-MS Analysis

DMA-1 Direct Mercury Analyzer

ProteinChip Energy Absorbing Molecules (EAM)

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Fast Continuous Online Analysis of VOCs in Ambient Air using Agilent 5975T LTM GC/MSD and Markes TD

Utilization of Rapid LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using an Exactive Plus Benchtop Orbitrap Platform

How To Build An Amd Quas 3 Ar Mass Spectrometer

Weight Loss Determined from Mass Spectrometry Trend Data in a Thermogravimetric/Mass Spectrometer System

The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies

Fipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup

GUIDELINES FOR THE VALIDATION OF ANALYTICAL METHODS FOR ACTIVE CONSTITUENT, AGRICULTURAL AND VETERINARY CHEMICAL PRODUCTS.

The Stability of Natural History Specimens In Fluid-preserved Collections

Alignment and Preprocessing for Data Analysis

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

A.17. OXIDIZING PROPERTIES (SOLIDS)

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites

MILESTONE H E L P I N G C H E M I S T S

TABLE OF CONTENTS CHAPTER TITLE PAGE DECLARATION ACKNOWLEDGEMENT ABSTRACT LIST OF TABLES LIST OF FIGURES LIST OF SYMBOLS LIST OF APPENDICES

GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs

Application of Structure-Based LC/MS Database Management for Forensic Analysis

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

L. Yu et al. Correspondence to: Q. Zhang

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Transcription:

Application Note No. 051 Determination of N-cyclohexyl-diazeniumdioxide (HDO) containing compounds in treated wood using GC-MS by P Jüngel ¹), J Wittenzellner ²) and E Melcher ¹) ¹) Federal Research Centre for Forestry and Forest Products (BFH), Leuschnerstr. 91 D 21031 Hamburg, Germany ²) Dr. Wolman GmbH, PSF 1160, D 76545 Sinzheim, Germany ABSTRACT Beside the biological effectiveness the approval of a chemical wood preservative requires also techniques for the analytical determination of active ingredients in different matrices. Fulfilling of the last requirement is particularly difficult in the case of impregnated timber treated with wood preservatives containing organic compounds. This paper describes a procedure for the determination of the organic ingredient N-cyclohexyldiazeniumdioxide (HDO) in solid phases using gas chromatography coupled with mass spectrometry (GC-MS) in connection with a previous thermal desorption step. For this powdered samples are placed in a glass tube. Then the tube is reinserted into the thermal desorption unit which is placed in the GC-oven and directly connected with the capillary column. Afterwards the sample was quickly heated up to 200 C. The resulting gas mixture is pushed onto the column and the separation of the gas components took place. The single components could be identified by means of the retention time and the mass spectrum. A quantitative determination seems to be possible by means of the intensity of the signals. The suitability and reproducibility of this method of the determination of HDO were tested successfully by analysing a number of impregnated wood specimens treated with different formulations containing HDO. Key words: GC-MS, thermal desorption, analysis, N-cyclohexyl-diazeniumdioxide (HDO), wood preservative, impregnated wood 1 INTRODUCTION The conversion of the Biocidal Products Directive 98/8/EC (BPD) requires also an environmental risk assessment for impregnated timber. The analytical determination of wood preservative components in different matrices is an important tool for any such assessment. At the moment, however, there are deficits in the availability of suitable methods of analysis for the detection of organic wood preservative components in solids, for example wood. The gas chromatography coupled with different detection systems represents a widespread method, which was used successfully for the determination of organic components in treated wood (FERLAZZO 1999). The execution of this procedure, however, requires often an extensive sample preparation, like an extraction of impregnated wood. A direct method represents the pyrolisis-gc-ms (HORN and MARUTZKI 1994). This technique is particularly remarkable: despite the high temperatures (700 degree) thermally unstable substances can be analysed. A disadvantage is that beside the substances of interest also numerous pyrolysis products of the wood should be pushed onto the GC-column. As a result of this the ratio of the signal to the background can be worse. It is to be assumed that the content of pyrolisis products of the wood should be decrease when this investigation is carried out at lower temperatures (thermodesorption). Therefore on the basis of thermodesorption - GC-MS (KARPE

et al. 1995), the possibility of a determination of the wood preservative component HDO have been investigated. 2 MATERIAL AND METHODS 2.1 MATERIAL The investigations were carried out using water-soluble K-HDO and treated Pinus-sapwood. The wood specimens were impregnated with K-HDO or Cu-HDO based WOLMANIT CX-products. 2.2 DESCRIPTION OF THE TECHNICAL EQUIPMENT Figure 1 shows the technical equipment used Figure 1: technical device consisting of 1a: automatic sampler (ATAS); 1b: sample rack with vials; 2a: control element of the thermodesorption-unit; 2b: thermodesorber; 3: GC (Finnigan); 4: MS (Finnigan); 5: Computer including GC-MS software 2.3 SAMPLE PREPARATION OF TIMBER The wood specimens were splitted and a so called "Retschmill" was used to produce wood chips. The size of chips was limited by means of a sieve attachment with a mesh size of 3 mm. During this procedure a homogenisation of the sample material took place. Up to 20 mg of the powdered samples are placed in a vial. Then the tube is reinserted into the thermal desorption unit which is placed in the GC-oven and directly connected with the capillary column. Afterwards the sample was during few seconds heated up to 200 C. A part of the resulting gas mixture is pressed onto the column of the GC and the separation and fragmentation of the gas components took place. The parameters for investigation are shown in table 1.

3 RESULTS Figure 2 shows the chromatogram obtained for K-HDO dissolved in water. The signal in the chromatogram after the retention time of 03:48 minutes should be HDO because this solution contained only HDO as organic component. An indication for this theory is the mass spectrum added. It is to emphasise, that the fragments of HDO can be derived according usual disintegration rules (HÜBSCHMANN 1996). Identical results were received after investigations of solutions containing Cu-HDO as well as crystals of K-HDO and Cu-HDO. General a lot of signals were obtained in the case of investigations of wood. These signals result from the desorption of substances contained in the wood. Very small signals could be detected for untreated wood around the retention time of HDO. The corresponding mass spectra were not identically to the mass spectrum of HDO. The chromatogram of K-HDO treated sample is shown in figure 3. It is to be seen, that a clear signal exist at the retention time of 03:47 minutes. The evaluation of the corresponding mass spectrum allows the conclusion that this substance is definitely HDO (see the mass spectrum in figure 2). Identical results were also obtained for wood treated with Wolmanit CX-formulations (see figures 4 and 5). A comparison of both chromatograms shows that an increase of the concentration for HDO in wood leads to an increase of the intensity of the signal for HDO. From these observations can be deduced, that a quantitative detection of HDO should be possible. Furthermore can be assumed that the detection limit of HDO in treated timber is approx. 50 ppm HDO. 4 OUTLOOK Based on the previous results principally the investigations have to be concentrated on the following topics: Use of this procedure for different wood species Quantitative determination of HDO (calibration) Testing the suitability of this method for determination of HDO in different matrices Adaptation of this procedure on other organic active ingredients 5 REFERENCES FERLAZZO, D. E. 1999. Analysis of tebuconazole in wood treated with Tanalith E. Int. Res. Group on Wood Pre., Doc. No. IRG/WP/99-20158, 21 pp. HORN, W.; MARUTZKY, R. 1994. A rapid pyrolytical method for the determination of wood preservatives in treated wood. Fresenius J Anal Chem 348, 832-835. HÜBSCHMANN, H.-J. 1996. Handbuch der GC/MS Grundlagen und Anwendung. Weinheim, VCH Verlagsgesellschaft mbh, 586 pp. KARPE, P.; KIRCHNER, S.; ROUXEL, P. 1995. Thermal desorption-gas chromatography-mass spectrometry-flame ionization detection-sniffer multi-coupling: A device for the determination of odorous volatile organic compounds in air. Journal of Chromatography A 708, 105-114.

Chromatogram Plot Comment: 2µl K-HDO solution containing 500 ppm HDO on glass wool Scan No: 90 Retention Time: 03:48 RIC: 6409442 Mass Range: 36-149 Plotted: 1 to 112 Range: 1 to 112 100% = 6409442 Figure 2: Chromatogram and mass spectrum of K-HDO dissolved in water

Chromatogram Plot Comment: EN 113 specimen treated with K-HDO (initial retention approx. 6kg/m ³ ) Scan No: 329 Retention Time: 03:47 RIC: 9823420 Mass Range: 35 150 Plotted: 100 to 500 Range: 1 to 508 100%= 9823420 Figure 3: Chromatogram and mass spectrum of impregnated timber treated with K-HDO

Chromatogram Plot Comment: Timber treated with Cu-HDO; containing 93 ppm HDO; sample mass 15.8 mg Scan No: 332 Retention Time: 03:49 RIC: 4761835 Mass Range: 35 150 Plotted: 50 to 500 Range: 1 to 609 100%= 10827050 Figure 4: Chromatogram and mass spectrum of wood treated with a Wolmanit CX-formulation and a initial retention of 93 ppm HDO in the specimen

Chromatogram Plot Comment: Timber treated with Cu-HDO; containing 233ppm HDO; sample mass 15.1 mg Scan No: 249 Retention Time: 03:47 RIC: 14350520 Mass Range: 35 150 50 Plotted: to 500 1 to Range: 632 100%= 27857290. Figure 5: Chromatogram and mass spectrum of wood treated with a Wolmanit CX-formulation and a initial retention of 233 ppm HDO in the specimen