Determination of PCDD/Fs in Environmental Samples using Accelerated Solvent Extraction (ASE) and GC-MS/MS



Similar documents
TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Application Note. Abstract. Authors. Food Safety

MICROORGANIC POLLUTANTS: ACTION NEEDED TO SIMPLIFY THEIR ANALYSIS

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Thermo Scientific ClinQuan MD Software For In Vitro Diagnostic Use. Confidence in Results With Data Integrity

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Thermo Scientific TSQ Quantum XLS Triple Quadrupole GC-MS/MS

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Thermo Scientific Compound Discoverer Software. A New Generation. of integrated solutions for small molecule structure ID

Thermo Scientific SIEVE Software for Differential Expression Analysis

Gas Chromatography Liner Selection Guide

Mass and Resolution Calibration for New Triple-Stage Quadrupole Mass Spectrometers. Rob Grothe Thermo Fisher Scientific, San Jose, CA

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

Thermo Scientific ConFlo IV Universal Interface

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping

GCxGC COUPLED TO FAST SCANNING QUADRUPOLE MS FOR TRACE ANALYSIS OF POPs

Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System

Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)

Thermo Scientific LIFECYCLE Asset & Service Management for Healthcare

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

LC-MS/MS, the new reference method for mycotoxin analysis

European Union Reference Laboratory for Dioxins and PCBs in Feed and Food

MIDLAND AREA SOIL SAMPLING MIDLAND, MICHIGAN

METHOD SUMMARY & DATA QUALITY OBJECTIVES

Thermo Scientific ExactFinder Software

AutoSpec Premier. Are you? Analyzing dioxins and related compounds? Required to satisfy regulatory requirements?

Pesticide Analysis by Mass Spectrometry

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Utilization of Rapid LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using an Exactive Plus Benchtop Orbitrap Platform

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

How To Test For Contamination In Large Volume Water

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

AMD Analysis & Technology AG

A Complete Solution for Method Linearity in HPLC and UHPLC

RAPID MARKER IDENTIFICATION AND CHARACTERISATION OF ESSENTIAL OILS USING A CHEMOMETRIC APROACH

HORIZONTAL concerning the layout, editorial and technical content, this document needs revising. In order to harmonize all documents within

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

WATERS QUANTITATIVE ANALYSIS solutions

LIFECYCLE. Thermo Scientific. Enterprise Solutions

FT-NIR for Online Analysis in Polyol Production

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Opiates in Urine by SAMHSA GC/MS

Third Party Instrument Control with Chromeleon Chromatography Data System (CDS) Software

[ Care and Use Manual ]

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Analyzing Small Molecules by EI and GC-MS. July 2014

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

What is Eluent Generation?

Chemical Profiling and Differential Analysis of Whiskies Using Orbitrap GC-MS

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

A Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015

How To Control A Record System

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Background Information

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Pesticide residue analysis: New Trends. Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific

FOOD FOR THOUGHT Topical Insights from our Subject Matter Experts UNDERSTANDING WHAT IS NEEDED TO PRODUCE QUALITY DATA

Samples RMN Analytical Report ( ) GC/FID Analysis (RM01) Nicotine Purity

Thermo Scientific Vanquish UHPLC System. Revolutionize Your. UHPLC Experience

Oilfield Services Measurement Solutions

Thermo Scientific Qtegra Intelligent Scientific Data Solution Software. Delivering quality. Driving productivity

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Benzo[a]pyrene Method Development

Application of TargetView software within the food industry - the identi cation of pyrazine compounds in potato crisps

Which analytical tools/instruments/techniques are used for POPs. A general walk through the analysis

New drugs of abuse? A case study on Phenazepam & Methoxetamine

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

Determination of Calcium and Magnesium in Brine

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

aurora M90 Innovation with Integrity A new era in ICP-MS ICP-MS

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

Reference Materials for Environmental Performance Testing Dr Steve Wood Head of Regulatory and Legislative Services. ISPRA 25 June 2009

Accepted 26 May 2006 Available online 17 January 2007

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

Application Note # MS-14 Fast On-site Identification of Drugs with the mobile GC/MS system E²M

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Transcription:

Determination of PCDD/Fs in Environmental Samples using Accelerated Solvent Extraction (ASE) and Paul Silcock, 1 David Gardner, 2 John Fardon, 2 Steve Moss 2 and Inge de Dobbeleer 1 1 Thermo Scientific POPs Centre of Excellence, Bremen, Germany 2 National Laboratory Service - Environment Agency, Leeds, United Kingdom Application Note 36 Key Words Dioxins, furans, PCDD, PCDF, environmental, fly ash, sediments, complex matrix, accelerated solvent extraction, isotope dilution, pressurized solvent extraction Introduction The measurement of PCDD/Fs in the environment is a widespread activity carried out by many regulatory agencies globally. The chronic toxicity of these compounds to humans and wildlife at extremely low concentrations requires that the techniques used in determination must be both sensitive and selective enough to allow high confidence results. This is especially true when measuring background levels in environmental matrices, such as soil and sediment or byproducts from waste incineration processes. Traditionally high resolution magnetic sector GC-MS () instrumentation has delivered the required analytical performance and has become the gold standard technique. In recent years, there has been more interest in GC triple-quadrupole instrumentation for this purpose, especially in the area of food safety control. 1,2 For this area and environmental analysis, it is necessary to deliver data that performs in the range of HRMS systems, which requires especially sensitive triple-quadrupole systems. It is also necessary to incorporate data-processing software specifically designed to handle the complex calculations associated with dioxins analysis. This application note describes the use of the Thermo Scientific TSQ Quantum XLS Ultra as applied to the analysis of PCDDs/PCDFs in sediments, soils, bottom, and fly ash (as incineration by-products) at the levels of interest and the level of agreement with gold standard analysis using. During this study, instrumental LOQs using were calculated in the low fg/µl concentration ranges. This, along with further analytical performance, is discussed alongside ; especially the degree of agreement between the techniques in some routine sample batches. Materials and Methods Extraction and Cleanup The standard spiking protocols, extraction, and cleanup process for all sediment and soil samples were performed using an ISO1725 accredited in-house variation of EPA 16B3. For incinerator ash samples, an in-house method based upon EN 19484 was applied. For both of these methods, accelerated solvent extraction was used as the preferred technique for extraction after initial sample processing. This is routinely used in the laboratory to reduce solvent consumption, allow for automation, and to generate efficient sample extractions within the performance limits required.

2 Accelerated Solvent Extraction Methods ASE cells were loaded with a base layer of copper filings then a layer of rinsed Ottawa sand (previously ashed at 45 C) after which 5 g of sample for soils/sediments (1 g for fly ash). Finally, another layer of sand was added to fill the cell and then extracted (Figure 1). GC-MS Measurement & Data Processing The measurements were performed using a Thermo Scientific TRACE GC Ultra coupled to a TSQ Quantum XLS Ultra system with quantitation performed using Thermo Scientific TargetQuan 3 software. Tables 1 and 2 show the instrument parameters used. Table 1. GC and injector conditions. Split/Splitless Injector (PCDD/Fs) Injection Temperature 26 C Toluene flow during extraction Extraction Solvent: Extraction Pressure: Oven Temperature: Heating Time: Static Time: Flush: Purge: Toluene 15 psi 175 C 8 minutes 5 minutes 6 % Cell volume N 2 24 Seconds Ottawa sand Soil/sediment/fly ash Ottawa sand Copper filings Figure 1. Cell schematic and method conditions for the extraction of PCDD/Fs from soil, sediment, and fly ash samples. Liner Injected Volume Splitless Time Surge Pressure GC Column GC Column Flow Table 2. Mass spectrometer parameters. Splitless straight liner (Siltek) 3 8 15 mm (PN 453T2121) 2 µl (toluene) 1.5 min 22 psi (1 min) GC Program Initial Temperature 12 C Rate 1 TraceGOLD TG-5SilMS 6m.25mm.25um (PN 2696-154) 1.2 ml/min constant 18 C/min to 2 C (1 min) Rate 2 4 C/min to 29 C Final Temperature 29 C for 15 min Parameters Source Temperature 25 C Ionization Electron Energy EI 4 ev Emission Current 5 µa Q2 Gas Pressure (Argon) Collision Energy Q1 Peak Width FWHM Q3 Peak Width FWHM 1.5 mtorr 22 ev.7 Da.7 Da

The collision cell (Q2) gas pressure and collision energy were optimized for PCDD/F measurement at 22 ev. The monitored selected reaction monitoring (SRM) transitions as well as the MS conditions are given below in Table 3. 3 Table 3. Target congener groups SRM transitions. Compound Name Abrev. Formula Nominal Mass Exact Mass Presursor Ion m/z Product Ion m/z Collision Energy [ev] Tetrachloro-dibenzodioxin TCDD H 4 Cl 4 32 319.8965 319.9 256.93 22 321.89 258.93 22 Pentachloro-dibenzodioxin PeCDD Cl 5 354 353.8576 355.85 292.89 22 357.85 294.89 22 Hexachloro-dibenzodioxin HeCDD Cl 6 388 387.8186 387.82 324.86 22 389.82 326.85 22 Heptachloro-dibenzodioxin HpCDD Cl 7 422 421.7796 423.78 36.81 22 425.77 362.81 22 Octachloro-dibenzodioxin OCDD Cl 8 456 455.747 457.74 394.77 22 459.74 396.77 22 Tetrachloro-[ ]dibenzodioxin TCDD H 4 Cl 4 332 331.9368 331.94 267.97 22 333.93 269.97 22 Pentachloro-[ ]dibenzodioxin PeCDD Cl 5 366 365.8978 367.9 33.93 22 369.89 35.89 22 Hexachloro-[ ]dibenzodioxin HeCDD C l6 4 399.8589 399.86 335.89 22 41.86 337.89 22 Heptachloro-[ ]dibenzodioxin HpCDD Cl 7 434 433.8199 435.82 371.85 22 437.81 373.85 22 Octachloro-[ ]dibenzodioxin OCDD Cl 8 468 467.789 469.78 45.81 22 471.78 47.81 22 Tetrachloro-dibenzofuran TCDF H 4 OCl 4 34 33.916 33.9 24.94 22 35.9 242.94 22 Pentachloro-dibenzofuran PeCDF OCl 5 338 337.8627 339.86 276.9 22 341.86 278.89 22 Hexachloro-dibenzofuran HeCDF OCl 6 372 371.8237 371.82 38.86 22 373.82 31.86 22 Heptachloro-dibenzofuran HpCDF OCl 7 46 45.7847 47.78 344.82 22 49.78 346.82 22 Octachloro-dibenzofuran OCDF OCl 8 44 439.7457 441.76 378.8 22 443.76 38.79 22 Tetrachloro-[ ]dibenzofuran TCDF H 4 OCl 4 316 315.9419 315.94 251.97 22 317.94 253.97 22 Pentachloro-[ ]dibenzofuran PeCDF OCl 5 35 349.929 351.9 287.93 22 353.9 289.93 22 Hexachloro-[ ]dibenzofuran HeCDF OCl 6 384 383.8639 383.86 319.9 22 385.86 321.89 22 Heptachloro-[ ]dibenzofuran HpCDF OCl 7 418 417.825 419.82 355.86 22 421.82 357.85 22 Octachloro-[ ]dibenzofuran OCDF OCl 8 452 451.786 453.78 389.82 22 455.78 391.81 22

4 Results and Discussion Sensitivity for PCDD/F Analysis The prerequisites for a technique to be applicable to low level PCDD/F determinations is sensitivity and selectivity. The concentration levels where these substances are required to be measured often exceed the performance capability of bench-top GC-MS systems. In order to test the sensitivity of the TSQ Quantum XLS Ultra for this application, a serial dilution of commonly used EPA 16B CS1 standard was performed, and increasingly low levels were injected onto the system. The limit of detection (LOD) was then calculated using statistical methods. Figure 2 shows the lowest level CS1 dilution (x1 vial concentrations given in Table 4) used for this study. Quantitative SRM ions are clearly detected along with the confirmatory SRM ions for all PCDD/Fs tested within the QC ion ratio criteria. Precision studies at this level enabled an LOD to be calculated for the methodology. Table 4 gives the precision data obtained and calculated LOD at 99 % confidence limits. The LOD obtained from the TSQ Quantum XLS Ultra was found at a level that is highly applicable for environmental dioxins analysis in a range of sample types. Table 4. Instrumental LOD (pg/µl) given to 2 d.p. (99% confidence) and precision data (n=1) for PCDD/Fs from analysis of a ten times diluted EPA 16 CS1. Concentration pg/µl RSD % LOD (99) pg/µl 2,3,7,8 TCDF.5 6.2.1 2,3,7,8 TCDD.5 11.1.1 1,2,3,7,8 PeCDF.25 6..3 2,3,4,7,8-PeCDF.25 4.6.3 1,2,3,7,8 PeCDD.25 9.2.5 1,2,3,4,7,8-HxCDF.25 7.7.4 1,2,3,6,7,8-HxCDF.25 4.7.3 2,3,4,6,7,8-HxCDF.25 4.1.2 1,2,3,4,7,8-HxCDD.25 7.7.4 1,2,3,6,7,8-HxCDD.25 6.1.3 1,2,3,7,8,9-HxCDD.25 5..3 1,2,3,7,8,9-HxCDF.25 4.9.3 1,2,3,4,6,7,8-HpCDF.25 5.2.3 1,2,3,4,6,7,8-HpCDD.25 6.8.4 1,2,3,4,7,8,9-HpCDF.25 5.7.3 OCDD.5 7.9.9 OCDF.5 4.8.5 TCDD/F PeCDD/F 1 RT: 32.7 RT: 36.37 RT: 37.3 1 RT: 32.7 33.9 > 24.94 RT: 36.67 RT: 37.3 351.9 > 287.93 1 35.9 > 242.94 RT: 36.63 RT: 37.59 353.9 > 289.93 1 331.94 > 267.97 RT: 37.59 367.9 > 33.93 333.93 > 269.97 32.5 33. 33.5 34. 34.5 35. 369.89 > 35.89 36. 36.5 37. 37.5 38. 38.5 39. 39.5 1 RT: 4.29 HxCDD/F RT: 41.8 RT: 42.15 RT: 44.17 HpCDD/F RT: 46.79 OCDD/F RT: 52.5 1 RT: 4.44 371.82 > 38.86 RT: 41.8 RT: 42.16 47.78 > 344.82 441.76 > 378.8 RT: 44.17 RT: 52.4 RT: 46.79 1 RT: 41.27 373.82 > 31.86 RT: 41.72 49.78 > 346.82 RT: 45.88 RT: 51.65 443.76 > 38.79 1 RT: 41.38 387.82 > 324.86 RT: 41.72 RT: 45.88 423.78 > 36.81 RT: 51.66 457.74 > 394.77 389.82 > 326.85 4. 41. 42. 43. 425.77 > 362.81 44. 45. 46. 47. 48. 49.5 5.5 51.5 52.5 53.5 Minutes Minutes Minutes 459.74 > 396.77 Figure 2. SRM chromatograms of PCDD/Fs after injection of a 1x diluted EPA16B CS1 standard. (TCDD/F.5 pg/µl, PeCDD/F thru HpCDD/F.25 pg/µl, OCDD/F.5 pg/µl)

Quality Control in Routine Sample Batches To evaluate the quantitative performance of the TSQ Quantum XLS Ultra when applied to analytical quality control samples, data was taken and compared with that obtained on currently implemented systems (see Figure 3). These quality control samples included certified reference materials (CRMs) for sediments SETOC 738 and CRM 49 incinerator fly ash. These were all processed through the entire method procedure which included accelerated sample extraction. All of the compound recovery QC criteria specified in EPA 16 and EN1948 were satisfied. This gave confidence that the extraction yielded high recoveries throughout the study. CRM 49 is a highly contaminated incinerator fly ash. This type of sample and level of contamination allows for a great opportunity for interference to occur. The MS/MS system measured consistently higher concentrations for TCDD/F and some penta and hexa furans. This was indeed closer to the true CRM consensus value, so the QC check passed. SETOC 738 is a sediment CRM sample that is much lower level CRM and had good agreement in the calculated concentrations between the and HRMS data. The data on these three types of QC sample all fell within acceptable performance limits for the current methodology suggesting that the selectivity and quantitative performance of the technique is applicable for reporting PCDD/F data in the routine environmental lab. 5 5 Par CRM 49 SETOC 738 % Deviation from HRMS Result -5 2378-TCDF 2378-TCDD 12378-PeCDF 23478-PeCDF 12378-PeCDD 123478-HxCDF 123678-HxCDF 234678-HxCDD 123478-HxCDD 123678-HxCDD 123789-HxCDD 123789-HxCDF 1234678-HpCDF 1234678-HpCDD 1234789-HpCDF OCDD OCDF Figure 3. Mean results for routine laboratory QC samples for the in-house PCDD/Fs method over 3 routine batches of samples. This is plotted as difference to result obtained on the system.the QCs include a precision and recovery standard (PAR), Incinerator fly ash certified reference material (CRM 49) and a sediment certified reference material (SETOC 738).

6 Routine Samples The QC performance was reflected in the real sample batches with generally very good agreement in results between the and approach. Larger deviations in calculated value were reported for incinerator fly ash samples, particularly for the lower chlorinated PCDFs. These differences are thought to arise from selectivity differences in the two techniques. The result remained valid within the quality control criteria specified within the methodology. SRM chromatograms for TCDDs in three different routine environmental sample types are given in Figure 4. These include both quantifying and confirming SRM transitions. The selective detection of the highly significant 2,3,7,8- TCDD congener was achievable in all samples. Calculated concentrations for each congener are given in Table 5 for both the and analyses for routine soil, sediment, and a matrix QC sample. Again, these show a good level of agreement in the calculated result. For the soil samples, the TSQ Quantum XLS Ultra showed confirmed detections of PCDD/Fs for the low concentration samples when no result was reported from. This was due to the lower performance of the system used in this study and not directly related the more sensitive systems available today. Relative Abundance 1 Fly Ash Contaminated Soil Contaminated Sediment 321.89 > 258.93 321.89 > 258.93 321.89 > 258.93 32.2 33.9 2,3,7,8-TCDD 2,3,7,8-TCDD 2,3,7,8-TCDD Relative Abundance 1 319.9 > 256.93 319.9 > 256.93 319.9 > 256.93 RT: 32.15 RT: 33.11 RT: 32.16 RT: 32.2 RT: 33.54 RT: 33.11 RT: 33.11 RT: 33.36 32. 32.5 33. 33.5 32. 32.5 33. 33.5 32. 32.5 33. 33.5 Minutes Minutes Minutes Figure 4. TCDD SRM chromatograms for three different sample types typically analyzed in the environmental laboratory. Left: Fly ash (2,3,7,8-TCDD 31.4 ), Center: Contaminated soil (2,3,7,8-TCDD 1.85 ), Right: Contaminated sediment (2,3,7,8-TCDD 17.9 ). Table 5. Calculated concentrations of TCDD/F congeners in soil and sediment samples run on both and. (ND=not detected) Soil Sediment 1 Sediment 2 SETOC 738 (CRM 2,3,7,8 TCDF.992 1.23 16. 1.4 2.15 1.51 17.9 17.1 2,3,7,8 TCDD ND ND 1.85 2.29 2.3 5.1 23.1 23.9 1,2,3,7,8 PeCDF 1.26 <1.79 25.4 25.4 4.9 4.52 7.36 6.76 2,3,4,7, 8 PeCDF 1.57 1.96 41.5 44.2 1.7 9.29 47.8 45.4 1,2,3,7,8, PeCDD.436 ND 5.49 5.71 9.14 7.95 7.26 6.91 1,2,3,4,7,8,-HxCDF 1.89 1.89 56.1 57.3 64.8 71.9 43.8 45.1 1,2,3,6,7,8,-HxCDF 1.81 2.14 64.8 55. 223 197 15.1 14.7 2,3,4,6,7,8,-HxCDF 2.53 2.83 86.9 91.5 9.47 11.5 2.2 18.4 1,2,3,4,7,8,-HxCDD.271 ND 5.38 6.34 15. 1.9 1.4 8.62 1,2,3,6,7,8,-HxCDD.382.95 8.33 8.58 17.6 16.7 28.1 2.1 1,2,3,7,8,9-HxCDD.469 ND 6.62 6.97 17.5 14. 21.4 22.4 1,2,3,7,8,9-HxCDF.932 ND 25.8 31.4 15.2.4 4.65 5.4 1,2,3,4,6,7,8-HpCDF 12.9 14.2 464 473 5.5 4.58 214 22 1,2,3,4,6,7,8-HpCDD 4.8 5.78 63.4 62.2 18.3 16.6 416 433 1,2,3,4,7,8,9-HpCDF 1.9 3.7 48.8 48.8 68.3 54.4 15.1 15.4 OCDD 24.7 23.8 153 191 6.38 5.38 32 33 OCDF 258 291 475 554 47.7 39.5 29 316

Conclusion The TSQ Quantum XLS Ultra is a highly sensitive and selective system applicable to dioxins and furans analysis in a range of environmental sample types and generates results that perform within current in-house QC criteria. Some differences arise in the calculated concentration between the and analysis. These are thought to be related to the differences in the selectivity mechanism of each system. applied to PCDD/Fs still allows for full isotope dilution quantitation as currently used by systems. TargetQuan 3 software can be used with the TSQ Quantum XLS Ultra to provide the specific calculations required. The Thermo Scientific Dionex ASE Accelerated Solvent Extractor system allows for unattended, efficient extractions from all samples and enabled recoveries well within QC criteria. References 1. Ingelido, A. M.; Brambilla, G.; Abballe, A.; di Domenico, A.; Fulgenzi, A. R.; Iacovela, N.; Lamiceli, L.; Valentini, S.; De Felip, E. Rapid Commun. Mass Spectrom. 212, 26(3), 236 242. 2. Kotz, A.;, Malisch, R.; Wahl, K.; Bitomsky, N.; Adamovic, K.; Gerteisen, I.; Leswal, S.; Schächtele, J.; Tritschler, R.; Winterhalter, H. Organohalogen Compd. 211, 73, 688 691. 3. Silcock, P.; Krumwiede, D.; de Dobbeleer, I.; Huebschmann, H. J.; Kotz, A. 211, Thermo Scientific Application Note 52266. Application Note 36 www.thermoscientific.com 2 Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Thermo Fisher Scientific, Austin, TX USA is ISO 91:2 Certified. Africa-Other +27 11 57 184 Australia +61 3 9757 43 Austria +43 1 333 5 34 Belgium +32 53 73 42 41 Canada +1 8 53 8447 China +86 1 8419 3588 Denmark +45 7 23 62 6 Europe-Other +43 1 333 5 34 Finland/Norway/Sweden +46 8 556 468 France +33 1 6 92 48 Germany +49 6 48 114 India +91 22 6742 9434 Italy +39 2 95 591 Japan +81 45 453 91 Latin America +1 561 688 87 Middle East +43 1 333 5 34 Netherlands +31 76 579 55 55 New Zealand +64 9 98 67 Russia/CIS +43 1 333 5 34 South Africa +27 11 57 184 Spain +34 914 845 965 Switzerland +41 61 716 77 UK +44 1442 233555 USA +1 8 532 4752 AN36_E 7/S