Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM



Similar documents
Poseidon MANUAL

Poseidon Poseidon 1250 Starting Guide 2. Poseidon 1250 Manual 7. Poseidon model Manual

HWg-STE HWg-STE PoE MANUAL

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

PowerShield SNMP Adaptor

Network Management Card. User Manual

Quick Installation Guide Network Management Card

User s Manual Network Management Card

User s Manual UPS SERIES. Network Interface Card UPS-IPCARD. I Rev B

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Application & Quick-Start Guide

User s Manual. Management Software for ATS

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

BEC 6200WZL. 4G/LTE Cellular Broadband Router. Quick Start Guide

Connecting the DG-102S VoIP Gateway to your network

SNMP Web Management. User s Manual For SNMP Web Card/Box

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

Network Power Manager. User Manual

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

Olson Electronics Remote Power Monitoring Meter

Firewall VPN Router. Quick Installation Guide M73-APO09-380

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.

Innovative Electronics for a Changing World INDEX

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

Link Gate SIP. (Firmware version 1.20)

Keri USB-A Connection and Configuration

TemPageR. User s Guide & Reference Manual. Phone Fax Web AVTECH.com

APPLICATION NOTE. CC5MPX Digital Camera and IPn3Gb Cellular Modem 10/14. App. Note Code: 3T-Z

USING THE XPERT2 / 9210B ON A TCP/IP NETWORK

3.5 EXTERNAL NETWORK HDD. User s Manual

Installation and Operation Guide

Room Alert 11E. User s Guide & Reference Manual. Phone Fax Webal AVTECH.com

How to configure Linksys SPA for VOIP Connections

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

Network Management Card

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

IP Power Stone 4000 User Manual

Network Setup Guide. 1 Glossary. 2 Operation. 1.1 Static IP. 1.2 Point-to-Point Protocol over Ethernet (PPPoE)

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Setting up Digi Connect Wi-SP or Digi ConnectPort TS W Devices On a Secured Wireless Network for use with Veriteq viewlinc

TE100-P21/TEW-P21G Windows 7 Installation Instruction

Power Supply SNMP Interface User Manual for SRL versions

TP-LINK TD-W8901G. Wireless Modem Router. Advanced Troubleshooting Guide

SATO Network Interface Card Configuration Instructions

Multi-Homing Dual WAN Firewall Router

Comtrend 1 Port Router Installation Guide CT-5072T

Expert Power Control NET 4x 8212 / 8213

One Port Serial Server Users Manual Model ESP901, ESP901E

How do I configure the wireless printer using a USB or Ethernet cable and install the printer driver in Windows?

Crow Limited Warranty. Print Version 017

Room Alert. User s Guide & Reference Manual. Phone Fax Webal AVTECH.com

Quick Installation Guide

50-Port 10/100/1000Mbps with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

1. Hardware Installation

SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES

Ethernet Radio Configuration Guide

This document is intended to make you familiar with the ServersCheck Monitoring Appliance

Installation and setup guide V 1.0

Follow these steps to prepare the module and evaluation board for testing.

IntraVUE Plug Scanner/Recorder Installation and Start-Up

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module

Quick Installation Guide DSL-2750U/NRU. 3G/ADSL/Ethernet Router with Wi-Fi and Built-in Switch

1 Serial RS232 to Ethernet Adapter Installation Guide

Networking. General networking. Networking overview. Common home network configurations. Wired network example. Wireless network examples

CONFIGURATION OF SATO LAN and WiFi INTERFACES

PART 1 CONFIGURATION 1.1 Installing Dashboard Software Dashboardxxx.exe Administration Rights Prerequisite Wizard

icom Software Update Guide Updating the icom using the Service Tool (ist)

Ultra Thin Client TC-401 TC-402. Users s Guide

Movie Cube. User s Guide to Wireless Function

BiPAC 7800NL. Wireless-N ADSL2+ Firewall Router. Quick Start Guide

Premium Server Client Software

Victoria Combo Remote Control

CPEi 800/825 Series. User Manual. * Please see the Introduction Section

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

USING YOUR DMX PROFUSION

mysensors mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide Information to Users Inside the Box mysensors Ethernet Gateway Quick Start

10/ English Edition 1. Quick Start Guide. NWA1100N-CE CloudEnabled Business N Wireless Access Point

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

WLAN Outdoor CPE For 2.4G. Quick Installation Guide

Debugging Network Communications. 1 Check the Network Cabling

Quick Installation Guide

Installation Guide (No Router)

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

CM1-Mini Wi Drive. Setup Guide Ver 0.1

EC150 BASIC SOFTWARE SETUP GUIDE. Read This First. Easy Clocking EC150 Setup Guide - Page 1

EC500 BASIC SOFTWARE SETUP GUIDE. Read This First. Easy Clocking EC500 Setup Guide - Page 1

MT-350 SMS. Operation Manual. PORTech Communications Inc.

Prestige 314 Read Me First

HP-1000 Powerline Ethernet Adapter

WebMeter Internal Web Server Feature

Application Note Room Alert

Users manual. TCW181B-CM_R1 Page 1

HP-1000 Powerline USB Adapter

Internet Telephony PBX system IPX-1980

User s Manual. Remote Management Card RMCARD202. Intelligent Remote Management Card allows a UPS system to be managed, monitored, and configured

MODBUS TCP to RTU/ASCII Gateway. User s Manual

TelNet Digital Fax. Reference Guide..

Quick Installation Guide

Transcription:

Poseidon 3265 starting guide Poseidon 3265 Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM 1) Connecting Poseidon 3265 1.1) Check DIP switches settings. For installation keep them as shown on the picture on the right (DIP1=Off, DIP2=Off). 1.2) RS-232 serial port for connecting GSM modem and setup purposes. 1.3) Connect power adapter to power supply (230 / 110V) and to power jack of Poseidon. The connector must be plugged in fully, green LED lights up. 1.4) Connect temperature or humidity sensor to IT bus (Temp-1Wire or Humid-1Wire - RJ12 connector), the connector must click. 1.5) Connect Poseidon to Ethernet (use direct cable to Switch, cross-over cable to PC) Green POWER LED on RJ45 connector lights up power supply is OK Yellow LED on the RJ45 connector blinks connection to 10 Mbit network is OK Accessories GSM Modemcom G10 600 312 Poseidon T-Box 600 040 HTemp-Rack19 600 330 Temp-1Wire 1m 600 242 Humid-1Wire 3m 600 279 600 165 Poseidon 3265 Poseidon model 3265 unit with 5 sensors and GSM modem support 600 313 Poseidon 3265 GSM2 Tset Start set - GSM modem, temperature sensors, power supply etc. 600 005 Temp-1Wire 3m Temperature probe, 3m connecting cable (1m=600 242,10m=600 056) 600 311 Temp-1Wire-Outdoor 3m Temperature probe for external use in food industry, cable 3m long 600 279 Humid-1Wire 3m Humidity probe, extending cable 3m long(1m= 600 278) 600 040 Poseidon T-Box Termination-Box for connecting up to 5 sensors, 10 cm long cable 600 280 Poseidon T-Box2 Termination-Box for connecting 2 sensors, 3m long cable

2) Configuring the IP address UDP Config UDP Config program in the root folder of the supplied CD (Windows and Linux version). The program can be downloaded from www.hw-group.com Software -> UDP Config.. Click the icon to run UDP Config the program automatically searches for connected devices Click the Find Devices button to start searching for devices. The program looks for devices on your local network. To identify a particular Poseidon unit, look at its MAC address (printed on the label at the bottom of the unit). Double click a MAC address to open a dialog window with basic device settings. Set up network parameters IP address HTTP Port (default is 80) Mask Gateway IP address Name of your device optional Click the Apply Changes button to save the settings. Note: Contact your network administrator if you are unsure about these settings. DIP1 DIP2 Reset to factory defaults Toggle DIP1 several times within 5 seconds after powering up. Default settings contains none passwords. Disable any configuration changes(online demo mode) While DIP2=On any configuration change disabled. Note: Set Dip2=Off to be able change IP address configuration Oficjalny dystrybutor: www.atel.com.pl 45-231 Opole ATEL ELECTRONICS e-mail: cust@atel.com.pl ul. Oleska 121 tel. +48 (77) 455 60 76 fax. +48 (77) 455 80 56

3) Poseidon setting Internet browser 3.1) type device IP address into your web browser address bar or run UCP Config and click on device IP address in the list of found devices 3.2) Poseidon 3265 webpage Device IP address Contact unique ID Monitored range of each probe Notification about value out of range You can change this text, check manual.. Device name Flash setup detailed configuration Display of SNMP MIB and values.xml Current Value current value of the connected sensor. -999.9 means that the sensor is not available or was initialized after device started. Safe Range Sensor value range that is not in Alarm. Alarm Alert Monitoring of the defined Safe Range exceeded or switch Dry contact input on/off initiate Alarm state. For more information A contact to service organization, this can be changed from Telnet setup. Reading current values XML values.xml file, format described using XSD for download on the main page, detailed comments on XML structure are available in the manual. SNMP description file poseidon.mib can be downloaded on the main page. Standard SNMP ports 161 and 162 can be configured in Flash setup. Modbus/TCP structure description is available in the manual and in application examples. Standard port 502 is opened for reading.

4) Flash Setup probe detection Click on Flash Setup from web page to open this graphics page. Flash Setup requires Macromedia Flash player installed in web browser. If you do not have it, you can download the latest version from Internet or find it on CD: \Poseidon\ install_flash_player_7.msi Sensor detection: Tab Sensors Setup, click on Autodetect Sensors. Using Flash setup you can: Setup names of sensors, Safe Range for alarm and to where the Alarm alert will be sent. Detect and configure GSM modem. Monitor current values, refresh in seconds. Select temperature units ( C, F, K) Setup actual time and select NTP server to synchronize the time. Setup SNMP parameters (Community names & rights) and define where to send SNMP Traps. Setup Alarm alert via email, and test it. Setup security elements: Names and password, ranges of IP addresses. More information can be found in the manual or at www.hw-group.com

5) Connecting GSM modem Following description is related to FW version 3.0.5 and higher. Latest FW can be downloaded from the Poseidon XXXX page. 1. Deactivate PIN code protection of the SIM card. If the function is active, the phone requires PIN code after start up. 2. Setup IP address and connect sensors to Poseidon 3265 according to previous procedure. 3. Connect GSM modem and Poseidon 3265 with supplied RS-232 cable. 4. Insert SIM card to modem slot. 5. Connect power supply to the GSM modem 6. Connect power supply to the Poseidon, wait for about 50 seconds for GSM modem activation. Enable GSM modem Send Test SMS when GSM modem Ready SMS Center number detected automatically from the SIM card, when GSM modem Ready 7. Web browser opens FLASH Setup, tab "Email & SMS Setup" and verify if "Enabled" is checked on "GSM SMS Interface" field. o "RS-232 GSM module" should show "FOUND". o "SMS centre" should show values from SIM card. If not, fill in your operator number. 8. Fill in "Alarm SMS Recipient 1" with target phone number where alarm is sent to and push "SendTestSMS" button.