TRIMMING TECH 150. IVD In vitro diagnostic-medical device. General information. Technical datasheet Trimmingtech150



Similar documents
BENCH TECH 150. IVD In vitro diagnostic-medical device. General information Type of instrument: Bench chemical hood. Technical datasheet BenchTech150

LAMINAR FLOW CABINETS

data sheet DONATELLO Rev. I emiss - 25/10/ PRO03 code Automatic tissue processor DONATELLO

FlowFAST V. Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Freezers - Ultrafreezers. Platilab & Irilab Series

Please also see 10 golden rules for correct Saniflo installation on

OIL SPILL CONTAINMENT CONTAINERS AND RACKING

Power consumption (kw)

IH E Sigma Island 90

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

THE FIRST OF A NEW CLASS OF PRODUCTS

TRIMMING UNIT/DIAMOND MACHINE TST.13

Material test chamber with mechanical convection

Vacuum drying oven for non-flammable solvents

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Clinic Washer-Disinfectors. Washer-Disinfector Line

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

Itho Products for Hot and Boiling water. product-

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

GenStore Archive Cabinet

ECOCIAT. Domestic hot water heat recovery unit

HYDRAULICS. H91.8D/C - Computerized Open Surface Tilting Flow Channel - 10, 12.5, 15 and 20 m long

BAGGAGE HANDLING SYSTEMS. Trastecnica S.p.A. Handling Baggage Systems Edition Rev

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

HEAVY DUTY STORAGE GAS

Incubator with mechanical convection

Laminar Flow Cabinets and Workstations

TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series

Climate chamber with illumination

Saferand easierinstallation

Spetec. Laminar Flow Box. Portable Clean Room Technology

Customer: Cardiff Hospital NHS (United Kingdom) Machine:

Cooking at the Speed of light!

UNITOR VACUUM cleaners

H I G H S P I N W A S H E R E X T R A C T O R S H C 6 0 H C 6 5 H C 7 5 H C H C H C 1 6 5

Linkeo 19" freestanding cabinets

FF30. Flexicon. Operator s Manual. FF30-F In-feed Rotary Table. OPERATOR S MANUAL Serial Number yyww xxxx. Filling and Capping System

L_PTL12_C01_E_P_TOKIOK_L_PTL12_C01_E_P_TOKIOK :50 Seite 17. Leonard Hausgeräte 2012 Leonard domestic appliances 2012

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

1.1 DIMENSIONS AND WEIGHT PAG LOAD CENTRE FOR LIFTING PAG STORAGE CONDITIONS PAG. 2

LAMINAR FLOW FOR ALL YOUR NEEDS

EXTeRUS. EXTeRUS - With patented design, able to join technology. and quality of materials with a charming shape. Unique

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Offering more. Series

Cooktop Low-Profile Ventilation Hoods

Installation and Service Instructions. Neutralization System Part no Grünbeck part no

Stove-boiler for solid fuels KW Directions for use and assembling

Phoenix. Accessories

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

CHAPTER 29 VOLUMES AND SURFACE AREAS OF COMMON SOLIDS

1. Description. 2. List of Accessories included A B C F G H

SF15K SF05KSS, SF10KSS

BLADE S-MAX Cabinet for Blade Server

1. Geo Vertical 2. Geo Horizontal

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

VCE VET ENGINEERING STUDIES

FVA/A1 saturated-steam sterilizer

CoolTeg Plus Chilled Water (CW) version: AC-TCW

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Rotary screw compressors kw 5,5 7, , bar MODULO

ASALAIR BIOHAZARD CABINET MODEL ATLANTIC CYTOCABINET 1200 CLASS II TYPE A2 COD MICROBIOLOGICAL SAFETY CABINET CLASS II TYPE A2

STERILIZERS, LABORATORY DRYING OVENS


Complete units. Complete underfloor box for one Modul 45 socket and two data connection sockets. Complete service outlets

Gas Instantaneous Water Heater

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

Modular Glovebox Systems Gas Purifier Units Antechambers Accessories

STOVE-BOILER FOR SOLID FUELS Directions for use and assembling

OT 40L / 90L. Laboratory Steam Sterilizers

Cleanroom Solutions Ltd T: F: E: W:

Professional dishwashers. Blue line. the environmentally friendly brand

Flexit Central Vacuum Cleaner

V94 BULK TAPE DEGAUSSER

BAR - the build guide. best practice for bar construction

Installation Guide. Bath and Wall Surrounds SERIES B

TECHNICAL INFORMATION

16/32 Channel 1U Rack Mount CCTV Power Supply

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

Attachment G-1: Pit Latrine Diagram. Fig E.1a: Pit Latrine. Fig E.1b: Plan View of Twin Pits

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

Installation, operation and maintenance manual TX 35A

TMS TANK MANAGEMENT SYSTEM

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Product catalogue, pipe and sewer cleaning systems

Heating oven with mechanical convection

Vertical and Benchtop Autoclaves for Life Sciences. Laboratory Line

AIR PUMPS & ACCESSORIES

Donut Robot Mark I Mark VI

Dehumidifier D 850E. - Instruction manual version 02

Make Your Own SNOWBREEZE AC For Rs.1500 ($30) Can be converted into an energy saving and humidified room heater in winter

OPERATING AND MAINTENANCE MANUAL

We ll help you determine your containment needs

OPL BASIC. Dosing System for Professional Laundry machines. Contents

HP switch LP switch Discharge thermo Comp. Surface thermo

Spetec Laminar Flow Systems. Operating Instructions

REQUIREMENT 5. Light Switches, Electrical Outlets, Thermostats, and Other Environmental Controls in Accessible Locations


Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/ Ø90x160mm W200xH385xD (Net:28)

Transcription:

IVD In vitro diagnostic-medical device CND code: W0202059016 - CIVAB code: TRIMMING TECH 150 General information Type of instrument: Aspirated hood for histology. Model: Trimming Tech 150. Code: Description: Manufacturer: Distributor in Italy: 50-150-001 (sink on the left). 50-150-002 (sink on the right). 50-150-003 (2 sinks). Aspirated hood designed for cutting and reduction of histological samples. Designed to prevent biological and chemical risk during manipulation of anatomy finds preserved in formalin. Provided with vapours aspiration system from the working surface, the frontal side and the top; predisposed for fumes discharge outside. Bio-Optica Milano S.p.A. Bio-Optica Milano S.p.A. Marketing: Since 2012. Page 1 of 10

Dimensional features Overall dimensions in mm Working usable dimensions in mm Weight Width Depth Height Width Depth Top height ca. 160 kg 1500 750 2360 1160 640 900 Water sink dimensions in mm Formalin sink dimensions in mm Width Depth Height Width Depth Height 400 400 200 150 300 100 Electrical connections Power supply: Rated output: Nominal current: Power supply socket: Protection device: Emergency power supply: 230V~ 50/60Hz. 1 Kw. 10A, with delayed fuses. Situated on the left back side at a height of ca. 2 metres. Magnetothermic switch. Not necessary. Other connections Water connections: Hot water connection: 1/2. Cold water connection: 1/2. Waste water connection: 1 1/4 standard siphon placed at ca. 40 cm from the ground (at ca. 20 cm with garbage disposal unit) on the back side of the hood. Its position depends on the sink placement. Fumes discharge: Connection of external instruments: The hood is provided with 250 mm collector on its upper side in order to allow the connection to the hospital s centralized canalization system. The hood is provided with n. 2 Schuko universal power supply sockets for a possible connection of external instruments, placed in the lower frontal side externally the working area (one on the right, the other one on the left). Possibility of enable/disable the power supply to the sockets. Lighting N. 2 led tubes, total 1500 lux, 19 Watt/each. N. 2 adjustable halogen spotlights of 50 Watt, 150 lux. Page 2 of 10

Structural features Structure made entirely of satinized, thickness 15/10, AISI 304 stainless steel with smooth surface and rounded edges (in compliance with the regulation in force). 6/7 mm accident prevention stratified frontal glass with electric vertical slide to contain toxic fumes inside the hood (in compliance with the regulation in force). Run stop at 230 mm from work surface (descent), at 500 mm from work surface (ascent). The system of glass lifting is provided with manual unlocking in case of emergency. Automatic function of increase of the ventilation during the phase of lifting of the frontal glass. 6/7 mm accident prevention stratified side glasses in order to increase internal visibility, avoid draughts near the work surface and contain fumes inside the hood (in compliance with the regulation in force). Shelf placed in the frontal side over the working plane (see arrow in the photo). Shelf placed in the central side (see arrow in the photo). White polyethylene plate for pieces reduction - 350x450x20 mm (WxDxH) - provided with N. 4 support feet 30 mm high. Antistatic and antislip adjustable feet allow to get a perfect horizontal position of the working surface. Noise level < 56 db (A). N. 2 sinks 400x400x200 mm and N. 1 formalin sink 150x300x100 mm. Removable filtering basket for formalin sink. It avoids the obstruction of the discharge tube to the cans, keeping the solid waste also of small dimensions. Since it is removable, it can be removed and properly washed when necessary. Cover for formalin sink. Formalin dispensing system including: 10 litres load can with filter and pump, supplying tap with pedal control, 10 litres formalin discharge can with level sensor and visual and acoustic alarm. Canholder trolley provided with handbrakes and front door. The trolley is provided with system of fumes aspiration with collector situated on the back side that can be removed in case of maintenance. The trolley can contain also two cans of 20 litres. Throttle tap of interception formalin discharge to avoid possible accidental leaks during the replacement of the formalin can. The tap must be closed before replacing the can and reopened after the replacement. Tap for adjustment of shower water pressure (see arrow in the photo). Water dispensing tap for basins wash (see arrow in the photo). Arrangement for system of acquisition of image. Page 3 of 10

Cover for formalin sink Filtering basket Working surface features Weldings-free, thickness 10/10, AISI 304 stainless steel surface, provided with liquids containing rim. Sinks (n. 1 for hood 90, n. 2 for hoods 130 and 150, n. 3 for hood 180) dimensions 400x400x200 mm of which n. 1 for hood 90, 130, 150, n. 2 for hood 180 with perforated removable surface of support in stainless steel. The 7 mm holes allow water draining in the sink and fumes aspiration from the top itself. The sinks assigned to the cut are provided with system of aspiration of fumes. On request are available surface and sinks in stainless steel AISI 316. Double washing system consisting in: 1) Shower, provided with extensible flexible arm, to clean the whole working surface provided with independent tap for the adjustment of the pressure of the water 2) Cleaning system inside the basins assigned to the cut (only for hoods with more than one sink). Hot/cold water sink provided with pedal control distributor and stainless steel smaller sink for formalin discharge. Both of them are placeable on request on the right or on the left. Page 4 of 10

Flows Instrument Flow m³/hr with 1 filter Flow m³/hr with 2 filters MODELS 150 800 770 Page 5 of 10

Control panel Touch screen monitor for the control and the visualization of all the functions. 13 14 15 16 17 5 6 3 4 12 7 8 9 11 10 Page 6 of 10

Principali funzioni Hood ignition general switch (1). Emergency main switch (2). Key halogen spotlights ignition/switching off (3). Key uv lamp ignition (4). Key power supply of current to the external sockets (5). Key led lights ignition/switching off (6). Key automatic switching off setup of uv lamp measured in minutes (minimum 15 max 20 ) (7). Elapsed time from ignition of uv lamp measured in minutes (8). Key alarms silencing (9). Space alarms visualization (10). Key input in the submenu (11). Keys frontal glass scent and descent (12). Key automatic ventilation enabling in function of the movement of the frontal glass (13). Keys increase and decrease of ventilation in manual modality (14). Percentage increase bar of electrofan speed (15). Key fast increase of ventilation measured in percentage (16). Percentage visualization of electrofan speed (17). Page 7 of 10

Aspiration/filtration system Filter Prefilter Trimming Tech hoods are provided with: N. 1 anti-spark three-phase electrofans adjustable through inverter (preinstalled). N. 1 synthetic fibres prefilter (preinstalled) to retain possible impurities and improve the filter s efficiency. N. 1 alumina filter for formalin (preinstalled), whose replacement happens from the frontal side simply and cleanly. Instead of alumina filter, it is possible to ask for activated charcoal filter. Arrangement for HEPA filter housing. The hood is provided with 250 mm collector on its upper side in order to allow the connection to the hospital s centralized canalization system for fumes discharge outside. The electrofan allows fumes aspiration from the perforated working surface (over the collecting basin), the frontal grid (under the shelf) and the grid placed on the upper part. The air is purified passing through prefilter and filter and can be discharged in this way: 1) FAN PREFILTER + FILTER DISCHARGE OUTSIDE THROUGH A NON-ASPIRATED CANALIZATION SYSTEM (draining pipe not longer than 3 metres, with minimum diameter of 250 mm). 2) FAN PREFILTER + FILTER DISCHARGE OUTSIDE THROUGH AN ASPIRATED CANALIZATION SYSTEM. Aspiration system diagram Page 8 of 10

Standard components included in the equipment Item Description Code 1 Polyethylene plate for pieces reduction. 50-500-050 2 Shower provided with extensible flexible arm. 50-500-051 3 Filtering basket for formalin sink. 50-500-052 4 Stainless cover for formalin sink. 50-500-053 5 Alumina filter for formalin. 50-F017 6 Prefilter. 50-F007 Optional accessories Item Description Code 1 Swivel stool. 40-300-450 2 Footboard. 40-300-451 3 Macro Digital Imaging System version in trimming tech with pc touch screen. (*) 50-200-000 4 Macro Digital Imaging System version in stand with pc touch screen. 50-200-001 5 Macro Digital Imaging System version in trimming tech with pc desk top. (*) 50-200-100 6 Macro Digital Imaging System version in stand with pc desk top. 50-200-101 7 Ruler divided into millimetres. 50-500-054 8 Garbage disposal unit with pedal control. 50-500-055 9 U.V. lamp with self-switching off programming and rolling protection curtain. 50-500-057 10 Formalin suction filter (included in formalin dispensing system). 50-500-058 11 Stainless steel filter for formalin sink. 50-500-059 12 Magnetic knife holder. 50-500-060 13 Paper handkerchief distributor. 50-500-061 14 Stainless steel filter for water sink. 50-500-062 15 Hood 150 lower panel right side. (*) 50-500-065 16 Hood 150 lower panel left side. (*) 50-500-066 17 Cold light articulated lamp with 3 dioptres magnifier. 50-500-069 18 Spare lamp for UV system 50-500-057. 50-500-070 19 Activated charcoal filter in alternative to alumina filter 50-F017. 50-F018 20 HEPA filter. 50-F005 (*) These accessories can be installed only at the time of production, not afterwards. Page 9 of 10

Photo of Macro Digital Imaging System integrated in the hood. Page 10 of 10