LIEBERT VNSA Installation Sheet



Similar documents
Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert AC4. User Manual

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

MCR1900 Media Converter 19-Slot Chassis

HP UPS R1500 Generation 3

GEU Port Gigabit Switch

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

HMI display Installation Guide

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

HM-W536 Install Guide

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

No Phone Line II-48 System

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

TrueAlarm Fire Alarm Systems

Moxa EtherDevice Switch

Advantium 2 Plus Alarm

How To Wire Wireline Cable To A Cell Phone (New Zealand)

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

ALL8808POE. 8 Port Gigabit PoE+ Switch. Manual

5800 Temperature Sensor Cable Assembly

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Applied Electronics. Commercial Dimming System UPDATE NOTICE

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

ATS Overhead Table Shelf System INSTRUCTION MANUAL

About the BitStorm 6051 POTS Splitter

Remote Power Panels with Breakers

Installation Instructions

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

Cisco Unmanaged Rackmount Switches

INSTALLATION INSTRUCTIONS

BX7000 Multi-Access Gateway Getting Started Guide

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Liebert Liqui-tect Monitoring System. User Manual

Provides one channel for Ethernet over existing

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

Canopy Surge. User Manual

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

2013 Wireless Video Intercom INSTALLATION GUIDE

UniStream CPU-for-Panel

Refer installation of power supplies to qualified service personnel.

KZ0224UW INSTALLATION MANUAL SURGE PROTECTED CCTV POWER SUPPLY 24V AC, 5 AMP KZMI /12/01

Quick Installation Guide. 16-Port 10/100Mbps Fast Ethernet Switch

Installation Instructions for FT-10 Network PowerCommand ATS Communication Module (NCM) Kits and

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

DCF Optimized Rack System

Long Range Ethernet Extender

Solar monitoring gateway quick start guide

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Installation Guide Solar Connect-11

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Installation & Weatherproofing Guide for ENCOM Broadband Radios

100 - SERIES NETWORK SWITCHES QUICK START GUIDE

No Phone Line System. Quick Start Guide NPL II. 1.0 Installation

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

16-Port and 24-Port 10/100 Switches

Cooktop Low-Profile Ventilation Hoods

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

Quick Start Guide. WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide. Cisco Small Business

Quick Installation Guide. EtherFast 10/100M Switch. Model No.: SP624R.

Quick Start Guide. RV0xx Series Routers

Liebert Universal Monitor

Installation Instructions. Wireless Adapter/Repeater. Introduction Rev C

Hotwire 5620 RTU Installation Instructions. Contents. Hotwire 5620 RTU Overview. Document Number 5620-A2-GN11-40 September 2001

T1 Backhaul Connectivity Solution All Products :: Application Note

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011


FUSION R400 RAID USB 3.0

RAY-MAX Integrated Solar Power Strip

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Provides one channel for Ethernet over existing

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

Perle 10/100 Ethernet Media Converters

ColorDial Pro Easily configure and control LED light shows

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

QSE-CI-NWK-E Control Interface

Transcription:

LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display mounted on the front, as shown at right. Liebert icom models permit interconnecting cooling units that are equipped with Liebert icom controls, allowing the units to communicate. One or two 8-port switches, providing a total of 8 or 16 Ethernet ports. The example below shows a model with two 8-port switches. The number of ports available varies by model (see Table 1 for details). All models have a power supply that requires connection, as shown below. FRONT OF Liebert vnsa (Liebert icom model shown) Liebert icom display Key lock INSIDE VIEW 16-port model shown UPPER SWITCH (all models) Power supply (all models) LOWER SWITCH (16-port models only) Knockouts for cable access (top and bottom) Liebert icom Display Model Firmware / Liebert Products Supported vnsa8-icom vnsa16-icom PA Liebert DS Liebert CW Liebert Challenger 3000/ Liebert Challenger ITR with Liebert icom Control Liebert HPM Liebert PeX Yes vnsa8-icom-cr vnsa16-icom-cr CR Liebert CRV vnsa8-icom-xp vnsa16-icom-xp XP Liebert XDP Liebert XDC No vnsa8 vnsa16 1

Packing Contents The Liebert vnsa comes standard with these components: Liebert icom display on front of enclosure (Liebert icom models only) One 8-port switch inside enclosure (8-port models) or Two 8-port switches inside enclosure (16-port models) Universal power supply and hardwire adapter Keys (2) to panel door lock User manual for Liebert vnsa User manual for industrial rail switch User manual for Liebert icom (Liebert icom models only) Factory Connections The Liebert vnsa has factory-wired connections to simplify installation, depending on the model (see Figure 1): Models with Liebert icom display The upper switch is factory-connected to the Liebert icom display. 16-port models The upper switch is factory-connected to the lower switch. All models Proper power connections are factory-wired between the 3-pin terminal blocks on each switch. Figure 1 Factory-wired connections UPPER SWITCH (all models) Cable connecting upper switch to lower switch (16-port models only) Cable connecting upper switch to Liebert icom display (Liebert icom models only) LOWER SWITCH (16-port models only) 2

Switches Each switch has eight 10/100 Mbps twisted pair RJ45 ports, allowing connection of Ethernet-ready devices to available ports. The switch supports Ethernet 10 Mbps and Fast Ethernet 100 Mbps using twisted-pair RJ45 ports, allowing connection of Ethernet-ready devices. The devices support switched Ethernet networks in accordance with IEEE standard 802.3. Three automatic features autonegotiation, autopolarity and autocrossing allow the use of standard network cables (CAT5 or better) for connection to each port, rather than a special crossover cable. The switch detects and makes adjustments for the network s speed and transmission mode, polarity and transmit-andreceive pins. Refer to the Industrial Rail Switch user manual for more details. Connecting Devices Use CAT5 or better network patch cables with RJ45 connectors to connect devices to available ports. Number of Ports Available The number of ports available for Ethernet-ready devices varies by model, as shown in Table 1. Models with the Liebert icom display use one port for connection to the Liebert icom display. Models with two switches use two ports to interconnect the switches. Table 1 Number of available ports by model # Ports Needed to Connect: Maximum # Cooling Units That May Be Connected Liebert icom Display Model Total # Ports To Liebert icom Display Upper & Lower Switches # Ports Available Cooling Units With Small Liebert icom Display Cooling Units With Large Liebert icom Display vnsa8-icom 8 1 7 Yes No vnsa8-icom-cr 8 1 7 7 units 3 units vnsa8-icom-xp 8 1 7 vnsa16-icom 16 1 2 13 vnsa16-icom-cr 16 1 2 13 13 units 6 units vnsa16-icom-xp 16 1 2 13 vnsa8 8 8 8 units 4 units vnsa16 16 2 14 14 units 7 units Number of Cooling Units That May Be Connected The maximum number of cooling units that may be connected depends on the Liebert vnsa model and the size of the Liebert icom display in the cooling units, as shown in Table 1. Refer to the Liebert icom user manual for additional details on connecting Liebert cooling products. 3

Connect Power to the Liebert vnsa The Liebert vnsa requires AC power (100-240VAC single phase) for proper operation. A universal power supply (12V, 1.5A) is installed inside the enclosure, with a hard-wired connection for 120V or 230V operation.! WARNING Risk of electric shock. Can cause injury or death. Disconnect all local and remote electric power supplies before working within. NOTICE The Liebert vnsa is designed for use on properly grounded (earthed) 100-240VAC singlephase power, 50Hz or 60Hz. The ground wire for the power lead must be wired to the earth ground terminal (stud located next to the universal power supply). This equipment is intended to be installed by a qualified and certified electrician who must review and approve customer supplied wiring and circuit breakers, verify correct input and grounded (earthed) connections to ensure compliance with technical standards and national and local electrical codes. NOTE The connector must be unplugged prior to installation. A field-supplied power cord may be used in place of the hardwire adapter provided. Power Supply Wiring Instructions 1. Loosen and remove the screw from the adapter cover. Loosen cover screw 2. Remove the cover. D Fl Remove cover N N E L 3. Loosen the two screws that secure the wire clamp. Remove the screws and the wire clamp. N E L Screws Wire clamp 4

4. Connect the incoming electrical service ground wire to the earth ground terminal inside the enclosure, shown below. Earth ground terminal 5. Feed wires including a ground wire from the earth ground terminal in Step 4 through the rubber strain relief into the adapter. Note: 16 AWG stranded maximum wire size. N E L Rubber strain relief 6. Strip the insulation on each wire to expose 5/8" (16mm). N E L N E L Strip insulation to expose 5/8" (16mm) 7. Loop each wire around the appropriate terminating screw and tighten. Each screw is labeled: N = Neutral for 120V; Line for 220V applications E = Earth ground L = Line Neutral for 120V; Line for 220V applications (white) Earth grounding conductor (green) Line (black) 8. Replace the wire clamp and the two screws removed in Step 3 to secure wires. 9. Close the adapter cover and tighten the screw from Step 1. 5

Enclosure The Liebert vnsa enclosure features a key lock for added security. The enclosure is made of metal to accommodate secure conduit fittings and protect components against environmental debris. 14.25" (361.95mm) The enclosure is designed for easy wire routing and terminations. Access slots for network cables and power wiring are located on both the top and bottom of the enclosure. 12" (304.8mm) The enclosure is 3.3" (84mm) deep, allowing for recess mounting in a wall. The enclosure may also be surfacemounted. The enclosure houses the power supply and one or two 8-port rail switches. Some models have a Liebert icom display mounted on the front of the enclosure. FRONT VIEW (all models) Enclosure Mounting Considerations The Liebert vnsa must be installed indoors. The enclosure must be secured to a wall, either mounted on the surface of a wall or recessed with the front flush against a wall. The method of mounting depends on the application, the location of equipment to be monitored and the type of wall the enclosure will be mounted on. The Liebert vnsa should be mounted where it can be easily accessed. The site must have electrical service and must permit routing of network cables to the unit s RJ45 ports. The wall material must be capable of supporting the weight of the Liebert vnsa: see Specifications on page 8. TOP/BOTTOM VIEW (vnsa8 & vnsa16 models) TOP/BOTTOM VIEW (Liebert icom models) 7/8" (22mm) 3.3" (84mm) 4.175" (106mm) 6

Surface Mounting After determining where to place the enclosure, check to ensure that you have all the hardware required to install the panel on the surface of a wall. Obtain the needed tools and material. Required Tools Electric drill (if surface is too hard to drive screws without pilot holes) Screwdriver Marker to denote layout of holes Four screws, each #10 Mounting the Panel NOTE Removing the conduit knockouts before mounting the Liebert vnsa on the wall will ease installation and prevent strain on the mounting hardware and wall. NOTICE Check building plans and other relevant documents to determine whether mounting the Liebert vnsa at the selected location might cause cutting or otherwise damaging electrical or communication wiring or pipes. 1. Mark the wall for mounting holes, using the back of the unit as a template (see Figure 2). Figure 2 Mounting dimensions 0.88" (22mm) 12-1/2" (318mm) 0.213" (5mm) A 0.694" (18mm) 10" (254mm) 0.375" (10mm) Detail A Mounting Slot Back Plate (inside view) 1" (25mm) 0.213" (5mm) (two places) 2. Drill holes, if required, to install the four #10 screws that will secure the Liebert vnsa to the wall. Clean up the debris. 3. If the wall material is not strong enough to hold the screws securely, use wall anchors. 4. Install the top two screws the screw heads must be small enough to slip through the larger, bottom portion of the pear-shaped mounting slot in the Liebert vnsa (see Figure 2). The screws must also be large enough to extend over the edges of the top of the mounting slot. 5. Hang the Liebert vnsa on the screws, letting the panel slip down until the screws are in the smaller, upper portion of the slot. 6. Tighten the screws until they are snug. 7. Insert the remaining two screws in the bottom holes on the back of the panel and tighten. 7

Specifications MODEL vnsa8-icom vnsa8-icom-cr vnsa8-icom-xp vnsa16-icom vnsa16-icom-cr vnsa16-icom-xp vnsa8 / vnsa16 Power 100-240VAC, single-phase, 47-63 Hz, 0.4A Dimensions, W x D x H - in. (mm) 14.25 x 3.3 x 12 (362 x 84 x 305) Weight - lb. (kg) 11 (5) 10 (4.5) Enclosure Type Mounting Surface Communication Ambient Operating Environment NEMA 1, painted steel IP20 - indoor use Building wall or structural member Ethernet 10/100 Mbps RJ45 ports, autonegotiation, autopolarity and autocrossing 32 F to 140 F (0 C to 60 C); 0 to 95% relative humidity, non-condensing. Wiring Specifications Connection Supported Wire Types Maximum Wire Length Rating Ethernet 10/100 Mbps CAT 5 RJ45 Ethernet cable 328 ft. (100m) N/A Universal power supply 16 AWG Stranded Contact local electrician 300V Ordering Information Quantity Part # Liebert vnsa with: Firmware / Liebert Products Supported vnsa8-icom vnsa16-icom 8 ports, Liebert icom display 16 ports, Liebert icom display PA Liebert DS Liebert CW Liebert Challenger series Liebert HPM Liebert PeX vnsa8-icom-cr vnsa16-icom-cr 8 ports, Liebert icom display 16 ports, Liebert icom display CR Liebert CRV vnsa8-icom-xp vnsa16-icom-xp 8 ports, Liebert icom display 16 ports, Liebert icom display XP Liebert XDP Liebert XDC vnsa8 vnsa16 8 ports 16 ports Liebert Corporation 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Telephone: 1-800-877-9222 Facsimile: 1-614-841-6022 www.liebert.com 2006 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. Liebert is a registered trademark of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. SL-18840_REV1_05-10 8