Certificate of Calibration No 131 00835



Similar documents
Calibration Certificate

Calibration Service Selection Guide

Type examination certificate No. CH-MIOO BauartprufzertifIkat

The Calibration Chain: Role of BIPM,

Estimates of Uncertainty of the Calibration of Balances

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Weight Calibration ComparatorPac TM Simple Calibration Efficient Workflow Reliable Results

CCM.M-K3.1 comparison / 50 kg Mass

Form and content of COOMET сertificate for reference materials for composition and properties of substances and materials

Calibration method for conductivity cells

IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS

OIML R RECOMMENDATION. Edition 2004 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION , E 2. Weights of classes E 1 , F 2 , M 1 2 , M 1

S Davidson, M Perkin, M Buckley

WEIGHTS AND MASS STANDARDS

Gravimetric determination of pipette errors

Measuring equipment in a laboratory.

KALIBRERINGSBEVIS. 25 temperature loggers Ecoguard model TS , identification se table of results.

How To Test A Titrette And Digital Burette

NMI R 125 Measuring Systems for the Mass of Liquids in Tanks

RECOMMENDATION. on the Evaluation of Quality Management System of National Metrology Institutes

4-1 Ratios, Rates, and Unit Rates

OIML D 18 DOCUMENT. Edition 2008 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Process Measurement Assurance Program For U.S. State Metrology Laboratories 1

LAB14 EDITION 4 November 2006

ERRATUM: OIML R 60 RECOMMENDATION. Edition 2000 (E) ORGANISATION INTERNATIONALE ORGANIZATION INTERNATIONAL. Metrological regulation for load cells

Welcome to Physics 40!

Balance Calibration A Method for Assigning a Direct-Reading Uncertainty to an Electronic Balance

GMP 11. Good Measurement Practice for Assignment and Adjustment of Calibration Intervals for Laboratory Standards

High-Energy Electron Beam Therapy Dosimetry with Ionisation Chambers

Training Material for Balances (1) Prepared by R&D Division 1. Marketing Department A&D Company, Limited

OPERATOR S MANUAL SUPPORTED TORQUE CALIBRATION BEAM. Part Number Issue 4 Original Instructions (English)

EUROLAB 25 years. The role of metrology and testing to characterize materials and products. EUROLAB 25th Anniversary Seminar

Measurement and Calibration

Measuring instruments in industry.

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

A Code of Practice for the Calibration of Industrial Process Weighing Systems

Conductivity measurement on pure water according to the recommendations of the USP Pharmacopoeia USP24-NF19

SWISS MADE. Series 320 XB MASTER. Analytical. Precision


Industrial Balances PREMIUM Series 490 IBK/ITK/ISK

VERIFYING CALIBRATION OF WEIGHING DEVICES USED FOR LABORATORY TESTING

American Association for Laboratory Accreditation

ROLE OF THE APEC SPECIALIST REGIONAL BODIES

METRIC CONVERSION TABLE Multiply By To Obtain Millimetres Inches Millimetres Feet Metres Feet Kilometres 0.

GENERAL REQUIREMENTS FOR THE PROGRAMME OF REFERENCE MATERIAL CERTIFICATION IN SERIAL PRODUCTION

(Uncertainty) 2. How uncertain is your uncertainty budget?

How To Determine Uncertainty In A Source Stream

Core Fittings C-Core and CD-Core Fittings

NIST Calibration Services for Liquid Volume NIST Special Publication

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Accreditation according to ISO/IEC in Europe. Historic EA Europeing Accreditation Assessment Experience from Technical assessment

When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.

JCGM 104:2009. Evaluation of measurement data An introduction to the Guide to the expression of uncertainty in measurement and related documents

20099 Sesto San Giovanni (Ml) Italy. (MID) RichtIinie 2004/22/EG des Europaischen Parlaments und des

International Organization for Standardization

MIKROS SYSTEMS TRAFFIC EVENT LOGGING. HSWIM Calibration Instruction TEL EQUIPMENT MS ISSUE 3

Industrial gas meters G10, G16, G25, G40, G65

Handbook of Weighing Applications Balances and Scales Used as Measuring and Test Equipment in a Quality System

Density and Archimedes Principle

Packaged-Products for Parcel Delivery System Shipment 70 kg (150 lb) or Less

Glassware Calibration Guidelines Laura B. Secor and Dwight R. Stoll, 02/01/2012 Adapted from National Bureau of Standards Document

User checks and maintenance of laboratory balances

01 The Nature of Fluids

Case study Realistic and best uncertainties with humidity instruments

NMI R 51 Automatic Catchweighing Instruments

American Association for Laboratory Accreditation

A PRIMARY CALIBRATION SYSTEM FOR THE SUPPORT OF HIGH PERFORMANCE GAS FLOW TRANSFER STANDARDS

General Physics 1. Class Goals

Calibration of Glassware

The Determination of Uncertainties in Charpy Impact Testing

Type examination certificate No. CH-MI e Bauartprüfzertifikat

How To Test For Totalizing Weight

Three Methods for Calculating the Buoyant Force Gleue: Physics

Calibration. How can you get lower costs for the calibration? What is traceability? What is measurement uncertainty? What is calibration?

Uncertainty of Force Measurements

EURAMET 1197 SUPPLEMENTARY BILATERAL COMPARISON OF HYDRAULIC GAUGE PRESSURE STANDARDS UP TO 50 MPa

Nursing 131 Household to Metric Conversion

(The opinion exchange between Turkey and EU is continuing. ) Regulation on installation of lighting and light-signaling

AP Physics 1 and 2 Lab Investigations

OIML R RECOMMENDATION. Edition 2014 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

The entire document shall be read and understood before proceeding with a test. ISTA 3B Page 1 of 35

Summary of Requirements for ISO 14001:2004 February 24, 2005

Higher Education Institutions in Switzerland

NOTE: FOR PROJECTS REQUIRING CONTRACTOR MIX DESIGN, THE DESIGN PROCEDURES ARE SPECIFIED IN THE SPECIAL PROVISIONS OF THE CONTRACT.

Inventory management within a food factory

Regulation (EU) No 305/2011 (CPR) and its mechanisms and potential consequences on environmental and sustainability tools in the construction sector

General and statistical principles for certification of RM ISO Guide 35 and Guide 34

Regulations for custody transfer measurements: meeting the needs? Focus on liquid flow measurement systems/applications

OIML R RECOMMENDATION. Edition 2011 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

This document is a preview generated by EVS

SUPPLIER QUALITY PROGRAM, V (U)

CRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES

Guidelines on the Calibration of Static Torque Measuring Devices

APPENDIX B. The Risk Pool Game B.1 INTRODUCTION

Michelin Luxembourg SCS. Société en Commandite Simple. Audited annual accounts for the year ended December 31, 2010

Transcription:

Schweizerische Confederation Confederazione Confederaziun Eidgeno5senschaft suisse svizra Federal Department of Justice alld Police FDJp Federal Office of Metrology METAS Certificate of Calibration No 131 00835 Object Order Applicant Traceability Date of Calibration Swiss Committee Kilogram 1 kg Kilogramme Conforme a la Loi du 18 Germinal an 3, presente Ie 4 Mess an 7. Fortin F Brass, in a leather box Historical comparison of mass and conventional mass in the context of the exhibition: Ferdinand Rudolf Hassler (1770-1843) - Swiss Pioneerfor US Surveying, Mapping and Standards, to be presented at METAS, July 8 - August 11, 2007. Federal Office of Metrology METAS Lindenweg 50 CH-3003 Bern-Wabern The reported measurement values are traceable to national standards and thus to internationally supported realizations of the SI-units. 04-07.05.2007 Marking CH-3003 Bern-Wabern, 08 May 2007 For the Measurements Section Mechanics 7 /;f-2t k:crav' Stefan Russi Dr Henri Baumann, Head of Section ~ Mutual recognition 1.- This certificate is consistent with Calibration and Measurement Capabilities (CMCs) that are included in Appendix C CIPMMRA of the Mutual Recognition Arrangement (MRA) drawn up by the International Committee for Weights and Measures. Under the MRA. all participating institutes recognize the validity of each other's calibration certificates and measurement reports for the quantities, ranges and measurement uncertainties specified in Appendix C (for delails see www.bipm.org). This document may ~ot be published or forwarded other than in futl >I' "IT'" Lindenweg,0, CH-J003 Bern-Wabern, Tel. +4' J1 3' 33 lll. www.metas.ch

Schweizeri,che Eidger1o$sertschaf l COl1f~d~ratiol1 sui,se Confede.razior1e Confederaziun 5vizra Extent of the Calibration The mass and conventional mass of the Committee Kilogram has been determined, in accordance to the International Recommendation OIML R 111-1, 'Weights of classes E" E 2, F l, F 2, M l, M l _2, M 2, M 2 _3 and M 3 ", edition 2004 (OIML: International Organization of Legal Metrology). Measurement procedure The mass and conventional mass of the Committee Kilogram was determined on the mass comparator M_One, by comparison with METAS reference standards sets number 4, number 14 and number 336 by substitution weighing. Picture 1: Committee Kilogram inside the primary Mass Comparator of Metas This document may nm be published or forwarded other then in full, 215 M"''' Undenweg 50, CH-lDO} Bern-Wobem, T.L +4'l' 3. 33"' www.metas.ch

Schweizerische Eidgenossenschaft Confederation suisse ConfecJerazione Svizzer(l Confederaziun svizra Picture 2: Committee Kilogram within its original protection case Picture 3: Imprint at the bottom of the weight ThiS document may not be published or forwarded other than in full "IT" Linoenweg So, CH-JooJ Bern-Wabern, Tel. +4' 3' J~13 " I, www.m.l. ch

Schweizerische Confederation Conlederazione Conlederaziun Eidgenossenschaft suisse svizra Picture 4: Engraved label on the top of the leather coated container TillS document may no! be pubhslled or kl1wardedotl\er than in full '" "IT" Undenweg So, CH'3003 Bern.Waber1l. Tel. "-4' 3' 12 13 "'. www.mel.'.d>

Schweizerische Eidg 1105S 115chaft Confederatiol1 suisse Confederazione Svizzeril Confederaziun svizril Measurement conditions The average ambient conditions during the measurement Air temperature: (20.39± 0.02) C. Air density: (1.111± 0.003)kg/m' were the following: Measurement results After having applied the air buoyancy correction to each series of substitution weighings, the following values for the mass deviation and for the conventional mass deviation has been evaluated: Nominal Identification Mass value deviation Conventional Uncertainty of Density mass deviation measurement (kg/m') 1 kg 1853-90.37-81.55 0.10 8500 Uncertainty of Measurement The reported uncertainty of measurement is stated as the combined standard uncertainty multiplied by a coverage factor k = 2. The measured value (y) and the associated expanded uncer~ tainty (U) represent the intelval (y ± U) which contains the value of the measured quantity with a probability of approximately 95%. The uncertainty was estimated following the guidelines of the ISO. The measurement uncertainty contains contributions originating from the measurement standard, from the calibration method, from the environmental conditions and from the object being calibrated. The long-term characteristic of the object being calibrated is not included. ThIS document may not be published or forwarded other than in full M'"'' Undel1weg SO.CH.}oo] ~.Wa~rn. T~1.+4']' }2 ]]111. www.mera. ch