Industrial gas meters G10, G16, G25, G40, G65

Size: px
Start display at page:

Download "Industrial gas meters G10, G16, G25, G40, G65"

Transcription

1 Industrial gas meters G, G6, G5, G4, G65

2 Commercial Gas Meter G The gas meter AM-G is designed for gas is equivalent to 6m/h of air of density of, kg/m. Qmax = 6 m/h =, m/h Qn = m/h V = 5 dm Pmax =,5 bar 99999,999 m dm/h. Average pressure loss P [mbar] Gas meter in its standard version is equipped with pulse magnet. Pulse transmitter (see photo) can be added at any time ( imp =,m). 6,8 kg. -. EN 59 / OIML R - - EG 7/ Flow rate Q (m/h) air natural gas APATOR METRIX SA Piaskowa 8- Tczew, Poland tel fax Flow rate Q (m /h)

3 Commercial Gas Meter G6 The gas meter AM-G6 is designed for gas is equivalent to 5m/h of air of density of, kg/m. Qmax = 5 m/h =,6 m/h Qn = 6 m/h V = 5 dm Pmax =,5 bar ,99 m dm/h. Average pressure loss P [mbar] Gas meter in its standard version is equipped with pulse magnet. Pulse transmitter (see photo) can be added at any time ( imp =,m). 6,8 kg. - EN 59 / OIML R -. 7/8/EWG Flow rate Q (m/h) air natural gas APATOR METRIX SA Piaskowa 8- Tczew, Poland tel fax Flow rate Q (m/h)

4 Commercial Gas Meter G5 The gas meter G5 is designed for gas is equivalent to 4m/h of air of density of, kg/m. Qmax = 4 m/h =,5 m/h Qn = 5 m/h V = dm Pmax =, bar ,99 m dm/h Gas meter in standard version is equipped with pulse magnet. Pulse transmitter ( imp =,m) can be added at any time.. Average pressure loss P [mbar] kg. - EN 59 / OIML R -. - EG 7/8 4 Flow rate Q (m/h) air natural gas APATOR METRIX SA Piaskowa 8- Tczew, Poland tel fax Flow rate Q (m /h)

5 Industrial Gas Meter G4 The gas meter G4 is designed for gas is equivalent to 65m/h of air of density of, kg/m. Qmax = 65 m/h =,4 m/h Qn = 4 m/h V = 65 dm Pmax =, bar ,99 m dm/h Gas meter in standard version is equipped with pulse magnet. Pulse transmitter ( imp =,m) can be added at any time.. Avarage pressure loss P [mbar] 9 kg.5. - EN 59 / OIML R -.5-7/8/EWG Flow rate Q (m/h) air natural gas APATOR METRIX SA Piaskowa 8- Tczew, Poland tel fax Flow rate Q (m/h)

6 Industrial Gas Meter G65 The gas meter G65 is designed for gas is equivalent to m/h of air of density of, kg/m. Qmax = m/h =,65 m/h Qn = 65 m/h V = 65 dm Pmax =, bar ,99 m dm/h Gas meter in standard version is equipped with pulse magnet. Pulse transmitter ( imp =,m) can be added at any time. Avarage pressure loss P [mbar] 9 kg.. - EN 59 / OIML R -. 7/8/EWG Flow rate Q (m /h) air natural gas APATOR METRIX SA Piaskowa 8- Tczew, Poland tel fax Flow rate Q (m/h)

Fluxi 2000/TZ Turbine Gas Meter

Fluxi 2000/TZ Turbine Gas Meter Gas Fluxi 2000/TZ Turbine Gas Meter Turbine gas meters are flow meters. The flow of gas turns a turbine wheel, and thus, the rotating speed of the turbine is proportional to the linear speed of the gas.

More information

T U R B I N E G A S M E T E R

T U R B I N E G A S M E T E R TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss

More information

. g .,, . . , Applicability of

More information

How To Use A Corona Mdi 110

How To Use A Corona Mdi 110 CORONA MDI 110 APPLICATION Domestic water meter FEATURES 4 Modular multi-jet domestic meter with inductive scanning (without magnetic influence) 4 System capability, with standard applicable pulse output

More information

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET APPLICATION Fully electronic compact water meter with impeller scanning for recording volume. Highly accurate recording of all billing data at medium temperatures up to 90 C. FEATURES 4 Electronic sensor

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass

More information

www.apator.com Financial results of Apator Capital Group 25.11.2015 1

www.apator.com Financial results of Apator Capital Group 25.11.2015 1 Financial results of Apator Capital Group 25.11.215 1 Financial results of Apator Capital Group 215 PLN (') 9M 215 9M 214 Change y/y Sales 556 91 517 48 7,5% Gross profit on sales 151 857 154 627-1,8%

More information

TURBINE GAS METER SM-RI-X TURBINE GAS METER EM-SMRI-X-17 NATIONAL ACCREDITATION OF CERTIFICATION BODIES

TURBINE GAS METER SM-RI-X TURBINE GAS METER EM-SMRI-X-17 NATIONAL ACCREDITATION OF CERTIFICATION BODIES TURBINE GAS METER SM-RI-X TURBINE GAS METER SM-RI-X NATIONAL ACCREDITATION OF CERTIFICATION BODIES EM-SMRI-X-7 GENERAL The INSTROMET SM-RI-X turbine meter is an integrating flow meter for the measurement

More information

MEASUREMENT OF THE LNG DELIVERED AND THE GAS REDELIVERED

MEASUREMENT OF THE LNG DELIVERED AND THE GAS REDELIVERED MEASUREMENT OF THE LNG DELIVERED AND THE GAS REDELIVERED 1) INTRODUCTION... 2 2) MEASUREMENT OF THE LNG DELIVERED... 2 2.1) DETERMINING THE AMOUNT OF LNG DELIVERED... 2 2.2) MEASUREMENT SYSTEM FOR THE

More information

Biographies of the candidates for the Members of the Supervisory Boards of Apator SA

Biographies of the candidates for the Members of the Supervisory Boards of Apator SA Biographies of the candidates for the Members of the Supervisory Boards of Apator SA Janusz Niedźwiecki Mr Janusz Niedźwiecki was born in 1958, Gdansk University of Technology graduate: Electrical Department

More information

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT Kazuto Otakane, Tokyo Gas Co., Ltd Katsuhito Sakai, Tokyo Gas Co., Ltd Minoru Seto, Tokyo Gas Co., Ltd 1. INTRODUCTION Tokyo Gas s new gas meter,

More information

www.kem-kueppers.com info@kem-kueppers.com

www.kem-kueppers.com info@kem-kueppers.com www.kem-kueppers.com info@kem-kueppers.com Calibration of flow meters according to DIN EN ISO/IEC 17025:2005 Introduction... 2 Calibration laboratory... 3 Description of the calibration process... 3 Calibration

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass

More information

IFC 070 Technical Datasheet

IFC 070 Technical Datasheet IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer

More information

AMTRON E-30 Compact heat and cooling meter

AMTRON E-30 Compact heat and cooling meter AMTRON E-30 Compact heat and cooling meter Application The compact AMTRON E-30 meter is used for energy consumption measurements for heating and cooling applications in small premises such as apartments,

More information

Series DFMT Digital Paddlewheel Flowmeter

Series DFMT Digital Paddlewheel Flowmeter Series DFMT Digital Paddlewheel Flowmeter Bulletin F-DFMT Specifications - Installation Operating Instructions -/8 [00] -/ [8] -/8 [00] A The Series DFMT Digital Paddlewheel Flow Transmitter provides instantaneous

More information

HYDRUS ULTRASONIC METER

HYDRUS ULTRASONIC METER HYDRUS APPLICATION HYDRUS is a static water meter based on the ultrasonic technology. This technology enables accurate calculation of water consumption and eliminates measuring deviations caused by sand,

More information

ARIB TR-T12-34.925 V3.0.0. Specific Absorption Rate (SAR) requirements and regulations in different regions

ARIB TR-T12-34.925 V3.0.0. Specific Absorption Rate (SAR) requirements and regulations in different regions ARIB TR-T12-34.925 V3.0.0 Specific Absorption Rate (SAR) requirements and regulations in different regions Refer to "Notice" in the preface of ARIB TR-T12 for Copyrights. Technical Report 3rd Generation

More information

Pomeranian Special Economic Zone 2014-06-27 10:22:24

Pomeranian Special Economic Zone 2014-06-27 10:22:24 Pomeranian Special Economic Zone 2014-06-27 10:22:24 2 The Pomeranian Special Economic Zone is situated at 19 locations in three regions of the northern part of Poland. The Pomeranian Special Economic

More information

Take total control of your HVAC system with cost-saving flow and thermal energy meters

Take total control of your HVAC system with cost-saving flow and thermal energy meters Take total control of your HVAC system with cost-saving flow and thermal energy meters Because you can t manage what you don t measure usa.siemens.com/pi Answers for Industry. Contents Introduction 03

More information

Calibration Certificate

Calibration Certificate P.O. Box 87-0087 Phone:856-686-1600 Fax:856-686-1601 www.troemner.com e-mail: troemner@troemner.com SECTION 1: Page 1 of 7 Pages SECTION 2: APPROVED SIGNATORY Joseph Moran SECTION 3: PERSON PERFORMING

More information

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure

More information

Chainmail handing curtains. Technical Data Sheets. curtains FOIN COTTE DE MAILLES. Réalisation Pascale Lion et Gaëlle Lukàcs

Chainmail handing curtains. Technical Data Sheets. curtains FOIN COTTE DE MAILLES. Réalisation Pascale Lion et Gaëlle Lukàcs curtains 1 Chainmail handing curtains Foin cotte de mailles - Sperian protection gloves plancher bas Tel. : +33 1 49 90 39 14 - Fax : +33 1 49 90 39 16 - E-mail : cottedemailles@foin.fr - Immeuble Edison

More information

Reporting: one report / group. The results of the carryover load calculations will also be reported to Metsä Fibre, Rauma.

Reporting: one report / group. The results of the carryover load calculations will also be reported to Metsä Fibre, Rauma. Carryover load Your task is to use the obtained experimental result from the probe measurement in combination with the information given in this handout to calculate the carryover load (g/nm 3 dry flue

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM SLAM-SHUT VALVE Type OSE Process Management TM DESCRIPTION The purpose of the OSE slam shut valve is to totally and rapidly cut off gas flow when the outlet pressure exceeds or drops below the setting.

More information

The number of revolutions is proportional to the passed volume. The rotation is transferred to a mechanical index, which indicates this volume.

The number of revolutions is proportional to the passed volume. The rotation is transferred to a mechanical index, which indicates this volume. RVG and RVG-ST Rotary Gas Meters Alications Media: Natural gas, town gas, inert gases Industry: Gas suly, stove manufacturers, chemical industry. Tasks: Measurement, control and automatic regulation. Brief

More information

Certificate of Calibration No 131 00835

Certificate of Calibration No 131 00835 Schweizerische Confederation Confederazione Confederaziun Eidgeno5senschaft suisse svizra Federal Department of Justice alld Police FDJp Federal Office of Metrology METAS Certificate of Calibration No

More information

Datalogger DL/N 70 Version: 28.03.2012

Datalogger DL/N 70 Version: 28.03.2012 Datalogger DL/N 70 Version: 28.03.2012 Technical Specifications Pressure measuring range (mh20) 1... 5 > 5... 20 > 20... 250 Overpressure 3 bar 3 x FS ( 3 bar) 3 x FS Burst pressure > 200 bar > 200 bar

More information

FIELD TESTS OF FUEL EFFICIENCY MAGNETS J A CRABB JULY 1997 SWEEG REPORT 80

FIELD TESTS OF FUEL EFFICIENCY MAGNETS J A CRABB JULY 1997 SWEEG REPORT 80 FIELD TESTS OF FUEL EFFICIENCY MAGNETS J A CRABB JULY 1997 SWEEG REPORT 80 List of symbols T f average temperature at the flow header, C T r average temperature at the return header, C f average water

More information

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic

More information

Gases. Macroscopic Properties. Petrucci, Harwood and Herring: Chapter 6

Gases. Macroscopic Properties. Petrucci, Harwood and Herring: Chapter 6 Gases Petrucci, Harwood and Herring: Chapter 6 CHEM 1000A 3.0 Gases 1 We will be looking at Macroscopic and Microscopic properties: Macroscopic Properties of bulk gases Observable Pressure, volume, mass,

More information

DM Series CONTENTS. 1. Features 3. 2. Applications 3. 3. General 4. 4. Calibration 5. 5. Dimensions 6. 6. Specifications 7. 7. Calibration procedure 7

DM Series CONTENTS. 1. Features 3. 2. Applications 3. 3. General 4. 4. Calibration 5. 5. Dimensions 6. 6. Specifications 7. 7. Calibration procedure 7 DM Series CONTENTS 1. Features 3 2. Applications 3 3. General 4 4. Calibration 5 DM-509-(M/T/S)X-(01/02) & DM-509-(H3/H5)-(01/02) 5. Dimensions 6 6. Specifications 7 7. Calibration procedure 7 The DM Series

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Greenhouse gas emissions from direct combustion of various fuels (e.g. grain dryer)

Greenhouse gas emissions from direct combustion of various fuels (e.g. grain dryer) Greenhouse gas emissions from direct combustion of various fuels (e.g. grain dryer) The most significant greenhouse gas from direct combustion is carbon dioxide (CO 2 ) Large number of other compounds

More information

Line-Mounted Valves L Series

Line-Mounted Valves L Series Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series

More information

J5423 The Radisson, Malelane WET Services Installation Description of Design Intent & Works Information Document

J5423 The Radisson, Malelane WET Services Installation Description of Design Intent & Works Information Document J5423 The Radisson, Malelane WET Services Installation Description of Design Intent & Works Information Document January 2011 QM Issue/revision Issue 1 Revision 1 Revision 2 Revision 3 Remarks Issue 1

More information

COMBIMASS. Technical Data COMBIMASS eco-bio +

COMBIMASS. Technical Data COMBIMASS eco-bio + COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments

More information

PACE1001 Barometer Precision Barometric Indicator and Recorder

PACE1001 Barometer Precision Barometric Indicator and Recorder GE Measurement & Control PACE1001 Barometer Precision Barometric Indicator and Recorder A high precision Druck indicator and recorder, designed for barometric monitoring in laboratories, airfields and

More information

RF safety at base station sites

RF safety at base station sites RF safety at base station sites CONTENTS 1 Purpose and scope................................................. 2 2 Introduction........................................................ 2 3 Basic information...................................................

More information

DECLARATION OF PERFORMANCE NO. HU-DOP_TN-212-25_001

DECLARATION OF PERFORMANCE NO. HU-DOP_TN-212-25_001 NO. HU-DOP_TN-212-25_001 Product type 212 (TN) 3,5x25 mm EN 14566:2008+A1:2009 NO. HU-DOP_TN-212-35_001 Product type 212 (TN) 3,5x35 mm EN 14566:2008+A1:2009 NO. HU-DOP_TN-212-45_001 Product type 212 (TN)

More information

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms Data Sheet Models MT 3809 & 3819 Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms Broad range of flow capacities 2% Full scale accuracy Versatile

More information

Experience from implementing a metering solution for subsea and topside multiphase flow metering

Experience from implementing a metering solution for subsea and topside multiphase flow metering Experience from implementing a metering solution for subsea and topside multiphase flow metering by David E. Olaussen, FMC Technologies Co-Author: Kåre Kleppe, Statoil ASA Content Introduction Best Practice

More information

Calculation of flow rate from differential pressure devices orifice plates

Calculation of flow rate from differential pressure devices orifice plates Calculation of flow rate from differential pressure devices orifice plates Peter Lau EMATEM - Sommerschule Kloster Seeon August -, 008 Contents Introduction - Why using dp-devices when other principles

More information

226 ежглеяис тгс йубеямгсеыс (теувос деутеяо) 80 90 : 3 CxHy CO2 H2O. CxHy + (x+y/4) O2 xco2 + y/2 H2O + Q () CO ( ).

226 ежглеяис тгс йубеямгсеыс (теувос деутеяо) 80 90 : 3 CxHy CO2 H2O. CxHy + (x+y/4) O2 xco2 + y/2 H2O + Q () CO ( ). 226 ежглеяис тгс йубеямгсеыс (теувос деутеяо) I 80 90 1 / / 1 (C) ( 2 ) CO 2 2 21 % 79 % 3 CxHy CO2 H2O CxHy + (x+y/4) O2 xco2 + y/2 H2O + Q () 4 CO2 ( ) 5 CO2 ( ) CO ( ) 6 1atm 100C 7 8 ( ) 9 10 11 12

More information

DECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001

DECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001 NO. HU-DOP_TD-25_001 Product type TD 3,5x25 mm EN 14566:2008+A1:2009 NO. HU-DOP_TD-35_001 Product type TD 3,5x35 mm EN 14566:2008+A1:2009 NO. HU-DOP_TD-45_001 Product type TD 3,5x45 mm EN 14566:2008+A1:2009

More information

Tolerance +/- 0,5 mm, +/- 0,2 mm. Length 15-350 mm ( standard) SLOTS. 9 5/8 x 36 Ibs/ft. 4 1/2 x 9,5 Ibs/ft. Slotted casing

Tolerance +/- 0,5 mm, +/- 0,2 mm. Length 15-350 mm ( standard) SLOTS. 9 5/8 x 36 Ibs/ft. 4 1/2 x 9,5 Ibs/ft. Slotted casing Slotted casing Tube API 5CT, grade J/K55, R1, R2, STC: 4 1/2 x 9,5 Ibs/ft number of slots / meter number of ranges on circumference number of ranges per linear meter 24 4 6 9 5/8 x 36 Ibs/ft 48 8 6 Slotted

More information

Hi-Tech Dive. For Experienced Divers

Hi-Tech Dive. For Experienced Divers Hi-Tech Dive For Experienced Divers ... 5... 5... 5... 6... 7... 8... 8... 9... 11... 12... 13... 15... 19... 20 PPO2... 21 PPO2... 22... 23... 24... 25... 28... 28... 28... 29... 30... 35... 36 2 Shearwater

More information

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL FUEL CONSUMPTION MEASUREMENT AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL Description The combination of AVL Fuel Mass Flow Meter and AVL Fuel Temperature Control is a high precise and continuous

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding

More information

Measurement While Drilling (MWD) Tools

Measurement While Drilling (MWD) Tools Measurement While Drilling (MWD) Tools 2 www.micon-drilling.de Phone +49.5144.49360 Company profile The MICON-Drilling GmbH is a worldwide operating service company, specialized in sales and rental of

More information

HV reed relays K-551H, K-552H K-553H, K-554H, K-555H, K-556H form A contact (normally open) for PCBs

HV reed relays K-551H, K-552H K-553H, K-554H, K-555H, K-556H form A contact (normally open) for PCBs 50-5 Wrocław, ul. Krakowska 6, Poland tel. (+8) 7/-65-5, fax (+8) 7/-58-59 HV reed relays K-55H, K-55H K-55H, K-55H, K-555H, K-556H K-55H K-55H K-55H K-55H K-555H K-556H.CONTACT 0 Breakdown voltage min

More information

The Axial Flow Valve. Class 300/600. sales@elster-instromet.co.uk www.elster-instromet.com SERIES

The Axial Flow Valve. Class 300/600. sales@elster-instromet.co.uk www.elster-instromet.com SERIES The Axial Flow Valve SERIES Class 300/600 sales@elster-instromet.co.uk www.elster-instromet.com THE AXIAL FLOW VALVE - SERIES 300/600 A UNIQUE REGULATOR What is the Axial Flow Valve? The Axial Flow Valve

More information

Eco Green Labs India Pvt. Ltd., Ground Floor, Plot No. 100, New Sidco Industrial Estate, Srinagar, Hosur, Tamil Nadu

Eco Green Labs India Pvt. Ltd., Ground Floor, Plot No. 100, New Sidco Industrial Estate, Srinagar, Hosur, Tamil Nadu Last Amended on - Page 1 of 5 I. DIMENSION $ 1. PLAIN PLUG S Upto Ø 100 mm 1.1 m Using ULM > Ø100 mm to Ø 300 mm 2.4 m 2. PLAIN RING S Upto Ø 100 mm 1.7 m Using ULM >Ø100 mm to Ø 300 mm 3.6 m 3. THREAD

More information

Regulations for custody transfer measurements: meeting the needs? Focus on liquid flow measurement systems/applications

Regulations for custody transfer measurements: meeting the needs? Focus on liquid flow measurement systems/applications Regulations for custody transfer measurements: meeting the needs? Focus on liquid flow measurement systems/applications Contents - Requirements in OIML publications - Uncertainty effects on trade - Back

More information

Type examination certificate No. CH-MIOO1-11052-00 BauartprufzertifIkat

Type examination certificate No. CH-MIOO1-11052-00 BauartprufzertifIkat Federal Department ofjustice and Police FDJP Federal Office of Metrology METAS Ceiflcation Body METAS-Cert Type examination certificate No CH-MIOO1-11052-00 BauartprufzertifIkat Applicant: GGIOANOLA SRL

More information

4-1 Ratios, Rates, and Unit Rates

4-1 Ratios, Rates, and Unit Rates Warm Up Problem of the Day Lesson Presentation Lesson Quizzes Warm Up Divide. Round answers to the nearest tenth. 1. 420 23.3 2. 73 3.5 18 21 3. 380 23.8 4. 430 23.9 16 18 Learn to work with rates and

More information

Sizing Pressure Regulators & Control Valves

Sizing Pressure Regulators & Control Valves Sizing Pressure Regulators & Control Valves ( ( Sizing the Pressure Regulators Sizing of regulators is usually made on the basis of Cg valve and KG sizing coefficients. Flow rates at fully open position

More information

1 WATERFLUX - Comparisonon COO 2010-08-17. Rectangular Magmeter in water applications

1 WATERFLUX - Comparisonon COO 2010-08-17. Rectangular Magmeter in water applications 1 WATERFLUX - Comparisonon COO 2010-08-17 Rectangular Magmeter in water applications Jef Neven KROHNE WATERMETERS $3000 EMF Price C&I (mechanical) water meters Residential water meters $30 Water Metering

More information

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory

More information

Unit 8A: Systems in Action (Pg. 2 85) Chapter 2: Getting to Work (pg. 28 55)

Unit 8A: Systems in Action (Pg. 2 85) Chapter 2: Getting to Work (pg. 28 55) Unit 8A: Systems in Action (Pg. 2 85) Chapter 2: Getting to Work (pg. 28 55) Name: Date: 2.1: Physical Systems: Simple Machines (Pg. 30 35): Read Pages 30-35. Answer the following questions on pg. 35:

More information

DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: 0.05 40376 m 3 /h. Accuracy: ± 0.3% of reading ± 0.

DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: 0.05 40376 m 3 /h. Accuracy: ± 0.3% of reading ± 0. Magnetic Inductive Flowmeter for conductive fluids measuring monitoring analysing MH Measuring range: 0.05 40376 m 3 /h ccuracy: ± 0.3% of reading ± 0.01% x Q max p max : PN40; t max : -20... +150 C O

More information

SITRANS F flowmeters SITRANS FUS080. SITRANS FUS380/FUE380/SONOCAL 3000 4/179. flow sensor pipe, 4 transducers/transducer cables and a transmitter

SITRANS F flowmeters SITRANS FUS080. SITRANS FUS380/FUE380/SONOCAL 3000 4/179. flow sensor pipe, 4 transducers/transducer cables and a transmitter Overview SITRANS FUS380 flow sensor pipe, transducers/transducer cables and a transmitter SITRANS FUS080. The unit is available in a compact or a remote version with up to 30 meter distance from flowmeter

More information

SITRANS F flowmeters SITRANS F M. Battery operated water meter MAG 8000 4/93

SITRANS F flowmeters SITRANS F M. Battery operated water meter MAG 8000 4/93 Overview (MAG 8000/MAG 8000 CT) Intelligent information, easy to access Advanced information on site Data logger for consumption profile Advanced statistics and diagnostics Add-on communication module

More information

Gravimetric determination of pipette errors

Gravimetric determination of pipette errors Gravimetric determination of pipette errors In chemical measurements (for instance in titrimetric analysis) it is very important to precisely measure amount of liquid, the measurement is performed with

More information

FM Transmitting Line REFERENCES

FM Transmitting Line REFERENCES FM Transmitting Line REFERENCES ELECTROLINK IS UNI EN ISO 9001:2000 Certified Cover FM ELECTROLINK INSTALLATIONS 2008 2008 2008 2008 2008 2006 2006 2006 2005 2004 2004 2003 n 1-3x20kW +10kW FM Transmitting

More information

Specifications for Volkswagen Industrial Engine

Specifications for Volkswagen Industrial Engine Volkswagen 1 industrial engine Specifications for Volkswagen Industrial Engine AFD 1.9 ltr. TDI diesel engine EURO 2 Volkswagen AG, Wolfsburg Volkswagen AG reserves the right to introduce amendments or

More information

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic

More information

Pump Formulas Imperial and SI Units

Pump Formulas Imperial and SI Units Pump Formulas Imperial and Pressure to Head H = head, ft P = pressure, psi H = head, m P = pressure, bar Mass Flow to Volumetric Flow ṁ = mass flow, lbm/h ρ = fluid density, lbm/ft 3 ṁ = mass flow, kg/h

More information

POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE)

POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE) IM213P-MC 0312 0003 POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE) INSTRUCTION MANUAL To the Owner PLEASE READ THIS INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist

More information

Directorate for the Built Environment Building Standards Division

Directorate for the Built Environment Building Standards Division Directorate for the Built Environment Building Standards Division Energy Management Solutions Ltd Investigation of measures to improve the energy performance of a existing building: Retail JUNE 2009 Report

More information

DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button

DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button collective/synoline600 AlgoRex Synova Manual call point to all fire detection system control

More information

GPS satellite receiver for world wide application

GPS satellite receiver for world wide application Operating manual GPS satellite receiver for world wide application Versions: Article Number Auxiliary Voltage Interface 111.9024.45 H1: AC/DC 88V...264V D2: RS485 111.9024.46 H2: DC 18V...72V D2: RS485

More information

MICHELIN CARGOXBIB and XP 27

MICHELIN CARGOXBIB and XP 27 TRAI LERS The trailer tires that protect your soil MICHELIN CARGOXBIB and XP 27 Sizes MICHELIN CARGOXBIB 500/60 R22.5 155D 560/60 R22.5 161D 600/50 R22.5 159D 710/45 R22.5 165D 600/55 R26.5 165D Sizes

More information

Torque motors. direct drive technology

Torque motors. direct drive technology Torque motors direct drive technology Why Direct Drive Motors? Fast and effective Direct-drive technology in mechanical engineering is defined as the use of actuators which transfer their power directly

More information

Micro Motion ELITE CMFS Series Meter

Micro Motion ELITE CMFS Series Meter Revolutionize your Coriolis measurement technology Micro Motion ELITE CMFS Series Meter Introducing Emerson s Micro Motion Elite CMFS Series METER Our ELITE CMFS meter delivers unmatched, real-world performance

More information

SITRANS F M MAG 8000 Precise Metering with battery powered water meters. sitrans f

SITRANS F M MAG 8000 Precise Metering with battery powered water meters. sitrans f SITRANS F M MAG 8000 Precise Metering with battery powered water meters sitrans f s Compact and remote installation made simple Easy to install Simply bolt into place before operation Minimized inlet and

More information

- mark gas burners Cuenotherm NC.4 - NC.6 - NC.9 14.5-90kW.

- mark gas burners Cuenotherm NC.4 - NC.6 - NC.9 14.5-90kW. - mark gas burners Cuenotherm NC.4 - NC.6 - NC.9 14.5-9kW. Low NO x Comprehensive control panel Gas rack Low NOx combustion head Strong light alloy pressuremoulded housing Electronic ignition transformer

More information

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz J. Klima, R. Ščehovič Department of Physics, Faculty of Natural Sciences, University of Mathias Bel, Tajovského

More information

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology Plastic Flow Meters for gases & liquids, using TROGAMID* & POYSUFONE Technology Applications Monitoring & Control of processes for: Water & Waste Water Treatment Chemical, Petrochemical & Paper Pharmaceutical,

More information

Small Coreless DC Motors

Small Coreless DC Motors CL Series 3 to 25 W Coreless DC Motors Smooth-running, optimized-performance coreless DC motors Small Coreless DC Motors Allied Motion s CL series of small coreless DC motors provides maximized performance

More information

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater SALES SPECIFICATION SC7640 Auto/Manual High Resolution Sputter Coater Document Number SS-SC7640 Issue 1 (01/02) Disclaimer The components and packages described in this document are mutually compatible

More information

Elegant and Reliable Wireless Detectors for the Home. Industry-leading digital detection technologies

Elegant and Reliable Wireless Detectors for the Home. Industry-leading digital detection technologies WIRELESS Next Wireless s Elegant and Reliable Wireless s for the Home Industry-leading digital detection technologies Unsurpassed catch performance and false alarm immunity Unique pet-immune detection

More information

BLASTING SYSTEMS. Turbine blasting systems. Air blasting systems. Automatic Painting plants

BLASTING SYSTEMS. Turbine blasting systems. Air blasting systems. Automatic Painting plants BLASTING SYSTEMS Turbine blasting systems Air blasting systems Automatic Painting plants 1, Dust Collector 2, Cyclone Separator 3, Sand (shot) Storage Hopper 4, Bucket elevator 5, Primary separator 6,

More information

PRELIMINARY INVESTIGATION OF DIESEL ENGINE WITH ADDITIONAL INJECTION OF ETHYL ALCOHOL

PRELIMINARY INVESTIGATION OF DIESEL ENGINE WITH ADDITIONAL INJECTION OF ETHYL ALCOHOL Journal of KONES Internal Combustion Engines 2002 No. 3 4 ISSN 1231 4005 PRELIMINARY INVESTIGATION OF DIESEL ENGINE WITH ADDITIONAL INJECTION OF ETHYL ALCOHOL Andrzej Kowalewicz, Grzegorz Pawlak Technical

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications P.O. Box 26, FIN-00421 Helsinki, FINLAND Tel: +358 9 894 91 Fax: +358 9 8949 2485 Email: industrialsales@vaisala.com www.vaisala.com The Vaisala

More information

Endress Hauser. prowirl 70 Vortex Flow Measuring System. Operating Manual. Nothing beats know-how. BA 018D/06/en/03.97 Nr.

Endress Hauser. prowirl 70 Vortex Flow Measuring System. Operating Manual. Nothing beats know-how. BA 018D/06/en/03.97 Nr. BA 018D/06/en/03.97 Nr. 50072931 Valid as of software version 1.1.XX prowirl 70 Vortex Flow Measuring System Operating Manual Endress Hauser Nothing beats know-how Safety Instructions Prowirl 70 Safety

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE. SIT Group 820 NOVA mv MULTIFUNCTIONAL CONTROL FOR GAS THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE PIN 3AP700/2 SINGLE-KNOB MULTIFUNCTIONAL

More information

Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF

Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF Table of Contents Section 1 - General Introduction 1.1 1 Principles Of Operation 1.2 1 Reshaping The Velocity Profile

More information

Incorrect use or failure of pressure regulators

Incorrect use or failure of pressure regulators Pressure Regulators Kosan Crisplant is able to offer regulators that may be used in different kind of applications for industrial or domestic use. Pressure regulators are necessary in order to enable the

More information

Modeling and Simulations of Cavitating and Bubbly Flows

Modeling and Simulations of Cavitating and Bubbly Flows Muon Collider/Neutrino Factory Collaboration Meeting Riverside, California, January 27-31, 2004 Modeling and Simulations of Cavitating and Bubbly Flows Roman Samulyak Tianshi Lu, Yarema Prykarpatskyy Center

More information

ELECTROMAGNETIC DISC BRAKES

ELECTROMAGNETIC DISC BRAKES ELECTROMAGNETIC DISC BRAKES TYPE 66E 15/30 52.121 Hand release Lining wear adjustment Torque adjustment 4 holes ø13 DISC SIZE Ø A Braking torque Nm Regulated from (40-100%) Reaction on the shaft N Control

More information

GONAR - SYSTEMS INTERNATIONAL TUNNELING AND GEOTECHNICAL SYSTEMS

GONAR - SYSTEMS INTERNATIONAL TUNNELING AND GEOTECHNICAL SYSTEMS GONAR - SYSTEMS INTERNATIONAL TUNNELING AND GEOTECHNICAL SYSTEMS 1 GSI System Technical Data Technical Data Unit R25 R32L R32N R32S R38 R51N T76N T76S T103N T103S Outer mm 25 32 32 32 38 51 76 76 103 103

More information

O R G A N I C P R O D U C T L I N E

O R G A N I C P R O D U C T L I N E A P O W E R F U L D E S I G N F O R S U C C E S S F U L P O I N T O F S A L E O R G A N I C P R O D U C T L I N E U P R I G H T E X T R U S I O N Aluminium Anodized or Ral Powder Coated W: 130mm 3.64 Kg/m

More information

Primary Voice Services over BreezeMAX Carrier class telephony and broadband data for new and incumbent networks

Primary Voice Services over BreezeMAX Carrier class telephony and broadband data for new and incumbent networks Primary Voice Services over BreezeMAX Carrier class telephony and broadband data Solution Paper Highlights Primary voice/broadband data services for residential, SOHO users Seamless integration with V5.2

More information

Solid Oxide Fuel Cell Gas Turbine Hybrid Power Plant. M. Henke, C. Willich, M. Steilen, J. Kallo, K. A. Friedrich

Solid Oxide Fuel Cell Gas Turbine Hybrid Power Plant. M. Henke, C. Willich, M. Steilen, J. Kallo, K. A. Friedrich www.dlr.de Chart 1 > SOFC XIII > Moritz Henke > October 7, 2013 Solid Oxide Fuel Cell Gas Turbine Hybrid Power Plant M. Henke, C. Willich, M. Steilen, J. Kallo, K. A. Friedrich www.dlr.de Chart 2 > SOFC

More information

Thermal Response Test Equipment. Specifications

Thermal Response Test Equipment. Specifications Thermal Response Test Equipment Specifications Made by: László Kiss Executive manager mechanical engineer, specialist automation and geothermal engineer and Barna Erdélyi mechanical engineer, geophysicist

More information

1800C and 1800C-HC Series Service Regulators. Technical Bulletin

1800C and 1800C-HC Series Service Regulators. Technical Bulletin and -H Series Service Regulators Technical Bulletin and -H Series Service Regulators 0 Elster American Meter The Series pressure regulators are designed to control natural gas, air, nitrogen, carbon dioxide,

More information