Calibration Certificate



Similar documents
Calibration Service Selection Guide

Estimates of Uncertainty of the Calibration of Balances

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

CCM.M-K3.1 comparison / 50 kg Mass

LAB14 EDITION 4 November 2006

Weight Calibration ComparatorPac TM Simple Calibration Efficient Workflow Reliable Results

GMP 11. Good Measurement Practice for Assignment and Adjustment of Calibration Intervals for Laboratory Standards

Process Measurement Assurance Program For U.S. State Metrology Laboratories 1

Measuring equipment in a laboratory.

User checks and maintenance of laboratory balances

IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS

Glassware Calibration Guidelines Laura B. Secor and Dwight R. Stoll, 02/01/2012 Adapted from National Bureau of Standards Document

THERMAL INSULATION MATERIALS

Certificate of Calibration No

OPERATIONAL STANDARD

How To Test A Titrette And Digital Burette

Accredited Laboratory

Procedure for Equipment Calibration and Maintenance


The Determination of Uncertainties in Charpy Impact Testing

calibrate confidence with Metrology Concepts: Understanding Test Uncertainty Ratio (TUR) Abstract Introduction White Paper

Laminar Flow Elements

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Calibration of Volumetric Glassware

Calibration & Preventative Maintenance. Sally Wolfgang Manager, Quality Operations Merck & Co., Inc.

Testing Your Laboratory Balance

Gravimetric determination of pipette errors

WEIGHTS AND MASS STANDARDS

Form and content of COOMET сertificate for reference materials for composition and properties of substances and materials

MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX AL-KHOBAR KINGDOM OF SAUDI ARABIA

CRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES

Eco Green Labs India Pvt. Ltd., Ground Floor, Plot No. 100, New Sidco Industrial Estate, Srinagar, Hosur, Tamil Nadu

Measuring instruments in industry.

Training Material for Balances (1) Prepared by R&D Division 1. Marketing Department A&D Company, Limited

Balance Calibration A Method for Assigning a Direct-Reading Uncertainty to an Electronic Balance

CMMs and PROFICIENCY TESTING

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

OIML R RECOMMENDATION. Edition 2004 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION , E 2. Weights of classes E 1 , F 2 , M 1 2 , M 1

To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used.

International Laboratory Accreditation Cooperation. Laboratory Accreditation or ISO 9001 Certification? global trust. Testing Calibration Inspection

3M CORPORATE METROLOGY SERVICES St. Paul, MN

Quality Assurance Manual January 2008 Revision I Revision date of 01/17/13. Pi Tape Corporation. 344 North Vinewood St. Escondido CA USA

Pipette Calibration. Accurate Pipettes Day by Day. Ensure Operational Reliability With Service XXL. For more information

Case study Realistic and best uncertainties with humidity instruments

Industrial Balances PREMIUM Series 490 IBK/ITK/ISK

American Association for Laboratory Accreditation

Laboratory Exercise: The Precision of Volume Measurements

Chapter 2 Measurements in Chemistry. Standard measuring device. Standard scale gram (g)

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

CRM s and the Dilemma of the 2nd Source. Shawn Kassner, Sr Product Manager Tim Miller, Sr Organic Chemist Phenova, A Phenomenex Company

ZA-12. Temperature - Liquidus + 45 o C (81 o C) Vacuum = 90mm

STANDARD OPERATING GUIDELINES: EVIDENTIAL BREATH ALCOHOL INSTRUMENT CALIBRATION

TEST REPORT for the ARID TECHNOLOGIES VAPOR RECOVERY UNIT installed in LANTANA, FL

S Davidson, M Perkin, M Buckley

CALIBRATION PRINCIPLES

Laboratory Metrology Education and Training. Georgia L. Harris NCSLI VP Learning and Development NIST Weights & Measures Division

When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.

EffiValidation 3.0 software basic training module

ISO17025 INTERPRETATION DOCUMENT FOR CEC TEST METHODS

MEASURING MACHINES. Pratt & Whitney METROLOGY LABORATORY. Measurement Systems, Inc.

Concept for an Algorithm Testing and Evaluation Program at NIST

Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-Type Viscometer 1

NIST HANDBOOK CHECKLIST CONSTRUCTION MATERIALS TESTING

1 For more information T: / E: DAP@ul.com / W: ul.com/dap

ASTM E 90: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements

ALACC Frequently Asked Questions (FAQs)

The Uncertainty of Reference Standards A Guide to Understanding Factors Impacting Uncertainty, Uncertainty Calculations, and Vendor Certifications

Handbook of Weighing Applications Balances and Scales Used as Measuring and Test Equipment in a Quality System

Microbalances MXA/ Microbalances MXA/F Analytical balances XA Analytical balances XA/X Analytical balances WAS/X...

NVLAP Assessor Training. Assessor Qualification & Training Requirements

VERIFYING CALIBRATION OF WEIGHING DEVICES USED FOR LABORATORY TESTING

Measurement and Calibration

Quality Assurance (QA) & Quality Control (QC)

ENERGY EFFICIENT LIGHTING PRODUCTS

Luminus Devices, Inc Luminus Testing Laboratory Quality Management Systems Manual

DENTAL CLINIC REMODEL for PORT GAMBLE S'KLALLAM TRIBE ADDENDUM #3

State Laboratory Program Workload Survey

Lab Service, Asset Management and Extending the Life of Your Lab Equipment. Scott Greenwood Director, Services

Method to Calculate Uncertainties in Measuring Shortwave Solar Irradiance Using Thermopile and Semiconductor Solar Radiometers

OPERATOR S MANUAL SUPPORTED TORQUE CALIBRATION BEAM. Part Number Issue 4 Original Instructions (English)

Vandal-proof keypad series

Hellma. Where precision becomes an art. Calibration standards for spectrophotometers by Hellma

SCHATZ - TEST Tool testing systems. SCHATZ -certest-w. Dynamic testing of torque tools

NIST HANDBOOK 150 CHECKLIST

ERRATUM: OIML R 60 RECOMMENDATION. Edition 2000 (E) ORGANISATION INTERNATIONALE ORGANIZATION INTERNATIONAL. Metrological regulation for load cells

ENERGY STAR Program Requirements Product Specification for Data Center Storage. Draft 2 Test Method March 2013

High-Precision Platforms

PRODUCT GUIDE PRECISION INSTRUMENTS FOR Temperature, Density, Time, Weather and Calibration

Viscosity - Flow Cups. elcometer.com

Determining Measurement Uncertainty for Dimensional Measurements

QUALITY MANAGEMENT IN VETERINARY TESTING LABORATORIES

Calibration. How can you get lower costs for the calibration? What is traceability? What is measurement uncertainty? What is calibration?

(Uncertainty) 2. How uncertain is your uncertainty budget?

User s Manual Laminar Flow Elements

Regulatory Requirements for Medical Device Calibration Programs

Procedure for Writing Technical Procedures

Transcription:

P.O. Box 87-0087 Phone:856-686-1600 Fax:856-686-1601 www.troemner.com e-mail: troemner@troemner.com SECTION 1: Page 1 of 7 Pages SECTION 2: APPROVED SIGNATORY Joseph Moran SECTION 3: PERSON PERFORMING WORK Katharine Ellison SECTION 4: CERTIFICATE INFORMATION Description of Masses: 5kg - 2mg Set Accuracy Class : ASTM E617-97* Class 1 Order : 123456 Construction : One Piece Material : Stainless Steel : Stainless Steel (mg) : Aluminum : 120402 Date Received Date of Calibration Date of Issue Range : 04-DEC-2003 : 08-DEC-2003 : 08-DEC-2003 : 5kg - 1g : 500mg - 50mg : 30mg - 2mg SECTION 5: ENVIRONMENTAL CONDITIONS DURING TEST Temperature: 21.00 o C Pressure: 760.00 mm Hg Relative Humidity: 43% SECTION 6: PERTINENT INFORMATION The s listed on this calibration report have been compared to reference mass standards that are directly traceable to the National Institute of Standards and Technology under Test No. 822/267283-02. Reference standards and balances used to perform the calibration are listed in Section 10. The weights calibrated for this report have been calibrated in accordance with Troemner's calibration process. The calibration performed meets Level I criteria as described in the NIST/NVLAP Technical Guide 150-2. This calibration also meets specifications as outlined in ISO 9001, ISO/IEC 17025, ANSI/NCSL Z540-1-1994, NCR Document 10CFR50 Appendix B, and applicable documents. This certificate of calibration shall not be reproduced except in full, without the written approval of Troemner LLC. This certificate of calibration must not be used by the customer to claim product endorsement by NIST, NVLAP or any agency of the U.S. government.

P.O. Box 87-0087 Phone:856-686-1600 Fax:856-686-1601 www.troemner.com e-mail: troemner@troemner.com Page 2 of 7 Pages SECTION 7: TRUE MASS (MASS IN VACUUM) CALIBRATION DATA ----------- True Mass ---------- As Found As Left Density 1 of Uncertainty 3000.0028 2000.0019 1000.00137 300.00047 200.00021 20.00002 10.00001 5.000002 3.000002 1.000000 0.499997 0.2999998 g 0.2000019 g 0.0999970 g 0.0500004 g 0.030000 0.01000 0.005000 0.0030027 g 0.0019999 g 3000.0028 2000.0019 1000.00137 300.00047 200.00021 20.00002 10.00001 5.000002 3.000002 1.000000 0.499997 0.2999998 g 0.2000019 g 0.0999970 g 0.0500004 g 0.030000 0.01000 0.005000 0.0030027 g 0.0019999 g 2.7000 g/cm 3 2.7000 g/cm 3 2.7000 g/cm 3 0. 0.19 mg 0.14 mg 0.040 mg 0.03 0.017 mg 0.0 0.004 mg 1 Density is assumed unless otherwise stated

P.O. Box 87-0087 Phone:856-686-1600 Fax:856-686-1601 www.troemner.com e-mail: troemner@troemner.com End User Page 3 of 7 Pages SECTION 8: MASS IN AIR CALIBRATION VALUE VS. REFERENCE DENSITY 8000 kg m -3 ---- Conventional ---- Uncertainty As Found As Left Tolerance 3000.0028 2000.0019 1000.00137 300.00047 200.00021 20.00002 10.00001 5.000022 3.000002 1.000000 0.4999966 g 0.299999 0.2000017 g 0.0999969 g 0.050000 0.030000 0.01000 0.005000 0.003002 0.001999 3000.0028 2000.0019 1000.00137 300.00047 200.00021 20.00002 10.00001 5.000022 3.000002 1.000000 0.4999966 g 0.299999 0.2000017 g 0.0999969 g 0.050000 0.030000 0.01000 0.005000 0.003002 0.001999 0. 0.19 mg 0.14 mg 0.040 mg 0.03 0.017 mg 0.0 0.004 mg 12.0000 mg 7.5000 mg 5.0000 mg 2.5000 mg 1.2000 mg 0.7 0.5000 mg 0.2 0.1 0.0

P.O. Box 87-0087 Phone:856-686-1600 Fax:856-686-1601 www.troemner.com e-mail: troemner@troemner.com Page 4 of 7 Pages SECTION 9: MASS IN AIR CALIBRATION DATA VS. REFERENCE DENSITY 8000 kg m -3 -- Conventional Mass Correction -- Uncertainty As Found As Left Tolerance 6.48 mg 2.8 1.9 1.37 0.677 mg 0.47 0.21 0.044 mg 0.059 mg 0.038 mg 0.021 mg 0.011 mg 0.022 0.002 0.0004 mg 0.000-0.0034 mg -0.0008 mg -0.0031 mg 0.000 0.0001 mg 0.00 0.000 0.0021 mg -0.0007 mg 6.48 mg 2.8 1.9 1.37 0.677 mg 0.47 0.21 0.044 mg 0.059 mg 0.038 mg 0.021 mg 0.011 mg 0.022 0.002 0.0004 mg 0.000-0.0034 mg -0.0008 mg -0.0031 mg 0.000 0.0001 mg 0.00 0.000 0.0021 mg -0.0007 mg 0. 0.19 mg 0.14 mg 0.040 mg 0.03 0.017 mg 0.0 0.004 mg 12.0000 mg 7.5000 mg 5.0000 mg 2.5000 mg 1.2000 mg 0.7 0.5000 mg 0.2 0.1 0.0

P.O. Box 87-0087 Phone:856-686-1600 Fax:856-686-1601 www.troemner.com e-mail: troemner@troemner.com Page 5 of 7 Pages SECTION 10: CALIBRATION PROCEDURE DATA Standard Set No. Cal Due Balance Used Cal Due Procedure Used PM5003-002 PM5003-002 PM5003-002 AT106-011 AT106-011 AT106-011 AT21-012 AT21-012

P.O. Box 87-0087 Phone:856-686-1600 Fax:856-686-1601 www.troemner.com e-mail: troemner@troemner.com Page 6 of 7 Pages SECTION 11: GENERAL INFORMATION This calibration was performed in Troemner s High Precision Level I Mass Metrology Laboratory at, Thorofare, New Jersey 08086 unless otherwise noted on page one. The internal procedures used are CAL-CLASSI, CAL-MMAP, and NIST HB145. SECTION 12: DEFINITIONS AND TERMS MASS IN A VACUUM - The mass of a weight as if it were measured in a vacuum. Also known as True Mass. MASS IN AIR - The conventional value of the result of weighing in air, in accordance to International Recommendation OIML R 33. For a weight taken at 20 ο C, the conventional mass is the mass of a reference weight of a density of 8000 kg m -3 which it balances in air of a density of 1. m -3. AS FOUND MASS IN A VACUUM - The measured value of the mass(es) as they were received by Troemner. If the customer requires cleaning prior to calibration, the after cleaning value would be reported. AS LEFT MASS IN A VACUUM - The measured value of the mass(es) after they were adjusted, repaired or replaced when necessary. The As Found Mass in a Vacuum will equal the As Left Mass in a Vacuum if the mass(es) did not require adjustment, repair or replacement. NOMINAL MASS - The mass value as marked on the weight. CORRECTION - The difference between the mass value of a weight and its nominal value. A positive correction indicates that the mass value is greater than the nominal value by the amount of the correction. AS FOUND CONVENTIONAL MASS CORRECTION - The conventional correction of the result, as it was received by Troemner, of weighing in air in accordance to International Recommendation R 33. For a weight taken at 20 ο C, the conventional mass is the mass of a reference weight of density 8000 kg m -3 which it balances in air density of 1. m -3. If the customer requires cleaning prior to calibration, the after cleaning correction would be reported. AS LEFT CONVENTIONAL MASS CORRECTION - The conventional correction of the result, after adjustment repair, or replacement of weighing in air in accordance to International Recommendation R 33. For a weight taken at 20 ο C, the conventional mass is the mass of a reference weight of density 8000 kg m -3 which it balances in air density of 1. m -3. The As Found will equal the As Left Conventional Mass Correction if the mass(es) did not require adjustment, repair or replacement. UNCERTAINTY - The error in assignment of the correction due to the measurement process. Uncertainty is calculated in accordance with UKAS document M3003 using a coverage factor of k = 2 (k = 2 defines an interval having a level of confidence of approximately 95 percent). The error does not include the effects of magnetism. (continued on next page)

P.O. Box 87-0087 Phone:856-686-1600 Fax:856-686-1601 www.troemner.com e-mail: troemner@troemner.com Page 7 of 7 Pages SECTION 12: DEFINITIONS AND TERMS (continued) TOLERANCE - Defines the limits in which the correction value & the uncertainty must fall to meet the tolerance specification for the given class. AS FOUND CONVENTIONAL MASS VALUE - The measured value of the mass(es) as they were received by Troemner, of weighing in air in accordance to International Recommendation R 33. For a weight taken at 20 ο C, the conventional mass is the mass of a reference weight of density 8000 kg m -3 which it balances in air density of 1. m -3. If the customer requires cleaning prior to calibration, the after cleaning value would be reported. F denotes Out of Tolerance. AS LEFT CONVENTIONAL MASS VALUE - The measured value of the mass(es) after they were adjusted, repaired or replaced when necessary, of weighing in air in accordance to International Recommendation R 33. For a weight taken at 20 ο C, the Conventional Mass is the mass of a reference weight of density 8000 kg m -3 which it balances in air density of 1. m -3. The As Found will equal the As Left Conventional if the mass(es) did not require adjustment, repair or replacement. ASTM E617-97* - s meet the tolerance specification for ASTM E617-97. s 2kg - 1g screened for magnetism using a Gaussmeter. SECTION 13: ADDENDUM No calibration due dates for standards provided