DENTAL CLINIC REMODEL for PORT GAMBLE S'KLALLAM TRIBE ADDENDUM #3
|
|
|
- Gilbert Flowers
- 9 years ago
- Views:
Transcription
1 To: All Planholders From: Tormod Hellwig, llc Addendum Date: 1 April 2016 DENTAL CLINIC REMODEL for PORT GAMBLE S'KLALLAM TRIBE ADDENDUM #3 This Addendum shall hereby be and become a part of the Contract Documents. The following clarifications, amendments, additions, revisions, changes, and modifications change the original Contract Documents only in the amount and to the extent hereinafter specified in this Addendum. All other terms, specifications, and conditions remain the same. The bidder is responsible for transmitting this information to all affected subcontractors and suppliers prior to the opening of bids. Bidder shall acknowledge receipt of this Addendum in his proposal or bid. CHANGES AND CLARIFICATIONS TO SPECIFICATIONS ITEM NO. 1: SECTION BID PROPOSAL Replace: the Bid Proposal Form with the one attached showing the correct time for completion. ITEM NO. 2: SECTION SUPPLEMENTARY GENERAL CONDITIONS ARTICLE 11 INSURANCE AND BONDS Add: Add to the following: Conditions for bonds: Payment and performance bonds for 100% of the Contract Award Amount shall be furnished for the Work, using the Payment Bond and Performance Bond form published by and available from the American Institute of Architects (AIA) form A312. Prior to execution of a Change Order that, cumulatively with previous Change Orders, increases the Contract Award Amount by 15% or more, the Contractor shall provide either new payment and performance bonds for the revised Contract Sum, or riders to the existing payment and performance bonds increasing the amount of the bonds. ITEM NO. 3: Add: SECTION EXISTING HAZARDOUS MATERIAL INFORMATION PART 1 - GENERAL 1.01 EXISTING HAZARDOUS MATERIAL INFORMATION A. This document with its referenced attachments is part of the Procurement and Contracting Requirements for Project. They provide Owner's information for Bidder's convenience and are intended to supplement rather than serve in lieu of Bidder's own investigations. They are made available for Bidder's convenience and information, but are not a warranty of existing conditions. This Document and its attachments are not part of the Contract Documents. ADDENDUM #3 Dental Clinic Remodel for Port Gamble S'Klallam Tribe Page 1
2 B. Investigations: 1. An Asbestos and lead Survey for the Dental Clinic was contracted by the Owner and was performed by Jose Technologies, PO Box 191, Keyport WA 98345, (360) The resultant study, dated March 30, 2016, consisting of 3 pages is attached. END OF SECTION ITEM NO. 4: SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS Delete: 3.3 FIELD QUALITY CONTROL 1. Air Infiltration: Areas shall be tested for air leakage of 1.5 times the rate specified for laboratory testing under Part 1 "Performance Requirements" Article, but not more than 0.09 cfm/sq. ft., of fixed wall area when tested according to ASTM E 783 at a minimum static-air-pressure difference of 6.24 lbf/sq. ft. 2. Water Penetration: Areas shall be tested according to ASTM E 1105 at a minimum uniform and cyclic static-air-pressure difference of 0.67 times the static-air-pressure difference specified for laboratory testing under Part 1 "Performance Requirements" Article, but not less than 4.18 lbf/sq. ft., and shall not evidence water penetration. B. Repair or remove work where test results and inspections indicate that it does not comply with specified requirements. C. Additional testing and inspecting, at Contractor's expense, will be performed to determine compliance of replaced or additional work with specified requirements. ITEM NO. 5: SECTION WALK-OFF CARPET Change: 2.1 CARPET: WM-1 To Read: 1. Shaw Carpet Group a. Style: portal tile: 5T035 b. Collection: All Access c. Color and pattern: As selected by Architect from manufacturer's full range d. Size: 24 x 24 e. Construction: Multi-level Pattern Loop f. Product Type: Tile g. Fiber: Eco Solution Q Nylon h. Backing: EcoWorks Tile i. Dye Method: 100% Solution Dyed j. Tufted Weigh: 28.0 CHANGES AND CLARIFICATIONS TO THE DRAWINGS ITEM NO. 5: SHEET A1.00 ADDENDUM #3 Dental Clinic Remodel for Port Gamble S'Klallam Tribe Page 2
3 Change: General Notes 3. Remove existing dental treatment chairs and reinstall after work is completed. To Read: 3. Owner will remove existing dental treatment chairs and disconnect attached medical gases and reinstall and reconnect after work is completed. ITEM NO. 6: SHEET A9.10 DETAIL 3 Change: Callout on handrail to read: 1 1/2 diam steel handrail. Prime and paint. SUBSTITUTION REQUESTS By Lighting Group Northwest SECTION Lighting Substitution: Fixture Type R1 Columbia Lighting: Approved. Fixture Type R2 Pathway Lighting: Not approved. Fixture Type SS Columbia Lighting: Approved. Fixture Type TP Tivoli: Not approved. Fixture Type UC Dals Lighting: Not approved. Fixture Type S1 Envoy Lighting: Nor approved. Fixture Type ST Lumenwerx: Not approved. Fixture Type X Dual-Lite: Approved. Fixture Type X1 Compass: Not approved. By Sea-Tac Lighting & Controls SECTION Lighting Substitution: Fixture Type R1 Pinnacle Lighting: Not approved. Fixture Type R2 Lightolier: Approved. Fixture Type SS Lamar Lighting: Not approved. Fixture Type TP Luminii: Not approved. Fixture Type UC Creative Systems: Not approved. Fixture Type S1 Daybrite Lighting: Approved. Fixture Type ST Precision Arch Lighting: Not approved. Fixture Type X Choride: Approved. Fixture Type X1 Chloride: Approved. END OF ADDENDUM #3 ADDENDUM #3 Dental Clinic Remodel for Port Gamble S'Klallam Tribe Page 3
4
5
6 Jose Technologies Joe Sparr March 30, Little Boston Road Kingston, WA Joe, Thank you again for contacting us. I was asked by Joe to do both an Asbestos and Lead test in the wing of the medical building at the Tribal Center on Little Boston Rd. I took one lead sample in the storage room midway through the clinic. This sample was to determine if there was any lead in the paint of the center. The sample was sent to the EMSL Labs in Seattle and their report is attached to this report. I also checked three different places for Asbestos in the tile floor and the ceiling tiles. The first floor sample was taken in the dental treatment, in the hall way ceiling tile and in the corner of the storage area in the center of the building. These three samples I also sent to the ESML lab in Seattle for analysis. I received the lab reports that I will attach and they show no asbestos or lead in the facility. With the different areas tested I am confident that the Dental Clinic is free of both Asbestos and Lead. If you have any questions please feel free to give me a call. Thank you again for calling us at Jose Tech Inspections. Sincerely, Paul Jose Jose Tech Inspection Services EPA R Certified Lead Paint Assessor Certified Mold Inspector NORMI # WA License # JOSETTI852B6 PO Box 191 Keyport WA
7 EMSL Analytical, Inc rd Ave S, Suite D 2nd floor Seattle, WA Tel/Fax: (206) / (206) / [email protected] EMSL Order: Customer ID: JTEC78 Customer PO: Project ID: Attention: Paul Jose Phone: (360) Jose Technologies Fax: PO Box 191 Received Date: 03/25/2016 1:45 PM Keyport, WA Analysis Date: 03/28/2016 Collected Date: 03/23/2016 Project: ; S'Klallam Dental Office; Little Boston, WA Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Non-Asbestos Sample Description Appearance % Fibrous % Non-Fibrous # #2-Vinyl Sheet Flooring #2-Mastic A #3-Vinyl Floor Tile #3-Mastic A Hallway to West Area - Ceiling Tile Area - Flooring Treatment Area - Flooring Treatment SE Storage - Flooring SE Storage - Flooring Tan Fibrous Gray Fibrous Yellow Non-Fibrous White Non-Fibrous Tan Non-Fibrous 50% Cellulose 30% Min. Wool 20% Non-fibrous (Other) 50% Glass 50% Non-fibrous (Other) 100% Non-fibrous (Other) 100% Non-fibrous (Other) 100% Non-fibrous (Other) Asbestos % Type Analyst(s) Cheuk-Wa Angela Ng (5) EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. Seattle, WA Initial Report From: 03/28/ :27:35 PLM Printed: 3/28/2016 1:27 PM Page 1 of 1
8 EMSL Analytical, Inc rd Ave S, Suite D 2nd floor, Seattle, WA Phone/Fax: / (206) [email protected] EMSL Order: CustomerID: CustomerPO: ProjectID: JTEC78 Attn: Paul Jose Jose Technologies PO Box 191 Keyport, WA Phone: (360) Fax: Received: 03/25/16 1:45 PM Collected: 3/23/2016 Project: ; S'Klallam Dental Office; Little Boston, WA Client Sample Description Test Report: Lead in Paint Chips by Flame AAS (SW B/7000B)* Lab ID Collected Site: Door Way Middle Store Desc: Paint Analyzed Lead Concentration # /23/2016 3/29/2016 < % wt or other approved signatory *Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise. Samples analyzed by EMSL Analytical, Inc. Seattle, WA Initial report from 03/29/ :41:17 Test Report ChmSnglePrm/nQC Printed: 3/29/ :41:17 PM Page 1 of 1
Asbestos Survey. for. Commercial Building TCA Building T-187, Pasco Airport Pasco, Washington. May 1, 2014. Project #A2014/0406.
Asbestos Survey for Commercial Building TCA Building T-187, Pasco Airport Pasco, Washington May 1, 2014 Project #A2014/0406 prepared for: Port of Pasco PO Box 769 Pasco, WA 99301 prepared by: Blue Mountain
ASBESTOS LABORATORY REPORT. Environmental Testing Services, Inc.
LABORATORY REPORT Prepared for PROJECT: 2614 Morganton Road Fayetteville, NC CEI LAB CODE: A14-10364 DATE ANALYZED: 07/30/14 DATE REPORTED: 07/30/14 TOTAL SAMPLES ANALYZED: 20 # SAMPLES >1 : 5 TEL: 866-481-1412
HART ENVIRONMENTAL RESOURCES
HART ENVIRONMENTAL RESOURCES 262 Hedge Dr. Springfield, OH 45504 (937) 325-8777 (937) 324-0288 FAX ASBESTOS INSPECTION REPORT 933 Xenia Ave. Dayton, Ohio 45410 PREPARED FOR: Mr. Dennis Zimmer Montgomery
6% Chrysotile NA 2 008 White floor tile 2 nd Floor 10,000 sq ft Cat 1 2% Chrysotile Poor
1.0 Asbestos Inspection Barge, Waggoner Summer & Cannon performed an asbestos survey for building 4666 (the Building) at the George C. Marshall Space Flight Center in Huntsville, Alabama on April 5, 2012.
1200 N. COLORADO WINSLOW, ARIZONA
ASBESTOS HAZORD EMERGENCY RESPONSE ACT (AHERA) INSPECTION & REPORT OF FIINGS FOR IUSTRIAL ARTS 1200 N. COLORADO WINSLOW, ARIZONA Submitted to: MR. RICHARD WILLIAMS BELFOR PROPERTY RESTORATION 23610 N.
Request for Proposals ASBESTOS ABATEMENT SERVICES. Coffeyville Community College 400 W. 11 th Street Coffeyville, KS 67337
Request for Proposals ASBESTOS ABATEMENT SERVICES Coffeyville Community College 400 W. 11 th Street Coffeyville, KS 67337 Date Issued: January 14, 2016 Date Due: February 5, 2016 at 2:00 pm, local time
PREPARED FOR: Branch Banking & Trust Environmental Risk Management 5130 Parkway Plaza Boulevard Charlotte, North Carolina 28217 (704) 954-1725
WATER INTRUSION AND VISUAL MOLD ASSESSMENT & LIMITED ASBESTOS-CONTAINING MATERIALS SURVEY FREDRICK WHITE 1119 DUSTIN STREET LADY LAKE, LAKE COUNTY, FLORIDA BB&T PROJECT NO. OMS-155500-REPORT #1 PREPARED
How To Perform A Limited Asbestos Survey
Limited Asbestos Survey Report Presented To: Barbara Wethington Project Manager Weston Solutions, Inc. 960 West Elliot Road, Suite 201 Tempe, Arizona 85284 Project: Southeast Corner of Arizona Highway
ASBESTOS BUILDING INSPECTION REPORT. for. Michigan State University Office of Environmental and Occupational Safety East Lansing, Michigan 48823
ASBESTOS BUILDING INSPECTION REPORT for Michigan State University Office of Environmental and Occupational Safety East Lansing, Michigan 48823 at Bailey Hall Building #315 East Lansing, Michigan 48823
SECTION 00100 NOTICE TO BIDDERS IVY TECH COLLEGE OF INDIANA NMC INFRASTRUCTURE IMPROVEMENTS INDIANAPOLIS, INDIANA
Ivy Tech Community College of Indiana, hereinafter referred to as the Owner, furnishes the following information and special instructions to prospective Bidders desiring to submit Bids for the Work on
Room ID------- Material ID ASBESTOS Components Positive? Yes, No, Trace, Assumed PISTM-1 White pipe insulation on hot water supply and return throughout building Yes 5-10% CH, 5-15%AM NA NA LF 1400 FLVCT-7
ASBESTOS INSPECTION REPORT
ASBESTOS INSPECTION REPORT F&R PROJECT NUMBER: 65R-3125 Regarding: Hwy 295 Baseball Park Score Tower Structure 2100 Southport Road Spartanburg, South Carolina Prepared for: Spartanburg County Parks Department
2013 AHERA 3 Year Re-Inspection Report For. Northeast Elementary School 82 Scofieldtown Road Stamford, CT. Performed by
2013 AHERA 3 Year Re-Inspection Report For 82 Scofieldtown Road Stamford, CT Performed by P.O. Box 423 Stratford, CT 06615 Inspection Date: April 17, 2013 82 Scofieldtown Road Stamford, CT I. EXECUTIVE
June 27, 2013. Project GSA1570019. Rhonda Rance U.S. General Services Administration 450 Golden Gate Avenue, Floor 4 San Francisco, California 94102
June 27, 2013 Project GSA1570019 Rhonda Rance U.S. General Services Administration 450 Golden Gate Avenue, Floor 4 San Francisco, California 94102 Subject: Determination of Asbestos Conditions Former USDA
AHERA 3-Year Asbestos Re-Inspection
AHERA 3-Year Asbestos Re-Inspection Denver 940 Fillmore Street Denver, Colorado 80206 Report Date: November 20, 2013 OEI Project No. 13.159 Prepared For: John Lewis Denver 940 Fillmore Street Denver, CO
OGS LIMITED ASBESTOS & LEAD SURVEY REPORT
our people and our passion in every project OGS LIMITED ASBESTOS & LEAD SURVEY REPORT Building 44 Willard Drug Treatment Center 7116 County Road 132 Willard, NY Prepared for: NYSOGS 33 rd Floor, Corning
SAN FRANCISCO UNIFIED SCHOOL DISTRICT 2011 PROPOSITION A BOND PROGRAM Paul Revere School Modernization and Interim Housing ADDENDUM NO.
SAN FRANCISCO UNIFIED SCHOOL DISTRICT 2011 PROPOSITION A BOND PROGRAM Paul Revere School Modernization and Interim Housing ADDENDUM NO. 1 PROJECT: Paul Revere School DATE: March 25, 2015 Modernization
SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
CATALOGUE OF ASBESTOS MATERIALS. City of White Rock White Rock Library 15342 Buena Vista Avenue White Rock, BC
Sterling IAQ Consultants Ltd. Suite 310-1122 Mainland Street Vancouver, B.C., V6B 5L1 (t) 604.681.2701 (f) 604.681.2702 www.sterlingiaqconsultants.com CATALOGUE OF ASBESTOS MATERIALS City of White Rock
May 23, 2014. Mr. Derek Sandgren Helm Properties 1520 Butte House Road, Suite 400 Yuba City, California 95993-2240
May 23, 2014 Mr. Derek Sandgren Helm Properties 1520 Butte House Road, Suite 400 Yuba City, California 95993-2240 RE: Pre-Demolition Asbestos Survey Report 6150 Farrell Street, Marysville, California 95901
TruexCullins Architecture Fairfield Center School Bid Documents Kitchen and Bathroom Renovation March 1, 2015
Fairfield Center School Kitchen and Bathroom Renovation Project Specifications Owner: Fairfield Center School, 57 Park Street, Fairfield VT 05455 Franklin Central Supervisory Union, 28 Catherine Street,
Asbestos Survey Former Kraft General Foods Facility 500 Dalton Avenue and 1222 Statesville Avenue Charlotte, North Carolina. H&H Job No.
Asbestos Survey Former Kraft General Foods Facility 500 Dalton Avenue and 1222 Statesville Avenue Charlotte, North Carolina H&H Job No. CLT-204 August 13, 2009 2923 South Tryon Street Suite 100 Charlotte,
DEMOLITION INSPECTION REPORT ASBESTOS CONTAINING MATERIALS
DEMOLITION INSPECTION REPORT ASBESTOS CONTAINING MATERIALS Property Address: The Verandas @ Rocky Ridge 3741 Chesnut Ridge Inspection ordered by: Cotton Commercial USA 5443 Katy Hockley Cutoff Rd. Katy,
PRE-DEMOLITION ASBESTOS SURVEY
PRE-DEMOLITION ASBESTOS SURVEY For: City of Largo PSTA Building 14840 49th Street North Largo, Pinellas County, Florida Prepared for: Collman & Karsky Architects 4301 Anchor Plaza Parkway, Suite 100 Tampa,
INVITATION FOR BIDS CCK-2139-16 PROJECT 2369.2 PEDIATRIC CRITICAL CARE RENOVATION PHASE 3 ADDENDUM #3 6-22-16
INVITATION FOR BIDS CCK-2139-16 PROJECT 2369.2 PEDIATRIC CRITICAL CARE RENOVATION PHASE 3 ADDENDUM #3 6-22-16 ATTENTION: This is not an order. Read all instructions, terms and conditions carefully. IMPORTANT:
Calibration Certificate
P.O. Box 87-0087 Phone:856-686-1600 Fax:856-686-1601 www.troemner.com e-mail: [email protected] SECTION 1: Page 1 of 7 Pages SECTION 2: APPROVED SIGNATORY Joseph Moran SECTION 3: PERSON PERFORMING
EXHIBIT A SCOPE OF SERVICES
EXHIBIT A SCOPE OF SERVICES 1.0 INTRODUCTION Asbestos consulting services are required for Item/Segment No. 227775-1, SR-7 (US 441) from Fillmore Street to South of Stirling Road, Hollywood, Broward County,
ASBESTOS and LEAD-BASED PAINT INVESTIGATION TOWN OF ST. PAUL WILLIS BUILDING ST. PAUL, VIRGINIA
ASBESTOS and LEAD-BASED PAINT INVESTIGATION TOWN OF ST. PAUL WILLIS BUILDING ST. PAUL, VIRGINIA May 22, 2013 Robert R. Jones, Ph.D., REM, AHERA Asbestos Inspector, 5/22/13 Signature Date Asbestos Virginia
January 23, 2009 Reference No. 055643
1412 Oakbrook Drive, Suite #180. Norcross, GA 30093 Telephone: (770) 441-0027 Fax: (770) 441-2050 www.craworld.com January 23, 2009 Reference No. 055643 Chief Deputy Stan Copland Douglas County Sheriffs
From the Office of: MAHLUM ARCHITECTS 71 Columbia Street Floor 4 Seattle, WA 98104
MAHLUM SECTION 00 91 11 ADDENDUM No.1 Date: June 15, 2012 From the Office of: MAHLUM ARCHITECTS 71 Columbia Street Floor 4 Seattle, WA 98104 NOTICE TO ALL CONTRACTORS, SUBCONTRACTORS, AND SUPPLIERS This
POTENTIALLY HAZARDOUS MATERIALS BUILDING INSPECTION REPORT. for
POTENTIALLY HAZARDOUS MATERIALS BUILDING INSPECTION REPORT for Michigan State University Engineering and Architectural Services Physical Plant Building, Room 101 East Lansing, Michigan 48824-1326 at Michigan
All other provisions of the contract documents, plans and specifications shall remain unchanged.
B. Supplementary Conditions a. Reference Page CS-5, Section 11.0 Insurance, Section C3.3-11 Insurance Item c.7: Delete paragraph and replace with the following: Environmental Impairment Liability Coverage
Invitation to Bid and Instructions to Bidders (This is Phase I of the project please note on any Bid that it Applies to Phase I only) May 1, 2015
Invitation to Bid and Instructions to Bidders (This is Phase I of the project please note on any Bid that it Applies to Phase I only) May 1, 2015 For PROJECT : Renovation and Repair of Atlanta Jewish Academy
ASBESTOS IN SETTLED DUST: A BRIEF REVIEW
ASBESTOS IN SETTLED DUST: A BRIEF REVIEW Background: Federal, State, and local asbestos regulations have established criteria for worker exposures, building occupancy, clearance levels, bulk sampling and
APPLICATION & RULES FOR OWNERS, CONTRACTORS, MOVERS
THE STRATFORD AT PELICAN BAY CONDOMINIUM ASSOCIATION, INC. Remodeling, Renovating, Altering, Repairing and Moving APPLICATION & RULES FOR OWNERS, CONTRACTORS, MOVERS 5601 TURTLE BAY DR. NAPLES, FL 34108
RECRUITMENT LETTER. To be included on our current bidders list, please fill in the Contractor Qualification Registration, which includes:
CITY OF BRUNSWICK Department of Community Development 601 Gloucester Street * Post Office Box 550 * Brunswick * Georgia * 31520-0550 * (912) 267-5530 * Fax (912) 267-5542 Cornell L. Harvey, Mayor Felicia
All bidders shall indicate in their bid/proposal that this Addendum has been received and considered in their bid proposal.
Addendum #1 Fire Damage Repairs 4316 City View Terrace, Units A and B City View Terrace, OH5-13C, AMP 4 IFB #14-03 October 23, 2014 Greater Dayton Premier Management 400 Wayne Ave. Dayton, Ohio 45410 This
Saxe Middle School Auditorium Renovation February 4, 2015
Saxe Middle School Auditorium Renovation February 4, 2015 OVERVIEW OF PRESENTATION Renovation of Saxe Auditorium State & Federal Testing requirements Town Hires Tighe & Bond to perform testing Summary
Asbestos Management POLICY
Asbestos Management POLICY All Asbestos Containment Material (ACM) removal activities shall comply with applicable federal, state, and local regulations. Areas of responsibility of Facilities Management
Asbestos Survey Form (See Instructions)
Asbestos Survey Form (See Instructions) 777 12th Street, 3rd Floor Sacramento, CA 95814 Office (916) 874-4800 Fax (916) 874-4899 Email: [email protected] 1. Purpose of Survey Renovation Demolition
ASBESTOS BUILDING INSPECTION
ASBESTOS BUILDING INSPECTION LOCATION: LIBRARY EAST 1825 SW BROADWAY PORTLA, OREGON 97201 JUNE 23, 2008 FORENSIC ANALYTICAL PROJECT NO. PJ5592 PREPARED FOR: PORTLA STATE UNIVERSITY PO BOX 13175 PORTLA,
ASBESTOS BUILDING INSPECTION REPORT. for the. City of East Lansing Waste Water Treatment Plant East Lansing, Michigan 48823.
ASBESTOS BUILDING INSPECTION REPORT for the City of East Lansing Waste Water Treatment Plant East Lansing, Michigan 48823 at the City of East Lansing Waste Water Treatment Plant and Woodingham Pump Station
November 9, 2015. Wake County Public Schools Department of Environmental Health & Safety 1551 Rock Quarry Road Raleigh, NC 27610.
November 9, 2015 Wake County Public Schools Department of Environmental Health & Safety 1551 Rock Quarry Road Raleigh, NC 27610 Attention: Subject: Mr. Donald Davis Limited Indoor Air Quality Investigation
ADDENDUM No. 2. RFP No. 14-15/27, Oakland Maintenance Center Facility Management Services
Purchasing Department 530 Water Street Oakland, CA 94607 March 6, 2015 ADDENDUM No. 2 RFP No. 14-15/27, Oakland Maintenance Center Facility Management Services This Addendum modifies the original RFP Documents
Approved by: UBC ACT Committee
The University of British Columbia Asbestos Safety Policy Prepared by: Russell R. English Policy Approved by: UBC ACT Committee Issue Date: April 1, 2004 Replaces: March, 1989 I-B-05 1.0 Policy: This policy
ARTICLE 11. INSURANCE AND BONDS
Provide submittals to Architect / Engineer that are required by any governing body or other authorities. Upon receipt of the Contractor s list, the Architect will make an inspection to determine whether
Document A101. Standard Form of Agreement Between Owner and Contractor where the basis of
TM Document A101 2007 Instructions Standard Form of Agreement Between Owner and Contractor where the basis of payment is a Stipulated Sum GENERAL INFORMATION Purpose. AIA Document A101 2007 is intended
Asbestos Procedures. Asbestos Products
Asbestos Procedures Asbestos Products Where is asbestos known to be located on The Evergreen State College? Please see Appendix A for a list of known asbestos containing materials located on the Olympia
WOOD DESTROYING PESTS AND ORGANISMS INSPECTION REPORT
` WOOD DESTROYING PESTS AND ORGANISMS INSPECTION REPORT Building No. Street City Zip Date of Inspection Number of Pages 1728 AVENIDA ELISA SAN JOSE 95131 1/5/2012 5 125 SOUTH CAPITOL AVENUE SAN JOSE, CA
YOU VE BEEN HIRED AS A GENERAL CONTRACTOR
CONSTRUCTION LOAN PROCEDURES 1-800-589-8850 WWW.FIRSTFEDLORAIN.COM YOU VE BEEN HIRED AS A GENERAL CONTRACTOR FIRST FEDERAL SAVINGS AND LOAN ASSOCIATION OF LORAIN YOUR COMMUNITY BANK SINCE 1921 Toll Free
REQUEST FOR PROPOSALS (RFP) For: Water Damage Repairs 1495 N. Tucker Ridge Rd. Okeechobee, FL 34974
REQUEST FOR PROPOSALS (RFP) For: Water Damage Repairs 1495 N. Tucker Ridge Rd. Okeechobee, FL 34974 RFP # STOFBR111715-1 Proposal Deadline Tuesday 11/30/2015 REQUEST FOR PROPOSALS PRE-BID Thursday 11/19/2015
NOTICE TO CONTRACTORS
NOTICE TO CONTRACTORS Notice is hereby given that San Luis Obispo County Community College District, ( District ) is accepting sealed Informal Bidding Prequalification Applications and Formal Bidding Prequalification
NDSU TABLE OF CONTENTS
NDSU TABLE OF CONTENTS 1.0 INTRODUCTION 2.0 DEFINITIONS AND DESCRIPTIONS 3.0 OPERATIONS AND MAINTENANCE PROCEDURES FOR ACM 4.0 FIBER RELEASE EPISODES 5.0 DEMOLITION INFORMATION 6.0 REMARKS 1.0 INTRODUCTION
NARRATIVE REPORT. The Asbestos Bulk Sample Results Table includes asbestos sampling data.
NARRATIVE REPORT 1.0 BUILDING INFORMATION The original date of construction for Construction Management Engineering was not immediately available; the building has had no major renovations. Construction
SUMMARY OF ASBESTOS CONTAINING MATERIAL IN BUILDINGS AND BULK SAMPLE ANALYSIS
ASBESTOS SURVEY SUMMARY PACIFIC UNION COLLEGE ANGWIN, CALIFORNIA SUMMARY OF ASBESTOS CONTAINING MATERIAL IN BUILDINGS AND BULK SAMPLE ANALYSIS Definition of terms: Friable: Material that can be crumbled
ASBESTOS INSPECTION REPORT 2 Delaware Street, 38 and 39 North Henry Court South Burlington, VT 05403 AIP 84
ASBESTOS INSPECTION REPORT 2 Delaware Street, 38 and 39 North Henry Court South Burlington, VT 05403 AIP 84 December 16, 2011 Revised January 31, 2012 KAS PROJECT # 509110228 PREPARED FOR: Stantec, Inc.
HOMER TOWNSHIP HIGHWAY DEPARTMENT ADDENDUM #1. June 13, 2014 VARIOUS (2014 ROAD PROGRAM) SECTION NO.: 14-00000-01-GM
HOMER TOWNSHIP HIGHWAY DEPARTMENT ADDENDUM #1 June 13, 2014 VARIOUS (2014 ROAD PROGRAM) SECTION NO.: 14-00000-01-GM This addendum consists of the following clarification: 1. Addendum #1 is attached and
CITY OF BELL PROFESSIONAL CONSULTING SERVICES FOR ROOF REPAIRS TO CITY OWNED FACILITIES
CITY OF BELL 6330 PINE AVENUE BELL, CA 90201 PH: (323) 588-6211 FAX: (323) 771-9473 CITY OF BELL PROFESSIONAL CONSULTING SERVICES FOR ROOF REPAIRS TO CITY OWNED FACILITIES I. INTRODUCTION City of Bell
AIA Document A141 TM - 2004 Standard From of Agreement Between Owner and Design- Builder
AIA Document A141 TM - 2004 Standard From of Agreement Between Owner and Design- Builder AGREEMENT made as of the day of in the year of (In words, indicate day, month and year) BETWEEN the Owner: (Name,
Safeway 691 Berkeley. 1444 Shattuck Place Date: May 3, 2007 MDA. Store Data: Interior Construction Materials: Exterior Construction Materials:
Safeway 691 Berkeley Preliminary Draft Environmental Survey for Renovation Store Data: Total Area: 26,327 Sq. Ft. at main level ACM 12x12: 17,600 Sq. Ft. Approx. Est. Vinyl Sheet: NA Other: See Table 1444
State Water Resources Control Board Environmental Laboratory Accreditation Program
State Water Resources Control Board Environmental Laboratory Accreditation Program P.O. Box 100, Floor 24 850 Marina Bay Parkway, Build. P 500 N Central Ave, Suite 500 Sacramento, CA 95812-0100 Richmond,
Restoration Specific Asbestos and Lead Based Paint Survey Report. 2503 Logan Ave Colorado Springs, CO 80909
Restoration Specific Asbestos and Lead Based Paint Survey Report Property Information: 2503 Logan Ave Colorado Springs, CO 80909 Inspection Conducted By: Shannon Anderson Colorado Cert #14225 Ted Anderson
510 Madera Ave San Jose, CA 95112 (408) 993-1900 Fax (408) 993-1944
HomeGuard 510 Madera Ave San Jose, CA 95112 (408) 993-1900 Fax (408) 993-1944 Dear HomeGuard customer, Thank you for selecting HomeGuard to perform the termite inspection on your home. It is very common
AHERA ASBESTOS REINSPECTION
AHERA ASBESTOS REINSPECTION 200 S. Fruitland kennewick, Washington Prepared For: Kennewick School District Prepared By: 320 North Johnson Street, Suite 700 Kennewick, Washington 99336 August 2013 Project
The Truth About Asbestos In Your Home
The Truth About Asbestos In Your Home A Complete Report For Anyone Starting A Home Repair Or Remodeling Project In this report you will find out: What asbestos is. What the dangers are of being exposed
REQUEST FOR QUOTES (RFQ)
REQUEST FOR QUOTES (RFQ) Lincoln County Public Works is requesting quotes (RFQ) through its Small Works Roster Process. Quotes are being requested for a project to replace the roof on the Crew Headquarters/Truck
ADDENDUM 5 TO IFB 5212-BC UNLV UCC DORMITORY COMPLEX HUGHES AND FAIMAN HALLS HVAC AND ROOFING REPLACEMENT. University of Nevada, Las Vegas
ADDENDUM 5 TO IFB 5212-BC UNLV UCC DORMITORY COMPLEX HUGHES AND FAIMAN HALLS HVAC AND ROOFING REPLACEMENT University of Nevada, Las Vegas Purchasing Department 4505 Maryland Parkway Las Vegas, Nevada 89154-1033
Request for Qualifications 2015-162
Kitsap County Human Services Department Request for Qualifications 2015-162 Architectural and Project Management Services - Kitsap County Work Release Facility Remodel Response Deadline: November 17, 2015
Airborne asbestos is a serious health hazard.
A Homeowner s Guide What is asbestos? Asbestos is a naturally occurring mineral fiber that has been used in more than 3,000 different construction materials and manufactured products. It is commonly found
CARITAS MANAGEMENT CORPORATION CALIFORNIA ADDENDUM GENERAL
This TO THE RESIDENTIAL LEASE AGREEMENT (the "CA Addendum") modifies the ial Lease Agreement ("Lease") dated the same date as this CA Addendum for the rental unit # located at ("Premises") and is made
ASBESTOS/LEAD SURVEY AND CONSULTING AGREEMENT BY AND BETWEEN NEW YORK UNIVERSITY / NYU HOSPITALS CENTER - OWNER - AND - CONSULTANT - --------- PROJECT
APPENDIX A ASBESTOS/LEAD SURVEY AND CONSULTING AGREEMENT BY AND BETWEEN NEW YORK UNIVERSITY / NYU HOSPITALS CENTER - OWNER - AND - CONSULTANT - --------- PROJECT DATED AS OF ASBESTOS/LEAD SURVEY AND CONSULTING
Solicitation Addendum One (1) RFQ 09-07 CARPET CLEANING SERVICES
Solicitation Addendum One (1) RFQ 09-07 6829 North 58th Drive, Suite 202 Glendale, Arizona 85301-2599 A signed copy of this Addendum must be received by on or before the Offer Due Date and time. This solicitation
THIS ADDENDUM MUST BE ACKNOWLEDGED. THIS ADDENDUM SHALL BECOME A PART OF THIS SOLICITATION. Amend Invitation to Bid 14-MC-2194 as follows:
Denver Public Schools Purchasing Department 1617 S. Acoma St. Denver, Colorado 80223 INVITATION TO BID 14-MC-2194 ADDENDUM NUMBER ONE January 24, 2014 THIS ADDENDUM MUST BE ACKNOWLEDGED. THIS ADDENDUM
Photo 1: This photograph shows drywall, joint compound, cove base mastic, carpet adhesive, and ceiling tile in store front No. 1.
APPENDIX B PHOTOLOG Photo 1: This photograph shows drywall, joint compound, cove base mastic, carpet adhesive, and ceiling tile in store front No. 1. Photo 2: This photograph shows layered floor tile and
SECTION 02 8213 ASBESTOS ABATEMENT
PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 specification sections shall apply to work of this section.
City of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
UNVERSITY HIGH SCHOOL U0018 65-108-9010-0001 500 W. Gregory St. Normal, IL 61761. School Asbestos Management Plan. Supplemental.
UNVERSITY HIGH SCHOOL U0018 65-108-9010-0001 500 W. Gregory St. Normal, IL 61761 School Asbestos Management Plan Supplemental Prepared By: David Martin Management Planner Environmental Health and Safety
Dear Contractor: If you have any questions about the Program or your Application, please feel free to call our office at 753-8292.
Housing Authority of Thurston County 1206 12th Avenue SE Olympia, WA. 98501 Tel: (360) 753-8292 Fax: (360) 586-0038 www.hatc.org Dear Contractor: Thank you for your interest in the Housing Rehabilitation