Tall Buildings and the Urban Microclimate in the City of London



Similar documents
Assessment of Solar Access in different urban space configurations in two southern latitude cities with mild climates.

Urban Environment: constraints and opportunities towards a sustainable quality

3. Shading. V. ENVIRONMENTAL IMPACT ANALYSIS A.3 Aesthetics Shading

DESIGN OF NATURAL VENTILATION WITH CFD CHAPTER SEVEN. Qingyan Chen. difficult to understand and model, even for simple

Optimum Solar Orientation: Miami, Florida

Urban Climatic Map of Arnhem City

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

28.0 Development Permit Area #2 (Neighbourhood District)

Guidance on Householder permitted development rights

Cool Spaces. earth-wise guide to. green strategies: light strategies: Keep Austin Cool

LATITUDES INTERNATIONAL DESIGN CHALLENGE

Perspective-Dependent Color-Changing Roofing Sheets

Adaptive strategies for office spaces in the UK climate

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

DEPLOSUN REFLECTORS. Carrer dels Vergós, Barcelona Spain Tel: (+34) Fx: (+34)

Seasonal & Daily Temperatures. Seasons & Sun's Distance. Solstice & Equinox. Seasons & Solar Intensity

Elegance SC. Solar Control

Millennium Quarter Public Realm Guidance Manual 2008

Seasonal Temperature Variations

Alternatives and Design Evolution: Planning Application 1 - RBKC

Miami Science Museum DoE Modelling Grant. Light Planning. 19 December 2008 Concept Design

K M D Hire Services, LONDON ROAD, NANTWICH, CW5 6LU

Weather perception in urban public spaces: Soho Square, London, case study

Net Zero Station Design for The Cooper Centre for the Environmental Learning in Tucson, Arizona: Improving the performance of existing buildings

CHAPTER 3. The sun and the seasons. Locating the position of the sun

PROPOSAL Stalker Hall Sunwork and Garden A large outdoor sculpture and garden space

klimatanpassad urban design Erik Johansson Boende och Bostadsutveckling

5.14 COMPUTATIONAL MODELLING OF AIRFLOW IN URBAN STREET CANYON AND COMPARISON WITH MEASUREMENTS

Energy efficient home design

Guidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012)

The Zig Zag Building Victoria Street, London, SW1

Opening the Bonnet. Prof Darren Woolf WYSINWYG 1

Full credit for this chapter to Prof. Leonard Bachman of the University of Houston

Name Period 4 th Six Weeks Notes 2015 Weather

4 Alternatives and Design Evolution

Chapter Overview. Seasons. Earth s Seasons. Distribution of Solar Energy. Solar Energy on Earth. CHAPTER 6 Air-Sea Interaction

05 AREA/SITE SPECIFIC GUIDELINES

Course Curriculum for Master Degree in Architecture

Planning should achieve high quality urban design and architecture that: Contributes positively to local urban character and sense of place.

RESSÒ: energy efficiency urban rehabilitation

CITY COUNCIL PACKET MEMORANDUM

urban living and contributes positively to the character of

Academic Study Plan 1991

Geography affects climate.

ANALYSIS OF THE THERMOPHISIOLOGICALLY SIGNIFICANT CONDITIONS WITHIN A MEDIUM-SIZED CITY WITH CONTINENTAL CLIMATE (SZEGED, HUNGARY)

Solar Heating Basics Page 1. a lot on the shape, colour, and texture of the surrounding

Effect of High-albedo Materials on Pedestrian Thermal Sensation in Urban Street Canyons in Hot Climates

APPLICATION OF DATA MINING TECHNIQUES FOR BUILDING SIMULATION PERFORMANCE PREDICTION ANALYSIS.

Each icon on this map represents the physical location of a station.

K M D Hire Services, LONDON ROAD, NANTWICH, CW5 6LU

FOR SALE. The Friedman Building th Avenue South, Seattle Nicholas T. Gill Allan Friedman

Lighting and Ventilation Requirements Performance-based Approach

Solar Flux and Flux Density. Lecture 3: Global Energy Cycle. Solar Energy Incident On the Earth. Solar Flux Density Reaching Earth

CH 2. green building design. Design snap shot 11: Biomimicry. Setting a new world standard in. Summary

ENERGY SAVING WINDOW FILMS S LAR CONTROL

Arizona State University. Understanding the Impact of Urban Heat Island in Phoenix

Aztech Architecture Your Guide to Overshadowing, Daylight & Sunlight. 1 P age

The following words and their definitions should be addressed before completion of the reading:

Planning of the Pre-Concept Architectural Design For the McGill University Health Centre, Montreal

Environment and Urbanization

MacroFlo Opening Types User Guide <Virtual Environment> 6.0

3-D Modeller Rendered Visualisations

Rufus Block 19. Project # DRB Recommendation Meeting #1 May 21, 2013

4.6. ECOCITY Tübingen - Derendingen

Air Conditioning, Comfort and Energy in India s Commercial Building Sector

GIS-Based and computer simulation evaluation on. campus master plan

ATM S 111, Global Warming: Understanding the Forecast

New Waterloo. Transforming the Elizabeth House site

DEVELOPMENT BRIEF FOR LAND AT ALLOA ROAD, TULLIBODY

Energy savings in the residential area are essential in

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Site Development Information Worksheet for single family residential development

SolCAD: 3D Spatial Design Tool Tool to Generate Solar Envelope

DISCOVERY HALL, UNIVERSITY OF WASHINGTON BOTHELL Bothell, Washington 78,200 sf

WELCOME PROPOSALS FOR PENTAVIA RETAIL PARK WELCOME TO OUR EXHIBITION WHICH SETS OUT OUR PLANS TO DEVELOP THE PENTAVIA RETAIL PARK SITE.

Design and Access Statement Earls Court Road London SW5 9RH

Development of empirical models for an estate level air temperature prediction in Singapore

Protocol for the Certification of Energy Simulation Software: First edition, December 2009

23.1 RENEWABLE ENERGY

Green BIM/ Early BIM/

Building skin and energy efficiency in a hot climate with particular reference to Dubai, UAE

Appendix "B" - Development Checklist

APPLYING CFD TO ENVIRONMENTAL FLOWS

Protocol for the Certification of Energy Simulation Software: Second edition, September 2011

CHAPTER 5 Lectures 10 & 11 Air Temperature and Air Temperature Cycles

City of Cambridge Climate Protection Action Committee. Recommendation to the City Manager on Urban Heat Island Mitigation

The Economics of Building Tall. James Barton 29 th May 2014

redland house, bristol - public consultation exhibition

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

Time of Year - Based onMeasurement by NASA

Which month has larger and smaller day time?

Design and Re-Use Of Shovadans In Today's Architecture "With Due Attention To Have Thermal Energy Of The Earth"

21 Plumbers Row, London, E1 1EQ

WELCOME NEW PLANS FOR. HERTSMERE HOUSE ALL IMAGES ARE INDICATIVE ONLY LOCATION ABOUT GREENLAND GROUP SITE LOCATION

Welcome to our exhibition

Residential Windows, 3 rd edition Corrected index 1

Minister s Guideline MG-12 Siting and Design of Single Dwellings

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, , ]

LIFE SCIENCE. Hoop House Construction for New Mexico: 12-ft. x 40-ft. Hoop House BRINGING TO YOUR HOME ECONOMICS COLLEGE OF AGRICULTURE AND

PHSC 3033: Meteorology Seasons

Transcription:

Tall Buildings and the Urban Microclimate in the City of London Sujal V. Pandya, B. Arch., M. Sc, COA Low Energy Architecture Research Unit London Metropolitan University, United Kingdom Luisa Brotas, Arch, PhD, ARB, RIBA Low Energy Architecture Research Unit, Sir John Cass, Faculty of Art, Architecture and Design, London Metropolitan University, United Kingdom l.brotas@londonmet.ac.uk ABSTRACT The design of tall buildings can be quite complex not only in architectural, structural or façade system terms but also in their interrelations with the environment. Recent design developments have shown a growing consideration for this micro-climate interface as a part of a sustainable design strategy for tall buildings towards bioclimatic urban fabrics. Architects and urban planners recognize that the importance of activities at street level is a constant reality. Many efforts are made to develop sustainable skyscrapers where the co-relation with the surrounding environment influences the architecture, land use pattern, public realm and street activities. The aim of this study is to understand the environmental or bioclimatic factors, which take part in the creation of microclimate relations between tall buildings and the urban city fabric. The research includes a brief understanding of bioclimatic design of tall building focusing in its relation to surrounding neighbourhoods. The impact of environmental factors namely wind flow patterns around buildings, daylight availability and overshadowing, air temperature and humidity, as well as the urban heat island phenomena, landscape and albedo of materials, vehicular & pedestrian movements and activity patterns at street levels in tall building clusters is addressed. A series of environmental variables measured during summer and simulated results of Canary Wharf and Liverpool Street clusters are compared to understand how the urban microclimates are affected within two different urban fabric typologies in London. Outcomes of literature review and these two case studies give useful guidelines to be utilized in the process of Sustainable urban design. ITRODUCTIO Cities all around the world are recognized by their skylines (Figure 1) and there are many drivers to its growth. Land scarcity and high real estate value, commercial opportunities and corporate demand, as well as the attraction to the cluster are often allied with a growing city population and its social needs.. Figure 1 Canary Wharf skyline, London. Sujal V. Pandya is a Visiting Researcher at the Low Energy Architecture Research Unit at London Metropolitan University. Dr Luisa Brotas is Course Leader of the MSc Architecture Energy and Sustainability and co-director of the Low Energy Architecture Research Unit at the Sir John Cass Faculty of Art, Architecture and Design at London Metropolitan University, London, United Kingdom. 30th ITERATIOAL PLEA COFERECE 1

The City of London is a world financial centre and needs to project an image of power and efficiency. The scarcity of land within the neighbourhood is further restricted by a surrounding mesh of residential buildings, on average with less than 3 floors (London has around 52% dwelling of the type terraced, semi detached and detached). High rise buildings being structures with 12 floors minimum contrast significantly with the low height London residential stock. According to the England housing survey, London only has 20% of dwellings that are 3 or more storeys in height. (EHS, 2012) This contrast with high-rise clusters developed within the city and in particular in the city of London neighbourhood (Canary Wharf Tower is 235m height). Tall buildings in a cluster are a growing tendency as a solution to the need of office space within the limited land available. The Greater London Authority promotes this concept as an efficient way to build offices that need to be energy efficient and with good public transport access and capacity, in line with sustainable cities and the Agenda 21. (GLA, 2014) This creates an opportunity for sustainable development in a holistic approach that goes beyond the architecture, structural or façade system to include the interface between the street environment and the building. Recent design developments have shown major consideration over this microclimate interface as a part of a sustainable design strategy for tall buildings in the direction of making bioclimatic urban fabrics. Likewise local climate variations influence the urban boundary and should be given much thought. The amount of solar radiation can be significantly reduced in urban areas as a result of overshadowing, air pollutants and wind flow patterns adding to the greenhouse effect. The Urban Heat Island phenomenon can be aggravated by high-density materials, surfaces with low albedo, reduced green spaces (evapotranspiration) and anthropogenic heat. This impacts the surface and air temperatures near the ground. Conversely high-rise buildings require special attention to the effect of strong winds at high levels. At street level wind may be much reduced overall (though it may increase locally due to a wind tunnel effect) and buildings casting shadows may create dark and cold spots for pedestrians. The character of the urban cluster / fabric play a big role in such microclimates. (Littlefair, 2000; Erell, 2011) BIOCLIMATIC DESIG COSIDERATIOS FOR URBA FABRICS WITH TALL BUILDIGS The effect of climate on the activities of occupants and its health is the base of Bioclimatology. The bioclimatic design approach is not limited to the building but extends beyond and involves external environmental conditions, site location, geography, surrounding buildings and their aesthetic expressions, land use pattern, the neighbourhood cluster, public accessibility and activities. (Clair, 2010) The major bioclimatic design considerations for high-rise clusters are: a. Urban geometry (Figure 2): variation in heights and in-between distances of buildings (street canyon); b. Local climate: external air temperature, relative humidity and prevailing wind direction and speed; c. Orientation and overshadowing (Figure 3): position of tall buildings with respect to south (northern hemisphere) and its exposure to solar radiation and overshadowing over low-rise buildings within the cluster; d. Solar access, solar radiation and albedo (Figure 4); e. Urban canyons (Figure 5). Figure 2 Urban Geometry. Figure 3 Orientation and Overshadowing. 30th ITERATIOAL PLEA COFERECE 2

Reflection SVF L Absorption Absorption Figure 4 Solar radiation and albedo. H θ W α Canyon Axis Figure 5 Urban canyon. CASE STUDIES This study assessed two different high-rise urban typologies in London to understand the interaction/impact of buildings at the urban scale. Results from simulations as well as real data recorded in a summer period are presented next. Cluster 1: Canary Wharf, London Coordinates: 51.5036 0.0183 W for 1 Canada Square, Figure 6 Solar access and solar radiation: The Central garden is the biggest open space within the Canary Wharf cluster. It works as a buffer space as a result of the microclimate conditions originated within these high-rise buildings of the square. The average direct solar radiation ranges from 120Wh to more than 1200Wh during the summer months from June to August. As seen in Figure 7, the road along the edge of the south buildings receives very low radiation during day time (9 am to 5 pm), around 120Wh, while the open space in front of plaza receives much higher levels of solar radiation as facing buildings are distant enough to avoid significantly overshadowing. This correlates well with the monitored air temperature made at the plaza, the garden and the south-west corner low rise block during July 1 st to July 13 th 2011 as seen in Table 1 and elsewhere (Pandya, 2011). 0 200m Plaza Central Garden 550 m Road 550 m Figure 6 Canary Wharf cluster. Figure 7 Direct solar radiation June, July, August 9am to 5pm. The simulation results of direct solar access on vertical surfaces, as shown in Figure 8, reveal that the unobstructed south edge buildings receive almost 6000Wh/m2 during Summer solstice. Buildings on the north side of the central garden have much lesser solar access. This amounts to around 2000Wh at ground level, increasing to around 4000Wh on top of the façade, as surrounding buildings no longer significantly obstruct high storeys. This has an impact on temperature and daylight availability to the spaces. 30th ITERATIOAL PLEA COFERECE 3

Figure 8 Solar access on Summer solstice. Urban Air Flow: For both clusters, CFD Simulations with EVI-MET software were made. Results are presented for July 1 st at 9am. The average wind speed is 3m/s and the prevailing wind direction in July is southwest (as per meteorological data for London). Figure 9, location A highlights that within the narrow canyons the wind flow vectors are longer which means high speed, while at the open spaces such as Reuters plaza or at the central garden, the wind speed is less intense and there are no significant deviations in the direction as a result of lack of obstructing tall buildings. 1 A Reuters Plaza Central Garden B Reuters Plaza Figure 9 Wind flow simulation plan on July 1st, 9am. Figure 10 Wind flow simulation - Section 1. Figure 10 shows that when buildings are fairly distant, downward wind loses its speed when it enters the larger open space. As it reaches the opposite high-rise building, the speed increases gradually. At the Canary Wharf cluster the corners of the buildings or edge conditions are most affected by incoming wind with higher speeds and get deviated due to obstructing edges as seen in Figure 9. This generates wind turbulences with high wind speed (see Figure 11). As both north and south edges are blocked by highrise buildings (Figure 9, location: B) wind turbulence and speed increases. Reuters Plaza Figure 11 Wind flow contour lines for wind speeds - Section 1. Cluster 2: Liverpool street, Bishopsgate, London Coordinates: 51.31, 0.4 W, Figure 12 Solar access and solar radiation: Liverpool Street is surrounded along their edges with continuous building facades. These urban canyons are mainly oriented 20 to 26 from north. Figure 13 shows that narrow streets, having smaller canyon ratios (width to height) receive a smaller amount of 30th ITERATIOAL PLEA COFERECE 4

direct solar radiation (street in front of Tower 42). The plaza, an important public space in the neighbourhood, receives more than 2500Wh. 0 200m Garden Swiss Re Tower 42 Plaza Figure 12 Liverpool street, Bishopsgate cluster Figure 13 Direct solar radiation - June, July, August. 9am to 5 pm Figure 14 Solar Access on Summer solstice In case of the Swiss Re building, the rear open space is used as a café and restaurant esplanade during summer, as it benefits form direct sun from southeast and south. This is not the situation at the front entrance as it is blocked by continuous buildings, and solar radiation is reduced to 500Wh. Figure 14 shows that the orientation of canyons/streets and buildings heights along the edge of them, can significantly affect the solar access at ground level, from 400 to 1500Wh/m2. Solar access on the façade at higher floors can reach 7500Wh/m2. At this cluster most of the high-rise buildings are fully glazed with anti-reflective glass, other surfaces also have reduced albedo. This prevents a high amount of solar radiation to be reflected towards the surrounding cluster. Conversely it may minimize problems of reflected glare. However, it is likely to increase the cooling loads of the spaces as well as aggravate thermal stress at the façade. Urban Air Flow: The irregular urban geometry of the Liverpool street cluster, with varying canyon orientations and monotonous flat building fabrics, shows dramatic changes in wind flows. Figure 15, Location A Bishopsgate road is a narrow canyon with building heights around 25 to 40m. The length of the canyon is about 65m and its orientation is southwest to northeast. This geometry permits the southwest wind with high speed entering the canyon. Figure 16, Section 1 shows airflow vectors going in the negative direction, upward, as a result of the close vertical surfaces on both sides of the in-between space. As the aspect ratio (H/W) is quite high, the incoming wind speed is higher than the one flowing above the roof of the building. 30th ITERATIOAL PLEA COFERECE 5

A 1 Figure 15 Wind flow simulation on 1 st July at 9am. Figure 16 Wind flow simulation - Section 1. Figure 17 Wind flow contours for wind speed - Section 1. The irregular street pattern and building edges create negative turbulences (Figure 17) that affect the wind flow and speed. This phenomenon is stronger around tall buildings. COMPARATIVE AALYSIS Table 1 Comparative analysis of Canary Wharf & Liverpool Street clusters, London. Clusters Total Built up area (m²) High Rise building foot print (m²) Tall building Height range (m) Canary Wharf 302,500 (Cluster coverage) 302,500 (Cluster coverage) 153 67,624 (built---up) 35,769 (built---up) 140 105 200 235 Liverpool Street 302500 m² 302,500 (Cluster coverage) 302,500 (Cluster coverage) 158,114 16108 125 100 93 180 242 Clusters Urban Geometry in Plan Urban Canyon profiles Canyon Orientations Canary Wharf 235 m S 8 98 Liverpool Street 242 m S S 26 34 116 S The urban geometry of the Canary Wharf cluster has a regular organization of buildings along the road edges with open spaces within. The Liverpool Street cluster presents an irregular street pattern and the building footprint follow the available space. As seen in Table 1, the cross sectional profiles of 30th ITERATIOAL PLEA COFERECE 6

canyons within Liverpool Street cluster are narrower on the north-south axis and the scattered high-rise buildings pop up in the low-rise settlement. This kind of geometry shows uneven height variations in the cross sectional profile of the canyons. Table 2 Comparative Analysis of Canary Wharf & Liverpool Street clusters, London. Clusters Street Pattern Sky View Factor Direct Solar Radiation Map Canary Wharf 1200 Wh 0.35 0.37 0.252 max. avg. AVG. street 0.23 for 0.18 plaza summer 0.13 garden months Liverpool Street garden street plaza 0.22 0.26 0.26 0.2 0.49 0.286 AVG. 2280 Wh max. avg. for summer months Clusters Green Cover (m²) Air Temperature ( c) 01/07/2011 Relative Humidity (%) 01/07/2011 Canary Wharf 302,500 (Cluster coverage) 13,244 (green cover) 25.1 25.5 24 24.7 23.3 24.2 Liverpool Street 302,500 (Cluster coverage) 2,344 (green cover) Plaza Street Garden Plaza Street Garden 26.4 25.8 25.7 22.9 23.2 22.9 Plaza Street Garden Plaza Street Garden The garden area of Liverpool Street shows higher air temperature and lower humidity than the street and plaza places (lowest temperature and high relative humidity). Conversely the Canary Wharf garden has lower air temperature and higher humidity than other parts of the cluster. Similarly, the open space like the plaza has higher wind speeds and the garden has lower wind speed due to the trees blocking the landscape. The variations in wind speeds at different places is also dependent on the prevailing wind direction and the urban fabric characteristics such as building heights, vegetation, water body and so on. The comparison of spot measurements of air temperatures at the three locations: plaza, streets and garden areas, revealed that the plaza at Canary Wharf has high air temperature during afternoon hours. See Table 2. This is a result of the hard paved surfaces with high reflectance and better solar exposure versus a more shadowed garden with high evapotranspiration. The Liverpool Street plaza appears to be more affected by the proximity of the surrounding buildings, their irregular geometries (ie more surface area) with low surface reflectance and higher thermal mass, hence absorbing more direct solar radiation. Heat is released to the air later at night when temperatures are lower. The open space is also more in the shadow. Therefore during day the air temperature remains low. Taking this study in consideration the most prominent bioclimatic factors affecting the urban microclimate are: urban geometry, urban canyons, sunlight availability and solar radiation, urban air flow, urban landscape and urban air quality and surface materials. It is understood that all are interdependent. However, the geometry, orientation and fabric of the buildings strongly impact the amount of solar radiation being absorbed/reflected by building facades and streets. The climatic conditions and building geometry play a major role at promoting sunlight availability, ameliorating air temperature and promoting air flow/ventilation to spaces. 30th ITERATIOAL PLEA COFERECE 7

COCLUSIOS Environmental factors such as air temperature and humidity, wind speed and direction, solar radiation and daylight conditions, noise and air pollution at ground level can make open areas in cities an appealing and comfortable place for pedestrians. Results presented above discuss the influence of these factors within two high-rise clusters in London. Furthermore, they strongly impact the energy performance of surrounding buildings and its comfort conditions and should be given much thought towards sustainable urbanism within existing and future cities. Canary Wharf has a rich landscape planning in terms of public realm, environmental sustainability, ecology and usage. The central garden permits solar access, a pleasant airflow and acts as a sound barrier from busy roads nearby. Road includes coniferous trees, which helps disperse the pollution particles within the canopy layer. Deciduous trees at the street side provide protection from direct sun and wind turbulence whilst still allows air movement between the trees and the adjacent buildings for ventilation. Liverpool Street has a compact and dense urban fabric with reduced open spaces, which can be used for urban landscape. Trees in internal courtyards of buildings may be beneficial to the building and its users but not at the urban scale. In hot periods, when the temperature rises above comfort level, direct and the reflected solar radiation from building surfaces increase the Heat Island effect. To minimize this, soft paved surfaces such as sand gravels or green patches of lawn and tree cover are necessary. Climate resilience and demands for sustainable living are not limited to environmental friendly building design, but requires much more attention to bioclimatic factors affecting the urban fabric and its microclimate. Bioclimatic factors can be man made or organic but ultimately affect human living conditions and the environment. It is a necessity to tackle at both building and urban scale. ACKOWLEDGMETS The first author acknowledges the following individuals and institutions: his parents and family members, CEPT University in Ahmedabad, India; Dr Luisa Brotas, Course Leader of MSc Architecture Energy & Sustainability at London Metropolitan University, Dr Axel Jacobs and Professor Fergus icol from London Metropolitan University as well as London Metropolitan University for the Scholarship Award that made this study possible; The Architectural Association, School of Architecture in London, the London underground and Bus transport; and last but not least The Almighty God for giving directions and courage to overcome all the obstacles and paths to success. OMECLATURE θ W H L α = the line running north-south and angle between canyon axis which determines the orientation of urban canyon = width of street = average height of buildings on both sides = length of canyon = angle between building top edge and street plane SVF = sky view factor REFERECES Clair, P.S, 2010. The Climate of Tall buildings- An investigation of building height and bio-climatic design. Available at: http://www.peterstclair.com/pdf/the-climate-of-tall-buildings-science- Review_LR.pdf [accessed: May 17, 2011] EHS, 2012. English Housing Survey: Homes report 2010, Department for Communities and Local Government, ational Statistics, Crown copyright Erell, E. et. al, 2011. Urban Microclimate: Designing the spaces between buildings. London: Earthscan. GLA, 2014. Great London Authority. https://www.london.gov.uk/ [accessed: September 10, 2014] Littlefair, P.J, et. al, 2000. Environmental site layout and planning, London: BRE Publications Pandya S., 2011. Tall Buildings and Urban Microclimate: A Bioclimatic study of urban fabric, MSc Thesis, London Metropolitan University 30th ITERATIOAL PLEA COFERECE 8