Urban Environment: constraints and opportunities towards a sustainable quality

Size: px
Start display at page:

Download "Urban Environment: constraints and opportunities towards a sustainable quality"

Transcription

1 Urban Environment: constraints and opportunities towards a sustainable quality A. FERRANTE*, A. BAROZZI*, C. MASOTTI*, A. MAVER* AND G. MIHALAKAKOU** * University of Bologna, DAPT, Department of Architecture and Urban Planning, Faculty of Engineering, Viale Risorgimento 2, Bologna, ITALY areffe@tin.it ** University of Athens, Department of Physics, Division of Applied Physics, Laboratory of Meteorology, University Campus, Build. Phys-V, Athens, GR157 84, GREECE Abstract To investigate the impact of bio-climatic techniques on energy efficiency in urban areas, a series of major factors influencing energy and buildings in urban environments imposing specific restrictions and priorities not encountered in non-urban areas has to be considered: urban historical and geometrical constraints, specific legislation regulating urban spaces, as well as the complex nature of the surfaces in the city lead to both conceptual and practical difficulties. A new, integrated planning and design procedure for the environmental and climatic rehabilitation of urban areas has been worked out in the framework of a complex case study in the Ex-Staveco area which is a large urban area close to the city centre of Bologna consisting of a huge amount of historical industrial buildings ( square meters) overlapping combined water and natural green systems, for a total densely-built urban zone of about square meters. The design methodology, performing the integration of the individual buildings design in the framework of a guide-line master plan defining urban, historical and bio-climatic goals, is essentially based on a threefold rehabilitation procedure considering: decision-making and strategies of action aimed at a "night and day living" city where Office Buildings, Science and Technological Museums, Hotels, Green Sport Centres, Commercial Centres and Parking Areas ensure a multi-functional use of urban spaces and buildings throughout the different time periods; large scale planning techniques related to the alternative use of natural resources in the public open areas (promotion of all forms of passive natural devices according to the potential effects of minimising localised pollution problems and enhancing urban microclimate); passive technological measures involving the envelope of existing buildings as well as the design of new buildings (improvement of solar heating and natural cooling, minimising solar heat gains both in the open spaces and on the building s facades). The thermal behaviour of different buildings using passive heating and cooling techniques have been calculated. The present paper shows the thermal performance of one selected building by a transient building s performance simulation program (TRNSYS, 1997). Conference topics: case studies Keywords: architecture, Energy, Green, Natural, Open, Passive, Simulation, Techniques, Temperature, Urban INTRODUCTION The present work, developed during the two-years Design Training Course for students of Engineering at the University of Bologna, was designed primarily to investigate the city as an integrated system, consisting of practical and theoretical issues on energy loading of buildings and vegetative organisms, and secondly to apply various important bio-climatic design techniques aiming at improving the microclimate as well as the overall qualitative conditions of a large urban area. To investigate the impact of bioclimatic techniques on energy efficiency in urban areas, a series of major factors influencing energy and buildings in urban environments imposing specific restrictions and priorities not encountered in non-urban areas has to be considered: urban historical and geometrical constraints, specific legislation regulating urban spaces, as well as the complex nature of the surfaces in the city lead to both conceptual and practical difficulties. The study and application of natural passive systems on the city environment is a multi-layered and multidisciplinary process [1]: it is especially important to treat the subject in conjunction with other aspects of physical parameters involving passive and active components and techniques in relation to architectural and engineering design. For these reasons the rehabilitation of the urban area has to be multi-dimensional in approach, encompassing enhancements to the physical environment, with a view to improving the quality of life for residents. Thus, the identity of an area should be enhanced, not destroyed, especially in 843

2 terms of cultural heritage and preservation of the positive aspects of existing built and natural environments. THE URBAN RENEWAL OF THE AREA "EX_STAVECO" The design procedure A new, integrated planning and design procedure for the environmental and climatic rehabilitation of urban areas has been worked out in the framework of the Ex-Staveco area which is a large urban area close to the city centre of Bologna consisting of a huge amount of historical industrial buildings ( square meters) overlapping combined water and natural green systems, for a total densely-built urban zone of about square meters. The design procedure, considering the existing historical and urban constraints both deriving from urban conditions and natural-physical aspects to be enhanced, has lead to a general guide-line master plan defining urban, historical and bio-climatic goals: the restriction of the amount of possible solutions resulting from existing urban constraints has been thus combined with the first priority of achieving thermal comfort by natural means in urban spaces. The significance of landscape and urban re-planning at this scale is undoubtedly evident, considering that the rehabilitation process of buildings cannot exist separately from the restoration process of the whole area. For the same reason the building design methodology has been conceived as an approaching process from the outside spaces to the buildings. The influence of outdoor spaces on the architectural design procedure is described in detail [2] e [3]. The approach of conceiving the volumes to be built as the negative counterparts of the positive open spaces working from the outside inwards has been applied throughout the planning and architectural procedure of the present case study. The design methodology is essentially based on a threefold rehabilitation procedure considering: decision-making and strategies of action aimed at a "night and day living" city where Office Buildings, Science and Technological Museums, Hotels, Green Sport Centres, Commercial Centres and Parking Areas ensure a multi-functional use of urban spaces and buildings throughout the different time periods; large scale planning techniques related to the alternative use of natural resources in the public open areas (promotion of all forms of passive natural devices according to the potential effects of minimising localised pollution problems and enhancing urban microclimate); passive technological measures involving the historical existing buildings' facades as well as the design of new buildings (improvement of solar heating and natural cooling, minimising solar heat gains both in the open spaces and on the building s facades). Climatic and environmental rule of natural components and passive techniques Plants have a strong effect on climate: trees and green spaces can help cooling our cities and save energy. Trees are able to provide solar protection to individual houses during the summer period while evapotranspiration from trees can reduce urban temperatures. Trees also help mitigate the greenhouse effect, filter pollutants, mask noise, prevent erosion and calm their human observers. Moreover, evapotranspiration from soil - vegetation systems can remarkably reduce urban temperatures. Shading from trees is an effective way for reducing significantly the energy for cooling purposes. Results of computer simulations aimed at studying the combined effect of shading and evapotranspiration of vegetation on the energy use of several typical one-storey buildings in US cities have showed that by adding one tree per house, the cooling energy savings varied from 12 to 24 %, while adding three trees per house can reduce the cooling load between 17 to 57 percent. According to this study, the direct effects of shading account for only 10 to 35 % of the total cooling energy savings. The remaining savings result from temperatures lowered by evapotranspiration. The evaporative and transpiration cooling effects of plants are used to pre-cool ventilation air, for buildings and open spaces. Dense vegetation furthermore helps to filter particles from air. The air temperature and the relative humidity are reduced as the air passes through the foliage covering the roof. The plants, because of the biological functions of photosynthesis, respiration, transpiration and evaporation, absorb a significant proportion of solar radiation, creating a protective layer and thus reducing temperature during summer. The climatic conscious design of outdoor spaces and the appropriate use of natural components are key elements to reduce the outcome of unsound evolution of urban zones such as the Ex-Staveco Area, where large surfaces of vegetation can improve the thermal performance of the whole area, while offering a public refreshing area close to the city centre. The main objectives identified in the overall rehabilitation procedure of the Ex-Staveco area can be summarised as follows: Promotion of all forms of passive natural devices according to the potential effects of minimising localised pollution problems and enhancing urban microclimate; Increase of permeable surfaces in the outdoor spaces; Improvement of solar heating and natural cooling, minimising solar heat gains both in the open spaces and on the building s facades (allowing protection for south-east and south-west facades by means of shading devices and natural filters ). Ensure CO 2 absorption by plants and urban pollutant dispersion by natural ventilation and night cooling. To achieve the above objectives the following strategies have been proposed: 844

3 Ensure "openings" from existing green parks outside the area (where a higher portion of fresher and cleaner air is available) towards public open spaces and buildings facades by means of proposed pedestrian green ways (climatic corridors) considering the direction of prevailing summer breeze crossing the area Ex-Staveco; Increase as much as possible permeable surfaces on the pavements thus enhancing the water-green-climate interactions; Provide shading and filtering for the buildings facades (especially the south-west oriented ones during the warm period of the year) by means of vegetation, water ponds and water river extension in pools eventually equipped with macrophitic treatment of waste water; Provide spatial separation between polluted areas and open public spaces; Ensure openings from the pedestrian areas towards the buildings facades; Provide shading and filtering for the buildings facades (especially on the south-west orientation in warm summer season and north-east ones in cold winter season) by means of selected passive techniques such as winter gardens, pergolas, deciduous trees and curtains. The urban area has therefore been restored by means of various design previsions such as: Definition of potential ecological networks (green belts and bio-climatic corridors as "widespread quality" pattern) where existing (or designed) open green areas inside and outside the area boundaries are support links in a system of quality interconnected elements; Partial demolition of the industrial buildings without urban and historical significance presenting very high levels of unhealthy conditions; Re-balance the environmental processes aimed at the climatic improvement in the relatively free open spaces (existing or in prevision); Urban rehabilitation of the main crossing central routes towards the historical centre as pedestrian galleries crossing the commercial, social and public activities; Insertion of selected passive systems such as atrium between existing historical buildings along the high circulation streets intimately connected to the whole urban rehabilitation. Figure 1. Schematic aereal view of the new urban plan in the Ex-Staveco area of Bologna 845

4 Figure 2. Schematic 3-D section of the new underground railway station used for the thermal performance simulation by TRNSYS. THE SUNSPACE AS A PASSIVE HEATING/COOLING SYSTEM Sunspaces and atriums as architectural techniques have been throughout employed in the design and rehabilitation of the main buildings in the Ex-Staveco area. Sunspaces represent acceptable ecological solutions contributing to the reduction of the thermal loads of the building s envelope and to the improvement of microclimatic conditions of public urban spaces. The glass covering systems between the coupled buildings fronting the high circulation street, for example, lead to a thermally compact building during the winter period where heat losses from the buildings are reduced, while the passive gained solar energy can be very useful. In the new underground railway station the atrium contributes significantly to the energy balance of the office buildings as well as to the thermal performance of the open public space itself. To achieve an improved thermal performance in the winter, that is to gain heat from solar radiation, the atrium has been assumed closed by two glazed entrances, while for avoiding the undesirable overheating during the summer period of the year the following bioclimatic techniques have been considered: the openings of glazed entrances should facilitate ventilation techniques during the summer; additionally, the openings at the top have the important task of extracting the hot air. accordingly, the outdoor air is allowed to enter inside the atrium and remove the stored heat which is trapped during the day; also, the air movement from underground tubes and volumes provides a considerable increase of heat dissipation from the ground towards the atrium itself as well as the building materials, and the warmer air is exhausted into the low temperature atmospheric heat sink.; insertion of curtains as additional selected passive systems addressing the cooling need of the buildings and the atrium during summer. These shading devices can be useful for avoiding the overheating process, by reducing direct solar gain. CALCULATION OF THERMAL PERFORMANCE The thermal behaviour of the railway station was calculated using the TRNSYS environment (*). TRNSYS is a transient system program with a modular structure which facilitates the addition to the program of mathematical models not included in the standard TRNSYS library. The whole building was considered to be one thermal zone, with floor on the ground. The building is connected, on its south side, with an atrium, (Fig. 2). Simulations have been performed using an hour as the time interval taking into account that all measurements were taken on an hourly basis. Hourly values of the following climatic parameters for the city of Bologna, have been used for the calculations: Ambient air temperature, ( C) Global solar radiation, (W/m 2 ) Diffuse solar radiation (W/m 2 ) Relative humidity, (%) Figure 3 shows the ambient air temperature values for one representative day of July as well as the indoor air temperature values calculated inside : 1. the building when it is not connected with the atrium 2. the same building connected with the atrium. 846

5 CONCLUDING REMARKS Figure 3. Thermal performance for a representative summer day. From Figure 3, it can be seen that the ambient air temperature values varied between 14.1 and 35.2 C, the indoor temperature inside the building not connected with the atrium fluctuated between 13.8 and 33.2 C, while the indoor temperature of the building connected with the atrium varied in the range of 11.5 and 28.2 C. Accordingly, Figure 4 shows the ambient air temperature values for one representative day of January as well as the indoor air temperature values calculated inside: the building when it is not connected with the atrium the same building connected with the atrium. As shown, the ambient air temperature values varied in the range of 3.2 and 10.2 C, the indoor temperature inside the building not connected with the atrium fluctuated between 3.9 and 10.9 C, while the indoor temperature of the building connected with the atrium varied in the range of 4.7 and 13.5 C. A new, integrated planning and design procedure for the environmental and climatic rehabilitation of urban areas is presented in this paper. The methodology is essentially based on a rehabilitation procedure considering both large scale landscape planning techniques related to the alternative use of natural resources such as water and green and passive technological measures involving the envelope of historical buildings. The overall basis of the architectural measures proposed in the present case study lies in the value of green, water and selected passive techniques to improve microclimate in the urban sites. Furthermore, passive selected techniques such as sunspaces have been throughout employed in the design and rehabilitation of the main buildings in the Ex-Staveco area. An extensive validation procedure has been followed describing the thermal performance of the atrium and one representative building during the summer and winter period of the year. From the obtained results it is found that: As expected, the air temperature inside the atrium is satisfyingly higher than the external ambient temperature in the winter and similarly lower during the summer, thus demonstrating the gallery to be a pleasant public open space. The thermal performance of the connected building is therefore strictly influenced, governed and improved by the presence of the atrium itself. ACKNOWLEDGMENTS Figure 1, representing the plan-volumetric view of the area, was designed by A. Ferrante and drew by F. Giulianelli. Fig. 2 has been designed by F. Giulianelli and revised by A. Ferrante. The authors would like to express their gratitude to F. Giulianelli for his valuable help. REFERENCES Figure 4. Thermal performance for a representative winter day. Santamouris, M., N. Papanikolaou, I. Livada, I. Koronakis, C. Georgakis, A. Argiriou and D. Asimakopoulos (1998), On the impact of urban climate on the energy consumption of buildings, Sol. Energy. Tombazis A.N. (1995) The design of exterior spaces in relation to their effect on the indoor climate of buildings, Proceedings of the International Symposium Passive Cooling of Buildings, Athens, Greece, pp Bitan A. (1992), The high climatic quality of the city of future, Atmospheric Environment 26B, pp Goulding J., Lewis J.O., and Steemers T.C. (1993), Energy in Architecture - The European Passive Solar Handbook, E.U. Publication, Batsford, London. (*) TRNSYS 14 (1997), A transient system simulation programme developed from Solar Energy Laboratory, University of Wisconsin, Madison, and Transsolar, Stuttgart. 847

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to: PASSIVE Solar Design Solar Homes Catch the Sun Are you planning a new house? Discover how you can apply solar architecture principles to: keep your heating bills to a minimum enjoy the comfort of a warm

More information

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi Climate and Energy Responsive Housing in Continental Climates The Suitability of Passive Houses for Iran's Dry and Cold Climate Farshad Nasrollahi Table of Contents Abstract German Abstract Introduction

More information

Cool Spaces. earth-wise guide to. green strategies: light strategies: Keep Austin Cool

Cool Spaces. earth-wise guide to. green strategies: light strategies: Keep Austin Cool earth-wise guide to Cool Spaces green strategies: 1. Trees and leafy plants 2. Green roofs 3. Green walls light strategies: 4. Reflective roofs 5. Permeable pavement 6. Shade structures Keep Austin Cool

More information

A DISTANT-LEARNING TRAINING MODULE ON ENERGY EFFICIENT INTEGRATED BUILDING DESIGN IN URBAN ENVIRONMENT

A DISTANT-LEARNING TRAINING MODULE ON ENERGY EFFICIENT INTEGRATED BUILDING DESIGN IN URBAN ENVIRONMENT A DISTANT-LEARNING TRAINING MODULE ON ENERGY EFFICIENT INTEGRATED BUILDING DESIGN IN URBAN ENVIRONMENT V.Geros 1, M.Santamouris 1, S. Amourgis 2, S. Medved 3, E. Milford 4 and K. Steemers 5 1. Group Building

More information

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries

More information

The Sino-Italy Environment & Energy Building (SIEEB): A model for a new generation of sustainable buildings

The Sino-Italy Environment & Energy Building (SIEEB): A model for a new generation of sustainable buildings International Conference Passive and Low Energy Cooling 935 for the Built Environment, May 25, Santorini, Greece The Sino-Italy Environment & Energy Building (SIEEB): A model for a new generation of sustainable

More information

RESSÒ: energy efficiency urban rehabilitation

RESSÒ: energy efficiency urban rehabilitation RESSÒ: energy efficiency urban rehabilitation Authors: Bodelon, Carmen 1 ; Gascón, Eduardo 1 ; Ramon, Guillem 1 ; Obiols, Martí 1 ; Palomar, Pablo 1 ; Escoda, Quim 1 ; Prat, Sandra 1 ; Illa, Sergi 1 ;

More information

Adaptive strategies for office spaces in the UK climate

Adaptive strategies for office spaces in the UK climate International Conference Passive and Low Energy Cooling 631 Adaptive strategies for office spaces in the UK climate I. Gallou Environment & Energy Studies Programme, Architectural Association Graduate

More information

Klosterenga, Oslo, Norway, 1998-2000 page - 1

Klosterenga, Oslo, Norway, 1998-2000 page - 1 Klosterenga, Oslo, Norway, 1998-2000 page - 1 Introduction Klosterenga is an urban revitalisation project close to the city centre of Oslo. The 3 apartments were built with a focus on energy saving. Next

More information

Energy-Plus Primary School, Hohen Neuendorf, Germany

Energy-Plus Primary School, Hohen Neuendorf, Germany Energy-Plus Primary School, Hohen Neuendorf, Germany Ingo LÜTKEMEYER, Prof. Dipl.-Ing. Architekt BDA 1 Jens KRAUSE, Dipl. Ing. 2 Günter LÖHNERT, Dr. Ing. 3 Holger KÖNIG, Dipl.-Ing. 4 Detlef HENNINGS, Dr.

More information

LATITUDES INTERNATIONAL DESIGN CHALLENGE 2015-16

LATITUDES INTERNATIONAL DESIGN CHALLENGE 2015-16 LATITUDES INTERNATIONAL DESIGN CHALLENGE 2015-16 Design Challenge Resilient working environments: carving the city for small businesses in London Submitted by: University of Westminster MSc Architecture

More information

Each icon on this map represents the physical location of a station.

Each icon on this map represents the physical location of a station. ABBOTSFORD SCHOOL DISTRICT: GREEN TOUR TOMORROW S SUSTAINABLE SOLUTIONS TODAY Welcome to the Abbotsford School District: Green Tour. Our goal is to create an interactive learning experience for visitors

More information

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010 EFA PSBP Natural Ventilation Strategy Introduction The Baseline Designs Project will provide scheme design details for a number of Primary and Secondary School Exemplars. For the purposes of setting a

More information

Optimum Solar Orientation: Miami, Florida

Optimum Solar Orientation: Miami, Florida Optimum Solar Orientation: Miami, Florida The orientation of architecture in relation to the sun is likely the most significant connection that we can make to place in regards to energy efficiency. In

More information

VENTILATIVE COOLING EBC ANNEX 62 PER HEISELBERG DEPARTMENT OF CIVIL ENGINEERING

VENTILATIVE COOLING EBC ANNEX 62 PER HEISELBERG DEPARTMENT OF CIVIL ENGINEERING VENTILATIVE COOLING EBC ANNEX 62 PER HEISELBERG DEFINITION OF VENTILATIVE COOLING VENTILATIVE COOLING IS APPLICATION (DISTRIBUTION IN TIME AND SPACE) OF VENTILATION AIR FLOW TO REDUCE COOLING LOADS IN

More information

AIR CONDITIONING - ENERGY CONSUMPTION AND ENVIRONMENTAL QUALITY

AIR CONDITIONING - ENERGY CONSUMPTION AND ENVIRONMENTAL QUALITY CONTENTS AIR CONDITIONING - ENERGY CONSUMPTION AND ENVIRONMENTAL QUALITY Air Conditioning - Energy Consumption and Environmental Quality - Volume 1 No. of Pages: 400 ISBN: 978-1-84826-169-3 (ebook) ISBN:

More information

Opening the Bonnet. Prof Darren Woolf WYSINWYG 1

Opening the Bonnet. Prof Darren Woolf WYSINWYG 1 Opening the Bonnet Prof Darren Woolf WYSINWYG 1 WYSINWYG What You See Is NOT What You Get: Looking inside the Pandora s Box Prof Darren Woolf WYSINWYG 2 WYSIWYG implies a user interface that allows the

More information

Federation of European Heating, Ventilation and Air-conditioning Associations

Federation of European Heating, Ventilation and Air-conditioning Associations Federation of European Heating, Ventilation and Air-conditioning Associations Address: Rue Washington 40 1050 Brussels Belgium www.rehva.eu info@rehva.eu Tel: +32 2 514 11 71 Fax: +32 2 512 90 62 REHVA

More information

Heating and Ventilation

Heating and Ventilation Baltic Environmental Forum Latvia Antonijas iela 3-8 LV-1010 Riga, Latvia www.bef.lv Baltic Environmental Froum Deutschland e. V. Osterstraße 58 20259 Hamburg, Germany www. bef-de.org Heating and Ventilation

More information

Building Energy Systems. - HVAC: Heating, Distribution -

Building Energy Systems. - HVAC: Heating, Distribution - * Some of the images used in these slides are taken from the internet for instructional purposes only Building Energy Systems - HVAC: Heating, Distribution - Bryan Eisenhower Associate Director Center

More information

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design Building Performance Simulation for Designers - Energy DesignBuilder // EnergyPlus Tutorial #2 Load Schedules GEOMETRY LOADS RESULTS Diego Ibarra Christoph Reinhart Harvard Graduate School of Design OVERVIEW

More information

Green House, Hungary

Green House, Hungary Further information Skanska AB www.skanska.com Contact Noel Morrin, SVP Sustainability & Green Support noel.morrin@skanska.se Green House, Hungary Case Study 109 Aspects of Sustainability This project

More information

Energy savings in the residential area are essential in

Energy savings in the residential area are essential in Overheating and insufficient heating problems in low energy houses up to now call for improvements in future Requirements for improved energy performance have shifted major focus on energy calculations

More information

Design and Re-Use Of Shovadans In Today's Architecture "With Due Attention To Have Thermal Energy Of The Earth"

Design and Re-Use Of Shovadans In Today's Architecture With Due Attention To Have Thermal Energy Of The Earth RESEARCH INVENTY: International Journal of Engineering and Science ISBN: 2319-6483, ISSN: 2278-4721, Vol. 1, Issue 8 (November 2012), PP 60-64 www.researchinventy.com Design and Re-Use Of Shovadans In

More information

Effects of Solar Photovoltaic Panels on Roof Heat Transfer

Effects of Solar Photovoltaic Panels on Roof Heat Transfer Effects of Solar Photovoltaic Panels on Roof Heat Transfer A. Dominguez, J. Kleissl, & M. Samady, Univ of California, San Diego J. C. Luvall, NASA, Marshall Space Flight Center Building Heating, Ventilation

More information

Air Conditioning, Comfort and Energy in India s Commercial Building Sector

Air Conditioning, Comfort and Energy in India s Commercial Building Sector Air Conditioning, Comfort and Energy in India s Commercial Building Sector THINK.CHANGE.DO Leena Thomas Richard dedear Rajan Rawal Ashok Lall PC Thomas University of Technology, Sydney Sydney University

More information

Energy efficient home design

Energy efficient home design Energy efficient home design GUIDELINES How an energy efficient home can help you live in comfort and save money An energy efficient home is designed to provide shade and allow cooling breezes to enter

More information

Corralling the evidence about the value of Green Infrastructure. Martin Moss. Senior Advisor Green Infrastructure Operations England.

Corralling the evidence about the value of Green Infrastructure. Martin Moss. Senior Advisor Green Infrastructure Operations England. Corralling the evidence about the value of Green Infrastructure Martin Moss. Senior Advisor Green Infrastructure Operations England. Flow of discussion. Part 1 - What do we mean by GI? Part 2 - What are

More information

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment The heating, ventilation and cooling loads of typical commercial office space can range

More information

Green BIM/ Early BIM/

Green BIM/ Early BIM/ Green BIM/ Early BIM/ Agenda/ Introduction to Sustainability Process Environmental Analysis Tools Environmental Analysis Relation to LOD Conclusion Disclaimer/ This seminar is looking at Building Performance

More information

Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics

Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics A Presentation of Work in Progress 4 October 2006 in the Intelligent

More information

Za abeel Energy City Master Plan. Dubai, United Arab Emirates

Za abeel Energy City Master Plan. Dubai, United Arab Emirates Dubai, United Arab Emirates Dubai, United Arab Emirates The Energy Master Plan is uniquely positioned as a center for both commerce and residential development. The project will embody modern, sustainable

More information

Building envelope and heat capacity: re-discovering the thermal mass for winter energy saving

Building envelope and heat capacity: re-discovering the thermal mass for winter energy saving 346 2nd PALENC Conference and 28th AIVC Conference on Building Low Energy Cooling and Building envelope and heat capacity: re-discovering the thermal mass for winter energy saving S. Ferrari Politecnico

More information

ResearcH JournaL 2009 / VOL 01.01. www.perkinswill.com

ResearcH JournaL 2009 / VOL 01.01. www.perkinswill.com ResearcH JournaL 2009 / VOL 01.01 www.perkinswill.com PERKINS+WILL RESEARCH JOURNAL / VOL 01.01 05. CONTEXT BASED DESIGN OF DOUBLE SKIN FACADES Climatic Considerations During the Design Process Ajla Aksamija,

More information

Net Zero Station Design for The Cooper Centre for the Environmental Learning in Tucson, Arizona: Improving the performance of existing buildings

Net Zero Station Design for The Cooper Centre for the Environmental Learning in Tucson, Arizona: Improving the performance of existing buildings Net Zero Station Design for The Cooper Centre for the Environmental Learning in Tucson, Arizona: Improving the performance of existing buildings Alya Al-Hashim 1, Lena Spiric 2,and Nader Chalfoun 3 1,2

More information

Institute for Renewable Energy

Institute for Renewable Energy Institute for Renewable Energy EURAC and partners European Academy Bolzano The EURAC is an innovative institute for research and scientific training in South Tyrol. Founded in 1992 as private institution,

More information

HOW AN ENERGY EFFICIENT HOME CAN HELP THE ENVIRONMENT

HOW AN ENERGY EFFICIENT HOME CAN HELP THE ENVIRONMENT HOW AN ENERGY EFFICIENT HOME CAN HELP THE ENVIRONMENT During the last century, concern about the environment increased, as issues such as global warming and the Greenhouse Effect convinced us that the

More information

Holistic Approach in Delivering Government Buildings The Low Carbon Concept

Holistic Approach in Delivering Government Buildings The Low Carbon Concept International Conference on Planning for Low Carbon Cities 22 May 2009 Holistic Approach in Delivering Government Buildings The Low Carbon Concept Ir. HO Sai-king, Assistant Director (Building Services),

More information

Lesson 36 Selection Of Air Conditioning Systems

Lesson 36 Selection Of Air Conditioning Systems Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section

More information

Solar Energy Utilisation in Buildings

Solar Energy Utilisation in Buildings Solar Energy Utilisation in Buildings P. Karava, PhD Assistant professor Department of Civil and Environmental Engineering University of Western Ontario 2 Modern Buildings Change in architectural style

More information

DESIGN OF NATURAL VENTILATION WITH CFD CHAPTER SEVEN. Qingyan Chen. difficult to understand and model, even for simple

DESIGN OF NATURAL VENTILATION WITH CFD CHAPTER SEVEN. Qingyan Chen. difficult to understand and model, even for simple CHAPTER SEVEN L. Glicksman and J. Lin (eds), Sustainable Urban Housing in China, 116-123 2006 Springer. Printed in the Netherlands. DESIGN OF NATURAL VENTILATION WITH CFD Qingyan Chen INTRODUCTION As the

More information

Tall Buildings and the Urban Microclimate in the City of London

Tall Buildings and the Urban Microclimate in the City of London Tall Buildings and the Urban Microclimate in the City of London Sujal V. Pandya, B. Arch., M. Sc, COA Low Energy Architecture Research Unit London Metropolitan University, United Kingdom Luisa Brotas,

More information

Energy Pathways in Earth s Atmosphere

Energy Pathways in Earth s Atmosphere BRSP - 10 Page 1 Solar radiation reaching Earth s atmosphere includes a wide spectrum of wavelengths. In addition to visible light there is radiation of higher energy and shorter wavelength called ultraviolet

More information

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION 3.1 Purpose of Thermal Load Estimation 3.2 Heating Load versus Cooling Load 3.3 Critical Conditions for Design 3.4 Manual versus Computer Calculations 3.5 Heating

More information

Studies energy efficiency of the renewable sources use considering climate in Latvia

Studies energy efficiency of the renewable sources use considering climate in Latvia Available online at www.sciencedirect.com ScienceDirect Energy Procedia (25) www.elsevier.com/locate/procedia 6th International Building Physics Conference, IBPC 25 Studies energy efficiency of the renewable

More information

ENVIRONMENTALLY SMART GREEN ROOF SYSTEMS. Life on Roofs

ENVIRONMENTALLY SMART GREEN ROOF SYSTEMS. Life on Roofs ENVIRONMENTALLY SMART GREEN ROOF SYSTEMS Life on Roofs Company Overview Leadership and Innovation ZinCo Group is an international pioneer in designing and manufacturing green roof systems for high density

More information

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX Content Heating / Ventilation / Air Conditioning 3 The Right Room Climate 4 Optimised Energy Efficiency and well-being Room

More information

EVALUATION OF UNDERGROUND RAILWAY NETWORKS OPERATING SUSTAINABLE COOLING SYSTEMS. J.A. Thompson*, G.G. Maidment, J.F. Missenden and F.

EVALUATION OF UNDERGROUND RAILWAY NETWORKS OPERATING SUSTAINABLE COOLING SYSTEMS. J.A. Thompson*, G.G. Maidment, J.F. Missenden and F. EVALUATION OF UNDERGROUND RAILWAY NETWORKS OPERATING SUSTAINABLE COOLING SYSTEMS J.A. Thompson*, G.G. Maidment, J.F. Missenden and F. Ampofo Faculty of Engineering, Science and the Built Environment London

More information

Subtropical Cities September 2006. Design for Energy Efficiency in Commercial Buildings in Queensland

Subtropical Cities September 2006. Design for Energy Efficiency in Commercial Buildings in Queensland Subtropical Cities September 2006 Design for Energy Efficiency in Commercial Buildings in Queensland Contents Typical Building Constraints & Requirements Understanding Energy Consumption in Buildings HVAC

More information

RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary

RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary January 2013 TABLE OF CONTENTS INTRODUCTION... 3 GENERAL RECOMMENDATIONS... 3 Communication with customers in the field of environmental sustainability...

More information

Building skin and energy efficiency in a hot climate with particular reference to Dubai, UAE

Building skin and energy efficiency in a hot climate with particular reference to Dubai, UAE Energy and Sustainability 287 Building skin and energy efficiency in a hot climate with particular reference to Dubai, UAE M. A. Haggag UAE University, United Arab Emirates Abstract The city of Dubai,

More information

Energy Quiz. Questions:

Energy Quiz. Questions: Energy Quiz Want to have some fun and learn at the same time. This is not a test. You don t have to pass it and it won t give you a grade. It will just help you learn or find out how much you remember

More information

CH 2. green building design. Design snap shot 11: Biomimicry. Setting a new world standard in. Summary

CH 2. green building design. Design snap shot 11: Biomimicry. Setting a new world standard in. Summary CH 2 Setting a new world standard in green building design Design snap shot 11: Biomimicry Summary Introduction This snap shot discusses the use of biomimicry (from the Greek: bios meaning life; mimesis

More information

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Dienstleistung. Certification as Quality Approved Passive House Criteria for Residential-Use Passive Houses Passiv Haus Institut Passivhaus Dienstleistung GmbH Dr. Wolfgang Feist Rheinstr. 44/46 Rheinstr. 44/46 D-64283 Darmstadt D-64283 Darmstadt www.passiv.de www.passivhaus-info.de Certification as "Quality

More information

Residential HVAC Load Sizing Training October 14, 2015. David Kaiser Green Code Plan Reviewer

Residential HVAC Load Sizing Training October 14, 2015. David Kaiser Green Code Plan Reviewer Residential HVAC Load Sizing Training October 14, 2015 David Kaiser Green Code Plan Reviewer DCRA - Green Building Division Regulations of green codes including: Green Building Act Green Construction Code

More information

Sustainable water heating solutions through solar systems

Sustainable water heating solutions through solar systems VIESMANN Sustainable water heating solutions through solar systems Murat Aydemir Managing Director Viessmann Middle East FZE Viessmann is a Registered Provider with The American Institute of Architects

More information

AP ENVIRONMENTAL SCIENCE 2007 SCORING GUIDELINES

AP ENVIRONMENTAL SCIENCE 2007 SCORING GUIDELINES AP ENVIRONMENTAL SCIENCE 2007 SCORING GUIDELINES Question 4 Some scientists estimate that by 2025 over 60 percent of the global human population will live in urban areas. Urban residents experience a variety

More information

Environment and Urbanization

Environment and Urbanization Environment and Urbanization Microclimatic Variations in a Brownfield Site in Sao Paulo, Brazil Denise Duarte dhduarte@terra.com.br Joana Gonçalves jocarch@usp.br Laboratório rio de Conforto Ambiental

More information

Lecture No.4. 4.1 Active summer cooling systems. 4.1.1 Fan-and Pad cooling system. 4.1.2 Fog cooling system

Lecture No.4. 4.1 Active summer cooling systems. 4.1.1 Fan-and Pad cooling system. 4.1.2 Fog cooling system 1 Lecture No.4 Equipment required for controlling green house environment summer cooling and winter cooling, natural ventilation, forced ventilation and computers. Precise control of various parameters

More information

How a Ground Source Heat Pump Works for a School or College

How a Ground Source Heat Pump Works for a School or College How a Ground Source Heat Pump Works for a School or College Vertical System Image courtesy of Climate Master 1 Geothermal avoids the need for outdoor equipment..reducing vandalism and liability Image courtesy

More information

Integrated Solar Radiant Systems

Integrated Solar Radiant Systems Integrated Solar Radiant Systems William Shady PE President Topics Radiant heating Indoor air quality Radiant Cooling Project Photos Questions and answers The goal for our clients Healthy Comfort Why Radiant

More information

A comparative study of the thermal performance of reflective coatings for the urban environment

A comparative study of the thermal performance of reflective coatings for the urban environment International Conference Passive and Low Energy Cooling 101 A comparative study of the thermal performance of reflective s for the urban environment A. Synnefa, M. Santamouris and I. Livada National and

More information

APPLICATION OF DATA MINING TECHNIQUES FOR BUILDING SIMULATION PERFORMANCE PREDICTION ANALYSIS. email paul@esru.strath.ac.uk

APPLICATION OF DATA MINING TECHNIQUES FOR BUILDING SIMULATION PERFORMANCE PREDICTION ANALYSIS. email paul@esru.strath.ac.uk Eighth International IBPSA Conference Eindhoven, Netherlands August -4, 2003 APPLICATION OF DATA MINING TECHNIQUES FOR BUILDING SIMULATION PERFORMANCE PREDICTION Christoph Morbitzer, Paul Strachan 2 and

More information

Measures for reducing risk and increasing

Measures for reducing risk and increasing Design for Adaptation Measures for reducing risk and increasing resilience Flooding Avoiding flood risk areas, ensuring areas and buildings are resistant or resilient. Extreme weather Construction & design

More information

A Developer s Guide: Watershed-Wise Development

A Developer s Guide: Watershed-Wise Development A Developer s Guide: Watershed-Wise Development Environmental Protection What is a watershed? It does not matter how far away you build from a creek, lake, or the ocean, you are in a watershed. Another

More information

Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro

Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro Dept. Building Environment Science &Technologies Politecnico di Milano Italy Research funded

More information

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number 610.14351-R1D1. 13 January 2015

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number 610.14351-R1D1. 13 January 2015 EcoPelmet Pty Ltd c/- Geoff Hesford Engineering 45 Market Street FREMANTLE WA 6160 Version: Page 2 PREPARED BY: ABN 29 001 584 612 2 Lincoln Street Lane Cove NSW 2066 Australia (PO Box 176 Lane Cove NSW

More information

Mechanical and Natural Ventilation

Mechanical and Natural Ventilation BBSE3006: Air Conditioning and Refrigeration II http://www.hku.hk/bse/bbse3006/ Mechanical and Natural Ventilation Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong E-mail:

More information

HEALTHY BUILDINGS BUT LESS ENERGY CONSUMPTION How can Air Conditioning Technology help?

HEALTHY BUILDINGS BUT LESS ENERGY CONSUMPTION How can Air Conditioning Technology help? HEALTHY BUILDINGS BUT LESS ENERGY CONSUMPTION How can Air Conditioning Technology help? Proceedings of Healthy Buildings 94 Ben Bronsema, Consulting Engineer ONRI Ketel Consulting Engineers Ltd, DELFT

More information

HEATING-COOLING WALL PANELS SYSTEM IN SLOVENE ETHNOGRAPHIC MUSEUM

HEATING-COOLING WALL PANELS SYSTEM IN SLOVENE ETHNOGRAPHIC MUSEUM 01-147 The 2005 World Sustainable Building Conference, HEATING-COOLING WALL PANELS SYSTEM IN SLOVENE ETHNOGRAPHIC MUSEUM Aleš KRAINER Prof. Dr. 1 Rudi Perdan 2 Gal Krainer 3 1 2 Faculty of Civil Engineering,

More information

Seasonal & Daily Temperatures. Seasons & Sun's Distance. Solstice & Equinox. Seasons & Solar Intensity

Seasonal & Daily Temperatures. Seasons & Sun's Distance. Solstice & Equinox. Seasons & Solar Intensity Seasonal & Daily Temperatures Seasons & Sun's Distance The role of Earth's tilt, revolution, & rotation in causing spatial, seasonal, & daily temperature variations Please read Chapter 3 in Ahrens Figure

More information

Passive Solar Design and Concepts

Passive Solar Design and Concepts Passive Solar Design and Concepts Daylighting 1 Passive Solar Heating Good architecture? The judicious use of south glazing coupled with appropriate shading and thermal mass. Summer Winter Passive solar

More information

Energy efficiency saves you money and helps save the environment, so what can you do to improve the energy efficiency of your existing home?

Energy efficiency saves you money and helps save the environment, so what can you do to improve the energy efficiency of your existing home? Energy efficiency saves you money and helps save the environment, so what can you do to improve the energy efficiency of your existing home? Following are a number of things you can do. 1. Deciduous Trees:

More information

Resources for School Energy Managers

Resources for School Energy Managers Resources for School Energy Managers Cooling can present a substantial energy cost to schools. Temperatures of 24 to 27 C with less than 60% relative humidity give acceptable comfort in summer. Higher

More information

Small-Scale Solar Heating and Cooling Systems

Small-Scale Solar Heating and Cooling Systems Contact Austria: AEE INTEC (www.aee-intec.at) France: Tecsol (www.tecsol.fr) Germany: Fraunhofer ISE (www.ise.fraunhofer.de) Greece: CRES (www.cres.gr) Italy: EURAC (www.eurac.edu) University of Bergamo

More information

APPLICATION OF THE ANALYTIC HIERARCHY PROCESS (AHP) FOR ENERGETIC REHABILITATION OF HISTORICAL BUILDINGS. Elena Gigliarelli

APPLICATION OF THE ANALYTIC HIERARCHY PROCESS (AHP) FOR ENERGETIC REHABILITATION OF HISTORICAL BUILDINGS. Elena Gigliarelli APPLICATION OF THE ANALYTIC HIERARCHY PROCESS (AHP) FOR ENERGETIC REHABILITATION OF HISTORICAL BUILDINGS Elena Gigliarelli Institute for Technologies Applied to Cultural Heritage (ITABC) Built Heritage

More information

Exploring the Building Energy Impacts of Green Roof Design Decisions - A Modeling Study of Buildings in 4 Distinct Climates

Exploring the Building Energy Impacts of Green Roof Design Decisions - A Modeling Study of Buildings in 4 Distinct Climates Final version for publication: Exploring the Building Energy Impacts of Green Roof Design Decisions - A Modeling Study of Buildings in 4 Distinct Climates David J. Sailor 1, Timothy B. Elley 2, and Max

More information

Software Development for Cooling Load Estimation by CLTD Method

Software Development for Cooling Load Estimation by CLTD Method IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) ISSN: 2278-1684Volume 3, Issue 6 (Nov. - Dec. 2012), PP 01-06 Software Development for Cooling Load Estimation by CLTD Method Tousif Ahmed Department

More information

3-D Modeller Rendered Visualisations

3-D Modeller Rendered Visualisations Recognised energy Dynamic Simulation Modelling (DSM) software DesignBuilder is a user interface to the EnergyPlus DSM. EnergyPlus builds on the most popular features and capabilities of BLAST and DOE-2

More information

Water & Climate Review

Water & Climate Review Water & Climate Review 1. The cross section below shows the direction of air flowing over a mountain. Points A and B are at the same elevation on opposite sides of the mountain. 4. The graph below shows

More information

DISTRIBUTED GENERATION AND ENERGY EFFICIENCY FOR ACHIEVING ENERGY SELF-SUSTAINING INDUSTRIAL AREAS

DISTRIBUTED GENERATION AND ENERGY EFFICIENCY FOR ACHIEVING ENERGY SELF-SUSTAINING INDUSTRIAL AREAS DISTRIBUTED GENERATION AND ENERGY EFFICIENCY FOR ACHIEVING ENERGY SELF-SUSTAINING INDUSTRIAL AREAS Ing. Maria-Anna Segreto LAERTE Laboratory - 1 EUROPEAN DIRECTIVE 2010/31/UE It 's well known that higher

More information

The built environment : a policy framework for climate adaptation

The built environment : a policy framework for climate adaptation The built environment : a policy framework for climate adaptation The Hon. Tom Roper President, Australian Sustainable Built Environment Council Board Member, Climate Institute Thriving Neighbourhoods

More information

Long-Term Hygrothermal Performance of Green Roofs

Long-Term Hygrothermal Performance of Green Roofs Long-Term Hygrothermal Performance of Green Roofs D. Zirkelbach B. Schafaczek H. Künzel, PhD Member ASHRAE ABSTRACT Green roofs are becoming more and more popular because their thermal inertia, combined

More information

GIS-Based and computer simulation evaluation on. campus master plan

GIS-Based and computer simulation evaluation on. campus master plan 2nd PALENC Conference and 28th AIVC Conference on Building Low Energy Cooling and 1121 GIS-Based and computer simulation evaluation on. campus master plan N. H. Wong, S. K. Jusuf National University of

More information

Course Curriculum for Master Degree in Architecture

Course Curriculum for Master Degree in Architecture Course Curriculum for Master Degree in Architecture The Master Degree in Architecture is awarded by the Faculty of Graduate Studies at Jordan University of Science and Technology (JUST) upon the fulfillment

More information

Eni Green Data Center - Specification

Eni Green Data Center - Specification Eni Green Data Center - Specification Green IT Adopting the principles of sustainable development is one of the key missions in the field of information technology today. 2% of the world s CO2 emissions

More information

Yijun Gao, Wei Wu, Zongwei Han, Xianting Li *

Yijun Gao, Wei Wu, Zongwei Han, Xianting Li * Study on the performance of air conditioning system combining heat pipe and vapor compression based on ground source energy-bus for commercial buildings in north China Yijun Gao, Wei Wu, Zongwei Han, Xianting

More information

Building Energy Labels: The Swiss MINERGIE Label

Building Energy Labels: The Swiss MINERGIE Label Building Energy Labels: The Swiss MINERGIE Label Chennai, October 8 th, 2010 Heinrich Gugerli, Head Sustainable Building Group heinrich.gugerli@zuerich.ch www.stadt-zuerich.ch/nachhaltiges-bauen Energy

More information

The city of Malmö, Sweden

The city of Malmö, Sweden The city of Malmö, Sweden 1. Introduction Malmö is a municipality of 280 000 inhabitants located in Southern Sweden. It is the third largest city in Sweden. It developed from a garrison town in the late

More information

Crawl space heat and moisture behaviour

Crawl space heat and moisture behaviour Crawl space heat and moisture behaviour Miimu Airaksinen, Dr., Technical Research Centre of Finland, VTT miimu.airaksinen@vtt.fi, www.vtt.fi KEYWORDS: crawl space, moisture, evaporation from ground, ground

More information

Residential Windows, 3 rd edition Corrected index 1

Residential Windows, 3 rd edition Corrected index 1 Residential Windows, 3 rd edition Corrected index 1 A absorptance definition, 78 determinants of, 78 79 energy performance and, 78 tinted glass, 84 acoustical properties of windows, 60 61 acrylic glazing

More information

klimatanpassad urban design Erik Johansson Boende och Bostadsutveckling

klimatanpassad urban design Erik Johansson Boende och Bostadsutveckling Urbant Uba klimat at& klimatanpassad urban design Erik Johansson Boende och Bostadsutveckling Urbant klimat & klimatanpassad urban design Urbant klimat Temperatur Vind Exempel Fez (Marocko) Colombo (Sri

More information

Climotion ensures a better climate. Better comfort and lower costs in all buildings. Bosch Energy and Building Solutions

Climotion ensures a better climate. Better comfort and lower costs in all buildings. Bosch Energy and Building Solutions Climotion ensures a better climate. Better comfort and lower costs in all buildings. Bosch Energy and Building Solutions 2 Smart control Smart control 3 Savings have seldom felt so good. Comfort Sustainability

More information

4.4 ECOCITY Tampere - Vuores

4.4 ECOCITY Tampere - Vuores 4.4 ECOCITY Tampere - Vuores Figure 4.4.1 Location of the Vuores area 4.4.1 General information The Vuores case area is a typical greenfield development in a woodland area to the south of the city of Tampere.

More information

Green Architecture and Construction

Green Architecture and Construction Green Architecture and Construction Prof. Dr. Soontorn Boonyatikarn Center of Excellence Building and Environmental Technology, Department of Architecture, School of Architecture, Chulalongkorn University,

More information

High Performance School Buildings Resource and Strategy Guide

High Performance School Buildings Resource and Strategy Guide High Performance School Buildings Resource and Strategy Guide Published by: Sustainable Buildings Industry Council With support from: California Energy Commission National Concrete Masonry Association

More information

DISCOVERY HALL, UNIVERSITY OF WASHINGTON BOTHELL Bothell, Washington 78,200 sf

DISCOVERY HALL, UNIVERSITY OF WASHINGTON BOTHELL Bothell, Washington 78,200 sf DISCOVERY HALL, UNIVERSITY OF WASHINGTON BOTHELL Bothell, Washington 78,200 sf Discovery Hall reflects its dynamic program and dramatic site, as well as the collaborative and student-centered spirit of

More information

SENSITIVITY STUDY FOR ARCHITECTURAL DESIGN STRATEGIES OF OFFICE BUILDINGS IN CENTRAL CHILE: EFFECTIVENESS OF NOCTURNAL VENTILATION.

SENSITIVITY STUDY FOR ARCHITECTURAL DESIGN STRATEGIES OF OFFICE BUILDINGS IN CENTRAL CHILE: EFFECTIVENESS OF NOCTURNAL VENTILATION. SENSITIVITY STUDY FOR ARCHITECTURAL DESIGN STRATEGIES OF OFFICE BUILDINGS IN CENTRAL CHILE: EFFECTIVENESS OF NOCTURNAL VENTILATION. Waldo Bustamante *1, Felipe Encinas 2 and Francisco Sánchez de la Flor

More information

THERMAL INSULATION PERFORMANCE OF GREEN ROOF SYSTEMS

THERMAL INSULATION PERFORMANCE OF GREEN ROOF SYSTEMS IGEC-VI 2011 076 THERMAL INSULATION PERFORMANCE OF GREEN ROOF SYSTEMS Serdar Celik 1, Susan Morgan 2, William Retzlaff 3 and Orcun Once 4 1 Mechanical Engineering, Southern Illinois University Edwardsville,

More information

RosevilleProject. LoE _ 2 Glass Products. You can reduce your cooling energy usage by 25% or more. Here is the proof.

RosevilleProject. LoE _ 2 Glass Products. You can reduce your cooling energy usage by 25% or more. Here is the proof. RosevilleProject Glass Products You can reduce your cooling energy usage by 25% or more. Here is the proof. Hot-Button Issues Residents of California, Arizona, and Nevada don t need a weather forecast

More information