crm+25/d/tc/e Extract from our online catalogue: Current to: 2015-10-26



Similar documents
crm+130/iu/tc/e Extract from our online catalogue: Current to:

How To Make An Ultrasonic Sensor

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Electronic Pressure Switch EDS 300

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

BOS 73K... BOS 74K...

Instruction Manual Service Program ULTRA-PROG-IR

Inductive sensor NI10-M18-Y1X-H1141

96 Variants. The GlobalProx range increases in popularity. 12 PNP Normally-open 12 PNP Normally-closed 12 NPN Normally-open 12 NPN Normally-closed

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

photoelectric highlights

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Inductive Proximity Sensors

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Technical Data. Dimensions

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

Electric Rotary Actuator - On/Off or programmable control actuator

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Technical Data. Dimensions

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Digital display DA 48

USB-500 Series Stand-Alone, Low-Cost Data Loggers

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

W150: Miniature photoelectric switch series with completely integrated electronics

Combi switchbox with integrated 3/2 way pilot valve

intelligent solutions

- 1 - Eddy Current. Eddy current distance and displacement transducer

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Proportional pressure regulators VPPE

Multifunction devices

How To Use A Flowmeter

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Magnetic proximity switches

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Innovation for cost reduction in pneumatics. Leakage monitoring. Measurement of compressed air consumption.

Conductive Level Switch FK 2 Technical Data:

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Cable Plug acc. to DIN EN , Form A

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

New XUY roller sensors

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Turbine Flow Sensor Series VTR

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

Electronic Pressure Switch EDS 3000

Cross-beam scanning system to detect slim objects. 100 mm in

Introduction to Fiber Optic Cables. Photoelectric Sensors. 2Photoelectric Sensors, Standard Sensors, Fiber optic cables. Please Note!

Wind Sensor W-RS485 with RS485 Interface

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards.

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Inductive sensors. Compact, fast, reliable. Edition 2013

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Electrical connection

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

MIN Q SERIES MICRO-PROXIMITY SENSOR DC 3-WIRE TYPE

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

LUT Luminescence scanners: Seeing what no-one else can

Contents. Document information

SELECT MOUNT MONITOR

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

PRODUCT PROFILE FEATURES

W 160: Miniature series for optimum solutions

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

L4940 series VERY LOW DROP 1.5 A REGULATORS

MP85 / MP85DP. Data sheet. Special features MP85 / MP85DP. B en

FACTORY AUTOMATION INTELLIGENT CLAMP MONITORING FOR MACHINE TOOL SPINDLES WITH INDUCTIVE POSITIONING SYSTEMS

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Application book Material Handling: forklifts. Inductive Sensors. Proximity Sensor

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

ONLINE DATA SHEET. Contrast sensors KTM KTM-WP11181P

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Transcription:

Extract from our online catalogue: crm+25/d/tc/e Current to: 2015-10-26 microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E info@microsonic.de microsonic is a registered trademark of microsonic GmbH. All rights reserved.

Wear-resistant PEEK film protects the sensor membrane from chemicals, contamination and caking. Highlights Ultrasonic transducer protected by PEEK film ::: for simple cleaning and high resistance to wear Stainless-steel housing Digital display with direct measured value output in mm/cm or % Numeric configuration of the sensor using digital display ::: permits the complete advance configuration of the sensor Automatic synchronisation and multiplex operation ::: for simultaneous operation of up to ten sensors in close quarters Basics 1 or 2 switching outputs in pnp variant Analogue output 4 20 ma and 0 10 V ::: with automatic switching between current and voltage outputs 5 detection ranges with a measurement range of 30 mm to 8 m microsonic Teach-in using T1 or T2 buttons 0.025 mm to 2.4 mm resolution Temperature compensation 9 30 V operating voltage LinkControl ::: for configuration of sensors from a PC

Description Sensor membrane with wear-resistant protective film In many filling processes, spray on the sensor membrane simply cannot be avoided. These sprays often harden so that after longer periods of operation contamination can only be removed from the sensor membrane by mechanical means. The new protective film of the crm+ sensors now makes it easy to remove caked-on soiling, such as hardened casting compound and cement spatter. The protective film is also highly resistant to corrosive media. The threaded sleeve is made of 1.4571 stainless steel. TouchControl with LED display - Wear-resistant PEEK protective film There are three output stages available for all five detection ranges: The crm+ sensors with switching output have three operating modes: Single switching point Two-way reflective barrier Window mode With TouchControl all configuration can be done right at the sensor. The easily legible three-digit LED display continually shows the current distance value and automatically switches between millimetre and centimetre displays. Setting a switching or analogue output can optionally be carried out by numeric input of the desired distance values, or using a teach-in procedure. This permits the user to select the configuration method preferred. The crm+ sensors support synchronisation and multiplex operation and have extensive parameterisation options via LinkControl. For detailed information, please see at mic+ sensors. LinkControl consists of the LinkControl adapter and the LinkControl software and facilitates the configuration of the crm+ sensors via

a PC or laptop with any conventional Windows operating system. Sensor connected to the PC via LCA-2 for programming

crm+25/d/tc/e scale drawing detection zone 1 x pnp 350 mm operating range design operating mode particularities ultrasonic -specific means of measurement transducer frequency blind zone operating range maximum range angle of beam spread resolution/sampling rate 30-250 mm cylindrical M30 proximity switch/reflective mode reflective barrier window mode high chemical resistance stainless steel version display echo propagation time measurement 320 khz 30 mm 250 mm 350 mm please see graphics detection zone 0.025 mm reproducibility ± 0.15 % accuracy electrical data operating voltage U B voltage ripple ± 10 % no-load current consumption type of connection ± 1 % (temperature drift internally compensated) 9-30 V d.c., reverse polarity protection 80 ma 5 pin M12 initiator plug

crm+25/d/tc/e outputs output 1 switching hysteresis switching frequency response time delay prior to availability inputs input 1 housing material ultrasonic transducer switching output pnp: I max = 200 ma (U B 2V) NOC/NCC adjustable, short circuit proof 3 mm 25 Hz 32 ms < 300 ms class of protection to EN 60529 IP 67 operating temperature storage temperature weight technical features/characteristics temperature compensation controls scope for settings synchronization multiplex indicators particularities documentation (download) pin assignment com input synchronisation input stainless steel, plastic parts: PBT, TPU coated with PEEK film, PTFE O ring 25 C to +70 C 40 C to +85 C 110 g yes 2 push buttons + LED display (TouchControl) Teach in and numeric configuration via TouchControl LCA 2 with LinkControl yes yes 3 digit LED display, 2 x three colour LED high chemical resistance stainless steel version display