AN-2 TEN KEY CONSIDERATIONS BEFORE YOU START YOUR DAA OR FXO PHONE LINE INTERFACE DESIGN



Similar documents
AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN

AN-4 (Midcom TN #98) LOW COST TELEPHONE LINE INTERFACE (DAA, FXO)

2-Wire/4-Wire Telephone Line Interface. XE0204 Block Diagram

AN-6 COMMON MISTAKES IN LIGHTNING PROTECTION OF PHONE LINE INTERFACE CIRCUITS

Miniature Surface-Mount DAA for Audio or Data Transfer XE0402LCC BLOCK DIAGRAM

PATTON TECH NOTES What are FXS and FXO?

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

Nexus Technology Review -- Exhibit A

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Tech Note. Introduction. Definitions. What are FXS and FXO?

Rack mounted telephone- and leased line modem for industrial applications

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Customer Interface Publication: KCH CIP002. Public Switched Telephone Network (PSTN)

30 In Compliance October

A series of technology briefs spanning Tyco Electronics product portfolio

MINIMUM QUALITY INDICATORS FOR ALL TYPES OF LEASED LINES

Grounding Demystified

Understanding the realities of T.38 compliance

Telecommunication Line Protectors

How To Use A 1232 On A 1236 On A Computer Or A Cell Phone

The W5JCK Guide to the Mathematic Equations Required for the Amateur Extra Class Exam

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

USER GUIDE. 2 Channel POTS Mux DIN Fiber Link System. Introduction SYSTEM INSTALLATION INFORMATION. The leader in rugged fiber optic technology.

1.3. The network element must have the ability to be configured in a point to point, point to multi point, and daisy chain configuration.

EECC694 - Shaaban. Transmission Channel

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

White Paper: Electrical Ground Rules

Troubleshooting accelerometer installations

Frequently Asked Questions

Data Transmission. Data Communications Model. CSE 3461 / 5461: Computer Networking & Internet Technologies. Presentation B

)454 6 %LECTRICAL CHARACTERISTICS FOR BALANCED DOUBLECURRENT INTERCHANGE CIRCUITS OPERATING AT DATA SIGNALLING RATES UP TO -BITS

Public Switched Telephone System

IEEE P802.3af DTE Power via MDI Task Force Presentation Phil Holland

Tenor AF MultiPath Switch

Internet Telephony Terminology

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Overview of the Telecommunications Network

Signal Types and Terminations

Reading: HH Sections , (pgs , )

ATA: An Analogue Telephone Adapter is used to connect a standard telephone to a high-speed modem to facilitate VoIP and/or calls over the Internet.

USER GUIDE. 2-Wire Analog Phone System 4RU Plug-in Card. Description. Single Channel Analog Phone over Fiber

FREQUENCY RESPONSE ANALYZERS

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages

Next Generation of High Speed. Modems8

How To Use A U.S. Cell Phone At Home

TECHNICAL SPECIFICATION FOR PRIVATE AUTOMATIC BRANCH EXCHANGE (PABX) SYSTEM FOR CONNECTION TO PUBLIC SWITCHED TELEPHONE NETWORK (PSTN)

TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

In the idle state, the TIP lead will be high impedance to ground and the RING lead will have the battery voltage. See Figure 1.

Understanding SMD Power Inductors. Application Note. July 2011

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

EMC Basics. Speaker : Alain Lafuente. Alain.lafuente@we-online.com

Power Supplies 3. SDN-P DIN Rail Series

Cable Discharge Event

Application Note TMA Series

Implementing a Digital Answering Machine with a High-Speed 8-Bit Microcontroller

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

ADSL or Asymmetric Digital Subscriber Line. Backbone. Bandwidth. Bit. Bits Per Second or bps

Installation Manual for D0700 ISDN Analogue Converter

Contents. 2 NP560-NP562 Installation Guide YML821 Rev1

Current Loop Application Note 1495

Current Probes. User Manual

GSM Voice Auto Dialer & SMS Sender JC-999

VJ 6040 Mobile Digital TV UHF Antenna Evaluation Board

Operating Manual UWAPS-TINY Series

T1 Networking Made Easy

FOM-5A, 6A. Asynchronous Fiber Optic Modem

Security Auto Dialer. Owner s Manual. Please read before using this equipment.

ETSI TR V1.2.1 ( )

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Configuring the 930A for Common PBX Metallic Signaling Interfaces

EMI in Electric Vehicles

TECHNICAL TBR 12 BASIS for December 1993 REGULATION

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

47000 SERIES - ELECTRONIC TRANSFORMERS

High Voltage Power Supplies for Analytical Instrumentation

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

UltraFED IIB. 30 MHz Far-End Device

Chapter 9 Using Telephone and Cable Networks for Data Transmission

Telephone- and leased line modem for industrial applications TD-36

LVDS Technology Solves Typical EMI Problems Associated with Cell Phone Cameras and Displays

Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015

CISCO SPA3102 PHONE ADAPTER WITH ROUTER

Reducing EMI and Improving Signal Integrity Using Spread Spectrum Clocking

NXU RoIP Link to Eliminate Voice-Grade Leased Line

OM2260VW2 USER MANUAL VERIZON WIRELESS HOME PHONE CONNECT

Administrative Council for Terminal Attachments (ACTA) Customer Information

AVX EMI SOLUTIONS Ron Demcko, Fellow of AVX Corporation Chris Mello, Principal Engineer, AVX Corporation Brian Ward, Business Manager, AVX Corporation

VOLTAGE REGULATOR AND PARALLEL OPERATION

FM Radio Transmitter & Receiver Modules

Operation Manual Voice Overview (Voice Volume) Table of Contents

TECHNICAL SPECIFICATION FOR CORDLESS TELEPHONE SYSTEMS

Transcription:

AN-2 TEN KEY CONSIDERATIONS BEFORE YOU START YOUR DAA OR FXO PHONE LINE INTERFACE DESIGN By Joe Randolph Introduction The conventional 2-wire analog phone line that telephone companies provide to residential and business customers is commonly called POTS (Plain Old Telephone Service). Common examples of POTS equipment include telephones, modems, fax machines, set top boxes, and alarm dialers. This same basic type of phone line is used by certain types of business telephone systems and for interfaces between VOIP (Voice Over Internet Protocol) equipment and the PSTN (Public Switched Telephone Network). When used for a modem, the phone line interface in the terminal equipment is typically called a DAA (Data Access Arrangement). For voice applications, the interface is typically called an FXO interface (Foreign Exchange Office). For the purposes of this article, we will use the term DAA-FXO interface. While the basic functionality of the DAA-FXO interface is common to all the above product types, there are important differences that depend on the target application. This article summarizes some of the key considerations that should be taken into account when designing a DAA-FXO phone line interface. 1) Will the interface be used for data, voice, or both? Voice applications require the ability to transmit a higher peak-to-peak signal than data modems. This is because human speech has higher short term peaks than the comparatively constant levels associated with data modems. The PSTN is designed to handle speech signals up to 3.1 volts peak to peak, corresponding to the peaks of a +3 dbm sine wave. For optimal performance on the PSTN, voice equipment should be able to transmit without distortion at these levels. In some cases there are regulatory requirements or industry specifications where the ability to transmit at +3 dbm is a requirement. Data modems do not typically generate such high peak transmit levels. In general, a high speed data modem only requires the ability to transmit at about 1.5 volts peak to peak, corresponding to a -3 dbm sine wave. Low speed data modems require even less transmit signal swing. It should be noted that phone line interfaces typically have the greatest difficulty transmitting at high levels when the DC loop current in the phone line is low. Operation at loop currents down to 18 ma is typically required. For some types of DAA-FXO circuits, it can be very difficult to transmit a +3 dbm sine wave when operating on only 18 ma of loop current. 1

Another key difference between voice and data applications is the AC impedance that the interface must present to the phone line. This is typically measured indirectly as return loss with respect to a specified impedance. Most data modems are designed to match a simple 600 ohm resistance, and this impedance is acceptable for data modems in every country except Australia. Voice products are often required to match a complex reference impedance that includes a capacitive element. Many countries that accept 600 ohms for data modems impose a complex reference impedance for voice products. In Australia, both modems and voice products must match a complex reference impedance. 2) If the application is a modem, what speed is the modem? There are many different types of modems, and the performance requirements for the line interface vary significantly for the different types. High speed, full duplex data modems in the 14.4 K to 56 K range such as ITU standards V.32bis, V.34, and V.90 typically require lower distortion, lower noise, and higher bandwidth in the line interface than what is required for low speed modems. Failure to take distortion, noise, and bandwidth into account can lead to serious performance limitations. Low speed modems in the 300 bps to 2400 bps range such as ITU Standards V.21, V.22, and V.22bis are much less sensitive to the distortion and bandwidth of the line interface. If an application does not require high speed data communication, the use of a low speed modem may save some cost in the line interface and may also improve the reliability of the data connection. Fax modems are a special case that deserves mention. The high speed image transfer portion of the fax protocol is half duplex, which means that it passes data in only one direction at a time, as opposed to the typical full duplex data modem that transmits and receives data simultaneously. The only full duplex portion of the fax protocol takes place at low speeds in the range of 300 to 2400 bps. The net result is that fax modems, even if they use high speed image transfer in the 14.4 K to 33.6 K range of the ITU V.17 and V.34bis standards, are much less sensitive to noise and distortion than full duplex data modems. This provides some opportunity for cost savings in the line interface design. 3) What are the size constraints for the interface? Sometimes the least expensive or best performing DAA-FXO line interface will be transformer based, but transformer-based designs are typically larger than solid state designs. Through the use of specially designed miniature transformers, a transformer-based design can be made quite small, using about one square inch of circuit board area. However, for the absolute smallest implementation, the various silicon DAA-FXO chip sets from vendors such as Clare, Integration Associates, Silicon Labs, and Teridian will usually require less board space than a comparable transformer-based version. There can be some performance tradeoffs when using a silicon DAA-FXO, so if adequate space is available a transformer-based version should be considered. 4) In what countries must the interface be approved? The target countries where a product will be sold are an important consideration. The process of gaining regulatory approval for selling the product in a given country is often called homologation. 2

Various countries impose different (and sometimes conflicting) requirements on the electrical characteristics of a DAA-FXO interface. In the past, there were several conflicting requirements such as ring detection and AC impedance that required a high degree of configurability in a worldwide design, but now there are far fewer of these conflicting requirements. This is especially true since Europe stopped regulating most of these parameters a few years ago. Today, a carefully designed DAA-FXO circuit can be used in most countries worldwide with few, if any, configurable parameters. While compliance with most of the basic electrical characteristics is now greatly simplified, there has been a recent trend of increasingly difficult international requirements for EMC (Electro-Magnetic Compatibility). The EMC requirements can include limits not only on radiated and conducted RF emissions, but also on the equipment s susceptibility to interference from radiated and conducted RF in the environment. In particular, immunity to conducted RF noise on the phone line can be a difficult requirement to meet. Countries where such immunity is now a regulatory requirement include Europe, Brazil, Mexico, India, and South Korea. Several countries require that the line interface must not be damaged when subjected to specified lightning surges. The requirements in Taiwan and South Africa are particularly severe. In Brazil, the line interface must not be damaged by specified power induction events that simulate 60 Hz AC power appearing on the phone line. In summary, it is helpful to know at the outset of your design the countries where you intend to eventually seek regulatory approval. If the worst-case requirements are accounted for in the initial design phase, there will be less likelihood of requiring major redesigns to gain regulatory approval in any given country. These days, the applicable EMC requirements typically require more attention than they have in the past. 5) Do any industry requirements apply? It is important to know who your customers will be. If a product will be sold directly to consumers in retail outlets, perhaps the only requirements that absolutely must be met are those required by local law, such as the applicable regulatory requirements for safety, EMC, and network compatibility. However, even for consumer products, if your customer is a large retail chain or reseller, the customer may impose additional industry requirements as part of their purchase specification. Industry standards such as ETSI TBR 21 and ES 203 021, EIA-470, and ITU K.20 and K.21 are not legally required for regulatory compliance, but they are often imposed by the customer as part of a purchase specification. Similarly, if your product will be used by a network provider, there will typically be significant additional requirements imposed by the customer to ensure adequate reliability in the field. In North America, Telcordia NEBS GR-1089-CORE imposes some of the most stringent lightning and power cross immunity requirements in the world. Compliance with this industry standard is typically required by all of the PSTN network operators in North America. 6) Will the interface ever have another device connected in parallel? Some DAA-FXO interfaces are more sensitive than others to the available DC voltage and current on the phone line. In general, modems do not have to operate with another device offhook (active) on the phone line at the same time, so they can use 100% of the available power on the phone line. On the other hand, many voice products such as telephones have to continue to operate normally when 3

another phone is offhook on the line at the same time. This means that the two terminal devices must share the available power. Some types of DAA-FXO interface handle this condition better than others. 7) Is Caller ID detection required? If the product must be able to detect caller ID signals, this will have an effect on the design of the interface and the available choices. Since caller ID does not operate the same way in every country, the list of countries where the product will be sold must be considered as well. 8) Is any type of line status sensing required? Some applications, such as set top boxes, share the household phone line. Often it is desirable for these devices to avoid placing automatic calls when the phone line is already in use. Also, for emergency calls that might need to be placed from a household phone, it can be helpful for the automatic calling device to terminate any call that it has in progress if a parallel phone goes offhook. Some DAA-FXO circuits can provide these types of line status sensing quite readily, while others can not. 9) Is lightning immunity a major concern? In some cases it can be helpful to self-impose a lightning immunity requirement that exceeds what would normally be required by the applicable regulatory requirements. The vast majority of lightning surges that appear on phone line interfaces have open-circuit voltages of less than 1500 volts and short-circuit currents under 50 amps, and most DAA-FXO circuits can handle these surges reasonably well. Unfortunately, due to various conditions in the network, a very small percentage of terminal devices will be subjected to surges that have open-circuit voltages up to 5000 volts and short-circuit currents up to 100 amps. For products that are sold in low to moderate volumes, or products where field reliability is not critical, it may be acceptable to have a small percentage of installed units fail due to lightning damage. However, for products sold in large volumes or products used in critical applications, even a small percentage of the installed units failing from lightning damage can present serious problems. For a set top box that has 10 million units installed in the field, even a failure rate of only 0.1% per year translates to 10,000 lightning failures per year. For such applications, designing a more rugged DAA-FXO interface can provide significant benefits regarding warranty repair costs, field repair costs, and customer satisfaction. 10) Are there specific requirements for power consumption? Applications that are battery powered may place constraints on the active power consumption of the DAA-FXO interface, or require special power-down modes when the interface is idle. For applications 4

that are powered from the AC mains, power consumption in the DAA-FXO interface is typically not an issue. Summary Despite the fact that DAA and FXO phone line interface circuits perform essentially the same basic functions, there can be significant differences in the requirements that apply for a specific application. To minimize the chances of major schedule delays or expensive redesigns, it is helpful to consider these differences at the outset of the design process. About the Author Joe Randolph is an engineering consultant who has been designing phone line interfaces for over 20 years. He has completed designs for compliance with every major international standard, and has experience with all types of DAA and FXO line interface technology, including transformer, optical, and capacitive isolation circuits. His contact information is: Joe Randolph Randolph Telecom, Inc. Phone: 781-721-2848 (USA) Email: jpr@randolph-telecom.com Web Site: http://www.randolph-telecom.com 5