amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS



Similar documents
Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

AxION edoor. Web-Based, Open-Access Mass Spectrometry Software

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow

Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS

WATERS QUANTITATIVE ANALYSIS solutions

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

aurora ICP-MS Innovation with Integrity The Science of Sensitivity ICP-MS

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report

Waters Core Chromatography Training (2 Days)

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Appendix 5 Overview of requirements in English

ProteinScape. Innovation with Integrity. Proteomics Data Analysis & Management. Mass Spectrometry

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Pesticide Analysis by Mass Spectrometry

SCION SQ Series GC-MS

LC-MS/MS for Chromatographers

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Thermo Scientific ExactFinder Software

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics

Introduction. What Can an Offline Desktop Processing Tool Provide for a Chemist?

How To Build An Amd Quas 3 Ar Mass Spectrometer

impact II Innovation with Integrity Get the full picture the first time UHR-TOF MS

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

AMD Analysis & Technology AG

aurora M90 Innovation with Integrity A new era in ICP-MS ICP-MS

Electron Transfer Dissociation (ETD) Innovation with Integrity. Look Beneath the Surface. Ion Trap MS

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

NUVISAN Pharma Services

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Application Note # MS-14 Fast On-site Identification of Drugs with the mobile GC/MS system E²M

MassHunter for Agilent GC/MS & GC/MS/MS

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

B i o s o l u t i o n s

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

AutoSpec Premier. Are you? Analyzing dioxins and related compounds? Required to satisfy regulatory requirements?

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

Eleanor Riches Waters Corporation, Manchester, UK INTRODUCTION

Analyzing Small Molecules by EI and GC-MS. July 2014

SimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data

using ms based proteomics

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

A Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015

泛 用 蛋 白 質 體 學 之 質 譜 儀 資 料 分 析 平 台 的 建 立 與 應 用 Universal Mass Spectrometry Data Analysis Platform for Quantitative and Qualitative Proteomics

Accelerate your Quantitative LC/MS Workflows with a Fully Integrated UHPLC-QQQ Platform

is a knowledge based expert decision support tool for predicting the metabolic fate of chemicals in mammals.

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

Agilent LCMS products and the application strategies in veterinary drug analysis

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

RAPID MARKER IDENTIFICATION AND CHARACTERISATION OF ESSENTIAL OILS USING A CHEMOMETRIC APROACH

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

Thermo Scientific Compound Discoverer Software. A New Generation. of integrated solutions for small molecule structure ID

Micromass LCT User s Guide

Electrospray Ion Trap Mass Spectrometry. Introduction

L. Yu et al. Correspondence to: Q. Zhang

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

Application of Structure-Based LC/MS Database Management for Forensic Analysis

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Mass Frontier Version 7.0

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

13C NMR Spectroscopy

SimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data

Mass Frontier 7.0 Quick Start Guide

C146-E087F. GCMS-QP2010 Plus. Shimadzu Gas Chromatograph Mass Spectrometer

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Application Note # LCMS-66 Straightforward N-glycopeptide analysis combining fast ion trap data acquisition with new ProteinScape functionalities

New drugs of abuse? A case study on Phenazepam & Methoxetamine

Research-grade Targeted Proteomics Assay Development: PRMs for PTM Studies with Skyline or, How I learned to ditch the triple quad and love the QE

High Resolution LC-MS Data Output and Analysis

Transcription:

amazon SL Setting New Standards in Performance, Simplicity and Value Innovation with Integrity Ion Trap

Best-In-Class Ion Trap Mass Spectrometer for Routine Analysis The amazon SL entry-level system is based on Bruker s advanced amazon ion trap series and delivers best-inclass analytical performance, enhanced productivity and efficiency all tailored to your needs. Together with high sensitivity thanks to proprietary Dual Ion Funnel technology and fast data acquisition at high scan speeds and mass resolution, this ion trap delivers uncompromised LC/ n data quality and flexibility at an affordable price. Bringing innovative trap technology within the reach of every analytical lab The amazon SL sets a new standard in ion trap excellence, making highquality and high-confidence chemical analysis affordable for any analytical lab. By enabling rapid and sensitive identification, characterization and structural confirmation of compounds, the amazon SL is the robust, all-purpose solution to a wide variety of chemical, environmental, metabolic or forensic challenges: General LC// chemical analysis Chemical structure confirmation by n Screening applications with fast polarity switching and / library searching Quality control, synthesis control and process development Metabolite ID & profiling Copolymer analysis by GPC-/ technology

Ease of Use and / spectra of a mixture of peptides. The enhanced resolution scan provides fully resolved peaks up to a charge state of 4+. The observed mass accuracy for the precursor ion at m/z 81 and the fragment ion at m/z 736 is absolutely unrivalled for ion trap instruments. A continuous Auto n experiment over a period of 24 h demonstrate the excellent robustness of the instrument with regard to an extremely stable mass position of the detected ions. Robustness [%] 3+ 349.52 1 8 3+ 2+ 6 433.23 2+ 5+ 81.42 524.28 4 63.69 2 2 3 4 5 6 7 8 9 m/z 2+ 3+ 4+ / 81.42 81.42 587.32 324.93 736.41 456.27 2 4 6 8 1 m/z mass position / mda mass possition/mda / 15 1 5-5 -1-15 15 1 5-5 -1 24 hour continuous Auto n -15 2 4 6 811214161822224 Performance and reliability The amazon SL stands for excellent performance and reliable, robust operation. and n data sets deliver high sensitivity, resolution of multiply charged ions and class-leading, confident mass assignment. Simple and flexible quality & synthesis control The flexible APCI source also offers the possibility to work with the direct injection probe (DIP) for the analysis of solid samples. This enables a fast and direct identification of compounds from organic syntheses, process development, etc. Sensitivity 6 x 25 fg S/N > 5:1 6 x 1. pg 6 x 2.5 pg 1 15 2 25 3 Time [min] / sensitivity for multiple injections of reserpine. S/N ratios > 5:1 are reproducibly obtained using 25 fg column loads. TIC 263.3 N N 246.6 Solid Samples The direct probe ion source allows the straightforward analysis of liquid and solid samples without tedious sample preparation. The example shows the unambiguous identification of a synthetic compound using 3. The information provided by 2 alone is not sufficient due to non-specific water loss. Samples were kindly provided by SiChem GmbH, Bremen, Germany. 2.5 3. 3.5 4. Time [min] 3 2 216.6 246.5 231.4 173.2 188.4 144. 159.99 23.3 12 14 16 18 2 22 24 26 m/z

Compound Screening & ID n for structural elucidation and compound screening Elucidation of glycan structures Single fragmentation pathways in n steps allow observation of side-chain losses and enable verification or even de-novo elucidation of molecular structures. Compounds can easily be screened and identified by comparing results with reference spectra stored in n libraries. Pent Dig 93.6 195.7 1227.7 2 69.4 771.5 [-H 2 -H] - 161. 3 Robustness and ease-of-use make amazon SL perfect for automated QC Compass TM penaccess enables non -experts to run samples or batches using predefined methods 2 4 6 8 1 12 14 m/z n enables characterization of digitonin, a steroid glycoside. The complete glycan structure, down to the initial sugar unit, can be elucidated in consecutive n steps. Chemical synthesis, quality control Myxochelin A (negative ion mode) Myxalamid C (positive ion mode) The amazon SL can be used in an pen-access environment without special training. The LC- walk-up solution allows a true multiuser environment perfectly adapted to the robustness and ease-of-use of the amazon SL. The example above shows the verification of a chemical s presence in a synthesis quality control workflow. The user receives the result as a PDF report. The color-coded 96-well plate image provides a quick overview for every sample in a full batch. x19 4 3 2 1 8 x1 1..8.6.4.2 - / Sample - Ref DK1622 A-X_3-A,1_1_65.d: BPC 1.-1. +All BPC positive mode DK1622 A-X_3-A,1_1_65.d: BPC 1.-1. -All BPC negative mode. 1 2 3 4 5 6 7 Time [s] + / Sample + Ref Quick and reliable identification of natural compounds from myxobacteria by + library search. Sensitive and highly reproducible / data allow direct comparison of experimental + / data with DKxanthen library 544 reference spectra. Fast polarity switching delivers Sample detection of compounds (both polarities) in both ionization modes and ensures that compounds + Ref are not missed. -

Superb Performance United with Simplicity and Reliability Exceptional analytical value Patented Dual Ion Funnel technology delivers superior sensitivity in the low femtogram range Fast data acquisition with scan speeds up to 32, u/s at full isotopic resolution provides high duty cycles ideal for UHPLC coupling SmartFrag algorithm ensures optimal, reproducible fragmentation for / library searches n-the-fly polarity switching (delay < 8 ms) for highly efficient compound / screening Fragmentation up to the 11 stage, enables detailed structural investigation of compounds Flexibility in your daily work The amazon SL is fully integrated into the Bruker Compass software suite, allowing flexible use and full control of a wide variety of HPLC, UPLC and nanolc systems The instrument is fully compatible with any Bruker API source, giving access to multiple ionization methods, such as ESI, APCI, APPI, and nanoesi Reliability and robustness The amazon SL is the latest product of over two decades of Bruker ion trap technology development. Robust, proven ion trap technology combined with the latest hardware controllers makes the amazon SL a reliable long-term partner for daily laboratory work Low maintenance requirements and reliable hardware make the amazon SL ideally suited for open access environments, such as in synthesis control or general QC Simple, intuitive operation modes The SmartLine software suite provides extremely easy and quick access to analytical answers. Smart and intuitive automation routines for calibration, tuning and data post-processing. Simplified GUI Compass penaccess enables use of the amazon SL by multiple, non-expert, walk-up users Turning ideas into successful analyses The outstanding performance of amazon ion trap mass spectrometers is based on and secured by a series of exclusive, patented technologies. Patent Benefit Current amazon-related patents world-wide Dual Ion Funnel Source High Transmission Glass Capillary Non-linear Excitation for Ion Ejection Smart Charge Control Mass-independent ion transfer and sensitivity boost Fast alternating polarity Ultrafast scan rates with unmatched mass resolution ptimization of the charge density inside the ion trap without the need for a time-consuming pre-scan DE 195 23 859 C2; GB 2 32 985 B; US 5,572,35 A; GB 2 42 261 B; US 7,64,321 B2 DE 195 15 271 C2; GB 2 3 295 B; US 5,736,74 A DE 41 42 87 C2; GB 2 263 192 B; US 5,386,113 A; DE 41 42 869 C1; GB 2 263 191 B; US 5,298,746 A DE 43 26 549 C1; GB 2 28 781 B; US 5,559,325 A; DE 197 9 86 B4; GB 2 322 961 B; US 5,936,241 A; DE 1 27 545 C1; GB 2 364 821 B; US 6,6,154 B1

Bruker Daltonics is continually improving its products and reserves the right to change specifications without notice. BDAL 9-214, 1832294 Technical Specifications Superior high-capacity trap using the latest Dual Ion Funnel technology Quadrupole ion trap based on innovative technical design for the highest ion storage capacities Patented SmartICC for optimum ion accumulation control without prescan Mass-independent ion transmission using Dual Ion Funnel technology Standard-setting combination of mass resolution, scan speed and m/z range in and n Fast polarity switching for acquisition of positive- and negative-ion spectra under LC conditions Reproducible spectra for high-confidence / library searches using SmartFrag Scan speed and resolution ( and n ) Scan Mode Res m/z u/sec UltraScan 2 + ions 2,2 32, Enhanced Resolution 4 + ions 2,2 8,1 Extended Mass Range 4, 27, Scan modes Full scan, / and n for the most sensitive and reliable analysis of unknown compounds Neutral loss scan Multiple reaction monitoring (MRM) using / and 3 Manual n up to n = 11 in all scan modes Auto n tree experiments with up to 5 fragment ions per stage Data-dependent experiments All forms of common data-dependent experiments including preferred mass lists for automated feedback experiments from MetaboliteTools are supported. Source options Choice of API sources CaptiveSpray nanobooster for nano LC applications Smart CE- coupling with grounded needle Software options MetaboliteTools TM software for metabolite identification ACD Labs Manager for structural interpretation and classification Compass A/QC: Web-based, guided operation of LC/ systems for walkup users Compass Security Pack for regulated environments Support of HPLC and sample inlet systems from the following vendors: Thermo/Dionex, Agilent, VWR/Hitachi, Waters (incl. UPLC) For research use only. Not for use in diagnostic procedures. Bruker Daltonik GmbH Bremen Germany Phone +49 ()421-225- Fax +49 ()421-225-13 sales@bdal.de Bruker Daltonics Inc. Billerica, MA USA Fremont, CA USA Phone +1 (978) 663-366 Phone +1 (51) 683-43 Fax +1 (978) 667-5993 Fax +1 (51) 687-1217 ms-sales@bdal.com cam-sales@bruker.com www.bruker.com