THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER



Similar documents
CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

CoolTeg Plus Chilled Water (CW) version: AC-TCW

JAWAHARLAL NEHRU UNIVERSITY

EHDC. Cooling system for Data Center and server cabinets.

How to Build a Data Centre Cooling Budget. Ian Cathcart

by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized!

Incubator with mechanical convection

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Automation's Modular Containerized Datacenter Solutions

IPSIP M series-m Modular Data Center

CRAC Precision climate control units for data centres

RiMatrix S Make easy.

Upgrading the PRS datacentres: space requirement. S. S. Mathur, GM-IT, CRIS

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Material test chamber with mechanical convection

How To Use Rittal'S Rizone

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

HUAWEI TECHNOLOGIES CO., LTD. Huawei IDS2000-S Small Modular Data Center Solution

Data Center Components Overview

White Paper Rack climate control in data centres

Phase Modular Finally the benefits of Modular ups are for all

Fujitsu PRIMERGY BX600 S3 Blade Server

2 Rittal Micro Data Centre

Technical specifications. Containerized data centre NTR CDC 40f+

Managing Data Centre Heat Issues

york air-conditioning products Residential & VRF News 2015

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Eaton 93PM UPS Where aesthetics meet intelligence.

Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server

Data Centre Testing and Commissioning

Huawei IDS2000 Modular Data Center Solution

As close to perfection. development and production. Modular data center

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

Choosing Close-Coupled IT Cooling Solutions

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

NAISSUS THERMAL MANAGEMENT SOLUTIONS

Improve competiveness of IDC and enterprise data centers with DCIM

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

How To Make A Fronius Cl Power Inverter

Portable Energy Efficient Data Centre Solution

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Access Control and Operating Conditions Monitoring System for Telecommunication and Server Racks

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

STULZ View On DataCenter Cooling

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution

AIR-CONDITIONER SPLIT TYPE

QuickSpecs. HP IP Console Switches. Overview

IBM Twin Data Center Complex Ehningen Peter John IBM BS 2011 IBM Corporation

Scout 1U Rackmount Computer

Freezers - Ultrafreezers. Platilab & Irilab Series

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Server Room, Data Centre Management and Monitoring Solutions

Huawei IDS1000 Container Data Center Solution

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Refrigeration Compressed Air Dryer Buran Ultrapulse

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Dimensions (HxDxW) Total Cabinet Area 89.96x x 24 in/ 2,285 x 1, x mm 95.47x 48 x 32 in/ 2,425 x 1,219.2 x 812.

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

How To Buy An Fujitsu Primergy Bx400 S1 Blade Server

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Vacuum drying oven for non-flammable solvents

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Blade Server & Data Room Cooling Specialists

Heating oven with mechanical convection

Natural geothermal energy.

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

APC APPLICATION NOTE #92

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

COMPARISON OF EFFICIENCY AND COSTS BETWEEN THREE CONCEPTS FOR DATA-CENTRE HEAT DISSIPATION

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Environmental IT Monitoring for serious professionals Detects all risks instant alerting ingeniously simple

Model #: SMART2200CRMXL

Electronic Control Devices The European Product Catalogue 2007

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.

EXAMPLE OF A DATA CENTRE BUILD

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

Introducing Computational Fluid Dynamics Virtual Facility 6SigmaDC

Compaq Rack Options and Accessories. Monitors and Keyboards

Transcription:

Your Complete Turnkey Server Room Air Condition UPS THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER AVAILABLE IN WATER AND GAS SYSTEM MODEL AIR-CONDITIONED CABINET EXCELLENT TEMPERATURE CONTROL FOR VERY CRITICAL LOADS, INDEPENDENT FROM ENVIROMENTAL CONDITIONS OPTIMIZED SPACE DON T NEED A SPECIALROOM VERY EASY INSTALLATION LOW POWER CONSUMPTION PERFECT ELECTRICAL POWER SUPPLY, STABLE, REDUNDANT, WITH CONTINUITY OF POWER SUPPLY, NOISE-FREE READY FOR FUTURE EXPANSION OF THE COMPUTER SYSTEM

Air Condition UPS Your Complete Turnkey Server Room The modern Data Center needs considerable electrical power, even used to cool the system. The infrastructures have become more and more important and expensive: consider for example the concentration of heat produced by modern blade servers and the dissipation within a limited temperature window, or shortage of open spaces. It s an obligation to optimize space and power consumption. Air Condition UPS is our solution for a small and medium-size Data Center. Air Condition UPS range includes several solutions for the different Data Centers power requirements. From the small Air Condition UPS in a sole cabinet, that is like a small data center room, to the modular Air Condition UPS that is designed to satisfy the most powerfull computers. Air Condition UPS is an air-conditioned cabinet: inside is located the server (and its accessories as hubs, switch boards, etc...), and the redundant modular uninterruptible power systems (UPS) with their sealed batteries. The air conditioner automatically optimizes both the temperature inside the cabinet and the energy consumption. Air Condition UPS Available space for server Electrical distribution Modular UPS Sealed Batteries

Air Condition UPS MODULAR SYSTEM SERVER UPS + BATTE RY SERVER UPS + BATTE RY Available space for server Sealed Batteries Electrical distribution Modular UPS COOLING SYSTEM UNIT The system is made of 3 main units: A. External Refrigerant Unit: can work with water as CSG GAS AS REFRIGERANT (ERG) B. Cabinet with cooling system inside, connected to external refrigerant unit through two pipelines (named CSW if water, or CSG if gas). C. Cabinet that can house UPS, batteries and server or only server named SU. CSW SU COOLING SYSTEM UNIT WATER AS REFRIGERANT (ERW) How the Air Condition UPS system works SU The system is a closed system: the cold air comes out (forced by fans) from the front side of the cooling module: then is sucked in UPS and servers by fans. The hot air comes out from the rear part of UPS and servers, and is sucked in the cooling system. A special membrane parts the hot from the cold air. The fans in the cooling unit are redundant and with variable speed, to optimize the energy consumption, and can quickly be replaced without stopping the system. The system is supplied by modular, redundant (N+1) UPS on line, which provides for continuity of power supply (perfect sinusoidal waveform, noise free). The inner sealed batteries provide the energy reserve in case of blackout of the mains.

The Air Condition UPS, in a sole cabinet can be equipped with the water or gas refrigerator system, and respectively provided with an external chiller unit or a motor condensing unit. Following the standard data. Technical Data WATER SYSTEM MODEL SHW161 SHW162E1 SHW222E1 SHW323E1 Total cooling capacity kw 16 16 22 32 Number of fans N 3 3 5 5 Air/flow max. (automatic variation of speed) m 3 /h 2600 2600 4000 4000 Water flow (at 7-12 C) l/h 3700 3700 5070 6200 UPS (N+1) N modules N 1+1 2+1 2+1 3+1 Power/module kw 12 12 12 12 N max batteries 9Ah/12V N 120 200 200 200 Back up time (N UPS load) min 40 25 25 15 Input voltage V/ph/Hz 400/3+N/50 Output voltage V/ph/Hz 400/3+N/50 Cabinet Physical Data Weight Kg 720 1180 1125 1310 Width mm 950 1550 1550 1550 Height mm 2100 2100 2100 2100 Depth mm 1200 1200 1200 1200 Server rack unit available U (44,45mm) 17 42 42 42 External chiller unit Input voltage V/ph/Hz 400/3+N/50 Cooling capacity kw 16 16 22 32 GAS SYSTEM MODEL ACG081 ACG081E1 ACG 202E1 Total cooling capacity kw 8 8 20 Number of fans N 3 3 5 Air/flow max. (automatic variation of speed) m 3 /h 2600 2600 4000 Gas refrigerant R410A UPS (N+1) N modules N 1+1 1+1 2+1 Power/module kw 12 12 12 N max batteries 9Ah/12V N 120 120 200 Back up time (N UPS load) min 40 40 25 Input voltage V/ph/Hz 400/3+N/50 Output voltage V/ph/Hz 400/3+N/50 Cabinet Physical Data Weight Kg 720 980 1125 Width mm 950 1550 1550 Height mm 2100 2100 2100 Depth mm 1200 1200 1200 Server rack unit available U (44,45mm) 17 42 42 External motor condensing unit Input voltage V/ph/Hz 400/3+N/50 Cooling capacity kw 8 8 20

Air Condition UPS Your Complete Turnkey Server Room Air Condition UPS is a modular system that can be built in different configurations, depending on the needs of the Data Center. Its special feature is the possibility to be be adapted to the Data Center power and dimensions. Moreover it can grow with the Data Center starting from a basic standard configuration optimizing in this way the investment costs to the real needs. Basically two different cabinets are available. Cabinet CSW or CSG. These are the cooling cabinets and they can work with chilled water or refrigerant gas in connection with the external units. They are combined in the modular system to cool the apparatus for server and power UPS. Their number depends on the installed power. Cabinet SU. This type of cabinet can include the server or the battery or the UPS or a combination of them. As from the figure below, it is possible to expand the system combinig the two different cabinets depending on the Data Center requests. The Air Condition UPS smallest configuration includes two cabinets: one cabinet SU for the UPS, battery and server and the other cabinet for cooling type CSW or CSG. Below is a typical configuration with two cabinets CSW, two cabinets SU for server appartus and two cabinets SU for UPS and battery.

Air Condition UPS Your Complete Turnkey Server Room OPTIONAL ACCESSORIES PDU POWER DISTRIBUTION UNIT Bar of 20 sockets for servers: it is possible to control (from remote point) each single socket, including on /off switch by program, load current, environment temperature, humidity, water, smoke, open doors. AMBIENT CONTROL Open door Environment temperature and humidity Smoke Water FG FIREGUARD Fire monitoring unit, with 2 smoke probes plus 2 thermo sensitive cables: to switch off the fire there is a special gas cylinder. KVM SWITCHES Monitor and control servers from a single console rack version: switch with 8 or 16 ports, keyboard and touchpad. KEYPAD MODULE The Keypad Module is the processing unit of the Stand-alone electronic locking system. It includes a numerical keypad as well as the data memory and the controller unit for the storage and evaluation of the input. It is possible to connect up to two handles that will be controlled by one master handle.

Air Condition UPS Your Complete Turnkey Server Room CONNECTIVITY EBT intelligent solutions for networking allow continuous and assistant monitoring for the Air Condition UPS system. Alarm Remote Monitoring and Control SMS/ E-mail Alarm/Voltage Free Contact HTTP SNMP Display Visualisation Operation Remote Maintenance CUSTOMER Air Condition UPS can provide remote information using different ways. The user can get the status through mobile phone, SMS, PDA (personal digital assistant) and internet connections. It is possible to have a display of functional parameters and also an operational control.

EBT EURO-Batterietechnik GmbH Philipp-Reis-Str. 7 D - 61137 Schöneck Tel.: +49 6187 9548-0 Fax: +49 6187 9548-29 Mail: info@eurobatterietechnik.de www.eurobatterietechnik.de