Malem Enuresis Wireless Alarm Instruction Booklet



Similar documents
Alarm Clock USER GUIDE

User s Manual VTech Printed in China US

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

GE Wireless Devices Battery Replacement

Getting started with

900 MHz Lightweight Wireless Stereo Headphones

Wireless Indoor/ Outdoor Thermometer

WIRELESS HOME ALARM SYSTEM (WHA1)

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Wireless Home Security Alarm System AM 500

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

DMSG_0152_0112_V4 Mamas & Papas (Holdings) Ltd Dream Swing - 1 -

User s Manual BROK THE BRACHIOSAURUS VTech Printed in China US

Important Safeguards

User Manual 使 用 者 指 南. Aputure Manufacturing Authority

Total Protection Alarm System

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Carpet Shampooer 500w

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Stove Guard Kit User Manual

Fitness Wristband Active TX 38

AM/FM Pocket Radio with Mono Earphone

Digistat RF Troubleshooting Procedure

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

MODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system way pager system

SMS Alarm. User Manual

Please read and keep these instructions. Run water through your machine before first use

SECTION 1-5 OPERATION OF INSTRUMENTS AND CONTROLS Lights, Wipers and Defogger

Portable Air Conditioner

FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL

CarePartner Telephone With Reminders

Alarm Security Kit - NVR

EnergySmart monitor user instructions

Juice Box Stages 1&2 135&335 Installation Guide 5/10/08

ENERGY AWARE. Monitor User Guide

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

INSTRUCTION MANUAL RM AM/FM Digital Alarm Clock Radio

Weather Radio Alarm Clock

Micro Wireless Electricity Monitor

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Sonic Boom Travel & Bed side Alarm Clock with Bed Shaker Model SB200ss-v3

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

MODELS 7007 Gorilla Cycle Alarm 7017 Gorilla Cycle Alarm with 2-way pager system way pager system

AM/FM PLL Clock/Table Radio

OC-3 SERIES OF PRINTERS

User s Manual. Kidiminiz VTech Printed in China US

USER'S MANUAL. VTECH Printed in China

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01


Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM

FSLIMRF

Triac Printed Circuit Board Replacement

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

musical auto mirror day & night light Control Panel Features Mirror Features Front View Mirror Features Rear View B C Remote Receiver C

BT Big Button 100. User Guide

Potty Training. When are children ready to potty train?

User Installation Guide

AM/FM Portable Radio

Shadow TX(A) Shadow RX

quick reference guide Edge 605/705 GPS-ENABLED BIKE COMPUTER

Keys Master, submaster and valet key Key number Door locks Power door locking switches

ALARM SYSTEM INSTALLATION GUIDE

Manual IB-3620 Series

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Single Day Alarm Clock with. Bluetooth and USB Play-through

Care of a Foley Catheter

TS93 EMR T/PT/TDE. Surface applied door closer

UT202A Operating Manual. Contents

Your Simple Guide to Battery. Replacement. Customer Care:

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

CAD-05 Kit GSM Auto Dialer. Owner s Manual

Converse 320. Userfriendly Guide

ERIC S GUIDE. to Teenage Bedwetting

User's Guide. Pinless Moisture Meter. Model MO257

Support Cleaning Apparatus. Operation, Cleaning, & Safety Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

Wipers and washers WINDSCREEN WIPERS. Intermittent variable delay

digital fever alert ear thermometer suitable from birth instruction manual

Instructions for Using the Watch Works Tool Kit to Change a Watch Battery

4.3-inch Back-Up Camera

Battery Wall Controller. Manual

Instructions Manual AmazonBasics 12-Sheet Cross-Cut Paper / CD / Credit Card Shredder with Basket ASIN# B005QAQFFS. Customer Service

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

868 MHz. VdS. Original size Aluminium. The first ARGUS Smoke Detector System with VdS* approval. * Association of. Polar white.

TIMEX is a registered trademark of Timex Corporation Timex Corporation.

Business/ Home GSM Alarm System

NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NV7210N NW3620N NW4820N

Vacuum Hair Clipper. 10,000 prize draw. Register online for HC6550. EXTRA year guarantee FREE rewards gallery

A Guide to Help You Manage Your Catheter and Drainage Bags

Looking after your urinary catheter at home. An information guide

the Soft Top Breville Customer Service Center Instruction Book - Livret d instructions

The Traxxas TQ-3 Radio System

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

ATS-505. GB Version 1

Wireless Alarm System. Silent Alert. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2

Milwaukee USER MANUAL

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

Transcription:

Model MO12 Malem Enuresis Wireless Alarm Instruction Booklet IMPORTANT Please read instruction booklet before use Best Results are obtained when: 1. Child is motivated and wants to be dry. 2. Child wakes up to the alarm when activated. 3. Parents/Guardians help to wake up the child when the alarm sounds especially at the early stages of treatment. 4. The receiver must be in the same room with the child so that the child can wake up and reset it. 5. No lifting, no nappies and no withholding fluids. Alarms cure by speeding up the natural process Malem Medical, 10 Willow Holt, Lowdham Nottingham NG14 7EJ, England, UK Tel: + 44 (0)115 966 4440 Fax: + 44 (0)115 966 4672 E-mail: malem@malem.co.uk Web: www.malem.co.uk Web: www.malemmedical.co.uk FCC Certified. Malem Medical 2009 MM160109

Malem Enuresis Wireless Alarm Instructions: Please read 1. Select a pair of close fitting cotton underpants. 2. Attach the small transmitter (Tx) to the outside of the underpants waistband using the magnetic clip. See page 12. 3. Lift the Easy-Clip lever, remove and dispose of the white plastic insulator (if present). Keep lever up. 4. Attach the Easy-Clip sensor to the outside of the underpantsʼ, at the location most likely to get wet first (boy or girl), by folding and inserting the material inside the sensor jaws at the front. Lower the lever to lock onto the material. See diagram below. 5. Switch on the receiver (Rx). Red LED will flash. 6. Place the receiver away from the bed but in the same room if treating Enuresis (bedwetting). 7. Upon waking to the alarm sound, remove the Easy-Clip sensor by lifting the lever. Stop the alarm sound by pressing the reset button on the top of the receiver. Do not switch off the receiver. Use the lavatory to completely empty the bladder. 8. Replace the transmitter and the Easy-Clip sensor onto a clean and dry pair of underpants as before. Lock the Easy-Clip onto the material by pressing down the lever. IMPORTANT: DO NOT PLACE ANY MATERIAL UNDER THE SECURING LEVER. Place underwear material into mouth (jaws) at the front of the Easy-Clip. IMPORTANT: Regularly CLEAN Easy-Clip Sensor in soapy water, rinse and shake dry. 2

Malem Enuresis Wireless Alarm Important: Rapid awakening upon hearing the alarm is vital for success. Most children, including non-bedwetters, tend to sleep soundly and heavily when at home. Better results are obtained if the parents/guardians help to wake the child upon hearing the alarm. The child must wake up sufficiently to be able to recall the event in the morning. Motivation is vital. The child must want to be dry before using the alarm. You cannot help a child that does not want to help his or herself. Try and find out why they donʼt want to be helped. It could be some other problem. The child should be allowed to drink as much as they need even before going to sleep. Fruit juice or water is ideal. Avoid fizzy drinks, tea and coffee. No nappies or pull-ups. No lifting of the child (to empty the bladder) before the parents go to bed. Use a progress chart. Great encouragement is delivered by seeing a steady improvement. Always praise the child for a dry night. Never scold or chastise for a wet night. To avoid relapses use the alarm for a minimum of two weeks after dryness has been achieved. Regularly clean the Easy-Clip sensor in soapy water. Rinse and shake dry to prevent ʻfluffʼ and urine accumulation inside the jaws. Always test the alarm by lowering the Easy-Clip lever (without material). The Tx LED should glow and the receiver should sound. When not in use never leave the Easy-Clip lever down as this will activate the transmitter and discharge the battery. Always remove the batteries and clean the Easy-Clip sensor if the alarm is not going to be used for a long period of time. 3

Settings Sound selection: See page 9 Off 1 2 3 4 5 6 7 8 9 10 The Malem wireless alarm is set to 8 random sounds. If you wish Sound selection switch to change to a single sound, remove setting for 8 random sounds receiver battery cover, slide all the For single sound selection switches from 1 to 9 to off (leave 10 on). Select any of the sounds from 1 to 8 by On sliding the switch to ʻOnʼ. Sliding switch 10 to ʻOffʼ will disable all sounds. Off 1 2 3 4 5 6 7 8 9 10 Only the LED will be activated. Select any one (1-8) to ʻonʼ Channel selection: See page 11 The Malem wireless alarm consists of a matched pair of a transmitter and receiver. To avoid interference from other wireless equipment, you can change the channel. 1 2 3 4 5 6 A choice of 64 settings is possible. Channel Selection Switch Remove the back of the transmitter by using a slotted screwdriver. Twist to open. Change the setting of the code selection switch by moving any of the switches in any of the 64 combinations. Replace the back of the transmitter. Avoid disturbing the water-seal ring. Re-tuning (Pairing) the receiver: See page 9 Push once then remove the straight end of a paper clip into the small hole at the back of the receiver under the green LED. The green LED will glow. Lower the lever of the Easy-Clip (without material), the green LED will flash and the alarm will sound. Lift the lever of the Easy-Clip and press the reset button on the top of the receiver. The receiver and the transmitter are now automatically re-tuned again. To prevent interference, use the same procedure when using more than one pair of alarms in the same location. Alternatively, you can tune several receivers to the same transmitter. This is ideal if parents/guardians want an additional receiver in their bedroom. 4 On

Fault Finding Alarm does not sound: Switch on the receiver (Rx). Red LED light will flash. Replace batteries with new Alkaline ones (2 x AA). Observe correct battery orientation and make sure contacts inside the alarm are clean and free of any deposits. Does the transmitter red LED glow when the Easy-Clip lever is lowered? If not, replace battery (Alkaline 23AE 12v) observe correct polarity and clean contacts. If all the above fail, re-tune Rx and Tx, see pages 4 and 9. Alarm does not reset: Clean Easy-Clip sensor by lifting lever, wash in soapy water, rinse under the tap and shake dry. Make sure Easy-Clip lever is up. Make sure that underpantsʼ material is not too thin or wet. Replace receiver batteries (2 x AA Alkaline). Transmitter is damaged or flooded. Sound level is too low: Adjust sound level with volume control. Guarantee Under normal use the Malem Wireless Alarm is guaranteed for a period of three months from purchase. This excludes batteries, flooding, misuse, physical or accidental damage. If the alarm should malfunction during this period, please contact us BEFORE RETURNING. Please remove batteries and decontaminate the unit/sensor before returning. DO NOT return flooded or contaminated alarms. Repairs If your alarm requires repair, we will exchange it for a new one at a special discount. (Repairs are not undertaken for hygiene reasons). Please contact us by telephone, fax, e-mail or in writing for the cost of this service. Please decontaminate the unit before returning. 5

Cleaning Alarm units: Wipe clean using a damp cloth and mild detergent. Dry thoroughly. Never immerse in water. Easy-Clip Sensor: Lift lever and clean in soapy water, rinse under the tap and shake dry. Specifications: Transmitter (Tx) Colour: Green Dimensions: 4.4cm x 4.2cm x 1.9cm Weight: 40g including battery and sensor Battery: Alkaline 23AE 12v. Observe correct polarity when replacing Range: Approximately 25m depending on nature of the structure and state of the battery. For treatment of Enuresis (bedwetting), receiver (Rx) must be in the same room as the transmitter (Tx). Sensor: Easy-Clip. Keep lever up when not in use. Clean sensor regularly. Clip: Magnetic to secure Tx on outside of underpants along waistband (see diagram on page 12). LED: Internal red in colour. Glows when sensor detects wetness or if lever is lowered without dry material between the jaws in the front of the Easy-Clip sensor Frequency: 433MHZ Model: MO12 (Tx) The normal fuction of the product may be disturbed by Strong Electro Magnetic Interference. If so, simply reset the product to resume normal operation by following the instruction manual. In case the function could not resume, please use the product in another location. 6

Specifications: Receiver (Rx) Colour: Dimensions: Weight: On/Off: Volume: Reset: Red LED: Green LED: Tuning Point: Battery: Green 7.4cm x 7.6cm x 2.5cm 95g including batteries Sliding switch on side Volume control wheel on the side. Turn up to increase and down to decrease. Button on the top. Will not reset if Tx is active. Flashes every 3 seconds when Rx is ready for use. Glows only during automatic tuning. Small hole below green LED. Depress with the end of a paper clip. Green LED will glow. Activate the transmitter (Tx), the green receiver (Rx) LED will flash. The alarm will then sound to indicate that re-tuning (pairing) is successful. 2 x Alkaline AA. Observe correct polarity and clean contacts when replacing. Sound Selection Switch: Under battery cover. For single sound: Slide to ʻOnʼ any switch between 1 and 8. Other switches apart from 10 must be ʻOffʼ. Important: Tx and Rx must be in the same room for treatment of Enuresis (bedwetting). If Tx and Rx are not to be used for a long period of time, then it is advisable to remove the batteries from both. DC Input: 3v DC input on the side if required. - Model: MO12 (Rx) Standards: FCC Certified. Malem Medical reserves the right to change specification without prior notice. 2009 Malem Medical. + 7

Malem Enuresis Alarm WIRELESS ALARM RECEIVER (Rx) Buzzer Reset Button Fast Flash when alarm is activated Volume Control LED Flash once every 3 seconds: Ready for use DC in 3V DC - + Volume Control MALEM Power Switch Off On Wireless Alarm Receiver (Rx) Use Alkaline batteries ONLY 8

1 2 3 4 5 6 7 8 9 10 Malem Enuresis Alarm WIRELESS ALARM RECEIVER (Rx) Sound selection switch On Off Sound Selection Correct setting for 8 random sounds (only one sound is activated each time alarm is triggered) On 1 2 3 4 5 6 7 8 9 10 Off 8 random sounds setting For single sound: Select any one between 1-8. 9 must be ʻOffʼ 10 must be ʻOnʼ 2xAA ALKALINE OPEN Reset Button Green Pairing LED Pairing Tuning Hole Channel Re-tuning (Pairing) Press through the hole with a thin wire - such as a paper clip end to activate tuning. The green LED will glow. While glowing activate Tx by lowering Easy-Clip lever. The green LED will flash then stop. The pairing is then complete. Receiver is automatically tuned to the transmitter. Slide cover down to access batteries and sound selection switch. Lift Easy-Clip lever and press reset button on Rx to stop alarm sound. Use Alkaline batteries ONLY 9

Malem Enuresis Alarm WIRELESS ALARM TRANSMITTER (Tx) The red LED light will glow when transmitter (Tx) sensor is wet, also if the Easy Clip sensor lever is down and there is no dry material between jaws. The battery will drain if the LED light is left on when not in use. MALEM Wireless Alarm Transmitter (Tx) Clear band holder Use slotted screw driver, twist to open back cover for replacing battery or changing the channel code Magnetic clip Use Alkaline batteries ONLY 10

Tx back off Malem Enuresis Alarm WIRELESS ALARM TRANSMITTER (Tx) Channel code selection switch 64 channel choices. If selection switch setting is changed then the receiver (Rx) must be re-tuned to the transmitterʼs (Tx) new code. On ALKALINE 1 2 3 4 5 6 Off Battery Type ALKALINE 23AE 12V REPLACE BATTERY if red LED light does not glow. Make sure contacts are clean when replacing the battery. Observe correct battery orientation. Place underpant material between the jaws. Lift lever to open jaws, push down to shut jaws Jaws Easy-Clip sensor (Leave lever lifted up when not in use) Clean regularly in soapy water, rinse and shake dry. Use Alkaline batteries ONLY 11

Malem Enuresis Alarm WIRELESS ALARM TRANSMITTER (Tx) Set up position on underpants MALEM Wireless Alarm Transmitter (Tx) Use Alkaline batteries ONLY 12