LOSS PREVENTION REPORT "THE EQUIPMENT BREAKDOWN SPECIALISTS" SUMMARY



Similar documents
ABC PLAZA. For. ABC PROPERTY MANAGEMENT (Client)

Thermal Imaging Specialists Consultancy - Camera Sales - Training

BLUESTAR INFRARED. Description: Thermal Properties Comparison. Project Location: Client: 759 South Federal Hwy 225 Bayshore Drive

Supplemental Health Insurance Products Inventory Report. May 2014

How To Know The Nursing Workforce

Pressure Control Supplier Quality Requirements Nondestructive Testing Services SQ-10 Rev: 1.1

Applications for Infrared Thermography at Computer Centers

Predictive Maintenance in a Mission Critical Environment

Infraspection Institute Online Store Affiliate Program ~ Application & Programming Instructions ~

Non Invasive Roof Leak Detection Using Infrared Thermography

FEBRUARY 2016 PTAB Public Hearing Schedule

OFFICE OF INSPECTOR GENERAL SPECIAL FRAUD ALERT FRAUD AND ABUSE IN NURSING HOME ARRANGEMENTS WITH HOSPICES

The New Analytical Mindset For Finance and Accounting Professionals

Appendix B Audit Forms for PdM Program Assessment

Guide to certification EMEA & APAC

WHAT IS INFRARED (IR) THERMOGRAPHY

INFRARED DIAGNOSTIC REPORT ABLE INSPECTION COMPANY Post Office Box Houston, Texas (713)

SALISBURY ASSESSMENT SOLUTIONS

COMMON EQUIPMENT FAILURES AND CAUSES. How breakdowns can impact the bottom line. A handy reference guide from Hartford Steam Boiler.

Biomedical Equipment Technology

Enhance Power Equipment Reliability with Predictive Maintenance Technologies

A Practical Guide to Maximizing Machine Uptime

Reducing Arc Flash Risks with Electrical Maintenance Safety Devices

Preventative Maintenance & Statutory Testing

Legal Placements, Inc.

Cornell Law School February 2014 Public Interest Low Income Protection Plan

Statement Of Work. Data Center Thermography Assessment. Service. Professional Services. Table of Contents. 1.0 Executive Summary

Thermal Imaging Scan Reveals the Truth Behind the Wall

Response, Reliability and Results in the delivery of leak detection services

Corrosion Coupons May Not Be Useful for Predicting Data Center Equipment Failure Rates

Managing 188 shopping centers totaling 20.4 million square feet Total Property & Asset Managers: 33 D-FW: 21 Austin: 6 Houston: 3 San Antonio: 3

Infrared Thermography and Water Damage Assessment

HSB Home Systems Protection

High Voltage Electrical Equipment Failure Diagnosis. Presented by: Spencer Tang & Terence Ng T&T Inspection & Engineering Sdn Bhd

Identifying energy savings with thermal imaging

Lodging, Rental Car and Meal Taxes on Travelers in the Top 50 U.S. Cities

PEER Analysis of OSHA Recordkeeping Inspections Done Pursuant to its National Emphasis Program (NEP)(10/09-8/10) SUMMARY OF DATA

Acuren s Vision: To be a Trusted Partner by Providing Programs that clearly reduce our client s cost to operate.

Start Seeing the World In Infrared

ISS YOUR COST-CONSCIOUS PARTNER

Distance Learning - Cost Effective Education for Maintenance Professionals. Presented by. Perry Cabrera Infraspection Institute Ultrasound World VI

For Predictive Maintenance Technologies

Expert Services. Account Management Jurisdictional Equipment Inspections Risk Control Claim Management

Q Utility Rebate Report. Fort Worth, TX

Graduate Physics Degrees Largest Departments and Degree Distribution

IRS ISSUES FINAL REGULATIONS FOR COMPARATIVE EFFECTIVENESS RESEARCH FEES

Texas. DeVry Impact. Summary Statistics. Earnings by Education Level. Total Wage Growth Over Studied Period. 65% Growth $44, % Growth $39,478


Time to fill jobs in the US January day. The. tipping point

Five Nines and Infrared (IR) Testing at Data Centers

Online Labor Demand Shows Strong Increases, up 217,900 in December

OSHA Focuses Enforcement Resources on Nursing and Residential Care Facilities

Replicating the Manchester Bidwell Model

Number of Liver Transplants Performed Updated October 2005

AT&T Device Support Center Holiday Operating Hours (November/December)

Employee Benefits Alert

2016 Instructor Training & Certification Schedule

Q Utility Rebate Report. Houston, TX

Infrared Cameras Can Aid Building Inspectors in Detecting Roof Leaks, Water Damage, Mold and Other Moisture Related Problems

How much are teachers really paid? A Nationwide Analysis of Teacher Pay

Atlanta Rankings 2014

BOILER AND MACHINERY ENGINEERING SERVICE PROPOSAL PREPARED FOR THE STATE OF FLORIDA

EMPLOYER PAY OR PLAY EXCISE TAXES WHERE ARE WE NOW?

Comprehensive Course Schedule

March 31, 1999 CLARENCE E. LEWIS, JR. CHIEF OPERATING OFFICER AND EXECUTIVE VICE PRESIDENT YVONNE D. MAGUIRE VICE PRESIDENT, HUMAN RESOURCES

Eaton Customer Manufacturing Solution Centers (CMSC) Solutions for every industry

ANGELOUECONOMICS 2012 INDUSTRY HOTSPOTS

Plan Review and Inspections in All Trades

U.S. NEWS RANKING OF MEDICAL COLLEGES 2012

National Board of Boiler and Pressure Vessel Inspectors Application for the Inservice or Owner-User Commission

THE OKONITE COMPANY. Ramsey, New Jersey Fax:

FLIR i-series Point-and-Shoot Thermal Imaging Cameras

NDT to Identify Concrete Bridge Deck Deterioration

Tune Up Your Condition Monitoring Program by Answering the Five W s

EXAMINING COSTS AND TRENDS OF WORKERS COMPENSATION CLAIMS IN MASSACHUSETTS

How to Get NetFlow from Cisco 3750s. Joe Buchanan System Engineer Manager

Table of Contents. Enhanced Use Leases Awarded. Introductory Statement Lease Awards Departmental Enhanced-Use Lease Priorities...

Ethernet Access (Formerly Converged Ethernet Access) Operations Manual

InfraMation The Infrared Camera Applications Conference ANNIVERSARY

Medical Toxicology! Medicine! Infectious Disease! Acute and Critical Care Medicine 2

Vicki Phipps. Focus Areas. Overview

ALERT HEALTH CARE REFORM LAW HUMAN CAPITAL PRACTICE 90-DAY WAITING PERIOD AND ORIENTATION PERIOD: FINAL REGULATIONS EXPLAINED BACKGROUND

TSA of TCEQ Air Monitoring Program Austin, Texas September 7-28, 2010

Flagger Training & Certification

Response, Reliability and Results. for Managed Property

service above and beyond

Inspection Report. Mr. John Homebuyer. Property Address: 123 Main Street Houston TX Front View. EDP Consulting Engineers, PLLC

Project Team ALDINE INDEPENDENT SCHOOL DISTRICT CLIENT MORRIS ARCHITECT

ANSI Watthour Meter Testing & Certification Programs

Post-Graduation Survey Results 2013 College of Fine Arts School of Design Undergraduate

Office Space FOR LEASE. Derry & Tomken Business Centre. 979 & 989 Derry Road East, Mississauga. For more information, please contact:

MEDICAL STAFF DIRECTORY

Accredited TOGAF 9, ArchiMate 2 and IT4IT Training Course Calendar June 2016 onwards

IT Senior Audit Leader

Case 3:13-cv P Document 1-1 Filed 05/07/13 Page 1 of 6 PageID 10

Testing & Consulting Engineering. NDT Industrial Environmental D.O.T, Construction & Mechanical.

Hiring and Compensation

Main Boiler Safety Page Fax

Physical Therapy Marketing Success :: physical therapy assistant schools usa

Transcription:

LOSS PREVENTION REPORT "THE EQUIPMENT BREAKDOWN SPECIALISTS" Insured: Texas State Office of Risk Management (SORM) HSB ID No.: Location No.: 2311772/00077 300 W. 15 th St. 6 th Floor Austin, TX 78701 Location: Representative: Jim Nelson Inspection Specialist University of Houston 601 University Drive Service Date: 03/05/2013 Victoria, TX 77901 Report Date: 03/05/2013 SUMMARY The University of Houston in Victoria, TX was visited on March 5, 2013 by Mr. Jim Nelson. The purpose of the visit was to do an infrared scan of the electrical supply and distribution system. Occupancy Description: University The following personnel participated in the inspection: Mr. John R. Burke Manager, Building Maintenance Facilities Services An initial meeting was held to discuss the purpose of this visit, followed by the scan and concluded with an exit interview to review the results of the inspection. Should you have any questions or comments concerning this report or our services, we are here to assist you. Please feel free to contact your Inspector at (903) 217-7016 or by email: jimmy_nelson@hsb.com. 1

OVERVIEW Infrared thermographic surveys are non-contact, non-destructive examinations used to find abnormal or unexpected thermal patterns or temperature differentials. These thermal patterns may indicate such conditions as loose connections, overloaded circuits or phases, deteriorated or damaged insulation or refractory, or excessive or unwanted friction, among others. To perform the thermographic survey of your facility, HSB Thermography Services used the FLIR Thermacam infrared imaging system. This system utilizes the latest developments in un-cooled technology to generate the most accurate data available. The calibration for this system is certified traceable to The National Institute of Standards and Technology, NIST, USA and the Swedish National Testing and Research Institute, SP. This calibration is based on the International Temperature Scale (ITS-90). Mr. Nelson is a Level II Thermographer certified in accordance with the American Society of Nondestructive Testing (ASNT) SNT-TC-1A and Hartford Steam Boiler Inspection and Insurance Company s Qualification Standards. 2

Recommendation Definitions RECOMMENDATIONS The criteria used to categorize findings in this report are based on the potential effect that a failure will have on operations and/or production. CRITICAL- Failure of this component will have a significant impact on production, require costly repairs. SEVERE- Failure is not expected to go beyond the component listed and should have minimal impact on operations and production; repair costs could be significant. ALERT- Failure is of a routine nature and repairs can be made easily and at a reasonable cost. Cost is more often than not, limited to labor and a few minor parts. ADVISORY- Helpful information based on sound engineering judgment. Recommendation Summary Recommendation No. CATEGORY Location Area Equipment Location IR-13-03-05-01 SEVERE Facility Office Building Electrical Feeder 3

Recommendation No. IR-13-03-05-01 Category SEVERE Location Area Facility Office Building Equipment Location Electrical Feeder Equipment ID Splice Connection Est. Repair Cost $300 Before Failure Est. Repair Cost $500 After Failure Est. % of Production 100% Est. Down Time 4 Hours 63.8 F 62 60 58 Ref. Temperature 54.5 F Area 1 Max. Temperature 69.6 F Area 1: Rise 15.2 F 56 53.2 54 Recommendation/Comments: At the time of this image the loading was low. It will be necessary to replace this splice connection. Failure could result in damage to running equipment, especially computer systems. Contact the local utility to make this repair. Repair notes: Signature:....Date: 4

For more information or comments contact: JR Smith- Manager of HSB Thermography Services Cleveland, OH 216-588-1381 Ronald_Smith_Jr@HSB.com Norm Gaver LVL II Thermographer Charlotte, NC 704-892-3421 Norman_Gaver@HSB.com Jim Nelson LVL II Thermographer Dallas, TX 903-217-7016 Jimmy_Nelson@HSB.com Ross Regadanz LVL II Thermographer San Francisco, CA 831-750-8637 Ross_Regadanz@HSB.com Bill Viot LVL II Thermographer Hartford, CT 860-281-2541 William_Viot@HSB.com Ken Zavacki LVL II Thermographer Chicago, IL 773-213-4105 Kenneth_Zavacki@HSB.com Sandy Sanor LVL II Thermographer Alexandria, VA 571-277-4727 Sandy_Sanor@HSB.com 5