1 At ABC PLAZA For ABC PROPERTY MANAGEMENT (Client) SCHNEIDER ELECTRIC (Hong Kong) LIMITED PRJXXXXX Report Print Date
2 TABLE OF CONTENTS COPYRIGHT, DISCLAIMER, PRIVACY POLICY AND FURTHER INFORMATION EXECUTIVE SUMMARY Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 SCOPE OF WORK REFERENCED STANDARDS GENERAL CONCEPT AND PRINCIPLES INSPECTION METHODOLOGY INSPECTION CONDITIONS INSPECTION RESULTS ANALYSIS CONCLUSION AND RECOMMENDATION 2/16
3 COPYRIGHT, DISCLAIMER, PRIVACY POLICY AND FURTHER INFORMATION Copyright Copyright restrictions apply to individual documents on this Report. Unless otherwise stated, the following copyright statement applies to documents found on this Report. Disclaimer RETAIN FOR USE OF QUALIFIED MAINTENANCE PERSONNEL ONLY. Schneider Electric (Hong Kong) Limited will only provide the infrared thermographic scanning inspection service according to the in-housed infrared thermographic survey procedure. The analysis report is only for internal reference of the client. Schneider Electric (Hong Kong) Limited will not be responsible for any legal duty and responsibility so caused by the analysis report. The client accepts full responsibility for any legal duty. The total liability of Schneider Electric (Hong Kong) Limited under this contract agreement shall be limited to the inspection area where infrared thermographic scanning took place. Except as set out herein, Schneider Electric (Hong Kong) Limited shall be under no liability whatsoever to the Client for any loss, expense or damage howsoever caused, whether in contract or in tort or pursuant or any Statute, Rule or Regulation of otherwise, and whether such loss, expense or damage resulted from any act or omission or advice, including any negligent act or omission or advice given by Schneider Electric (Hong Kong) Limited. Privacy Policy We have duty to protect any information we collect from you. We do not pass on your details to any third party unless you give us permission to do so. 3/16
4 COPYRIGHT, DISCLAIMER, PRIVACY POLICY AND FURTHER INFORMATION Further Information Please address any comments or questions you may have on the contact call or text to: Project & Services Department SCHNEIDER ELECTRIC (Hong Kong) Limited Rooms, , 31/F., Sun Hung Kai Centre, 30 Harbour Road, Wanchai, Hong Kong. G.P.O. Box 3125 H.K. Tel. (852) Fax (852) , (852) Hotline (852) Web page: 4/16
5 EXECUTIVE SUMMARY In general results of inspected locations where incorporated at this report were commented at Normal Condition. In addition to above classification, there are only TWO anomalies location finding which are described as Indicate Deficiency and stated below in briefly, and have detail analysis within the report. Delta-T Classification Action Required (Recommendation) Category 0 C to 3 C Warrant Investigation Indicate Possible Deficiency. 4 C to 15 C Repairs should be made as time permits Indicate Deficiency 16 C and above Repairs should be made immdediately Indicate Major Deficiency Busway Code Ampere Rating (A) Description Location B Tenant G/F to 18/F Location 1 (anomaly): G/F, Main Switch Room No. 2 THE BUSWAY JOINT CONNECTION (J1), TEMPERATURE RISE Delta-T 4.7 C As against with its reference temperature at 32.2 C Location 2 (anomaly): G/F, Main Switch Room - MCB Board OVERHEATING at 37.2 C and 37.3 C respectively. As against Satisfactory Spot (Sp03) at 31.1 C Temperature Rise 6.1 C & 6.2 C 5/16
6 Section 1 SCOPE OF WORK To perform quantitative thermography inspections to below location of existed installed Square D Busway System. Site Address: -- Busway Code Ampere Rating (A) Description Location B Tenant G/F to 18/F 6/16
7 Section 2 REFERENCED STANDARDS ASTM E a Standard Guide for Examining Electrical and Mechanical Equipment with Infrared Thermography. NEMA STANDARDS PUBLICATIONS BU General Instructions for Handling, Installation, Operation, and Maintenance of BUSWAY Rated 600 Volts or Less. 7/16
8 Section 3 GENERAL CONCEPT AND PRINCIPLES Conventional techniques such as impedance testing and torque checking have a relatively low effectiveness in detecting and preventing failure due to these causes. Thermal imaging is the technique for making invisible infrared radiation visible (can be described below by the Stefan-Boltzmann law) and is the non-contact on-line mapping and analysis of thermal patterns from the surface of an object that can be employed to detect these temperature rises as "hot spots". Identification of hot spots can be used to trigger remedial works, reducing the number of defects and improving reliability. Principles of Thermal Imaging, the radiation emitted from the surface of an object is a function of the object temperature as described by the Stefan-Boltzmann relationship. The infrared element of the radiation is measured and constructed from a multitude of point measurement taken in sequence whilst scanning the field of view by representing the point temperature values. W = s.e.t 4 Where W is the radiant power emitted (W/m 2 ) s is the Stefan-Boltzmann constant (5.69 W/m 2 K 4 ) e is the object emissivity T is the absolute temperature of the object (K) Note: The Stefan-Boltzmann law states every object at any specific temperature, T, will radiate energy is proportional to the fourth power of the absolute temperature: T 4. The number one application for infrared thermography globally is electrical applications. The temperature of electrical components and connections are indicative of their health. Excessive heat due to increased electrical resistance (can be described below by Joule's law) will be generated by faulty components and by loose or deteriorated connections, short-circuit, overload, mismatched or improperly installed components. Equipment running hot can also be related to load imbalance, failure of cooling etc. Missed or deteriorated materials, improper installation or insufficient amounts of material usually cause anomalies in insulation system. P = I 2 R Where P is the Effect (Watts) R is the Resistance (OHMS) I is the Current (Amperes) Note: The Joule's law states that if the resistance R does not change and the current doubles, the power consumption will increase four (4) times thereby increasing the temperature of component. This means the higher the current flow, the higher the temperature of the entire circuit. Further increase of resistance by badly made joint connect will therefore be reflected by the abnormal temperature rises. 8/16
9 Section 4 INSPECTION METHODOLOGY In addition to the referenced standards, the following method statements are being carried out in order to make quantitative thermal imaging and accuracy of inspection data results. (A) Equipment used: - FLIR ThermaCAM E30 Camera, C/W 19 degree lens - PC notebook (for extra storage of images) - Digital Camera - Psychrometer - HILTI PD20 (object distance measuring device) (B) Method Statements: - Discuss with qualified site technical assistance about the inspection services detail planning prior to conduct thermal scanning. - Obtain authorization and by safety access route leading of qualified technical assistance to inspection area in terms of efficiency. - Inspect the busway with the Equipment relocated from vantage point to vantage point. - Provision of actual load (phase by phase) of busway circuit by qualified site technical assistance as required by Infrared Thermographer. - Record date, time and the Busway Location / Sections to be inspected. - Record the Ambient Temperature. - Record the distance of Busway to IR camera. - Take quantitative IR images associate with its digital image to the area / location / anomaly of Busways being inspected. - Take digital images for those busway where installed at unexposed area, if any. ThermaCAM Report Professional is used with ThermaCAM E30 Camera for processing of inspection results analysis. 9/16
10 Section 5 INSPECTION CONDITIONS Date of Inspection Services:15th April 2005 (Friday) Time:10:30am ~ 11:30am Location: As Specified Thermographer Profile:Mr. Chris Lam / Mr. Raymond Yu Qualified Site Technical Mr. Technician Assistance: Busway Inspected Conditions:All inspected busways are adequate for conducting Infrared Thermography Scanning. Date, time, ambient temperature, distance of Busways to IR camera, Busway Rating and its relevant phase-to-phase loading are specified on Inspection Results individually. 10/16
11 Site: Location: ABC PLAZA G/F, Main Switch Room No.2 Equipment / Environmental Data: Section 6 INSPECTION RESULTS ANALYSIS Job Reference: PRJXXXXX Sketch # Index Circuit No. Rated Load Phase A Phase B Phase C Phase N (A) (Amp.) (Amp.) (Amp.) (Amp.) -- 1 B4 3000A 1500A (Max.) LI01: 37.4 C SP01: 32.9 C 39.0 C SP02: 37.6 C 34 IR information Value Date of creation Time of creation 10:43:14 AM File name Ir_ jpg Camera type ThermaCAM E30 Camera serial number IR Text Comment Value DC File Name 119_1917.JPG Joint Indication J C 35 li01 Line Min Max Cursor li C 37.4 C - 32 Object parameter Value Emissivity 0.85 Object distance 3.0 m Ambient temperature 28.5 C Relative humidity 0.53 Label Value SP C SP C Delta-T (SP02-SP01) 4.7 C C IR01 ANALYSIS: Fault Spot (SP02) HOT at 37.6 C As against Satisfactory Spot (Sp01) at 32.9 C Temperature Rise 4.7 C RECOMMENDATION Power OFF the Busway, Check and Clean Each Copper Phases Surfaces. Re-tigten With Correct Level of Torque Loading at lbs-ft. 11/16
12 Site: Location: ABC PLAZA Tower 2, 13/F Meter Room Equipment / Environmental Data: Sketch # Index Circuit No. Rated Load (A) Section 6 INSPECTION RESULTS ANALYSIS Phase A (Amp.) Job Reference: Phase B (Amp.) PRJXXXXX Phase C (Amp.) Phase N (Amp.) -- 1 B4 3000A 1500A LI01: 35.3 C SP02: 33.3 C 37.0 C SP01: 33.2 C 23.0 C IR information Value Date of creation Time of creation 11:24:04 AM File name Ir_ jpg Camera type ThermaCAM E30 Camera serial number IR Text Comment Value DC File Name 119_1929.JPG Joint Indication J1 C IR01 Line Min Max Cursor li C 35.3 C - Object parameter Value Emissivity 0.85 Object distance 1.0 m Ambient temperature 26.0 C Relative humidity 0.58 Label Value SP C SP C Delta-T (SP02-SP01) 0.1 C li01 ANALYSIS: Average Temperature Range from 33.2 C to 33.3 C RECOMMENDATION Continue to monitor the Temperature Trending to seek if any of abnormal. 12/16
13 Section 6 INSPECTION RESULTS ANALYSIS Site: ABC PLAZA Location: G/F, Main Switch Room Equipment / Environmental Data: MCB Board Job Reference: PRJXXXXX SP03: 31.1 C SP01: 37.2 C 38.0 C 35 SP02: 37.3 C C IR information Value Object parameter Value Date of creation Emissivity 0.79 Time of creation 3:41:57 PM Object distance 1.0 m File name Ir_0042b.jpg Ambient temperature 28.5 C Camera type ThermaCAM E30 Relative humidity 0.53 Camera serial number IR Text Comment Value DC File Name DC02413V.JPG Joint Indication -- C IR01 30 Line Min Max Cursor li C 37.3 C - li01 ANALYSIS: Fault Spot (Sp01) & (Sp02) OVERHEATING at 37.2 C and 37.3 C respectively. As against Satisfactory Spot (Sp03) at 31.1 C Temperature Rise 6.1 C & 6.2 C RECOMMENDATION Power OFF the Equipment. Break Each Joint in Turn. Check and Clean Both Connecting Surfaces. Remake and tighten with the correct level of Torque Loading. 13/16
14 14/16
15 Section 7 CONCLUSION AND RECOMMENDATION In general results of inspected locations where incorporated at this report were commented at Normal Condition. In addition to above classification, there are only TWO anomalies location finding which are described as Indicate Deficiency and stated with comment as to the required recommendation action. Delta-T Classification Action Required (Recommendation) Category 0 C to 3 C Warrant Investigation Indicate Possible Deficiency. 4 C to 15 C Repairs should be made as time permits Indicate Deficiency 16 C and above Repairs should be made immdediately Indicate Major Deficiency Location 1 (anomaly): G/F, Main Switch Room No. 2 THE BUSWAY JOINT CONNECTION (J1), TEMPERATURE RISE Delta-T 4.7 C As against with its reference temperature at 32.2 C RECOMMENDATION Power OFF the Busway, Check and Clean Each Copper Phases Surfaces. Re-tigten With Correct Level of Torque Loading at lbs-ft. 15/16
16 Section 7 CONCLUSION AND RECOMMENDATION Location 2 (anomaly): G/F, Main Switch Room - MCB Board OVERHEATING at 37.2 C and 37.3 C respectively. As against Satisfactory Spot (Sp03) at 31.1 C Temperature Rise 6.1 C & 6.2 C RECOMMENDATION Power OFF the Equipment. Break Each Joint in Turn. Check and Clean Both Connecting Surfaces. Remake and tighten with the correct level of Torque Loading. 16/16
COLORADO APCD IR Camera Survey Program Guidance/Protocol (rev. 11/8/11)
COLORADO APCD IR Camera Survey Program Guidance/Protocol (rev. 11/8/11) Disclaimer: This document is designed to assist regulatory agency staff in conducting IR camera surveys at upstream and midstream
employed to ensure the continuing reliability of critical systems.
4 Regulations 1989, Regulation 4, places a duty on employers to provide safe systems for their workers: Regulation 4 of the Electricity at Work Regulations 1989 Systems, work activities and protective
Predictive Maintenance in a Mission Critical Environment
March 2009 Predictive Maintenance in a Mission Critical Environment This paper discusses the need to proactively protect mechanical and electrical support systems in data processing centers and data storage
BLUESTAR INFRARED. Description: Thermal Properties Comparison. Project Location: Client: 759 South Federal Hwy 225 Bayshore Drive 800-216-1820
BLUESTAR INFRARED We Bring Bad Things to Light SERVING ALL OF FLORIDA Infrared Inspection Services 24 Hour Emergency Service I n f r a r e d I n s p e c t i o n R e p o r t 772-215-8794 Description: Thermal
WHAT IS INFRARED (IR) THERMOGRAPHY
WHAT IS INFRARED (IR) THERMOGRAPHY IR Thermography is the technique of producing pictures called from the invisible thermal radiation that objects emit. This is a non-contact means of identifying electrical
Model UT201/202: OPERATING MANUAL. Table of Contents
Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons The Effectiveness
Dual Laser InfraRed (IR) Thermometer with Color Alert
User Manual Dual Laser InfraRed (IR) Thermometer with Color Alert MODEL 42509 Introduction Congratulations on your purchase of the Model 42509 IR Thermometer with Color Alert. This Infrared thermometer
8001782 Owner s Manual
8001782 Digital Infrared Thermometer Owner s Manual Introduction This instrument is a portable, easy to use compact-size digital thermometer with laser sighting designed for one hand operation. The meter
Statement Of Work. Data Center Thermography Assessment. Service. Professional Services. Table of Contents. 1.0 Executive Summary
Statement Of Work Professional Services Data Center Thermography Assessment Data Center Thermography Assessment Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits
Dual Laser InfraRed (IR) Thermometer
User s Manual Dual Laser InfraRed (IR) Thermometer MODEL 42511 Introduction Congratulations on your purchase of the Model 42511 IR Thermometer. This Infrared thermometer measures and displays non-contact
High Temperature InfraRed Thermometer with Laser Pointer
User s Manual High Temperature InfraRed Thermometer with Laser Pointer MODEL 42540A 6 42540 6 Introduction Congratulations on your purchase of the Model 42540A IR Thermometer. The 42540A is capable of
Commercial Vehicle Enforcement Branch THERMAL IMAGING
Commercial Vehicle Enforcement Branch THERMAL IMAGING Thermal Imaging Unit For additional information: Mr. Steve Callahan, Chief Commercial Vehicle Enforcement Branch Room 401 4920 51 Street Red Deer,
Brian Smith 3275 Green Dolphin Naples, Florida 34102
TO: RE: Brian Smith 3275 Green Dolphin Naples, Florida 34102 INFRARED THERMOGRAPHY 1376 Great Egret Trail Naples, Estuary at Grey Oaks Inspection Date: December 14, 2007 This home was inspected using Infrared
Introduction to Infrared Thermography. Jeff Beard IT 570
Introduction to Infrared Thermography Jeff Beard IT 570 Fall 2007 Contents Welcome...3 OBJECTIVES...3 Section 1: Infrared Thermography Basics...4 1.1 INFRARED THERMOGRAPHY TERMINOLOGY...5 PRACTICE ACTIVITY
Model UT33A: OPERATING MANUAL Table of Contents (1)
Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter structure Functional Buttons LCD Display Measurement Operation
How To Calculate Thermal Resistance On A Pb (Plastipo)
VISHAY BEYSCHLAG Resistive Products 1. INTRODUCTION Thermal management is becoming more important as the density of electronic components in modern printed circuit boards (PCBs), as well as the applied
21 st Century Facilities
Electrical Testing 21 st Century Facilities Facility Owners face tough challenges 24 X 7 reliability needed Non linear loads cause harmonics VFD Computers Switching transients disrupt operations Less customer
EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER
EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER Users Manual - 1 - .Introduction Thank you for purchasing the SUPCO infrared (IR) thermometer and thermocouple meter. Please take a few minutes to browse
OSHA and NFPA 70 Understanding NFPA 70 and its Implications in Electrical Inspections 2010
OSHA and NFPA 70 Understanding NFPA 70 and its Implications in Electrical Inspections 2010 By: Martin Robinson, Level III Thermographer 18-1030-0005 Rev. A The National Fire Protection Association (NFPA)
INFRARED DIAGNOSTIC REPORT ABLE INSPECTION COMPANY Post Office Box 820129 Houston, Texas 77282 (713) 465-0000
www.ableinfrared.co www.flirthermography.com INFRARED DIAGNOSTIC REPORT ABLE INSPECTION COMPANY Post Office Box 820129 Houston, Texas 77282 (713) 465-0000 CLIENT: PROPERTY SURVEYED: EMAIL: DATE: In accordance
EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!
EPSOLAR LS0512R / LS0524R Solar Light Controller INSTRUCTION MANUAL Please read this manual carefully before using the product! LandStar LS0512R / LS0524R Solar Light Controller Nominal system voltage
Preventative Maintenance & Statutory Testing
Preventative Maintenance & Statutory Testing Emergency Evacuation Lighting - Inspection and Maintenance It is an Occupational Health and Safety Act requirement that employers have a legal duty of care
Thermal Imaging Specialists Consultancy - Camera Sales - Training
Thermal Imaging Specialists Consultancy - Camera Sales - Training A Full Range of Services Thermographic Consultancy Ltd offer a wide range of thermal imaging solutions which include technical support
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Enhance Power Equipment Reliability with Predictive Maintenance Technologies
Enhance Power Equipment Reliability with Predictive Maintenance Technologies November 2012/1910DB1208 by S. Frank Waterer, Electrical Engineerinig, Fellow Schneider Electric USA, Inc. Make the most of
Dual Laser InfraRed (IR) Thermometer
User Manual Dual Laser InfraRed (IR) Thermometer MODEL 42570 Introduction Congratulations on your purchase of the Model 42570 IR Thermometer. This Infrared thermometer measures and displays non-contact
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
Mini InfraRed Thermometer with Laser Pointer
User s Manual Mini InfraRed Thermometer with Laser Pointer MODEL 42500 Introduction Congratulations on your purchase of the Model 42500 IR Thermometer. This thermometer makes non-contact (infrared) temperature
Infrared Thermography and Water Damage Assessment
Infrared Thermography and Water Damage Assessment Noah Ceteras / Scott Wood Four Star Cleaning and Restoration / Building Science Institute ABSTRACT Thermal imaging devices have many uses across a wide
Thermal imaging guidebook
Thermal imaging guidebook for industrial applications An informative guide for the use of thermal imaging cameras in industrial applications Content page 1. The thermal imaging camera and how it works
Stop guessing - Start seeing
Stop guessing - Start seeing Infrared technology for building applications A complete camera range for all users and budgets Thermal Insulation Maintaining acceptable temperatures in buildings (by heating
AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY
AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY The Aegis Services Power and Assessment Service provides an assessment and analysis of your data center facility and critical physical
Peltier Application Note
Peltier Application Note Early 19th century scientists, Thomas Seebeck and Jean Peltier, first discovered the phenomena that are the basis for today s thermoelectric industry. Seebeck found that if you
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
Mario D. Gonçalves, Patenaude-Trempe 1 Pierre Gendron, Patenaude-Trempe 2 Tony Colantonio, PWGSC 3. Abstract
Commissioning of Exterior Building Envelopes of Large Buildings for Air Leakage and Resultant Moisture Accumulation using Infrared Thermography and Other Diagnostic Tools Mario D. Gonçalves, Patenaude-Trempe
Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)
Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter structure Functional Buttons Measurement Operation A. DC
6 & 12 Volt Battery and Systems Tester with 100 Amp Load
6 & 12 Volt Battery and Systems Tester with 100 Amp Load Form No. 841-731 -000 DESCRIPTION This Load Tester tests 6 or 12 volt automotive-size lead-acid batteries under load. It will also test 6 or 12
Capacity Testing of VRLA Batteries (20 to 200 Ampere-Hours Capacity)
TECHNICAL BULLETIN 41-7135 Capacity Testing of VRLA Batteries (20 to 200 Ampere-Hours Capacity) 41-7135/0412/CD www.cdtechno.com The VRLA battery is rated in ampere-hours or watts per cell (w/c) at specific
Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented
User's Guide Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented Introduction Congratulations on your purchase of Extech's Laser Photo/Contact Tachometer with Non- Contact IR Thermometer,
Effects of AC Ripple Current on VRLA Battery Life. A Technical Note from the Experts in Business-Critical Continuity
Effects of AC Ripple Current on VRLA Battery Life A Technical Note from the Experts in Business-Critical Continuity Introduction Given the importance of battery life to UPS system users and the fact that
FLIR i-series Point-and-Shoot Thermal Imaging Cameras
FLIR i-series Point-and-Shoot Thermal Imaging Cameras Missing insulation and water damage. Hot electrical component. Hot pipe and water leak in wall. Compact and Rugged Groundbreaking Affordability Easy
Ultrasonic Distance Meter. Operation Manual
XPROTEC Ultrasonic Distance Meter Operation Manual About XProTec Pro-Installer Tools The XProTec line from XFTP is a comprehensive lineup of professionalgrade technical tools. These full-featured, field-proven,
Dual Laser InfraRed (IR) Thermometer
User Manual Dual Laser InfraRed (IR) Thermometer MODEL 42512 Introduction Congratulations on your purchase of the Model 42512 IR Thermometer. This Infrared thermometer measures and displays non-contact
APPLICATION OF THERMAL IR IMAGERY FOR CONCRETE BRIDGE INSPECTION
APPLICATION OF THERMAL IR IMAGERY FOR CONCRETE BRIDGE INSPECTION Khatereh Vaghefi, Michigan Technological University, Houghton, MI Henrique A. de Melo e Silva, Michigan Technological University, Houghton,
Digital Energy ITI. Instrument Transformer Basic Technical Information and Application
g Digital Energy ITI Instrument Transformer Basic Technical Information and Application Table of Contents DEFINITIONS AND FUNCTIONS CONSTRUCTION FEATURES MAGNETIC CIRCUITS RATING AND RATIO CURRENT TRANSFORMER
THERMAL RADIATION (THERM)
UNIVERSITY OF SURREY DEPARTMENT OF PHYSICS Level 2 Classical Laboratory Experiment THERMAL RADIATION (THERM) Objectives In this experiment you will explore the basic characteristics of thermal radiation,
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity
Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?
Data Bulletin April 2001 Raleigh, NC, USA Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW Variable frequency drives are available from manufacturers as enclosed engineered
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
TOPIC 5 (cont.) RADIATION LAWS - Part 2
TOPIC 5 (cont.) RADIATION LAWS - Part 2 Quick review ELECTROMAGNETIC SPECTRUM Our focus in this class is on: UV VIS lr = micrometers (aka microns) = nanometers (also commonly used) Q1. The first thing
THERMAL IMAGING GUIDEBOOK
THERMAL IMAGING GUIDEBOOK FOR BUILDING and renewable energy APPLICATIONS An informative guide for the use of thermal imaging cameras for inspecting buildings, solar panels and windmills. Content 1. The
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
WINDING RESISTANCE TESTING
WINDING RESISTANCE TESTING WINDING RESISTANCE TEST SET, MODEL WRT-100 ADWEL INTERNATIONAL LTD. 60 Ironside Crescent, Unit 9 Scarborough, Ontario, Canada M1X 1G4 Telephone: (416) 321-1988 Fax: (416) 321-1991
The Three Heat Transfer Modes in Reflow Soldering
Section 5: Reflow Oven Heat Transfer The Three Heat Transfer Modes in Reflow Soldering There are three different heating modes involved with most SMT reflow processes: conduction, convection, and infrared
Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer
User Manual Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer MODEL 42515 Introduction Congratulations on your purchase of the Model 42515 IR Thermometer. The Model 42515 IR thermometer
Use your troubleshooting superpowers for good Application Note
Use your troubleshooting superpowers for good Application Note Unleash your full troubleshooting powers with innovative new tools from Fluke. You ve got skill. You ve got experience. Now you have some
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Identifying energy savings with thermal imaging
Identifying energy savings with thermal imaging Contents Summary 3 Thermal imaging how it works 4 Detecting heat loss from pipes 5 Steam trap condition monitoring 6 Finding heat loss from buildings 7 Improving
90 Degree PIR Wireless Security Sensor. Installation Instructions 5420/90F
90 Degree PIR Wireless Security Sensor Installation Instructions 5420/90F Copyright Clipsal Australia P/L 2007. All rights reserved. Clipsal is a registered trademark of Clipsal Australia Pty Ltd. The
EVALUATING WAVE FILES TO DETERMINE THE SEVERITY OF THE ULTRASONIC EMISSIONS
EVALUATING WAVE FILES TO DETERMINE THE SEVERITY OF THE ULTRASONIC EMISSIONS We are often asked at which voltages and on what type of equipment is ultrasound most effective. The answer is not simple since
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
A Method to Detect and Locate Roof Leaks Using Conductive Tapes
BEST2 Moisture Measurement Session WB8-2 A Method to Detect and Locate Roof Leaks Using Conductive Tapes ABSTRACT David Vokey, P.Eng. Detec Systems, LLC Undetected roof leaks and the subsequent deterioration
User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM
User s Guide Shop online at omega.com SM e-mail: [email protected] For latest product manuals: www.omegamanual.info OSXL-100-PE Thermal Imaging Camera Enclosure Introduction Please read this manual completely
Automated Infrared Thermography Complete Solutions from a Single Source
Automated Infrared Thermography Complete Solutions from a Single Source Temperature monitoring of processes Automatic surveying of thermal marks Early fire detection and site security Just ask the specialists...
Hygro-Thermometer + InfraRed Thermometer Model RH101
User's Guide Hygro-Thermometer + InfraRed Thermometer Model RH101 Introduction Congratulations on your purchase of the Extech Hygro-Thermometer plus InfraRed Thermometer. This device measures relative
AN11261. Using RC Thermal Models. Document information
Rev. 2 19 May 2014 Application note Document information Info Keywords Abstract Content RC thermal, SPICE, Models, Z th, R th, MOSFET, Power Analysis of the thermal performance of power semiconductors
07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
50 W Power Resistor, Thick Film Technology, TO-220
50 W Power Resistor, Thick Film Technology, TO-220 FEATURES 50 W at 25 C heatsink mounted Adjusted by sand trimming Leaded or surface mount versions High power to size ratio Non inductive element Material
Dual-Cool Notebook Cooler Pad. User s Manual
Dual-Cool Notebook Cooler Pad Model #: CF4500U User s Manual Rev. 060801 User s Record: To provide quality customer service and technical support, it is suggested that you keep the following information
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
UT202A Operating Manual. Contents
Title Contents Page Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Functional Buttons and auto power off Display Symbols
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS: INSTALLATION USE & CARE MANUAL IMPORTANT INFORMATION Assembly Instructions 2 Wiring Instructions 2 Outdoor Installation
The relationship between current load and temperature for quasi-steady state and transient conditions
The relationship between current load and temperature for quasi-steady state and transient conditions Bernard R. Lyon Jr., Gary L. Orlove, and Donna L. Peters Infrared Training Center, 16 Esquire Road,
Description. Table 1. Device summary
2 A positive voltage regulator IC Description Datasheet - production data Features TO-220 Output current up to 2 A Output voltages of 5; 7.5; 9; 10; 12; 15; 18; 24 V Thermal protection Short circuit protection
GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE
GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE ET 215:2008 ELECTRO-TECHNICAL COUNCIL OF IRELAND 2008 Page 1 of 6 Published by
TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
Applications for Infrared Thermography at Computer Centers
Applications for Infrared Thermography at Computer Centers By Eric Stockton CompuSCANIR, a division of Stockton Infrared Thermographic Services, Inc. 8472 Adams Farm Road Randleman, NC 27317 http://www.compuscanir.com/
SWITCH-MODE POWER SUPPLY CONTROLLER PULSE OUTPUT DC OUTPUT GROUND EXTERNAL FUNCTION SIMULATION ZERO CROSSING INPUT CONTROL EXTERNAL FUNCTION
SWITCH-MODE POWER SUPPLY CONTROLLER. LOW START-UP CURRENT. DIRECT CONTROL OF SWITCHING TRAN- SISTOR. COLLECTOR CURRENT PROPORTIONAL TO BASE-CURRENT INPUT REERSE-GOING LINEAR OERLOAD CHARACTERISTIC CURE
Arc flash can kill. Arc flash can be considered as a short circuit through
The Official Publication of the InterNational Electrical Testing Association Spring 2007 Methods of Inspection to Determine the Presence of Potential Arc-Flash Incidents Feature Arc flash can kill. Arc
IR Window Transmittance Temperature Dependence
IR Window Transmittance Temperature Dependence Robert P. Madding, Infrared Training Center, FLIR Systems, Inc. ABSTRACT While fluoride-type IR windows are inexpensive and have good transmittance in the
CLA4607-085LF: Surface Mount Limiter Diode
DATA SHEET CLA4607-085LF: Surface Mount Limiter Diode Applications Low-loss, high-power limiters Receiver protectors Anode (Pin 1) Anode (Pin 3) Features Low thermal resistance: 55 C/W Typical threshold
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
Technical Data Sheet 3mm Infrared LED, T-1
Technical Data Sheet 3mm Infrared LED, T-1 Features High reliability High radiant intensity Peak wavelength p=85nm 2.54mm Lead spacing Low forward voltage Pb free HIR24 Descriptions EVERLIGHT s infrared
Power Resistor Thick Film Technology
Power Resistor Thick Film Technology LTO series are the extension of RTO types. We used the direct ceramic mounting design (no metal tab) of our RCH power resistors applied to semiconductor packages. FEATURES
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
IR Edixeon Emitter. 1W Edixeon
High Power LED 1W Edixeon IR Edixeon Emitter Date:2006/06/01 Version:2.0 Device No. : 3-RD-01-E0009 Believe SRL Via Lago di Trasimeno, 21 - Schio (VI) - Italy TEL: +39/0445/579035 FAX: +39/0445/575708
Aerial Infrared Roof Moisture Surveys
Aerial Infrared Roof Moisture Surveys INTRODUCTION IR P/PM (infrared predictive/preventive maintenance) is not limited to annual infrared surveys of electrical switchgear. For instance, infrared thermography
Infrared Camera Thermal Bench Top Test Kits
Infrared Camera Thermal Bench Top Test Kits IR Camera, Optics, and Software Solutions for Saving Time and Resources Thousands of Temperature Measurements per Image Fast, Versatile Thermal Imaging and Temperature
IR Repeater. Operation Manual P8620
IR Repeater Operation Manual P8620 Congratulations on your purchase of the P8620 IR Repeater. This operating manual will provide a guide to installation and operation of the product. Please read thoroughly
1 General information
1 General information 1.1 About this manual This manual describes the installation, function and operation of an integrated solar control system, which is suitable for split pressurized solar heating system.
BB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
Expert Level Thermal Imaging Cameras
Expert Level Thermal Imaging Cameras Features & Specifications Powerful Infrared Image Integrated Digital Camera Real-Time Recording Ergonomic Viewfinder + LCD Display Accurate Measurement & Analysis Tools
Non Invasive Roof Leak Detection Using Infrared Thermography
Non Invasive Roof Leak Detection Using Infrared Thermography Scott Wood Four Star Cleaning and Restoration, Inc. ABSTRACT Residential roofs without attics are typically inspected for leaks by installing
SECTION 263235 STANDBY GENERATOR TESTING AND COMMISSIONING
SECTION 263235 STANDBY GENERATOR TESTING AND COMMISSIONING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standby generators. 2. Automatic Transfer Switches (ATS). 3. System start-up services. 4.
W- Series. Features: WOB. Mechanical Data Case : Moulded plastic. Lead : Solder plated. Weight : 1.10 grams. Page <1> 15/07/08 V1.
Features: Surge overload ratings to 40 amperes peak. Ideal for printed circuit board. Reliable low cost construction. High temperature soldering guaranteed: 260 C/10 seconds/0.375inch (9.5mm) lead lengths
Unit 4: Electricity (Part 2)
Unit 4: Electricity (Part 2) Learning Outcomes Students should be able to: 1. Explain what is meant by power and state its units 2. Discuss the importance of reducing electrical energy wastage 3. State
aseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
Infrared Viewers. Manual
Infrared Viewers Manual Contents Introduction 3 How it works 3 IR viewer in comparison with a CCD camera 4 Visualization of infrared laser beam in mid-air 4 Power Density 5 Spectral sensitivity 6 Operation