GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS



Similar documents
IMPACT DAMAGE RESISTANT WALL SYSTEMS

PB301 July Lightweight Building Solutions. Bushfire Protection.

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

FC:121 EXTERNAL CLADDING & EAVES LINING CSR CEMINTEL

FC:533 CONSTRUCTAFLOOR WET AREA FLOORING CEMINTEL RESIDENTIAL INTERNAL WET AREA FLOORING SYSTEM

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

Rockwool Flexi Insulation Application Guide

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

fire separating walls #2

H-Stud Area Separation Wall System

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

GYPSUM AREA SEPARATION FIREWALLS GA

Mark Cramer Inspection Services, Inc.

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Wet Area Construction. Carpentry - Residential Construction. Product Code: 5603

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

How To Build A Gambrel Roof And A Gable End Roof

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

CARPENTRY - HOUSING. This is the sloping length of a right-angled triangle.

Manual lifting and handling

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

PB235. Plasterboard Area Separation Walls

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

CertainTeed. Shaftliner For A rea Separation Firewalls

Excerpts from the Canadian National Building Code (NBC)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Chapter 6 ROOF-CEILING SYSTEMS

Composite Panel Firewall Systems

Residential Inspection Guidelines

The WANZ Guide to Window Installation

Water Resistant Plasterboard

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Timber Decks. Technical Note. March 2007

March 14, Installation of Bay, Bow and Garden Windows

Superform Products Ltd.

Additions and Alterations

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

PERGOLAS AND CARPORTS

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

STANDARD OPEN PATIO COVER

MUNICODE SERVICES LTD.

December J-Ply Roofing, Flooring and Decking

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing

Guide to Assessment and Repair of Flood Damaged Timber and Timber Framed Houses

Structural Assessment Report

Houses and Low Rise Multi-Residential External Walls PowerPanel XL. Design and Installation Guide NEW

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

PART 1 GENERAL 1.1 SECTION INCLUDES

Installation Window Building In Details

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

Residential Roofing Guide

Ubiflex. Non-lead flashing system

The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri

FIRE RATED GLAZING System Guide

POST AND FRAME STRUCTURES (Pole Barns)

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Connex. Mortarless Masonry Block System

Multi-layer Insulation Blanket for Roofs

Guide to Assessment and Repair of Flood Damaged Timber and Timber Framed Houses (Revised 19 th Jan 2011)

The WANZ Guide to Window Installation

Gypsum Board Systems Manual

COMMONLY USED RESIDENTIAL BUILDING CODES

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Chapter 3 Pre-Installation, Foundations and Piers

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

How To Certify The Scottsdale Construction System

Building Construction. Lightweight construction. Conventional Construction

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Guidelines for Earthquake Bracing of Residential Water Heaters

Management Consultancy Training. Asbestos Materials. Residential Guide

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

Leaky Homes Financial Assistance Package (FAP) Repair plan example

Houses External Walls PowerClad. Design and Installation Guide

Acoustic. Publication date June

FIRE AND SMOKE PROTECTION FEATURES

Fire and Acoustic. Design Manual. October 2010 / New Zealand

12.1 Schlüter -KERDI-BOARD

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Lightweight Partition Design for Residential and Commercial Buildings

FIRE AND SMOKE PROTECTION FEATURES

WorkSafe Guidance Document FALL PROTECTION IN RESIDENTIAL CONSTRUCTION

Guide to Assessment and Repair of Flood Damaged Timber and Timber Framed Houses (Revised 2 nd Feb 2013)

PANELIZED HOME INSTALLATION GUIDELINE

8/18/14. Introduction to. Framing. Terminology and Concepts

Energy Company Obligation (ECO): Technical Monitoring Questions

Best Barns USA Assembly Book

4 Installation Requirements

Building Control Guidance Note

British Gypsum Guide to Timber Frame Construction. March 1998

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Cost Guide MARKET SUMMARY OVERVIEW REPAIRS AND MAINTENANCE ELECTRICAL ROOFING & ROOF DRAINAGE (UP TO TWO STOREYS; FIXED TO EXISTING ROOF FRAME)

How To Repair A Boat Landing Deck With A Boat Bed

TECHNICAL MANUAL PLASTERBOARD SYSTEMS

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Transcription:

GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS

CONTENTS Introduction 2 Applications 3 Advantages 3 Components 3 6 Design Considerations 7 8 System Features 10 Typical installation Sequence 11 System Selection 12 13 Installation of Linings 14 Typical Construction Details 15 27 Health, Safety & Warranty 28 INTRODUCTION The CSR Gyprock Party Wall System is designed to provide a separating wall between dwellings that are side-by-side such as town houses. CSR Gyprock Party Wall comprises a double frame wall with a 25mm Shaft Liner Panel fire barrier between the frames. The basis of the fire performance is the central fire barrier, which provides the primary fire resistance, with the frame lining on each side contributing to some extent. This allows the wall linings to be installed as per normal decorative linings and to incorporate penetrations. The basis of the acoustic performance is a double cavity system. This provides impact isolation, with connections only at wall perimeters as allowed by the BCA definition of discontinuous construction. Insulation in both cavities is used to meet various performance levels, including allowance for certain penetrations and services that may occur. Contact Information 28 FIG 1: CSR GYPROCK PARTY WALL OVERVIEW Optional steel track at top of wall Gyprock Fyrchek in roof space fixed with laminating screws at 400mm max. centres Gyprock Shaft Liner Panel H-studs UNIT 1 Gyprock Fyrchek at floor level fixed with laminating screws at 400mm max. centres Steel track fastened back-to-back to support shaft liner panel at all horizontal joints UNIT 1 H-studs Timber or steel party wall frame Steel track at base and ends of wall UNIT 2 GYPROCK PARTY WALL SYSTEMS 2

APPLICATIONS CSR Gyprock Party Wall intertenancy systems are designed as separating walls for Class 1 buildings. Systems are available for steel and timber framed buildings with FRL 60/60/60 and sound ratings to meet BCA requirements. The systems have some elements that are common to the adjoining buildings, and are suitable for buildings with shared title on single allotments. Systems for other classes of buildings, buildings with separate titles and for FRL 90/90/90 are also available. Contact CSR Gyprock for information on construction for these systems. ADVANTAGES Steel and timber frame options. Systems for Rw + Ctr 50 and discontinuous construction. Linings installed as for non-rated systems. No setting joints of central fire barrier. Services simply incorporated. Minimal use of sealants. Fibre cement options in wet areas. Rapid installation. No additional trades. COMPONENTS Linings Gyprock Shaft Liner Panel Features Machine made sheet composed of a glass fibre reinforced gypsum core encased in a heavy duty liner board. 25mm thick with a mass of approximately 19.8kg/m2 Applications Fire rated separating walls and service shafts. Gyprock Fyrchek Features Suitable for wall and ceiling systems where a fire rating is to be achieved, or where acoustic performance is required. Composed of a specially processed glass fibre reinforced gypsum core encased in a heavy duty pink liner board. Long edges are recessed for flush jointing. Applications Fire rated walls and ceilings. High performance acoustic rated walls and ceilings. Gyprock Fyrchek MR Features A fire rated board with moisture resistant properties. Primarily intended for walls and ceilings in wet areas and for protected soffits and external eaves which must also achieve fire resistance. Both the core and the liner board are treated in manufacture to withstand the effects of high humidity and moisture. Long edges are recessed for flush jointing. Applications Walls and ceilings in wet areas and for protected soffits and external eaves which must also achieve fire resistance. Gyprock Aquachek Features Specially processed plasterboard. Both the core and linerboard facing are treated in manufacture to withstand the effects of moisture and high humidity. Manufactured to the requirements specified in American Society for Testing and Materials C630. For use as a wall and ceiling lining in wet areas and high moisture areas in residential and commercial applications. Recessed edges allow flush jointing to Recessed Edge Plasterboard. Applications Gyprock Aquachek is a suitable substrate for ceramic tiles. Usage areas include bathrooms, kitchens, laundries. garages and ceiling applications such as walkways and verandahs. The Gyprock Aquachek Wet Area Lining System is suitable for walls in high, medium and low risk level wet areas as defined in AS3740. GYPROCK PARTY WALL SYSTEMS 3

Gyprock Standard Plasterboard Features Recessed long edges to assist in producing smooth even and continuous surface once jointed. Square edge and square edge/ recessed edge also available. 10mm and 13mm thickness. Manufactured to the requirements specified in AS2588 : 1998 Gypsum Plasterboard. Applications Internal walls and ceilings. Gyprock Superchek Features 10mm plasterboard with denser core and heavy duty facing material. Resists double the force to impose a discernable surface indentation compared to standard plasterboard. Denser core for sound resistance. Walls lined with Superchek provide a clearly noticeable, 15% reduction in perceived loudness compared to standard plasterboard. CSRG-2011 GECA 04-2011 PANEL BOARDS Applications High traffic areas such as hallways, stairways, playrooms and garages. CeminSeal Wallboard Features CeminSeal Wallboard Sheet conforms to the requirements of AS2908.2 : 1992 Cellulosecement products Part 2: Flat sheets. Type B, Category 3. Features an embedded micro waterblock technology that prevents water penetrating into the sheet, repelling water and providing a more stable sheet. Long edges are recessed to enable seamless jointing. In accordance with the Building Code of Australia, Part 3.7.1.2, Cemintel fibre cement sheets can be used wherever noncombustible material is required by the code. Applications Wet area such as bathrooms, laundries and semi-exposed ceilings and soffits. Impact resistant walls. Gyprock Soundchek Features Designed to provide enhanced acoustic resistance in wall and ceiling systems. A machine made sheet composed of a high density gypsum core encased in a heavy duty linerboard. Long edges are recessed to assist in producing a smooth, even and continuous surface once jointed. 13mm thickness. Manufactured to the requirements specified in AS2588 : 1998 Gypsum Plasterboard. Applications Internal walls where a higher sound rating is required. TABLE 1: GYPROCK PRODUCT WEIGHTS Colour shading behind each product approximates the colour of the product face liner sheets. For detailed sheet sizes and availability, contact the CSR Gyprock Sales Centre in your region or refer to www.gyprock.com.au Gyprock Lining Products Standard Plasterboard Recessed Edge Standard Plasterboard Square Edge Standard Plasterboard Recessed Edge/Square Edge Thickness mm Mass kg/m2 10 6.5 13 8.5 10 6.5 13 8.5 10 6.5 Supaceil 10 6.1* Soundchek 13 13.0 10 8.0 Aquachek 13 10.4 Impactchek 13 10.3 Superchek 10 10.4 EC08 Partition 13 9.3 EC08 Fire 13 10.5 EC08 Impact 13 12.1 Flexible 6.5 4.25 13 10.5 Fyrchek 16 12.5 13 10.7 Fyrchek MR 16 13.5 Perforated Sheet 13 10.0 Shaft Liner Panel 25 19.8 * 6.5kg/m 2 available in Western Australia Cemintel Fibre Cement Product Thickness mm Mass kg/m2 CeminSeal Wallboard 6 9.7 CeminSeal Wallboard 9 14.3 GYPROCK PARTY WALL SYSTEMS 4

Fasteners Gyprock Plasterboard Laminating Screw: 40mm x Nº10.for fixing 16mm Gyprock Fyrchek plasterboard to Shaft Liner Panels. Order Nº Pack Qty 12215 1000 Drill-point wafer-head screw: 10g x 16mm, for joining steel track back-to-back, for fixing Wall Clip to H-Stud, and for fixing wall clip to steel frame. Order Nº Pack Qty 39367 1000 40914 100 Drill-point wafer-head screw: 10g x 30mm for fixing Wall Clip to H-Stud through Gyprock Fyrchek plasterboard. Order Nº Pack Qty 39368 1000 40915 100 Needle-point screw: 6g x 25mm for fixing Wall Clip to timber plate. Insulation Bradford Gold R1.5 wall batts (75mm). Bradford Gold R2.0 wall batts (75mm). Bradford Gold R2.0 wall batts (90mm). Bradford Gold R2.7 wall batts (90mm). Bradford SoundScreen R1.6 batts (60mm). Bradford SoundScreen R2.0 batts (75mm). Bradford Glasswool Partition batts 11kg/m 3 (75mm). Bradford Glasswool Partition batts 14kg/m 3 (75mm). Bradford Glasswool Partition batts 11kg/m 3 (110mm). Cavity Seal. Bradford rockwool batts (eg; Soundscreen or Fibretex 350) lightly compressed into the cavity being sealed. Steel H-Stud The Gyprock Party Wall System incorporates 25mm H-Studs to support the Shaft Liner Panels at all vertical joints. It is made from 0.55mm BMT G275 galvanised steel. Order Nº Length 39156 3000mm Order Nº Pack Qty 12234 1000 Nails: 2mm x 25mm hot-dip galvanised for fixing Wall Clip to timber plate. Order Nº Pack Qty 11332 2.5kg 12786 0.5kg Track fasteners: Must be steel e.g. Power actuated concrete nails, flat or round head expansion anchors. Sealants Gyprock Wet Area Acrylic Sealant: Order Nº Pack Qty 10902 450g tube Gyprock Fire Mastic: Order Nº Pack Qty 10924 600ml tube 34mm 25mm GYPROCK PARTY WALL SYSTEMS 5

Steel Track Steel track (Rondo NºP140) is used in the following applications: Support of Shaft Liner Panels at the top and the bottom of the wall. Support of Shaft Liner Panels at the ends of the wall. Used back to back at all horizontal joints in Shaft Liner Panels. Order Nº Length 10465 3000mm Wall Clip Aluminium Wall Clip: Used to support the 25mm H-Stud, and are critical in the fire performance of systems with a single 25mm Shaft Liner. They are manufactured from 1.6mm aluminium. Order Nº Pack Qty 81408 1 Aluminium Strap: Used as an alternative to wall clips at wall ends (supply by others) minimum size 50x90x1.6mm Gyprock Folding Track may be used as an alternative for ease of installation. Order Nº Length 74014 3000mm Restraint tab Fold line 50 Slot for screw fixing (where noted) 28mm Galvanised Track - Rondo Part NºP140 0.55mm BMT 28mm 25 50 H Studs extend into horizontal steel tracks 40mm Continuous steel track fixed back to back at all horizontal joints 90mm Wall Clip 50mm GYPROCK PARTY WALL SYSTEMS 6

DESIGN CONSIDERATIONS Building Design CSR Gyprock Party Wall systems consist of vertically spanning elements extending from the ground slab or footing up to the roof. It may not be possible to start the Party Wall systems over a void or above cavity masonry while maintaining both fire and acoustic ratings. Consideration of roof framing is also important to avoid penetrating the fire barrier with trusses, ties, hip beams, etc. Details are provided to allow the adjoining houses to be offset in height, with the higher level walls treated as fire rated external walls. CSR Party Wall systems are ideally suited to buildings with aligned facades, A detail for an off-set brick veneer facade is provided. The maximum height for the Shaft Liner Panel fire barrier is 12m, with a maximum individual floor/ceiling height of 3m. FIG 3: PARTY WALL SUPPORT ARRANGEMENTS Gyprock Party Wall Gyprock Party Wall Gyprock Party Wall is not suitable for unsupported areas Light weight floor Gyprock Party Wall is only suitable for areas where the fire barrier is continuous from foundation level to roof level FIG 2: MAXIMUM PANEL AND WALL HEIGHT DETAILS 3.0m max. panel height 3.0m max. panel height 6.0m max. Structural Design All walls must be designed for the applied loads. Timber framing shall be in accordance with AS1684 or AS1720.1 and steel framing shall be designed to AS/NZS 4600 or AS 3623. H-Studs must be restrained at top and bottom to frames on each side of the barrier with wall clips spaced at 3m maximum centres. Wall clips must be placed a maximum 600mm below the top of a H-Stud. The building designer must ensure load-bearing walls have been designed assuming no contribution to axial strength from the wall linings. Gyprock Party Wall Systems may be exposed to wind during construction for up to three months during construction, for wind zones N1 and N2. For higher wind loads or longer exposure, the H-Studs must be adequately propped until the building is enclosed. Fire Resistance The Gyprock Party Wall systems in this manual have been assessed by Exova Warrington Fire in accordance with the general principles of AS1530.4. They are suitable for the stated FRL when designed in accordance with the building and structural considerations above, and installed in accordance with the details in this manual. The systems are designed for one side to collapse in a fire, leaving the central barrier and the opposing wall in place. In areas such as the roof space and between floor and ceiling where there are no stud linings, 16mm Fyrchek plasterboard is laminated to the Shaft Liner to maintain the rating. The aluminium clips used in single Shaft Liner systems are intended to melt on the fire side only, allowing collapse without damage to the remaining system. For all systems, penetrations may be made in Shaft Liner GYPROCK PARTY WALL SYSTEMS 7

Panels in the roof space only, and must be fire sealed to suit the system fire rating. Systems lined with Cemintel Wallboard must include Bradford glasswool or rockwool insulation to each frame to achieve the stated fire resistance. Acoustic Performance The acoustic performance of wall systems is expressed in terms of Rw and Rw+Ctr. The systems have been assessed by PKA Acoustic Consulting, and the ratings refer to expected laboratory performance. The site performance of the systems may be affected by sound flanking, the effectiveness of workmanship, and the inclusion of structural elements and bridging items. The building designer must pay special attention to airborne and structural flanking paths to minimise the difference between laboratory and field performance. Wall clips are only to be installed at or within floor and ceiling zones as shown in the details. Using additional clips within the storey height will reduce the acoustic performance of the wall, and the wall will not meet the requirement for discontinuous construction. For flanking sound control, it is required that each story ceiling consists of plasterboard 10mm or thicker, and that insulation extends 1200mm minimum on each side of the wall over the ceiling. The insulation is to be glasswool or rockwool 75mm or thicker, such as Bradford R1.5 Gold batts. There must be no penetration to the ceiling in rooms adjacent to the Party Wall, unless they have effective acoustic treatment. It is assumed no rating is required between the two adjoining roof spaces and that the spaces are not able to be occupied. It is proposed that the detail is an alternative solution based on BCA Part1 F5.5(e) + (f), to be confirmed by the certifier. All systems achieve Rw > 45 and Rw + Ctr > 40 for services in the adjoining unit. Substitution Plasterboard linings and barriers, and fibre cement linings, must be as specified in the system and be supplied by CSR. No statement of performance will be provided by CSR when other brand products are used. Wallboard & Plasterboard Fixing Once erected, it is recommended that the central barrier of Gyprock Shaft Liner Panels and Fyrchek plasterboard are protected from rain. The use of suitable sheeting can prevent the formation of mould, and avoid delays in allowing boards to dry before internal linings are applied. In any case, the central barrier may be left exposed to weather for up to one month if required. Walls may be built to achieve a particular Level of Finish as defined in AS/NZS2589.1. The Level of Finish specified can have requirements for frame alignment, jointing and back blocking methods, and sheet orientation. CeminSeal Wallboard and Gyprock plasterboard may be installed vertically or horizontally, although for some Levels of Finish horizontal sheeting must be used. Walls lined with Gyprock plasterboard or CemintSeal Wallboard may be finished with tiles. Refer to the appropriate installation manual. Services CSR Gyprock Party Wall systems allow penetrations for plumbing and electrical services to be installed without the need for acoustic caulking, baffles or fire seals. The penetrations may be made in the stud wall linings and backto-back services are permitted. Systems have been fire tested with services including PVC (65mm max. diameter), copper plumbing, and electrical services installed in both wall leaves with acceptable performance. Services may be installed through the stud framing or, with a minimum 10mm clearance to the central Shaft Liner barrier, may be fixed to the back of studs. Simply prepare neat cut holes with a 6mm maximum clearance. No fire or acoustic sealant is required at junction of shaft liner panel with H-Studs or between the track and an even floor slab. No fire caulking is required in the outer linings. No penetrations are permitted through the central fire barrier, except within the roof space where they must be fire sealed. Wet Area Systems The stud linings on one side of a system may be substituted with the linings from another system to create an asymmetric system. This might occur, for example, where a wet area in one unit is adjacent to a habitable area of an adjoining unit. The fire and acoustic performance of the asymmetric system shall be taken as the lower of the values of the two systems that were combined. Alternatively systems may be modified for use in wet areas by substituting wet area board. For example, use 2 x 10mm Gyprock Aquachek in lieu of 2 x 10mm Gyprock Standard Plasterboard. GYPROCK PARTY WALL SYSTEMS 8

FIG 4: TYPICAL APPLICATIONS CLASS 1 BUILDINGS 450mm parapet for combustable roof coverings Separating wall continued up to underside of non-combustible roof Separating wall continued down to ground Fire rated Wall above lower roof Dwelling 1 Dwelling 2 Dwelling 3 Dwelling 4 Dwelling 5 Suspended floor Dwelling 9 Dwelling 10 Dwelling 6 Dwelling 7 Dwelling 8 Private garages may be under or within class 1a dwelling Gyprock Party Wall GYPROCK PARTY WALL SYSTEMS 9

SYSTEM FEATURES For systems with FRL 60/60/60, penetrations such as plumbing and electrical services can be installed without the need for acoustic caulking, baffles or complex details. The penetrations may be made in the stud wall linings and back-to-back services are permitted. No penetrations are permitted through the central fire barrier outside the roof space. Systems have been fire tested with services including PVC (65mm max. diameter), copper plumbing, and electrical services installed in both wall leaves with acceptable performance. No fire caulking is required in the outer linings. Simply prepare neat cut holes with a 6mm clearance. No fire or acoustic sealant is required at junction of shaft liner panel with H-Studs or between the track and an even floor slab. For all systems, penetrations may be made in Shaft Liner Panels in the roof space, and must be fire sealed to suit the system fire rating. FIG 5: TYPICAL PENETRATION FEATURES Services may penetrate stud wall lining without fire caulking. Use flexible sealant to suit waterproofing requirements CeminSeal Wallboard or Gyprock MR plasterboard to wet areas Services must have a 10mm clearance to, and not be fixed to, the fire barrier Gyprock Shaft Liner Panel (no penetration permitted through this lining except in roof space) GYPROCK PARTY WALL SYSTEMS 10

TYPICAL INSTALLATION SEQUENCE FIG 6: GROUND FLOOR FIRE BARRIER INSTALLED Steel track fastened back-to-back to support shaft liner panel at all horizontal joints Gyprock Fyrchek at floor level fixed with laminating screws at 400mm max. centres FIG 8: FIRST FLOOR FIRE BARRIER INSTALLED Optional steel track at top of wall Gyprock Fyrchek in roof space fixed with laminating screws at 400mm max. centres UNIT 1 UNIT 1 Gyprock Shaft Liner Panel H-studs Gyprock Shaft Liner Panel UNIT 1 UNIT 2 H-studs Timber or steel party wall frame Steel track at base and ends of wall UNIT 2 UNIT 1 UNIT 2 FIG 7: UNIT 2 FRAME AND FLOOR INSTALLED FIG 9: UNIT 2 FIRST FLOOR FRAMING INSTALLED UNIT 1 UNIT 1 UNIT 2 UNIT 2 Timber or steel party wall frame UNIT 1 UNIT 1 UNIT 2 UNIT 2 GYPROCK PARTY WALL SYSTEMS 11

SYSTEM SELECTION Timber Frame Internal Wall Systems Party Wall with 25mm Fire Barrier SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 362a shown) ACOUSTIC OPINION PKA-018 Lining material as per system table. Timber studs at 600mm maximum centres. Cavity insulation as per system table. 20-40mm separation between frame and Gyprock Shaft Liner Panel. 25mm Gyprock Shaft Liner Panel between steel H-Studs at 600mm maximum centres. 20-40mm separation between frame and Gyprock Shaft Liner Panel. Cavity insulation as per system table. Timber studs at 600mm maximum centres. Lining material as per system table. Discontinuous Construction FRL Report/Opinion SYSTEM Nº CSR 360 WALL LININGS STUD DEPTH mm 70 90 CAVITY INFILL Both sides Rw / Rw+Ctr (Refer to Section A ) (a) 75 Gold Batts 2.0 60/47 61/49 60/60/60 EWFA 45743 BOTH SIDES 1 x 10mm Gyprock Superchek. (b) 90 Gold Batts 2.7 61/48 62/50 (c) 88 Soundscreen 2.5 61/48 62/50 WALL THICKNESS mm 225 265 CSR 361 (a) 75 Gold Batts 2.0 61/49 62/50 60/60/60 EWFA 45743 BOTH SIDES 2 x 10mm Gyprock Standard Plasterboard. (b) 90 Gold Batts 2.7 62/50 63/51 (c) 88 Soundscreen 2.5 62/50 63/51 WALL THICKNESS mm 245 285 CSR 362 (a) 75 Gold Batts 2.0 61/49 62/50 60/60/60 EWFA 45743 BOTH SIDES 1 x 13mm Gyprock Soundchek. (b) 90 Gold Batts 2.7 62/50 63/51 (c) 88 Soundscreen 2.5 62/50 63/51 WALL THICKNESS mm 231 271 CSR 363 BOTH SIDES (ANY ORDER) (a) 75 Gold Batts 2.0 62/50 63/51 60/60/60 EWFA 45743 1 x 6mm CeminSeal Wallboard. 1 x 10mm Gyprock Aquachek plasterboard. (b) 90 Gold Batts 2.0 62/50 63/51 (c) 88 Soundscreen 2.5 63/51 64/52 WALL THICKNESS mm 237 277 CSR 364 BOTH SIDES (ANY ORDER) (a) 75 Gold Batts 1.5 61/49 62/50 60/60/60 EWFA 45743 1 x 10mm Gyprock Superchek plasterboard. 1 x 10mm Gyprock Standard Plasterboard. (b) 90 Gold Batts 2.0 62/50 63/51 (c) 88 Soundscreen 2.5 63/51 64/52 WALL THICKNESS mm 245 285 GYPROCK PARTY WALL SYSTEMS 12

Steel Frame Internal Wall Systems Party Wall 25mm Fire Barrier SYSTEM SPECIFICATION TYPICAL LAYOUT (CSR 100a shown) ACOUSTIC OPINION Lining material as per system table. Steel studs at 600mm maximum centres. Cavity insulation as per system table. 20-40mm separation between frame and Gyprock Shaft Liner Panel. 25mm Gyprock Shaft Liner Panel between steel H-Studs at 600mm maximum centres. 20-40mm separation between frame and Gyprock Shaft Liner Panel. Cavity insulation as per system table. Steel studs at 600mm maximum centres. Lining material as per system table. PKA-052 Discontinuous Construction FRL Report/Opinion SYSTEM Nº WALL LININGS CAVITY INFILL (Both Sides) (Refer to Section A ) STUD DEPTH mm 64 76 Rw / Rw+Ctr CSR 100 (a) 75 GW Partition 14kg 60/48 61/49 60/60/60 EWFA 45743 BOTH SIDES 2 x 10mm Gyprock Standard Plasterboard. (b) 110 GW Partition 11kg (c) 88 RW Soundscreen R2.5 62/50 61/49 62/50 62/50 MINIMUM WALL THICKNESS mm 257 289 CSR 101 (a) 75 GW Partition 14kg 62/50 62/51 60/60/60 EWFA 45743 BOTH SIDES 2 x 13mm Gyprock Standard Plasterboard. (b) 110 GW Partition 11kg (c) 88 RW Soundscreen R2.5 63/52 63/51 63/52 63/52 MINIMUM WALL THICKNESS mm 269 301 CSR 102 (a) 75 GW Partition 14kg 60/48 61/49 60/60/60 EWFA 45743 BOTH SIDES 1 x 13mm Gyprock Soundchek. (b) 110 GW Partition 11kg (c) 88 RW Soundscreen R2.5 62/50 61/49 62/50 62/50 MINIMUM WALL THICKNESS mm 243 275 CSR 103 60/60/60 EWFA 45743 BOTH SIDES 1 x 6mm CeminSeal Wallboard. 1 x 10mm Gyprock Aquachek. (a) 75 GW Partition 11kg (b) 75 GW Partition 14kg (c) 88 RW Soundscreen R2.5 61/49 62/50 63/51 61/50 62/51 63/52 MINIMUM WALL THICKNESS mm 249 281 GYPROCK PARTY WALL SYSTEMS 13

INSTALLATION OF LININGS Internal lining systems must be installed in accordance with the relevant installation manuals. The first layer of any double layer system must be fixed using the all fastener method. TABLE 2: WALL LINING FIXING METHODS Lining Application Fixing Manual Notes 10mm Superchek 13mm Soundchek General areas GYP547 (timber studs) GYP544 (steel studs) Adhesive/Fastener fixing. or Full fastener fixing (screws or nails). 6mm CeminSeal Wallboard Wet areas and General areas FC101 Tiled areas: All fastener fixing. Non-tiled areas: Adhesive/ Fastener or all fastener fixing. 10 13mm Aquachek Wet areas GYP547 (timber studs) GYP544 (steel studs) Tiled areas: All fastener fixing. Non-tiled areas: Adhesive/ Fastener or all fastener fixing. GYPROCK PARTY WALL SYSTEMS 14

TYPICAL CONSTRUCTION DETAILS FIG 10: BASE DETAIL AT SLAB FIG 12: BASE DETAIL AT FRAMED FLOOR Refer to System Table for wall lining and insulation 20-40mm gap on each side Steel or Timber studs 20-40mm gap on each side Timber or steel stud wall framing 25mm Gyprock Shaft Liner Panel between steel H studs at 600mm centres 25mm Gyprock Shaft Liner Panel with steel H-studs at vertical panel joints Refer to System Table for wall lining and insulation Timber or steel subfloor members Timber or steel subfloor members Fire Mastic only required at gaps Steel track fixed to concrete slab at 150mm max. from ends and 600mm max. centres between Continuous strip of 16mm Gyprock Fyrchek screw laminated to Gyprock Shaft Liner Panel Concrete slab Concrete or masonry wall with FRL equal to Gyprock Party Wall above. Dampcourse and termite barrier as required FIG 11: ALTERNATE BASE DETAIL Tip: For steel wall framing, clips may be fixed to a short section of inverted track. 20-40mm gap on each side Steel or Timber studs Inverted Track 25mm Gyprock Shaft Liner Panel with steel H-studs at vertical panel joints Refer to System Table for wall lining and insulation Wall Clip Fire Mastic only required at gaps Wall Clips fixed at each H-Stud Base Track Concrete slab GYPROCK PARTY WALL SYSTEMS 15

FIG 13: DETAIL AT UPPER STOREY FRAMED FLOOR 20-40mm gap on each side 4mm min. 16mm Gyprock Fyrchek screw laminated to one side (can be on either side of shaft liner panel). Butt together neatly at sheet joins 200mm min. Continuous steel track fixed back to back at 600mm max. centres Floor joists may be perpendicular or parallel to wall Alternative clip location Optional insulation 600mm max. from clip to joint in shaft liner panel Additional nogging at each clip Refer to Party Wall System Table for insulation and wall linings Gyprock Shaft Liner Panel with H-Studs at panel joints 200mm min. Floor joists may be perpendicular or parallel to wall Timber or steel studs Optional insulation NOTE: No additional clips to be placed within storey height Wall Clips at each H-Stud on both sides of wall FIG 14: DETAIL FOR STEEL COLUMN AND BEAM SUPPORT 20-40mm gap on each side 4mm min. 16mm Gyprock Fyrchek screw laminated to one side (can be on either side of shaft liner panel). Butt together neatly at sheet joins Floor joists 200mm min. Continuous steel track fixed back to back at 600mm max. centres Steel floor beam 600mm max. Optional insulation Floor joists may be perpendicular or parallel to wall Steel loadbearing column within wall cavity 200mm min. Optional insulation Refer to Party Wall System Table for insulation and wall linings Gyprock Shaft Liner Panel with H-Studs at panel joints Wall Clips at each H-Stud on both sides of wall (fixed to additional nogging where required Timber or steel studs GYPROCK PARTY WALL SYSTEMS 16

FIG 15: DETAIL AT EXTERNAL TIMBER FRAME WALL Insulation External cladding system fixed to studs Refer to System Table for wall lining and insulation 10mm Gyprock Standard Plasterboard Wall Clips at each H-Stud and ends, both sides Required acoustic insulation, minimum R1.5 Bradford Gold batts Wall clips or straps at wall end Control joint opposite Gyprock Shaft Liner Panel Timber or steel stud wall framing Rondo P140 track vertically at outer ends of wall (seal to cladding with Gyprock Fire Mastic) 10mm Gyprock Standard Plasterboard Insulation Required acoustic insulation, minimum R1.5 Bradford Gold batts Sarking as required FIG 16: DETAIL AT EXTERNAL STEEL FRAME WALL External cladding system fixed to studs (thermal break may be required) Refer to Party Wall System Table for wall linings and insulation 10mm Gyprock Standard Plasterboard Wall Clips at each H-Stud, both sides Required acoustic insulation, minimum R1.5 Bradford Gold batts Wall clips or straps at wall end Steel stud wall framing Steel angle 35x35mm or additional stud for plasterboard fixing Rondo P140 track vertically at outer ends of wall (seal to cladding with Gyprock Fire Mastic) Required acoustic insulation minimum R1.5 Bradford Gold batts Sarking as required GYPROCK PARTY WALL SYSTEMS 17

FIG 17: PARTY WALL PROJECTION WITH LIGHT WEIGHT FACADE Refer to System Table for wall lining and insulation Optional insulation 10mm Gyprock Standard Plasterboard Wall Clips at each H-Stud, both sides For frame projection limit refer to project engineer External cladding system Aluminium straps may be used in lieu of clips Timber or steel stud wall framing 10mm Gyprock Standard Plasterboard Optional insulation Rondo P140 track vertically at outer ends of wall (seal to cladding with Gyprock Fire Mastic) FIG 18: PARTY WALL SECTION WITH LIGHT WEIGHT FACADE WITH ALUMINIUM STRAPS Refer to system table for wall linings and insulation Timber or steel stud wall framing Rondo P140 track vertically at outer ends of wall (seal to cladding with Gyprock Fire Mastic) Aluminium straps may be used in lieu of clips (Typical strap layout) GYPROCK PARTY WALL SYSTEMS 18

FIG 19: DETAIL AT EXTERNAL BRICK VENEER WALL Required acoustic insulation, minimum R1.5 Bradford Gold batts Brick veneer 10mm Gyprock Standard Plasterboard Refer to System Table for wall lining and insulation Wall Clips at each H-Stud, both sides Control joint opposite Gyprock Shaft Liner Panel 150mm min. Rockwool cavity seal Timber or steel stud wall framing Required acoustic insulation, minimum R1.5 Bradford Gold batts 10mm Gyprock Standard Plasterboard Rondo P140 track vertically at outer ends of wall Aluminium straps Sarking. 1. For walls without sarking, protect the cavity seal with damp course against the brickwork 2. Cavity Seal may be inside sarking FIG 20: DETAIL AT RETURN IN BRICK VENEER WALL Optional insulation Brick veneer 10mm Gyprock Standard Plasterboard Refer to System Table for wall lining and insulation Required acoustic insulation, minimum R1.5 Bradford Gold batts Wall Clips at each H-Stud, both sides 150mm wide Rockwool cavity seal Sarking. 1. For walls without sarking, protect the cavity seal with damp course against the brickwork 2. Cavity Seal may be inside sarking Timber or steel stud wall framing Rondo P140 track vertically at outer ends of wall with wall clips or wall straps both sides 10mm Gyprock Standard Plasterboard GYPROCK PARTY WALL SYSTEMS 19

FIG 21: DETAIL AT CEILING AND ROOF Non-combustible roofing Nominal 10mm gap to top of Gyprock Shaft Liner Panel (track optional) Battens may be continuous over party wall. Refer to BCA requirements Roof battens Roof framing Fill void between battens with Rockwool cavity seal, 300mm min. width Roof sarking. For roofs without sarking, protect Rockwool with Wall Clips at damp course under tiles each H-Stud both sides of wall 16mm Gyprock Fyrchek laminated to Gyprock Shaft Liner Panel with laminating screws at 400mm x 400mm max. centres Blocking to support ceiling lining 600mm max. Wall Clips at each H-Stud both sides of wall 200mm min. Required acoustic insulation minimum 75mm Bradford R1.5 Gold batts Required acoustic insulation minimum 75mm Bradford R1.5 Gold batts 4mm minimum gap Gyprock Shaft Liner Panel Refer to Party Wall System Table for wall lining and insulation 20-40mm gap each side of wall FIG 22: INSTALLATION DETAIL FOR FYRCHEK LAMINATION 25mm Gyprock Shaft Liner Panel 75mm min. H-Stud 16mm Gyprock Fyrchek laminated to Shaft Liner Panel 100mm max. 400mm max. 400mm max. Setting of joints is not required 100mm max. GYPROCK PARTY WALL SYSTEMS 20

FIG 23: DETAIL AT ROOF/CEILING AND VALLEY GUTTER 25mm gap over Gyprock Shaft Liner Panel Optional track along top of Gyprock Shaft Liner Panel Fill void at top of wall with Rockwool cavity seal Required acoustic insulation minimum 75mm Bradford R1.5 Gold batts Required acoustic insulation minimum 75mm Bradford R1.5 Gold batts Timber packing to suit Extended bottom chord to trusses (refer to truss supplier) Blocking 45mm thick between trusses Wall Clips at each H-Stud on both sides of wall Gyprock Shaft Liner Panel Refer to Party Wall System Table for wall lining and insulation FIG 24: DETAIL AT STEPPED ROOF External cladding system and battens Flashing and sarking to building designer s details Roofing Sarking 16mm Gyprock Fyrchek MR Refer to system CSR 900 for details Fill void at top of wall with Rockwool cavity seal Sarking 100mm min. 300mm max. Note: FRL of external wall has load limitations. Refer to CSR 900 for details. Wall Clips at each H-Stud, both sides of wall. 16mm Gyprock Fyrchek Gyprock Shaft Liner Panel 200mm min. Refer to Party Wall System Table for wall lining and insulation GYPROCK PARTY WALL SYSTEMS 21

FIG 25: DETAIL AT ROOF/CEILING Roof battens Nominal 10mm gap to top of Gyprock Shaft Liner Panel (track optional) Fill void between battens with Rockwool cavity seal, 300mm min. width Non-combustible roofing Roof sarking. For roofs without sarking, protect Rockwool with damp course under tiles Roof framing Wall Clips at each H-Stud both sides of wall 600mm max. 16mm Gyprock Fyrchek laminated to Gyprock Shaft Liner Panel with laminating screws at 400mm x 400mm max. centres Wall Clips at each H-Stud both sides of wall 200mm min. Required acoustic insulation minimum 75mm Bradford R1.5 Gold batts Required acoustic insulation minimum 75mm Bradford R1.5 Gold batts 4mm minimum gap Gyprock Shaft Liner Panel Refer to Party Wall System Table for wall lining and insulation 20-40mm gap each side of wall GYPROCK PARTY WALL SYSTEMS 22

FIG 26: DETAIL AT ROOF/CEILING AND PARAPET Optional track along top of Gyprock Shaft Liner Panel Parapet capping Fill void at top of wall with Rockwool cavity seal Wall Clips at all H-Studs, both sides of wall Required acoustic insulation minimum Bradford R1.5 Gold batts Required acoustic insulation minimum Bradford R1.5 Gold batts 200mm min. 45mm min. thick ledger with joist hanger Wall Clips at each H-Stud, both sides of wall. Loadbearing timber wall frame both sides 16mm Gyprock Fyrchek laminated to Gyprock Shaft Liner Panel with laminating screws at 400mm x 400mm max. centres Refer to Party Wall System Table for wall lining and insulation Gyprock Shaft Liner Panel GYPROCK PARTY WALL SYSTEMS 23

FIG 27: DETAIL FOR OFFSET ROOF Track optional Capping and flashing to project specifications Fill void between battens with Rockwool cavity seal Roof framing Roof battens Roof sarking Wall Clips at each H-Stud both sides of wall 16mm Gyprock Fyrchek laminated to Gyprock Shaft Liner Panel, fixed with laminating screws at 400 x 400mm max. centres Non-combustible roofing 600mm max. from clips Blocking to support ceiling lining Wall Clips at each H-Stud Required acoustic insulation minimum 75mm Bradford R1.5 Gold batts 4mm minimum gap 20-40mm gap each side of wall 1 x 25mm Gyprock Shaft Liner Panel in H-stud framing Refer to System Specification for wall lining and insulation Required acoustic insulation minimum 75mm Bradford R1.5 Gold batts Wall Clips at each H-Stud fixed to noggings 200mm min. GYPROCK PARTY WALL SYSTEMS 24

FIG 28: EAVES DETAIL (SIDE ELEVATION) Leave 10mm gap between top of fire barrier and underside of battens and fill all gaps with Rockwool cavity seal P140 track continuous and fixed to next H-stud Gyprock Shaft Liner Panel within framing formed with P140 steel track H studs at 600mm max. cts for eaves over 600mm high or over 1200mm wide Wall clips each side of fire barrier fixed to P140 track and ends of rafters Rafter or truss Non-combustible roofing Non-combustible anti-ponding board with sarking over (sarking not shown for clarity Screw fix through fascia and track P140 track Soffit bearer Screw fix all connections Eaves lining Bradford Rockwool Cavity Seal, full height of cladding and fill gap above cladding Wall clip each side of party wall fixed to P140 track and studs Gyprock Party Wall System Party Wall Framing each side of fire barrier Sarking FIG 29: EAVES DETAIL (OUTSIDE END ELEVATION) Non-combustible roofing material Non-combustible anti-ponding board with sarking over Completely fill all gaps between roofing and top of fire barrier with Rockwool cavity seal to 150mm min. each side Fascia board Wall clips each side of fire barrier fixed to P140 track and ends of rafters Rafter P140 track Fascia board Soffit bearer CeminSeal Eaves Lining Sheet P140 track to outer end of Gyprock Shaft Liner Panel GYPROCK PARTY WALL SYSTEMS 25

FIG 30: DETAIL FOR JUNCTION OF GYPROCK PARTY WALL AND NON FIRE-RATED WALL TIMBER STUD PLAN VIEW Refer to Party Wall System Table for wall lining and insulation Wall Clips at each H-Stud, both sides of wall FIG 33: DETAIL FOR JUNCTION OF GYPROCK PARTY WALL AND NON FIRE-RATED WALL STEEL STUD PLAN VIEW Refer to Party Wall System Table for wall lining and insulation Wall Clips at each H-Stud, both sides of wall Timber stud wall framing Non fire-rated wall Insulation in this zone to be rockwool or glasswool only Non fire-rated wall Steel angle for fixing plasterboard 600mm min. Min. R1.5 Glasswool or R1.6 Rockwool to 600mm min. from Party Wall Steel stud wall framing FIG 31: ALTERNATIVE DETAIL FOR JUNCTION OF GYPROCK PARTY WALL AND NON FIRE-RATED WALL STEEL STUD PLAN VIEW Refer to Party Wall System Table for wall lining and insulation Wall Clips at each H-Stud, both sides of wall Plasterboard continuous though Steel stud wall framing FIG 32: DETAIL AT CORNER PLAN VIEW Gyprock Shaft Liner Panel Refer to System Table for wall lining and insulation Refer to System Table for wall lining and insulation Wall Clips at each H-Stud, both sides Wall Clip at first floor height Timber or steel stud wall framing GYPROCK PARTY WALL SYSTEMS 26

FIG 34: ROOF VOID DETAIL WITH HORIZONTAL SHEETING (FRONT ELEVATION) Wall clips at 600mm max. centres, both sides of wall 16mm Gyprock Fyrchek laminated to Gyprock Shaft Liner Panel with laminating screws at 400mm x 400mm max. centres 600mm max. Gyprock Shaft Liner Panel installed vertically Gyprock Shaft Liner Panel installed horizontally Back to back H-Studs installed horizontally Truss chord 100mm max. Gyprock Shaft Liner Panel installed vertically Trimmer placed in trusses each side of wall to allow fixing of wall clips Wall clips at all H-Stud, both sides of wall Truss bottom chord Wall clips at all H-Stud, both sides of wall Wall framing 200mm min. FIG 35: ROOF VOID DETAIL WITH HORIZONTAL SHEETING (SIDE ELEVATION) Wall clips at 600mm max. centres, both sides of wall Gyprock Shaft Liner Panel panel installed horizontally Back to back H-Studs installed horizontally Trimmer placed in trusses each side of wall to allow fixing of wall clips 600mm max. Rockwool cavity seal between battens 16mm Gyprock Fyrchek laminated to Gyprock Shaft Liner Panel with laminating screws at 400mm x 400mm max. centres 100mm max. Wall clips at all H-Stud, both sides of wall Gyprock Shaft Liner Panel installed vertically GYPROCK PARTY WALL SYSTEMS 27

Health & Safety Information on any known health risks of our products and how to handle them safely is on their package and/or the documentation accompanying them. Additional information is listed in the Material Safety Data Sheet. To obtain a copy, telephone 1800 807 668. Warranty Gyprock products are manufactured for life, with all CSR products designed to achieve optimal performance when part of a CSR integrated system. Gyprock continues to lead the market with premium quality products which are the preferred choice of plastering professionals. Gyprock plasterboard products are manufactured to the Australian Standard AS2588, providing confi dence in quality of product and support. For details on our product warranty, please visit www.gyprock.com.au, or contact us on 1300 306 556. Contact Details CSR Gyprock Website www.gyprock.com.au CSR Gyprock Sales Support Telephone: 13 17 44 Facsimile: 1800 646 364 CSR DesignLINK Technical Support Service Telephone: 1800 621 117 Facsimile: 1800 069 904 Email: designlink@csr.com.au New South Wales and ACT 376 Victoria Street, Wetherill Park NSW 2164 Queensland 768 Boundary Road, Coopers Plains QLD 4108 Victoria 277 Whitehall Street, Yarraville VIC 3013 South Australia Lot 100 Sharp Court, Mawson Lakes SA 5095 MANUFACTURED FOR LIFE Western Australia 19 Sheffi eld Road, Welshpool WA 6106 Tasmania 11 Farley St, Derwent Park TAS 7009 Northern Territory Cnr Stuart Hwy & Angliss St, Berrimah NT 0828 GYP513 July 2014 CSR Gyprock, CSR Building Products A.B.N. 55 008 631 356. CSR Limited 2013. Except as provided by the Copyright Act 1968, no part of this publication maybe reproduced in any form or by any means without the prior written permission of CSR Limited. The following are trade marks of CSR Limited and are under license. CSR, Gyprock, Soundchek, Aquachek, Superchek, Fyrchek, CeminSeal, Bradford, DesignLINK. GYP513.BMS1048.0714