Elemental analyzer multi EA 5000



Similar documents
ORGANIC SAMPLE PREPARATION

The art of elemental analysis

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Phoenix Apollo Laboratory TOC Analyzers and Services Designed To Meet Your Needs

TRL-onlineTOC Monitor is designed for monitoring carbon content in

AMD Analysis & Technology AG

Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber

Assignment 8: Comparison of gasification, pyrolysis and combustion

MILESTONE H E L P I N G C H E M I S T S

Thermo Scientific ConFlo IV Universal Interface

DMA-1 Direct Mercury Analyzer

GC-xt. The most flexible GC /GC-MS liquid sample injector

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

IB Chemistry. DP Chemistry Review

Fundamentals of Mass Flow Control

atm = 760 torr = 760 mm Hg = kpa = psi. = atm. = atm. = 107 kpa 760 torr 1 atm 760 mm Hg = 790.

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Designed for multi-injector endurance testing, the

Lovis 2000 M/ME. Microviscometer. ::: Viscometry at its best

QuickCODultra. Online COD for every kind of water. Especially for the rough stuff. Fast. Precise. Reliable. COD-ANALYSis

DSC Differential Scanning Calorimeter

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Chapter 1 The Atomic Nature of Matter

limit to percentage levels, a limited working range translates

XFA 600 Thermal Diffusivity Thermal Conductivity

FP628. Nitrogen / Protein Determination by Combustion. Rev 1-6/8/11

DETERMINATION OF TOTAL CARBON, TOTAL ORGANIC CARBON AND INORGANIC CARBON IN SEDIMENTS

Balancing chemical reaction equations (stoichiometry)

Get the Right GC for Your Industry

Fields of Application / Industry:

The Sievers 900 Series TOC Analyzers

Facts About. Industrial gases for better injection molding. This article appeared in the trade journal Kunststoffe plast europe, issue 12/2004.

Focus XC. Ultimate Fully Automated Peptide Synthesizer with Sonication and Heating Options

Lecture 35: Atmosphere in Furnaces

Module 5: Combustion Technology. Lecture 34: Calculation of calorific value of fuels

This chapter is devided into two sections:

Modern approaches to determination of toxic metals in marine environmental objects. Atomic absorption and inductively coupled plasma, advantages and

Valve Sizing. Te chnic al Bulletin. Flow Calculation Principles. Scope. Sizing Valves. Safe Product Selection.

Heterogeneous Homogenous. Mixtures; Solutions. Phases of matter: Solid. Phases of Matter: Liquid. Phases of Matter: Gas. Solid, Liquid, Gas

Karl-Fischer Titration the method for determining water

Continuous flow direct water heating for potable hot water

AC Service Equipment ACE 21 EXPERT. Fully automatic service station. R-1234yf refrigerant. Made in Germany

Water for Injection (WFI) and Pure Steam Production in a Lean Manufacturing Environment. Larry Zanko Project Manager STERIS Corporation

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

YSI 2900 Series Biochemistry Analyzers FERMENTATION CONTROL FOOD & BEVERAGE CLINICAL RESEARCH

BEP FD-2 CONTOUR MATRIX FUME DETECTOR

Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants

INDEX GENERAL

Diagram of components 2. Reducer..3

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES

BB-18 Black Body High Vacuum System Technical Description

FINESORB Surface Area. as or more than m 2 /g. Distribution of Pore nm. Degas & Analysis Up to 12 Degas & 6 Analysis Station

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Nitrogen analysis is elementary

Module 5: Combustion Technology. Lecture 33: Combustion air calculation

Doing a thorough job.

Transformer Oil Gas Analysis

FURNACEPHOSPHORUS AND PHOSPHORICACID PROCESS ECONOMICS PROGRAM. Report No. 52. July A private report by. the

Online Infrared Flue Gas Analyzer Gasboard 3000

Product overview Air conditioning service units

QGA Quantitative Gas Analyser

ETC -SV. Class 0 oil-free compressed air through catalysis

Chapter 8: Chemical Equations and Reactions

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

= atm. 760 mm Hg. = atm. d. 767 torr = 767 mm Hg. = 1.01 atm

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Gas water heaters. Why Vaillant? Because warm water is our business for more than 135 years.

CHEM 105 HOUR EXAM III 28-OCT-99. = -163 kj/mole determine H f 0 for Ni(CO) 4 (g) = -260 kj/mole determine H f 0 for Cr(CO) 6 (g)

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

World s Best Oil in Water Analyzers

Dewchecker 2.0. Operating instructions. messen steuern automatisieren - messen steuern automatisieren - messen steuern - automatisieren

Hydraulic control unit series

CHAPTER 3: MATTER. Active Learning Questions: 1-6, 9, 13-14; End-of-Chapter Questions: 1-18, 20, 24-32, 38-42, 44, 49-52, 55-56, 61-64

Environmental Analysis Using the ICS-3000 Ion Chromatography System

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

AMMONIA AND UREA PRODUCTION

CHROMOCTANE O N LINE ANALYZER

NANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT

600-GD & 600-GDL 600 SERIES GAS DETECTOR

Application Requirement

Evaluating Thermal & Catalytic Oxidation Technology for VOC, HAP & Odor Abatement. John Strey

Micro GC Fusion Pre-Installation Checklist

Introduction to Bomb Calorimetry

DOWEX Resins as Organic Solvent Desiccants

ngenieros Ingenieros Asociados De Control S.L.

SDT 2960 Simultaneous DSC-TGA including DTA capabilities

1.3 Properties of Coal

Alarm and Detection/Suppression

Mitos P-Pump. product datasheet

dryon Processing Technology Drying / cooling in outstanding quality we process the future

To measure the solubility of a salt in water over a range of temperatures and to construct a graph representing the salt solubility.

Thermal Flow Sensor Die

23 The Thermal Conductivity Detector

The laboratory fulfils the requirements for periodic emission measurement according to ČSN P CEN/TS 15675:2009

HCE80/HCC80/HCE80R/HCC80R

TECHNICAL BRIEF Critical Point Drying

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

Transcription:

Elemental analyzer multi EA 5000 Analytik Jena AG Konrad-Zuse-Str. 1 07745 Jena/Germany www.analytik-jena.com info@analytik-jena.com 1/6

multi EA 5000 The multi EA 5000 is a powerful elemental analyzer with a convincing overall concept for the determination of Total Carbon, Total Nitrogen, Total Sulfur and Total Chlorine. Liquid, solid, gaseous and LPG samples can be analyzed directly and without any laborious pretreatment. The multi EA 5000 offers for each kind of sample matrix an optimized sample introduction system. Unique Features Real multi-matrix analyzer for liquids, solids, gases, LPG samples Real multi-element analyzer for the determination of Carbon, Nitrogen, Sulfur and Chlorine in one analysis cycle Simultaneous Carbon, Nitrogen and Sulfur determination, sequential determination of Chlorine Automatic switch-over between Carbon, Nitrogen, Sulfur and Chlorine determination without hardware changes Unique sensitivity for Carbon, Nitrogen, Sulfur and Chlorine in ultra trace analysis Outstanding wide operation range from lowest ppb wt-% Revolutionary FAST connection technique guarantees simple operation free of gas leaks Self Check System (temperature, gas flow, pressure and tightness control) for troublefree operation and highest ease of use combined with low maintenance effort Flow Management System enables stable gas flows and system tightness check for operating safety and reliable analysis results The optional double furnace technology enables vertical and horizontal operation with only one system. That allows a perfect adjustment of the combustion process to the requirements of every sample matrix Flame sensor technology for trouble free matrix-optimized combustion in horizontal mode Intuitive user guidance by multi Win software avoids operator mistakes Only one multi-matrix sampler for vertical and horizontal mode necessary. It enables automatic introduction of liquids, solids, EOX samples, AOX samples and TOC samples, as heated version for injection of viscose liquids available Analytik Jena AG Konrad-Zuse-Str. 1 07745 Jena/Germany www.analytik-jena.com info@analytik-jena.com 2/6

Efficient Combustion of Samples High-temperature oxidation High combustion temperatures of up to 1100 C ensure complete oxidation of samples and reliable analysis results. Catalyst free combustion, because of the high temperature no additional expensive catalyst is necessary for the quantitative decomposition of the samples. Required gases; Argon (min. quality 4.6) and Oxygen (min. quality 4.5) The multi EA 5000 combines vertical and horizontal operation mode in one and the same device. The use of only one multi-purpose combustion tube for all standard applications, whether horizontal or vertical, makes conversion child s play. It is not necessary to change tubes. Combustion in horizontal mode The optional flame sensor technology guarantees a complete and trouble-free combustion. The combustion process is adjusted automatically by means of the flame sensor to the requirements of each individual sample. Combustion in vertical mode The special construction of the multi-purpose combustion tube guarantees a complete and trouble-free combustion of liquid, gaseous and LPG-samples. Only one combustion tube is used for all sample matrices, no hardware change necessary. Analytik Jena AG Konrad-Zuse-Str. 1 07745 Jena/Germany www.analytik-jena.com info@analytik-jena.com 3/6

Sample Introduction Systems Automation of the multi EA 5000 gives you a higher sample throughput for solids and liquids than has ever been reached before, both in vertical and horizontal operation. Special modules for gas and LPG analysis have been optimized for the tasks in question. Our sampling systems combine extremely high ease of use and ultra-modern technologies with maximum safety for the user. MMS 5000 The Real Multi-Matrix Sampler The MMS 5000 can be operated in vertical as well as horizontal mode. The same sampling system can be used also for liquids and solids, EOX, AOX, and TOC samples. The sample volume and injection speed (liquids) can be selected and adjusted by the user. For liquid sampling additional rinsing steps with sample or a pure solvent can be performed automatically by the sampler. Autoinjector Automatic Injection Without Autosampler The autoinjector is suitable for the injection of liquids in vertical as well as horizontal operation mode. Standardized filling volumes by means of one-step filling eliminate subjective faults being made by different operators. GSS Module The GSS module is optimized for the introduction of samples in the gaseous state. The sample volume and introduction speed can be adjusted for each gas type separately by the user. LPG Module Unique Precision Even at Low Sample Pressure The LPG module is optimized for the automatic and precise introduction of liquefied pressurized gases (LPG). No additional sample pressurization is required. A special Peltier cooling for the sampling valve avoids uncontrolled evaporation and bubble formation. A heated evaporation chamber guarantees a complete transfer of even low volatile components into the gaseous state. GSS/LPG Combi Module Intelligent Combination for Pressurized Gases: The GSS/LPG combi module is a perfect solution for multiple gas analysis. It incorporates all advantages of the LPG module. Memory-effects and cross-contamination are eliminated due to the use of two independent analysis branches. Analytik Jena AG Konrad-Zuse-Str. 1 07745 Jena/Germany www.analytik-jena.com info@analytik-jena.com 4/6

Determination of Nitrogen Determination of Sulfur Detection Principle Measuring Range (liquids) Chemoluminescence (CLD) 10.000 mg/l 30 µg/l UV-Fluorescence (UVFD) Coulometric titration (Coul.) 10.000 mg/l 40.000 mg/l 5 µg/l 0,6 mg/l Operation Range (mass) Sample Quantities Measuring Time** 16 µg N absolute 0,6 ng N absolute max. 500 µl (water) vertical: 4 min horizontal: 9 min 16 µg S absolute 200 µg S absolute 0,2 ng S absolute 0,2 µg S absolute vertical: 4 min horizontal: 9 min Furnace Temperature max. 1100 o C max. 1100 o C Gas Supply Power Supply Argon 4.6, Oxygen 4.5 (both, free of halogens & hydrocarbons) 100 240 VAC, 50/60 Hz, max. 16 A Basic device (vertical): 513 mm x 464 mm x 551 mm Dimensions (W x H x D) (without PC and monitor) Basic device incl. automatic boat drive (horizontal): 1073 mm x 464 mm x 551 mm Accessory module without basic device: 296 mmx464 mmx492 mm Analytik Jena AG Konrad-Zuse-Str. 1 07745 Jena/Germany www.analytik-jena.com info@analytik-jena.com 5/6

Determination of Carbon Determination of Chlorine Detection Infrared spectrometry (NDIR) Coulometric titration Measuring Range (liquids) Operation Range (mass) 100 wt-% (organics) 10.000 mg/l (water) 100 µg/l (organics) 200 µg/l (water) 50.000 µg C absolute 100.000 mg/l 100 µg/l 1000 µg Cl absolute Sample Quantities Measuring Time* 0.3 µg absolute max. 500 µl (water) vertical: 4 min horizontal: 9 min 10 ng Cl absolute vertical: 8 min horizontal: 10 min Furnace Temperature max. 1100 o C max. 1100 o C Gas Supply Power Supply Argon 4.6, Oxygen 4.5 (both, free of halogens & hydrocarbons) 100 240 VAC, 50/60 Hz, max. 16 A Basic device (vertical): 513 mm x 464 mm x 551 mm Dimensions (W x H x D) (without PC and monitor) Basic device incl. automatic boat drive (horizontal): 1073 mm x 464 mm x 551 mm Accessory module without basic device: 296 mmx464 mmx492 mm * depending on configuration, method settings and operation mode of analytical system ** depending on the selected injection volume, the purity of the vessels, chemicals and gases used, and the qualification of the operator and the used method *** depending on density, homogeneity and shape of sample material Analytik Jena AG Konrad-Zuse-Str. 1 07745 Jena/Germany www.analytik-jena.com info@analytik-jena.com 6/6