Serial ATA RAID PCI Card



Similar documents
Encore SATA2 RAID PCIe Card

6-Port SATA II 150 PCI Host Card w/raid

PCI ATA 133 RAID Controller Card. User Manual

Serial ATA RAID PCI. User's Manual

SATA1.5G/ATA133 RAID Controller Card RC215 User Manual

User manual Ver: 2.0. SATA Channel PCI RAID Card

The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled systems.

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

Serial ATA 4-Channel RAID Quick Installation Guide

SATA II PCIe RAID Quick Installation Guide

PCI SATA + PATA Raid Card

SATA II PCIe RAID Quick Installation Guide

SATA 150 RAID. user. Model MAN UM

4+1 SATA II 300 IDE/PATA PCI-E. Combo Host Card w/ RAID & Port. Multiplier

SATA II-150 PCI RAID

SATA II 4 Port PCI RAID Card RC217 User Manual

RAID installation guide for Silicon Image SiI3114

The UltraATA 133 PCI is an ultra high-speed dual channel Ultra ATA/133 controller board for use in Pentium-class computer.

Low Profile Ultra ATA-133 RAID PCI Host

esata 3.0Gbps RAID ExpressCard

Serial ATA PCI Quick Installation Guide

HP dx5150 RAID Installation and Setup Guide Version Document Part Number:

SATA II-150 PCI Quick Installation Guide

SATARaid Serial ATA RAID Management Software

Ultra ATA 133 RAID PCI Pro

SATA 6G PCIe Card User Manual Model: UGT-ST622

Addonics. 4-Port External SATA II PCI/PCI-X RAID5 Controller Card (ADS3GX4R5-E) User s Guide Revision 1.1 T E C H N O L O G I E S

Serial ATA 2 Ports PCI Host

SATA RAID Function (Only for chipset Sil3132 used) User s Manual

46xx_47xx_1546_1547 RAID Recovery/Set Up Instructions

Guide to SATA Hard Disks Installation and RAID Configuration

Chapter 2 Installation

SATARAID5 Serial ATA RAID5 Management Software

RAID Option Installation

SATA RAID SIL 3112 CONTROLLER USER S MANUAL

4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card

UltraATA 100 PCI RAID TM

PCI SATA RAID Card User Manual

SERIAL ATA HOST CONTROLLER CARD USER MANUAL SATA R SATA I WARNING

SATA RAID Function. (Only For Chipset Sil 3112 /Sil 3512 Used) USER S MANUAL 12M E-SI

RAID installation guide for ITE8212F

Installation Guide. RAID 5 esata 3Gbps 2 external port Low profi le PCI Express card. GICe702S3R5W6 PART NO. M0557

Table of Contents. Configuring IDE RAID Hard Drive(s) (Controller GigaRAID (IT8212))... 2

NVIDIA RAID Installation Guide

SATARAID5 Serial ATA RAID5 Management Software. Users Manual

Serial/ Parallel Combo PCi Card user manual

4 Port PCI SATA RAID Controller Adapter Card

M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual

VIA / JMicron RAID Installation Guide

PCIe SATA 6G Raid Card

2-Serial/1-Parallel Port PCI Adapter

IDE2410 ATA-100 IDE RAID Card. Version 1.0

RAID User Guide. Edition. Trademarks V1.0 P/N: C51GME0-00

ATA-133 IDE RAID Card. Version 1.1

Table of Contents 1. INTRODUCTION TO THE DC-200 RAID CARD... 3

SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: U49-M2-0E

SiI3132 SATARAID5 Quick Installation Guide (Windows version)

VT8237 SATA RAID User Manual

Promise FastTrak 100-Lite RAID Controller

RAID Manual. Edition. Trademarks V1.0 P/N: CK8-A5-0E

AMD RAID Installation Guide

SiS S-ATA User s Manual. Quick User s Guide. Version 0.1

Serial-ATA IDE Card. Version 1.0

AMD RAID Installation Guide

Intel ESB2 SATA RAID Setup Guidelines

PCI SATA Controller Card Model: SY-PCI40010

VIA RAID Installation Guide

SATA150 TX2PLUS, TX4 QUICK START GUIDE. Version 1.2

USB External Hard Disk Drive

SiS 180 S-ATA User s Manual. Quick User s Guide. Version 0.1

AMD RAID Installation Guide

Guide to SATA Hard Disks Installation and RAID Configuration

ITE RAID Controller USER MANUAL

English. Configuring SATA Hard Drive(s)

Installation Instructions for 9555 USB Driver

EX Port SATA3 RAID/HyperDuo PCIe(x2) Card

VIA RAID configurations

How To Set Up A Raid On A Hard Disk Drive On A Sasa S964 (Sasa) (Sasa) (Ios) (Tos) And Sas964 S9 64 (Sata) (

SiS964/SiS180 SATA w/ RAID User s Manual. Quick User s Guide. Version 0.3

Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively.

SCSI Card 2930CU. Installation Guide

How To Set Up Your Motherboard With A Power Supply And Power Supply On A Microtower 2.2 (Ios) With A Hard Disk Drive On A Mini Usb 2.3 (I386) With An External Hard Disk (I2)

High Density RocketRAID Rocket EJ220 Device Board Data RAID Installation Guide

2-Serial/1-Parallel Port PCI Adapter RC303 User Manual

INTRODUCTION INSTALLING THE SCSI CARD 2940UW PRO

DESKTOP. Internal Drive Installation Guide

2.5" XTreme Files OS & Data Backup/Restore User Manual Please read the Instruction manual before using the XTreme Files (X Series) 1.

USB Port PCI Express Card

SATA PCI Express Adapter PEXSATA22I

Data Lifeguard Tools. Software Manual

2-Port RS232 Serial PCI with UART Quick Installation Guide

Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines

SATA/eSATA II PCI & PCI-E Card & CardBus

ESATA PCI CARD. User s Manual

RocketRAID User's Manual. Revision: 1.0 Date: Mar HighPoint Technologies, Inc.

RAID configuration and driver installation guide

Intel Rapid Storage Technology

XTreme Files OS & Data Backup/Restore User Manual Please read the Instruction manual before using the XTreme Files (F Series) 1.

FASTTRAK USER MANUAL TX2200, TX2300. Version 3.2

Intel Matrix Storage Manager 8.x

Transcription:

Serial ATA RAID PCI Card User Manual 1

Features Silicon Image SiI3512 SATA controller chip Compliant with PCI Specification, Rev. 2.3 Compliant with Serial ATA 1.0 specification Provides two independent channels to support up to two Serial ATA drives Supports RAID0(striping) and RAID1(mirroring) for speed and data protection respectively HDDs function normally when not in RAID sets Supports SATA up to 150MB/Sec Supports Windows 7 / Vista 32 /64-Bit/ 2003 32/64-Bit / XP /2000 Connectors 2 x internal SATA connectors System Requirements Pentium-class computer with one available PCI slot Windows 7 / Vista 32 /64-Bit/ 2003 32 /64-Bit / XP /2000 2

Hardware Installation 1. Turn Off the power to your computer and any other connected peripheral devices. 2. Unplug the power cord form the back of the computer. 3. Remove your computer s cover. 4. Remove the slot bracket from an available PCI slot. 5. To install the card, carefully align the card s bus connector with the selected PCI slot on the motherboard. Push the board down firmly, but gently, until it is well seated. 6. Replace the slot bracket s holding screw to secure the card. Device Connection The SATA 150 PCI RAID Card is a two channel Serial ATA controller that supports up to two Serial ATA hard disk drives. It is recommended to use identical hard drives for all RAID configurations. 1. Install your hard disk drive(s) in chassis. 2. Connect the Serial ATA hard disk drive to the system power supply using the included Serial ATA power cable. 3. Connect one end of the Serial ATA cable to the hard disk drive. 3

4. Attach the other end of the Serial ATA cable to the Serial ATA port on the SATA 150 PCI RAID Card. 5. Follow the same instructions to connect up to two hard drives. Device connection is now complete. 6. Replace the computer cover and reconnect the power cord. RAID Arrays RAID Arrays are setup in the SATA 150 PCI RAID Card s BIOS. RAID 0 (Striping) This RAID array to be used on New/Blank hard drives. Striping will destroy existing data on the hard drive. Auto Configuration is recommended. For applications that require custom chunk size, Manual Configuration is offered. Auto configuration (recommended) The default chunk size is 64k when selecting Auto configuration. 1. As the BIOS boots press Ctrl+S or F4 when prompted to enter 4

the RAID BIOS. 2. At the next screen select Create RAID Set, then press Enter. 3. Select Striped, then press Enter. 4. Select Auto configuration, then press Enter. 5. When asked Are You Sure (Y/N)?, press Y to accept. 6. Press Ctrl+E to exit the BIOS. 7. When asked Are you sure to exit (Y/N)?, press Y to exit and reboot. 8. Continue with FDISK and FORMAT steps as if you were installing a conventional hard drive. Manual configuration 1. As the BIOS boots press Ctrl+S or F4 when prompted to enter the RAID BIOS. 2. At the next screen select Create RAID Set, then press Enter. 3. Select Striped, then press Enter. 4. Select Manual configuration then press Enter 5. Select the first drive, press Enter. 6. Select the second drive, press Enter. 7. Select chunk size from 4k, 8k, 16k, 32k, 64k or 128k, then press 5

Enter. 8. When asked Are You Sure(Y/N)?, press Y to accept. 9. Press Ctrl+E to exit the BIOS. 10. When asked Are you sure to exit(y/n)?, press Y to exit and reboot. 11. Continue with FDISK and FORMAT steps as if you were installing a conventional hard drive. RAID 1 (Mirror) For New/Blank Hard Drives 1. As the BIOS boots press Ctrl+S or F4 when prompted to enter the RAID BIOS. 2. At the next screen select Create RAID Set, then press Enter. 3. At the next screen select Mirrored then press Enter. 4. Select Auto configuration, then press Enter. 5. When asked Are You Sure(Y/N)?, press Y to accept. 6. Press Ctrl+E to exit the BIOS. 7. When asked Are you sure to exit(y/n)?, press Y to exit and reboot. 8. Continue with FDISK and FORMAT steps as if you were 6

installing a conventional hard drive. For Existing Hard Drives with Data 1. As the BIOS boots press Ctrl+S or F4 when prompted to enter the RAID BIOS. 2. At the next screen select Create RAID Set, then press Enter. 3. At the next screen select Mirrored then press Enter. 4. Select Manual configuration, then press Enter. 5. Select the Source drive, press Enter. 6. Select the Target drive, press Enter. 7. Enable Disk Copy, select Yes, then press Enter. Note: Enable Disk Copy Copy current content of source driver to mirror drive; Disable Disk Copy RAID 1 set formed must be repartitioned and reformatted to guarantee the consistency in their contents. 8. Press Ctrl+E to exit the BIOS. 9. When asked Are you sure to exit(y/n)?, press Y to exit and reboot. Note: If during boot the RAID BIOS reports an RAID1 set is in Rebuild status, The rebuild will continue after boot sequence is 7

complete, disregard the message, continue booting, and let the Mirror rebuild. Rebuilding a Failed Mirror Set When a failure to one member occurs, you will be notified either by the RAID BIOS during boot or by the SATARAID GUI while in Windows. The steps below will guide you in rebuilding a failed mirror set. 1. Replace the failed drive with one of equal or greater capacity, then start the computer. 2. During boot press Ctrl+S or F4 to enter the RAID BIOS. 3. Select Rebuild Mirrored Set then press Enter. 4. Select the desired set and then press Enter. 5. When asked Are You Sure(Y/N)?, press Y to confirm. 6. The set will be rebuilt. Deleting RAID Arrays 1. As the BIOS boots press Ctrl+S or F4 when prompted to enter the RAID BIOS. 2. Select Delete RAID Set, then press Enter. 8

3. Select the RAID set then press Enter. 4. When asked Are You Sure(Y/N)?, press Y to confirm. Resolving Conflicts When a RAID set is created, then metadata written to the disk includes drive connection information. If, after a disk failure, the replacement disk was previously part of a RAID set (or used in another system), it may have conflicting metadata. If so, this will prohibit the RAID set from being either created or rebuilt, in order for the RAID set to function properly, this old metadata must be first overwritten with the new metadata. To resolve this, from the main BIOS window select Resolve Conflicts, then press Enter, the correct metadata, including the correct drive connection information, will be written to the replacement disk. Low Level Format Low Level Format is build into the RAID BIOS to make it more convenient to erase the entire contents of a hard disk drive, including data, drive and partition information. The Low Level Format utility works on single hard drive only, before the RAID set is configured. 9

BIOS Configuration The Serial ATA 2-Channel RAID adapter BIOS will appear every time your system starts up. If the BIOS doesn t show, please try your controller in another PCI slot. During this (POST) process, the BIOS will show up and indicate the devices attached to it. Driver Installation For Windows 2000 For A New Installation A new installation requires a floppy disk for the driver installation. To make this floppy disk, copy the contents of the DS-33101\2K_XP_2003_Vista folder, found on the driver CD, onto a blank floppy disk then follow the directions below. 1. Setup the RAID Array prior to Windows installation. 2. Follow Windows 2000 installation procedure. 3. Restart the computer when prompted by the installation. 4. At the Windows 2000 Setup screen, press F6 to install the RAID driver. 10

5. When prompted, press S to specify the location of the driver. 6. Insert the floppy disk, then press Enter. 7. Select Silicon Image SiI 3x12 SATARAID Controller for Windows NT 4.0 and 2000, then press Enter. 8. Press Enter again to finish driver installation, then follow the on-screen instructions to complete the Windows installation. For An Existing Installation 1. Setup the RAID Array prior to driver installation and boot up to Windows. 2. At Found New Hardware Wizard, click Next. 3. Select Search for a suitable driver for my device(recommend) then click Next. 4. Insert the driver CD, check CD-ROM drives, uncheck the other boxes, click Next, then click Next again. 5. If the Digital Signature Not Found message appears, click Yes. Our driver has been thoroughly tested for stability and compatibility. 6. Click Finish. 11

For Windows XP/Server 2003 For New Installation A new installation requires a floppy disk for the driver installation. To make this floppy disk, copy the contents of the DS-33101\2K_XP_2003_Vista folder, found on the driver CD, onto a blank floppy disk then follow the directions below. 1. Setup the RAID Array prior to Windows installation. 2. Follow Microsoft s Windows installation procedure. 3. Restart the computer when prompted by Windows installation. 4. At the Windows Setup screen, press F6 to install the RAID driver. 5. When prompted, press S to specify the location of the driver. 6. Insert the floppy disk, then press Enter. 7. Select Silicon Image SiI 3x12 SATARaid Controller for Windows XP/Server 2003, then press Enter. 8. Press Enter to finish driver installation, then follow the on-screen instructions to complete the Windows installation. Note: If the Security Alert warning pops up, click Yes. Our driver has passed Microsoft compatibility testing, this message appears during new installation. 12

For An Existing Installation 1. Setup the RAID Array prior to driver installation and boot up to Windows. 2. At the Found New Hardware Wizard: XP(w/SP1 or earlier)/server 2003: continue to step #3 XP(w/SP2 or later)/server 2003(w/SP1 or later): select No, not this time, then click Next. 3. Insert the driver CD, select Install the software automatically (Recommended), and click Next. 4. Click Finish. For Windows XP-x64/Server 2003-x64 For New Installation A new installation requires a floppy disk for the driver installation. To make this floppy disk, copy the contents of the DS-33101\XP_2003_Vista x64 folder, found on the driver CD, onto a blank floppy disk then follow the directions below. 1. Setup the RAID Array prior to Windows installation. 2. Follow Microsoft s Windows installation procedure. 13

3. Restart the computer when prompted by Windows installation. 4. At the Windows Setup screen, press F6 to install the RAID driver. 5. When prompted, press S to specify the location of the driver. 6. Inset the floppy disk, then press Enter. 7. Select Silicon Image SiI 3x12 SATARaid Controller (64-bit Extended) or Silicon Image SiI 3x12 SATARaid Controller (Itanium), then press Enter. 8. Press Enter to finish driver installation, then follow the on-screen instructions to complete the Windows installation. Note: If the Security Alert warning pops up, click Yes. Our driver has passed Microsoft compatibility testing, this message appears during new installation. For An Existing Installation 1. Setup the RAID Array prior to driver installation and boot up to Windows. 2. At the Found New Hardware Wizard, select No, not this time, then click Next. 3. Insert the driver CD, select Install the software automatically (Recommended), and click Next. 14

4. Click Finish. 15

For Windows Vista For New Installation A new installation requires a floppy disk for the driver installation. To make this floppy disk, copy the contents of the DS-33101\2K_XP_2003_Vista folder, found on the driver CD, onto a blank floppy disk then follow the directions below. 1. Setup the RAID Array prior to Windows installation. 2. Follow Microsoft s Windows installation procedure. 3. Restart the computer when prompted by Windows installation. 4. At the Windows Setup screen, press Load Driver to install the RAID driver. 5. Insert the floppy disk, please select Silicon Image SiI 3512 SATARaid Controller (A:\si3112r.inf), then press Next. (Change A:\ to match your floppy drive letter) 6. Follow the on-screen instructions to complete the Windows installation. For An Existing Installation 1. Setup the RAID Array prior to driver installation and boot up to Windows. 2. At Found New Hardware Wizard, select Locate and install driver software (recommended). 16 3. Please insert the CD driver bound with SATA 150 PCI RAID card into your CD-ROM Drive, click Next. 4. If the system prompts the user informing the drivers are not signed, select the option Install this driver software anyway. 5. Click Close to complete the installation.

For Windows Vista-x64 For New Installation A new installation requires a floppy disk for the driver installation. To make this floppy disk, copy the contents of the DS-33101\XP_2003_Vista x64 folder, found on the driver CD, onto a blank floppy disk then follow the directions below. 1. Setup the RAID Array prior to Windows installation. 2. Follow Microsoft s Windows installation procedure. 3. Restart the computer when prompted by Windows installation. 4. At the Windows Setup screen, press Load Driver to install the RAID driver. 5. Insert the floppy disk, please select Silicon Image SiI 3512 SATARaid Controller (A:\si3112r.inf), then press Next. (Change A:\ to match your floppy drive letter) 6. Follow the on-screen instructions to complete the Windows installation. For An Existing Installation 1. Setup the RAID Array prior to driver installation and boot up to 17

Windows. 2. At Found New Hardware Wizard, select Locate and install driver software (recommended). 3. Please insert the CD driver bound with SATA 150 PCI RAID card into your CD-ROM Drive, click Next. 4. If the system prompts the user informing the drivers are not signed, select the option Install this driver software anyway. 5. Click Close to complete the installation. To Verify Windows Installation 1. Right click My Computer and click Manage. 2. Select Device Manager. 3. Double click Storage controllers (Storage controllers Vista), then double click Silicon Image SiI 3512 SATARaid Controller to display driver properties. A message this device is working properly is displayed in the dialog box, the driver has been correctly installed. JAVA 2 Runtime Environment Installation The Java 2 Runtime Environment is required for the SATARAID 18

Management Software. 1. Please insert the CD driver bound with SATA 150 PCI RAID card into your CD-ROM Drive. 2. At the Windows desktop click Start, then Run. 3. Type D:\DS-33101\InstallSATARaid.exe, then click OK. (Change D: to match your CD-ROM drive letter) 4. Follow the on-screen instructions to complete the installation. SATARAID Management Software Installation 1. Please insert the CD driver bound with SATA 150 PCI RAID card into your CD-ROM Drive. 2. At the Windows desktop click Start, then Run. 3. Type D:\DS-33101\jre-1_5_0_05-windows-i586-p.exe, then click OK. (Change D: to match your CD-ROM drive letter) 4. Follow the on-screen instructions to complete the installation. 19