Structured Cabling, Earthing & Equipotential Bonding



Similar documents
Separation of power and information technology cabling

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

EMC Engineering Guidelines For Automation Systems PS 4 PS /97 AWB GB

Networks. The two main network types are: Peer networks

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

Ethernet Patch Cord Wiring

Network Design. Yiannos Mylonas

Specifying an IT Cabling System

Accelerating Light. Copper Cabling Solutions. Category 6A

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Video Camera Installation Guide

with Component Rating A Simple Perspective

White Paper: DC Resistance Unbalance Testing: Easy, Low-Cost Insurance for Your PoE Systems

3x cinch/s-video socket Order no.: xx. USB/3.5 mm audio socket Order no.: xx. VGA socket Order no.: xx

Structured and Point to Point Network Cabling for Industrial Automation

Server Rack Commissioning

428 MY HOME Structured cabling system for the home sector

EN and EN : 2008 Integrated standards for telecommunications cabling installation

CONTINUOUS MONITORING AND AVOIDANCE OF RESIDUAL CURRENTS IN DATA CENTRES WITH RCM White paper Revision 2

ARE YOU WIRING FOR A SMART HOME? Guidelines for homeowners on the wiring requirements for telecommunications and other wired services.

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS

A guide to connecting to fibre optic networks for homeowners, architects, builders and developers.

IP PHONE SYSTEM. CooVox Series-U60 For Small and Medium Business. Quick Installation Guide.

LANscape Solutions. FutureCom Shielded Copper Cabling Systems 2008/09

The High Cost of a Low-Cost Cable Certification Tester

White Paper. Power over Ethernet Plus Update and Cabling Considerations

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

Cat7/Class F New Installation Concept New infrastructure. Handbook

Introduction to Data Centre Design

Panduit 28 AWG Patch Cords Installation Guideline

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Chapter 4 Connecting to the Internet through an ISP

STRANDED AND SOLID CONDUCTOR

Innovative Connectivity Solution for Maximum Performance and Security

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

Cabling Standards Update 2014

Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)

contents my HOmE - STrUCTUrEd CaBLing SYSTEm FOr THE HOmE SECTOr

Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

Subminiature Load Cell Model 8417

HP ProCurve High-Speed Transceivers Installation Guide

AXIS T81B22 DC 30W Midspan

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

HERZ-Thermal Actuators

Digital inductive conductivity transmitter

Chapter 9. Bonding and Grounding

What are the requirements for a Home Network?

HARTING mcon 1000 Introduction and features

Provides one channel for Ethernet over existing

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

This amendment A1 modifies the Technical Basis for Regulation TBR 12 (1993)

Operating instructions Supply system for flammable liquids. Labor

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

Session 14 Cable Support Systems

Installation Manual. BYD Wall-mounted AC Charging Box

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Cable Solutions for Servo and Variable Frequency Drives (VFD)

White Paper: Electrical Ground Rules

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

User Manual PT-E-HIP

Standard Buccaneer - Ethernet

Security & Surveillance Cabling Systems

The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges

PROFINET. Design Guideline

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

TC Grounding and Bonding for Telecommunications Systems

HARTING Ethernet Cabling 4-poles Overview

The Quality Connection. Industrial IT cabling ISO/IEC / EN

How to Choose the Right Cable Category

Comparative study for cables and busbars

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

Foreword. Page 2 EN :2000

This draft amendment A1, if approved, will modify the Technical Basis for Regulation TBR 14 (1994)

White paper. Shielded or unshielded network cables A matter of choice, electromagnetic environment and compatibility

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

PXL-250: Network Wiring

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities

Keystone Network Isolator with ESD- and Lightning Protection

How To Set Up A Minipatch System For A Small Office Or Home Use

Product and functional description

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

Cat. 6 A EL Incredibly fast Get more

IP DSLAM IDL Quick Installation Guide

Transcription:

White Paper Information and Communication Technology Structured Cabling, Earthing & Equipotential Bonding English Rev. 1.0.1 / 2012-06-01

1 Abstract All Dallmeier network products (PoE cameras, recorders, servers, etc.) are subject to the highest quality standards and the strictest testing requirements as well as a continuous improvement process in order to guarantee the best picture quality, highest functional reliability and longest durability of the individual product at all times. In addition, all Dallmeier products are compliant with the currently valid EMC directives for the avoidance of electromagnetic interferences (EMI). However, be aware that a proper operation of the system is only possible, if all of the applied network components, as for example routers/poe switches, cables, network cabinets and end-user devices, etc. are correctly installed in the overall system. Particularly, the regulations and norms for the installation and operation of electrical and information technology equipment/devices must be paid attention and adhered to at all costs in order to avoid accidents and/or damages to the devices and to attain maximum immunity to electromagnetic interferences. The following descriptions serve as guidelines for the correct approach in reference to the earthing and equipotential bonding of electrical and electronic devices in information technology networks and as support for the installation of an EMC-compliant and interferencefree IT infrastructure or rather a structured network cabling. 2 Target Audience The target audience of this document is trained and authorised specialists (installers) for information and communication technology security systems as well as specialised personnel (electricians), planners and operators of electrical installations. 3 Legal Issues The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express authorization is prohibited. Offenders will be held liable for the payment of damages. Dallmeier accepts no liability for damages to persons and property or pecuniary damages arising due to minor defects of the documentation, e.g. print or spelling errors, or caused by direct or indirect use of this material. The descriptions in this documentation exclusively serve informational purposes and are not legally binding. The installer/operator of electrical and information technology equipment/devices himself or herself is responsible for the compliance with the legal regulations of all standards and directives that must be applied, and must regularly monitor their adherence. 2 www.dallmeier.com

4 Standards and Directives In addition to the currently valid requirements concerning the electromagnetic compatibility (EMC) the following standards and directives for the safety and interference immunity of information and communication technology equipment including equipotential bonding and earthing are to be adhered to (amongst others): DIN VDE 0100-410 (VDE 0100-410:2007-06) Low-voltage electrical installations Part 4-41: Protection for safety Protection against electric shock DIN VDE 0100-540 (VDE 0100-540:2007-06) Low-voltage electrical installations Part 5-54: Selection and erection of electrical equipment Earthing arrangements, protective conductors and protective bonding conductors DIN EN 50310 (VDE 0800-2-310:2011-05) Application of equipotential bonding and earthing in buildings with information technology equipment The specification, installation and testing of generic (or application-neutral) and specific cablings, amongst others, must comply with the following standards and guidelines: Series DIN EN 50173 Information technology Generic cabling systems or ISO/IEC 11801 Information technology Generic cabling for customer premises Series DIN EN 50174 (VDE 0800-174) Information technology Cabling installation Updated copies of each of the mentioned VDE regulations are available at the VDE Verlag (publishing house) or, as for the DIN and ISO standards, at the Beuth Verlag (publishing house). www.dallmeier.com 3

5 Structured Cabling, Shielding, Connection Components The goal of a structured cabling is a future-oriented and generic network infrastructure. In general, the structured cabling of all network components is star-wired (star topology). The structured cabling is divided into three areas: Primary area (campus or rather building to building cabling via fibre optic cable) Secondary area (vertical cabling preferably via fibre optic cable) Tertiary area (horizontal cabling via copper cable) Elements of the structured cabling are: patch panels patch cables, horizontal cables network sockets connectors distribution/network cabinets hubs, switches, routers, Above all, the following passage describes the structured cabling in the tertiary area. In order to avoid signal interferences (undesired electrical or electromagnetic effects), an EMC-compliant cabling must be conducted (EMC = electromagnetic compatibility). Moreover, be aware to only apply technically efficient, EMC-compliant and shielded components. This includes shielded and symmetrical copper-based twisted-pairs cables (e.g. S/FTP cables) and shielded RJ45 modules according to ISO/IEC-11801 or DIN EN 50173 as well as the standard-compliant application of earthing and equipotential bonding measures in buildings with information technology equipment. Always ensure the cable shield to feature a full, if possible 360 degree contacting when connecting to a shielded connection component. In addition, in order to reach maximum immunity and the best signal transmission as possible, the same type of cable should be used within the overall system wherever possible. The housing of each connection unit or rather each information technology connection socket (RJ45), to which a network device is connected via a symmetric copper cabling, must be shielded (e.g. metal housings, plastic housings with a galvanic or chemo-galvanic metal coating) and equipped with shielded RJ45 (8p8c) modular jacks. The shielding of the network cables between the transmitter and the receiver must be applied on both sides and take a continuous course in order to achieve a sufficient shielding against high-frequency interference signals. These requirements also apply to the cabling at work stations and the cabling of devices that are not part of generic cabling but part of the transmission line between transmitter and receiver. 4 www.dallmeier.com

Each connection must exhibit a transmission behaviour, which is consistent with the performance requirements of the particular application classes for symmetric transmission lines according to DIN EN 50173 and ISO/IEC 11801. Transmission lines in the tertiary area should always be kept as short a possible. The maximum length of a transmission line within the tertiary area (in terms of twistedpair cables, 100 Ω, 4-pair, shielded) between the active network device (e.g. switch) located in the equipment room on each storey (floor distribution terminals) and the network end-user devices located at the work station must not extend 100 metres. The complete transmission line is called the Channel Link. The structured cabling may consist of up to 90 meters of horizontal cable (uninterrupted solid-copper twisted-pair cable) for the fixed cabling (Permanent Link) between the floor distributor (patch panel) and the work-area telecommunications outlet and 10 metres of patch cables for the loose cabling (2 5 metres on each end). This means, that a maximum of 5 metres of patch cable is permitted for the connection between the patch panel and the active network device (e.g. switch) within the equipment room as well as a maximum length of 5 metres from the wall network socket to the end-user device located at the work station. 100 m Channel Link = 90 m Permanent Link + 10 m (2 5 m) patch cable Note: Horizontal cables are relatively rigid network cables and are used for the cabling of patch panels with permanently installed connection sockets inside of a building. The conductors of a horizontal cable consist of a single wire, which is applied to a shielded connection socket or alternatively a shielded patch panel (back side) via the punch-down technique, e.g. LSA or IDC (Insulation Displacement Connection) termination. Patch cables are flexible network cables and are used for the cabling of shielded patch panels (front side) with active network components (e.g. switch) located within the floor distributor and for the cabling of network sockets with end-user devices located at the work station. The conductors of a patch cable are designed as a strand (multiple fine single wires), which is pressed onto the contacts of shielded RJ45 connectors using a special crimping tool. RJ45 connectors can not be crimped onto horizontal cables. Patch cables can not be applied to insulation-displacement connectors. The termination of horizontal cables and the crimping of patch cables should only be conducted by experts, to ensure a correct signal transmission and a full shielding. The laying of network cables requires compliance with the specifications concerning the maximum permissible bending radii and the minimum requirements with reference to the wire diameter at all times. Excessive crushing of the cables (e.g. due to cable ties) and severe traction on the cable ends must be avoided. The twisting of the single cable pairs should be maintained as far as possible. www.dallmeier.com 5

6 Earthing and Equipotential Bonding For the safety of persons and devices and the immunity of information and communication technology equipment to electromagnetic interferences (EMI), all protective measures, which are specified by the currently valid DIN, VDE and ISO standards and which provide for a standard-compliant earthing and a correct equipotential bonding, are mandatory and must be fulfilled by all means. From an EMC point of view, power supply must generally be arranged as a TN-S system (separate protective earth (PE) and neutral (N) conductors) to prevent stray currents from flowing over the shields of the data cables which would cause an electromagnetic field and thus interferences. In case of damages due to unprofessional earthing or improper equipotential bonding the installer/operator of the electrical and information technology equipment will be held liable. The earthing of electrical installations and devices primarily has the function of protecting individuals from dangerous contact voltages in case of an electrical defect. Note: The installation of a standard-compliant protection against lightning impulses and overvoltage or measures to protect individuals from dangerous contact voltages, etc. is not addressed in this document. Yet, compliance with all standards and regulations for the safety of individuals and devices, which can be ensured by applying the pertinent professional measures, is implied. From an EMC point of view, the earthing of all network devices within a building has the purpose of creating a selected and common reference potential and thereby establish an equipotential bonding. According to DIN VDE 0100 Part 200 the equipotential bonding is defined as follows: Provision of electric connections between conductive parts, intended to achieve equipotentiality. Consequently, the equipotential bonding ensures, that potential difference (voltage) can not be induced due to the length of the cable (up to 100 metres) in between the applied devices and therefore prevents compensating currents from flowing beyond the shielding of the network cable, which would cause signal interferences or even damage the device. DIN VDE 0100-410 indicates, that a main equipotential bonding (protective equipotential bonding via the main earth bar) must be conducted in every building. A professional equipotential bonding of all network devices in an information technology equipment within a building can only be accomplished by consistently earthing all installed network components (network cabinets, patch panels, connection sockets, switches, end-user devices, etc.). The course of the laid earthing/equipotential bonding conductors of all network devices/ components towards a common equipotential bonding bar (EBB), which is connected to a central earth reference point within the building, must be kept as short as possible. In the process, a standard-compliant earthing resistance and the minimum prescribed cross-sections for earthing conductors have to be maintained at all times. 6 www.dallmeier.com

Each EMC-compliant shielded patch panel is, for example, connected to the enclosing/ housing of the distribution or rather the network cabinet (usually a 19" rack) via an earthing conductor. Subsequently, the network cabinet is earthed with the central earth reference point in the building via an equipotential bonding bar. Network devices (e.g. switches located at the work station), which are not automatically earthed via the protective contact of the power cord, must be earthed directly, professionally and in compliance with the standards by connecting their external earthing connection (earthing screw or tag) to the building s equipotential bonding via a separate earthing conductor. In the process, the legal earthing requirements and regulations must be adhered to at all times. For safety reasons, it is by all means prohibited to connect the external earthing to the earthing of a power outlet. To connect the earthing to a water or heating pipe is forbidden. Equipotential Bonding for Campus Cabling (Primary Area) In order to avoid possibly occurring potential differences between various earth reference points (with regard to a campus or respectively a building to building cabling) an optical connection (via fibre optic cables) must be used for the network cabling between the buildings. Merely the slightest differences in the soil condition of two buildings would create different earth potentials which would lead to equalising currents and those in turn would lead to electromagnetic interferences within the cabling. 7 Conclusion In order to assure a secure, interference-free and EMC-compliant operation of electrical and information technology equipment/devices the following remarks must be considered: Only authorised experts (installers) and trained professionals (electricians) are permitted to conduct an installation and testing of electrical and information technology equipment/devices Strictly adhere to pertinent standards and regulations Arrange the IT infrastructure as a structured cabling Generally arrange earthing concept and power supply as a TN-S system Use only EMC-compliant components and devices Use only shielded components (cables, plugs, sockets, etc.) and devices Ensure earthing and equipotential bonding of all applied components and devices www.dallmeier.com 7

Specifications subject to change without notice. Errors and misprints excepted. 2012 Dallmeier electronic Dallmeier electronic GmbH & Co.KG Cranachweg 1 93051 Regensburg Germany Tel.: +49 (0) 941 87 00-0 Fax: +49 (0) 941 87 00-180 www.dallmeier.com