MaxSea TimeZero Alarms



Similar documents
GO7. Getting Started ENGLISH. simrad-yachting.com

MaxSea TimeZero PLOT and ECS v2.1

How to import 3D (*.PTZ) data from MaxSea v12 to MaxSea TimeZero

A. BACK UP YOUR CURRENT DATA. QuickBooks Business Accounting Software for Windows Account Conversion Instructions

Document Revision Date: August 14, Create a New Data Protection Policy in the Symantec.cloud Management Portal

To download the latest version of TurboTick Pro go to

Connecting to a Soundweb TM. London Network

Kodak Asset Management Software Client Module

macquarie.com.au/prime Charts Macquarie Prime and IT-Finance Advanced Quick Manual

Setting Up a New Project

OneSourceFax Customer Guide

BlackHawk for MAC Software User Guide

Chapter 7 Event Log. 7.1 Event Log Management

BSDI Advanced Fitness & Wellness Software

How To Send An Encrypted In Outlook 2000 (For A Password Protected ) On A Pc Or Macintosh (For An Ipo) On Pc Or Ipo (For Pc Or For A Password Saf ) On An Iphone Or

User Manual V1.0. Remote Software

NTI CORPORATION. NTI Backup Now EZ v3. User's Guide

Kaseya 2. Quick Start Guide. for VSA 6.1

WAM Remote Wireless Asset Monitoring. Website User Guide

QuickBooks Business Accounting Software for Windows

Event Log. Chapter 7 Event Log Event Log Management Excel Editing Create a New Event Log... 9

SIMRAD GB60 Glass Bridge system

How to Program a Commander or Scout to Connect to Pilot Software

Fax and SMS Quickguide

Kaseya 2. User Guide. Version 7.0. English

Velocity Web Services Client 1.0 Installation Guide and Release Notes

RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units

F re Alarm Network etwo (FAN) T rou rou h Virt Vi ual u Private Network etwo (VPN) Dr. Dr Sa S mir H. Abdull--Ja J u a wad

How to monitor servers, network devices and services for uptimes with Services Inspector and NetFort LANGuardian Aisling Brennan

Market Pricing Override

Managing Your Payment Matters

There are several ways of creating a PDF file using PDFCreator.

How To Make Templates More Powerful In Ec.Org

Integrating ConnectWise Service Desk Ticketing with the Cisco OnPlus Portal

Hot Spot (Unsecured) Wireless Access Initial Setup and Login for MCC_HOTSPOT

Authorware Install Directions for IE in Windows Vista, Windows 7, and Windows 8

Using Web Services for scanning on your network (Windows Vista SP2 or greater, Windows 7 and Windows 8)

SOFTWARE GUIDE PM1405 DATA PROCESSING SOFTWARE

1. What are popups? What if I have a problem with viewing popups? 1

AKCess Pro Server Acknowledge Alerts & Sensor Status Manual

BSDI Advanced Fitness & Wellness Software

Getting Started Guide. Chapter 14 Customizing LibreOffice

Enabling pop-up windows on different browsers

An Introduction to K12 s Online School (OLS)

3dCart Shopping Cart Software V3.X Gift Registry Guide

Right-click the Start button and select Properties. Click the Customize button and choose from the options displayed:

Using the Synchronization Client

Nintex Workflow 2010 Help Last updated: Friday, 26 November 2010

Working with SQL Server Integration Services

Petrel TIPS&TRICKS from SCM

Register Manufacturer: Click on Register Manufacturer radio button, choose the State name and click on Login Button. The following screen appears:

Procedure for updating Firmware of EZ4 W or ICC50 W

TrackRoad GPS User Guide

account multiple solutions

Event Log. Chapter 7 Event Log Event Log Management Excel Editing Create a New Event Log... 10

1 P a g e. Copyright CRMKnowledge.

The service note describes the basic steps to install a ip camera for the DVR670

28 What s New in IGSS V9. Speaker Notes INSIGHT AND OVERVIEW

Using the Remote Desktop Connection for Mac

Attix5 Pro Server Edition

Trading Integration for ViTrade

You may have been given a download link on your trial software . Use this link to download the software.

POS Connector Installation and Setup Guide

Attix5 Pro Server Edition

E-Map Application CHAPTER. The E-Map Editor

Instructions for Configuring a SAS Metadata Server for Use with JMP Clinical

MaxSea TimeZero NN3D Radar Connection Checklist

Basic 2D Design Be sure you have the latest information!

Using the Cisco CRM Communications Connector Client

Getting Started. A Getting Started Guide for Locum RealTime Monitor. Manual Version 2.1 LOCUM SOFTWARE SERVICES LIMITED

NEW FEATURE OVERVIEW SPRINGCM S APPROVAL WORKFLOW TOOL (AKA ROUTING AND APPROVAL WORKFLOW)

Chapter 7 Event Log Overview

Network Monitoring with SNMP

How To Use Touchtone.Com'S Digital Phone Service Web Portal User Guide (For Ip Phones) On A Pc Or Ip Phone (For A Cell Phone) On Pc Or Mac) On Your Ip Phone On A Mac Or Ip Cell Phone On

ELITE Ti Getting Started

Dashboard Designer. Introduction Guide. Basic step by step guide to creating a Dashboard. June 2012 V1.2

The types of alarm you can set. How to set up alarms. How to view triggered alarms. How to change the default settings for alarms.

Getting Started 2. Inserting a Digital Signature Field without Signing 3. Signing an Unsigned Digital Signature Field 3

Mail 8.2 for Apple OSX: Configure IMAP/POP/SMTP

Accounts Payable Workflow Guide. Version 11.2

Manual Password Depot Server 8

Lesson 15 - Fill Cells Plugin

USING THE RETENTION CENTER

1. Installing The Monitoring Software

Steps for those interested in starting to use quicken and quickbooks for their banking and financing.

Site Monitor. Version 5.3

Java. How to install the Java Runtime Environment (JRE)

Shard Web Trader Quick Start Guide

Quicken for Windows Conversion Instructions [Quicken for Windows WC to WC]

MAC OS X 10.5 Mail Setup

13 Managing Devices. Your computer is an assembly of many components from different manufacturers. LESSON OBJECTIVES

TABLE OF CONTENTS. INTRODUCTION... 5 Advance Concrete... 5 Where to find information?... 6 INSTALLATION... 7 STARTING ADVANCE CONCRETE...

AusCERT Remote Monitoring Service (ARMS) User Guide for AusCERT Members

8x8 Click2Pop User Guide

INTERCALL ONLINE Administrator Invoices User Guide

X-Trade Brokers Dom Maklerski S.A. XTB Expert Builder. Tutorial. Michał Zabielski

Transcription:

MaxSea version : TimeZero v2.1 (ECS/PLOT) Technical Note : MaxSea TimeZero Alarms Windows: Windows 7 / Windows 8 Update: September 2014 MaxSea TimeZero Alarms The Alarm options allow you to configure all of the various alarms and warnings that can be triggered by the software. Alarms are displayed at the very top of the screen. The Alarm Sound can then be customised for each individual Alarm. This allows you to trigger various sounds according to the type of Alarm. Alarm types The Alarm options allow you to configure all of the various alarms and warnings that can be triggered by the software : XTE Alarm (Cross Track Error) Alarm Zone Depth Alarm Sea Surface Temperature Alarm Speed Alarm CPA/TCPA Alarms AIS Alarms Anchor Watch Alarm XTE Alarm (Cross Track Error) An alarm is triggered when the vessel has strayed a designated distance "XTE Alarm Value" from the active route. Note: you can display a graphic representation of the Cross Track Error limit on the chart by enabling the "Display XTE Alarm Lines" which is available in the Route options. As soon as the boat is out of the XTE limit, the alarm will be displayed in red, on the top of the screen, and when enabled the alarm sound is triggered. 1985-2014 MaxSea International - supportpro@maxsea.fr - 1

Alarm Zone The user can create a Boundary Area on the chart and then set it as an Alarm Zone by right-clicking on it and selecting "Alarm". When an alarm zone is activated, the contour line of the area will blink Once Boundary Alarms are created, the "Alarm Zone" setting will define their behaviour: OFF: No alarm will be triggered even if the boat enters an Alarm Zone ON: An alarm will be triggered as soon as the boat enters any Alarm Zone Progressive: When the boat reaches the distance set in "Progressive Alarm Zone Value" from any Alarm Zone: A notification will be displayed A distance and bearing vector is displayed on the chart between vessel and surface Note: Dedicated NavData ("Alarm Zone NavData") can be setup to display the distance from the nearest Alarm Zone at any time. When the boat enters any Alarm Zone, the alarm will be triggered. 1985-2014 MaxSea International - supportpro@maxsea.fr - 2

Depth Alarm An alarm is triggered when the vessel passes over water that is shallower than a designated depth value. Note: The alarm is triggered according to depth information received from the sounder only. Sea Surface Temperature Alarm An alarm is triggered when a specific condition regarding Sea Surface Temperature (SST) value is met. The alarm status can be set from the SST Alarm dropdown menu: Off: to disable the SST alarm Over: SST is above the defined Temperature Alarm Value Under: SST is below the defined Temperature Alarm Value Within: SST is included between Minimum and Maximum range Values defined Out Of: SST is out of the Minimum and Maximum defined range values Speed Alarm An alarm is triggered when a specific condition regarding the speed value of your vessel is met. The alarm status can be set from the Speed Alarm dropdown menu: Off: to disable the Speed alarm Over: Speed is above the defined Speed Alarm Value Under: Speed is below the defined Speed Alarm Value Within: Speed is included between Minimum and Maximum range Value defined Out Of: Speed is out of the defined Minimum and Maximum range values 1985-2014 MaxSea International - supportpro@maxsea.fr - 3

CPA/TCPA Alarms CPA/TCPA Alarm/Display Value Defines the CPA and TCPA values for which a target is considered dangerous and displayed in red on the chart. CPA/TCPA Alarm An alarm is triggered when a target becomes dangerous. AIS Alarms Proximity AIS Target Alarm An alarm is triggered when the vessel moves within the designated distance from an AIS target. Ignore for AIS slower than... Use this setting to prevent AIS targets that are not moving from triggering the proximity or CPA/TCPA alarm. This setting is very useful in harbor to prevent safe target (moored or docked boat) from raising unwanted alarms. 1985-2014 MaxSea International - supportpro@maxsea.fr - 4

Anchor Watch Alarm An alarm is triggered when the vessel strays a designated distance from where the user set anchor. You can enable/disable the Anchor Alarm by right-clicking directly on the Own Ship icon. When activated, an orange dotted circle is displayed around the boat. When alarm is triggered the circle blinks red Alarm Sounds The Alarm Sounds option allows the user to assign a sound to various alarms. 10 predefined sounds are installed within the software. Define Alarm Sounds Alarm Define Sounds button allows you to open the dialog box allowing the user to customise the sound independently for every Alarm. To define Alarm sound: - Select the alarm from Alarm Name column - Click on the corresponding Sound dropdown menu - Select one of the 10 sounds from the list When selected, you can listen to the sound by clicking the play button. Note: It is possible to replace the default sounds by overwriting the sound files located in C:\Program Files (x86)\maxsea International\MaxSea Professional\Sounds\ Sound Alarm Until Acknowledged: When this setting is checked, the Alarm Sound will repeat over and over until the user acknowledges the alarm: by clicking on the status bar or by checking "Acknowledge" from the Alarm List 1985-2014 MaxSea International - supportpro@maxsea.fr - 5