Cable Specifications. T3 Trunk Cabling APPENDIX



Similar documents
Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.

Cable Pinouts. SRP I/O Module

Cable Specifications and Information

Connector and Cable Specifications

Connector and Cable Specifications

Cabling Specifications

Cable Specifications and Information

Connectors and Cables

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

RS-232 COMMUNICATIONS

Making a DB to RJ45 adapter.

Cisco - Ethernet 100BaseTX and 10BaseT Cables: Guidelines and Specifications

FlexPoint T1/E1 Copper to Fiber Line Driver

Encore Controller to Router Connections

Comtrol Cable User Guide

RJ45 Shielded (standard) port pinout. CS9000, Jetstream , Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

RJ11 RS-232 Interface

Cable Specifications

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

24-Port Channelized E1/T1 Line Card Overview

Cabling Guide for Console and AUX Ports

RS-232 Cables, Wiring and Pinouts. Brief tutorial and pinouts for RS-232, T1/E1 and V.35. Contents

Loop-IP6702 TDMoEthernet

Optimux-34, Optimux-25

Adit 600 Product Guide

Cable Guide For all PortServer TS, Digi Connect, and Digi One Products

Cable Guide For all PortServer TS, Digi Connect, and Digi One Products

F2400 FOM II Series Fiber Optic Modem Technical Manual

Connecting Serial Interface Cards to a Network

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Sentry. Remote Power Manager. Installation and Setup Manual

Optimux-134, Optimux-125

Loop-V4300 MINI DACS E1/ T1 CONVERTER

Cable Guide Including all PortServer TS, Digi Connect, and Digi One Products

Product Overview. Features CHAPTER

Serial Cables & Adapters

Cisco T1 Layer 1 Troubleshooting

Optimux-134, Optimux-125

Overview. Port Adapter Overview CHAPTER

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

G.703 Fractional T1 Access Unit. User Guide

CX-U Series Hardware Reference Manual

Chapter 4 T1 Interface Card

IMACS. Cable and Equipment Guide. Premisys Communications. Integrated Multiple Access Communications Server. Publication Revision A2

T1 Backhaul Connectivity Solution All Products :: Application Note

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

Contract Number NNG07DA20B NASA SEWP IV

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200

Module Connectors and Cable Specifications

Appendix A. This Appendix includes the following supplemental material:

Modbus Communications for PanelView Terminals

Loop-IP6700 TDMoEthernet

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

FOM-5A, 6A. Asynchronous Fiber Optic Modem

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

Loop-IP6700 TDMoEthernet

TDMoEthernet. Description

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

Cables and Connectors

Telephone- and leased line modem for industrial applications TD-36

USER MANUAL. MODEL 1082/F idsl Modem with G.703 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

Manual Serial PCI Cards

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

MCR1900 Media Converter 19-Slot Chassis

Rack mounted telephone- and leased line modem for industrial applications

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

PCS0100en Persy Control Services B.V. Netherlands

1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

Advanced Data Capture and Control Systems

Optimux-1553 Fiber Multiplexers for 3 E3/T3 over STM-1/OC-3

T-Extender E-Extender

XPort Universal Demo Board User Guide

Long Range Ethernet Extender

Bluetooth Serial Adapter

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

isco Connecting Routers Back to Back Through the AUX P

Connecting the Console Port to a PC

These highly flexible interface cards facilitate several important applications:

GM1200E Interface Cable

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Telebyte 209 Short Haul Modem

Application Note 83 Fundamentals of RS 232 Serial Communications

2100 POS System User Guide

Cables KEITHLEY (U.S. only) ACCESSORIES

Cisco 1603 R Ethernet/ISDN BRI Modular Router Cable Specifications

DSX Master Communications

CDI-S100 SERIAL INTERFACE CARD

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

CAMPUS-RS CSU/DS-1 INTERFACE CARDS

Transcription:

APPENDIX B This appendix contains details on the MGX 8230 cabling. It includes the following sections: T3 Trunk Cabling Frame Relay Cabling DC Power Cabling AC Power Cabling Control and Clock Cabling External Alarm Cabling Note In all cable references, the transmit direction is away from the MGX 8230, and the receive direction is toward the MGX 8230. T3 Trunk Cabling A trunk cable connects each T3 port on the BNC-2T3 back card to a T3 port on other equipment. See Table B-1 and Table B-2 for details. Table B-1 Trunk Cables Type Max. Length Connector 75-ohm coax cable (RG-59 B/U for short runs, AT&T 734A for longer runs). Two per T3 line (XMT and RCV). 450 feet maximum between the MGX 8230 and other equipment. Terminated in male BNC; Rx is received from trunk, Tx is transmitted to trunk. Table B-2 Connector Rx BNC Tx BNC T3 Connector Pin Assignments Receive T3 from trunk Transmit T3 to trunk B-1

Frame Relay Cabling Appendix B Frame Relay Cabling T1 Cabling Trunk cables connect the customer DSX-1 cross-connect point or T1 Channel Service Unit (CSU) to the MGX 8230 at the T1 back card. See to Figure B-1 and Table B-3 for details. Cable Type Cable Connector Max. Cable Length Western Electric 22 AWG, ABAM individually shielded twisted pair (100 ohm balanced). Two pair per T1 line (1 transmit and 1 receive). RJ-48C male. (Figure B-1 illustrates the RJ-48 connector pin out.) 655 ft. (199.664 m) maximum between the MGX 8230 node and the first repeater or CSU. Selection of cable length equalizers. Table B-3 RJ-48C T1/E1 Connector Pin Assignments Pin No. 1 Transmit Tip 2 Transmit Ring 3 Transmit Shield 4 Receive Tip 5 Receive Ring 6 Receive Shield Note Transmit direction is toward the T1 trunk. B-2

Appendix B Frame Relay Cabling Figure B-1 RJ-48 Connectors E1 Cabling SMB Connector E1 trunk cables connect the customer DSX-1 cross-connect point or E1 Channel Service Unit (CSU) to the node at the FRSM E1 back card (SMB-8E1). See Table B-4 and Table B-5. Table B-4 E1 Trunk/Circuit Line Cabling Specification Cable Type (BNC-8E1) Cable Connector Max. Cable Length 75-ohm coax cable for unbalanced connection. Two cables/pairs (1 transmit, 1 receive) per E1 line. 16 female SMB for unbalanced connection. See Tables A-2 and A-4 for pinouts. Approximately 100 meters maximum between the MGX 8230 node and the first repeater or CSU. Equalizer for cable length. Table B-5 Connector Rx BNC Tx BNC E1 Connector Pin Assignments (unbalanced) Receive E1 from trunk Transmit E1 to trunk HSSI Port Connectors The High Speed Serial Interface (HSSI) port connects through a female SCSI-II connector This connector accords with ANSI/TIA/EIA-613. See Table B-6 for the pinouts. B-3

DC Power Cabling Appendix B Table B-6 Pinouts for SCSI-II Connector Pin No. Name Signal Function Polarity Signal Source 11 SD Send Data + DTE 36-4 RD Receive Data + DCE 29-6 ST Send Timing + 31-2 RT Receive Timing + 27 _ 6 TT Terminal Timing + DCE 13-3 CA DCE Available + DCE 28-8 TA DTE Available + DTE 33-10 LA Loop Ckt A + DTE 35-12 LB Loop Ckt B + DTE 37-5 LC Loop Ckt C + DCE 30 - SG Signal Ground DC Power Cabling DC Power connections are made to the DC Power Entry Modules at the rear of the MGX 8230. See Table B-7 and Table B-8 for acceptable cable and wire types. Cisco normally does not provide wiring for DC-powered systems. See Table B-7 for details on DC wiring. Table B-7 DC Power Wiring Wiring Connection Three conductor, 10 AWG recommended wire gauge, min. 60 C insulation rating, copper conductors only. Solid or stranded wires. Wire insulation stripped back 0.25 (6 mm) at the MGX 8230 connector end. EURO Block. B-4

Appendix B AC Power Cabling AC Power Cabling Either Cisco Systems or the customer can provide the AC power cord. See Table B-8 for the power cords that Cisco can supply. In addition, you can special-order AC cables with other plugs or different lengths. If you want to construct the power cord, it must mate with an IEC320 (C-14) 10/15A male receptacle on the back of the AC power module. Table B-8 AC Power Cables Cable Plug (customer end) Provided with 8 feet (2.3 m) of 3-conductor wire with plug. 20 A NEMA L620, 3-prong plug (domestic U.S.) Need 15A NEMA 5-15 for US and Canada. 13 A 250 Vac BS1363, 3-prong fused plug (UK, Ireland) CEE 7/7 (Continental Europe) AS3112 (Australia/New Zealand) CEI23-16/VII (Italy) 125V/15A North America Control and Clock Cabling This section describes the cables that can connect to the PXM-UI card. Maintenance and Control Ports The Maintenance (or Modem) port and the Control (or Console) port connect an MGX 8230 to an ASCII terminal, workstation, or modem for remote alarm reporting or system monitoring. Refer to Table B-9 for a description of the cabling and Table B-10 for the pinout of the associated RJ45 connector. Table B-9 Maintenance and Control Port Cabling Interface EIA/TIA-232 both are DTE ports. Suggested Cable 24 AWG, 8-wire. A straight-through EIA/TIA-232 cable provides a terminal or printer connection. For an interface with modems on either port, a null modem cable may be necessary. Cable Connector RJ45, subminiature, male. Table B-10 contains a list of the port pin assignments. Max. Cable Length 50 feet (15 m) Table B-10 RJ-45 Maintenance and Control Port Pin Assignments Pin No. Name 1 RTS out Request to Send 2 DTR out Data Terminal Ready B-5

Control and Clock Cabling Appendix B Table B-10 RJ-45 Maintenance and Control Port Pin Assignments (continued) Pin No. Name 1 RTS out Request to Send 3 TxD Transmit Data 4 GND Signal Ground 5 GND Signal Ground 6 RxD Receive Data 7 DSR Data Set Ready 8 CTS Clear to Send External Clock Input Cabling The MGX 8230 has two external clock input connectors: a T1 RJ-45 connector and E1 SMB connector. T1 Clock Cabling The clock port can accept a T1 or E1 BITS clock input. (See Table B-11) Table B-11 7T1 Clock Cabling Pin No. Name 1 Tx ring out 2 Tx tip out 3 Ground 4 Rx ring in 5 Rx tip in 6 No comment 7 Test point ring out 8 Test point tip out B-6

Appendix B External Alarm Cabling External Alarm Cabling The external alarm cable connects to the Alarm connector on the PXM-UI card. See Table B-12 for physical characteristics of the cable and Table B-13 for the pinouts. Table B-12 External Alarm Cabling Interface Wire Connector Dry-contact relay closure. 24 AWG, shielded, 6-pair. DB-15, Subminiature, male. Table B-13 Network Alarm Pin Assignments Pin No. Alarm 1 Audible Major Normally open 2 Common 9 Normally closed 4 Visual Major Normally open 5 Common 12 Normally closed 7 unused n.c. 8 unused n.c. 3 Audible Minor Normally open 11 Common 10 Normally closed 6 Visual Minor Normally open 14 Common 13 Normally closed 15 unused n.c. B-7

External Alarm Cabling Appendix B B-8