Workflow Solutions Data Collection, Data Review and Data Management



Similar documents
Sage Grant Management System Requirements

Delphi+ System Requirements

General Hardware Requirements Workstation Requirements Application / Database Server Requirements Storage Requirements...

Priority Pro v17: Hardware and Supporting Systems

Exhibit B5b South Dakota. Vendor Questions COTS Software Set

Minimum System Requirements

Delphi 2015 SP1-AP1 System Requirements

ShadowLink 2. Overview. May 4, ONLINE SUPPORT emdat.com/ticket/ PHONE SUPPORT (608) ext. 1

Point & PointCentral 9.1

AP ENPS ANYWHERE. Hardware and software requirements

Kaseya IT Automation Framework

inforouter V8.0 Server & Client Requirements

Minimum System Requirements

Web Server (IIS) Requirements

Grant Management. System Requirements

Backup Exec System Recovery Management Solution 2010 FAQ

Delphi System Requirements

Interact Intranet Version 7. Technical Requirements. August Interact

Océ PRISMA access BUSINESS CONTROL. Order submission and workflow management made easy

McKesson Radiology 12.0 Technical Requirements

Centricity 360 Case Exchange

WINSCRIBE HARDWARE SPECIFICATIONS

MedInformatix System Requirements

How To Run A Pacemar Optima System On A Microsoft Powerbook 2.5 (Powerbook) With A Powerbook 1.5 And Powerbook 3.5 On A Pc Or Macbook 2 (Powerstation) With An

INSTALLATION MINIMUM REQUIREMENTS. Visit us on the Web

Abila Grant Management. System Requirements

Compulink Advantage Cloud sm Software Installation, Configuration, and Performance Guide for Windows

About This Manual. 2 About This Manual

Paceart Optima System 1.4 TECHNICAL REQUIREMENTS

Table of Contents. Introduction...9. Installation Program Tour The Program Components...10 Main Program Features...11

Network device management solution

Synergis Software 18 South 5 TH Street, Suite 100 Quakertown, PA , version

Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.

Minimum Software and Hardware Requirements

Item Minimum Required Recommended Notes


CBE system requirements

Server Installation Procedure - Load Balanced Environment

Reform PDC Document Workflow Solution Streamline capture and distribution. intuitive. lexible. mobile

Minimum Management Requirements

Professional and Enterprise Edition. Hardware Requirements

System Planning, Deployment, and Best Practices Guide

Symantec Backup Exec.cloud

System Requirements - filesmart

Compulink Advantage Online TM

Priority Zoom v17: Hardware and Supporting Systems

Hardware and Software Requirements. Release 7.5.x PowerSchool Student Information System

Terminal Server Software and Hardware Requirements. Terminal Server. Software and Hardware Requirements. Datacolor Match Pigment Datacolor Tools

RightNow November 09 Workstation Specifications

COMMUNICATION SERVER 1000 COMMUNICATION SERVER 1000 TELEPHONY MANAGER

System Requirements. SuccessMaker 5

Softline VIP Payroll System Requirements v2.9a January 2010

To ensure you have the appropriate equipment and settings please review the following: Software and Hardware Recommendations.

Proval LS Database & Client Software (Trial or Full) Installation Guide

SQL Server 2008 R2 Express Installation for Windows 7 Professional, Vista Business Edition and XP Professional.

NETWRIX EVENT LOG MANAGER

3M Command Center. Installation and Upgrade Guide

Insight HealthCare Information Systems OmniCare 7.3 Update Overview

The Education Edge / The Financial Edge 7.85

Lytec 2014 Hardware and Software Requirements. Lytec Single-User Hardware and Software Requirements

AuditMatic Enterprise Edition Installation Specifications

Software Update Bulletin

Adept 2014 System Requirements

Ensure that the server where you install the Primary Server software meets the following requirements: Item Requirements Additional Details

NVivo Server 10 R2 INSTALLATION AND SET UP GUIDE

Sage 300 ERP 2014 Compatibility guide

PaperSave IT Prerequisites for Blackbaud s The Financial Edge

UPK and UPK Professional Technical Specifications

Kaspersky Endpoint Security 10 for Windows. Deployment guide

Microsoft Windows Apple Mac OS X

Sage 100 Premium ERP Version 2015 Supported Platform Matrix Created as of April 6, 2015

INSTALLATION AND SET UP GUIDE

PVTC Technical Requirements

INSTALLING SQL SERVER 2012 EXPRESS WITH ADVANCED SERVICES FOR REDHORSE CRM

Sage MAS 200 ERP Level 3.71 Version 4.30 Supported Platform Matrix

Sage BusinessWorks Accounting 2013 System Standards

Asta Powerproject Enterprise

How to Install and Set Up the FASTER Dashboard

Ultra Thin Client TC-401 TC-402. Users s Guide

PC Business Banking. Technical Requirements


McKesson Radiology Technical Requirements

Networking Best Practices Guide. Version 6.5

CONSTRUCTION / SERVICE BILLING SYSTEM SPECIFICATIONS

Cross-channel protection GSelector s exclusive cross-station protection prevents the same song from playing at the same time across your stations.

Customer Site Requirements for incontact Workforce Optimization

Central Management System

Sage 100 Premium Version 2016 Supported Platform Matrix Created as of November 25, 2015

Upgrade to Webtrends Analytics 8.7: Best Practices

User Installation Guide

Network device management solution.

Intel Pentium IV or compatible 1 gigahertz (GHz) or higher processor

Backup and Recovery. Backup and Recovery. Introduction. DeltaV Product Data Sheet. Best-in-class offering. Easy-to-use Backup and Recovery solution

Technical Guide. Distributed by Kowa Optimed

WEB COMPAS MINIMUM HOSTING REQUIREMENTS

Cisco IP Communicator (Softphone) Compatibility

Brainlab Node TM Technical Specifications

Transcription:

Data Collection, Data Review and Data Management Workflow Finding more efficient ways to support patient needs begins with better workflow management. MGC Diagnostics has developed a complete workflow system which combines healthcare industry standards and best practices with flexibility and support. MGC Diagnostics makes it easy to build and customize powerful workflow solutions to save time and effort allowing the focus to be on the patient. MGC Diagnostics flexible workflow solutions are separated into 3 categories: Data Collection, Data Review and Data Management. Data Collection [ BreezeSuite Cardiorespiratory Diagnostic Software ] The heart of MGC Diagnostics workflow solutions package is BreezeSuite cardiorespiratory diagnostic software. This versatile software combines gas exchange and pulmonary function testing into one powerful application that sets a new standard for ease of use. The easy to use Windows based system contains extensive options for predicteds, customizable displays and reports and integrated software options. BreezeSuite cardiorespiratory diagnostic software provides several technological advantages: Complete Microsoft Windows operating system package allows for industry standard integration with Windows operating system compatible printers, fax machines, email systems and more. The utilization of Microsoft SQL Server results in significant performance gains. Data storage capacity only limited by available drive space. Support for Wide Area Networks (WAN). [ Open SQL Database ] MGC Diagnostics believes that the data belongs to the facility and should not be controlled in any way by any manufacturer. An open SQL database architecture allows authorized individuals to develop and run queries. This truly open SQL Database assures data will always be accessible to the user. Data is not MGC Diagnostics encrypted or dependent in any way. Data Review [ BreezeSuite WebReview Physician Review Software ] With BreezeSuite WebReview physician review software, physicians are able to review, interpret and electronically sign tests from the clinic, hospital, office or home from any Windows based web browser. Results can be posted through BreezeConnect HL7 interface software to the EMR system. Secure access is userauthenticated to meet HIPAA requirements and the HITECH Act. [ BreezeReview Physician Review Software ] BreezeReview physician review software combines workstations with review stations. All workstations and review stations share the same database. A physician can review, interpret, change review status, and electronically sign tests as the workflow dictates within the network. Results can be posted through BreezeConnect HL7 interface software to the EMR system. BreezeReview physician review software satisfies both HIPAA requirements and the HITECH Act and can be installed on a Citrix server (Citrix BreezeReview physician review software option required).

Data Review (continued) [ Citrix BreezeReview Physician Review Software ] With Citrix BreezeReview physician review software, BreezeReview physician review software can be accessed so tests can be remotely reviewed, interpreted, electronically signed and review status changed from any Internet connection. Results can be posted through BreezeConnect HL7 interface software to the EMR system. Data Management [ BreezeSuite MultiUser Networking Software ] BreezeSuite MultiUser networking software connects cardiorespiratory diagnostic systems and review stations so data can be shared and stored in a central Microsoft SQL Server database. This networking software allows all workstations to share one database from either a local area network (LAN) or a wide area network (WAN). Reports, reference values, and statements can be standardized from each site. With an enterprise friendly approach, IT/IS departments can use their approved hardware without separate vendor hardware. BreezeSuite MultiUser networking software provides the following benefits: Retrieve, interpret or trend data from any networked PC - minimizing the need to handle and manage paper reports. Review historical patient data without interrupting diagnostic assessments. Automated backup of electronic storage reduces the risk of lost or misplaced records and the added expense of retesting. Easy-to-use physician review workstations allow rapid turnaround of test interpretations on the network. Electronic environment improves workflow and productivity, which saves on transcription, filing and paper storage costs. [ BreezeConnect HL7 Interface Software ] BreezeConnect HL7 interface software allows any number of networked systems to send or receive data from the facility s electronic medical records (EMR) system. The interface software is compatible with most commercial and facility-developed hospital information systems (HIS), allowing access to patient information from any location tied to the facility s EMR system. Here s how it works. Patient orders and patient demographics (ADT) are received on a workstation. After the test is completed and interpreted, the test data, PDF report, text report or a combination of these is sent to the EMR system. BreezeConnect HL7 interface software also provides the following advantages: Automatic data transfer and entry is time-efficient and reduces the unnecessary expense of errors and misplaced test retrieval. Eliminates the need to configure or customize programming to covert HL7 data. Patient identification numbers, demographics (ADT) and physician orders (ORM) can be downloaded to the MGC Diagnostics BreezeSuite cardiorespiratory diagnostic software database. Patient test results (ORU) and interpreted reports can be uploaded to the EMR system. Utilizes HL7 2.x protocols as well as TCP/IP and MLLP (minimal lower layer protocol) for data transfer. 2

How it Works EMR/HIS HL7 Orders BreezeConnect HL7 interface software TCP/IP BreezeSuite cardiorespiratory diagnostic software SQL database TCP/IP BreezeSuite WebReview physician review software HL7 Results TCP/IP Internet BreezeSuite cardiorespiratory diagnostic software Workstations BreezeReview physician review software Workstation HTTPS BreezeSuite WebReview physician review software Client Information Flow 1. Patient ADT (Demographics) or Orders are sent from the EMR to the BreezeConnect HL7 interface software. 2. The patient ADT or Orders are sent from the BreezeConnect HL7 interface software to BreezeSuite MultiUser SQL database. Electronic Medical Records (EMR) 1 6 BreezeConnect HL7 interface software 3. The appropriate fields in BreezeSuite cardiorespiratory diagnostic software are populated with Patient Demographics and/or Orders. 2 BreezeSuite MultiUser Networking Software 5 4. Operator performs requested patient tests. 5. The preliminary or final test result is released by the operator or physician. 3 4 BreezeSuite cardiorespiratory diagnostic software Workstation BreezeSuite cardiorespiratory diagnostic software Workstation BreezeSuite cardiorespiratory diagnostic software Workstation 6. Results are converted to HL7 and sent to Electronic Medical Records (EMR). Additionally, reports containing graphics may be sent via PDF file in the HL7 message to the EMR. 3

Electronic Physican Order Entry BreezeSuite cardiorespiratory diagnostic software displays patient tests ordered by the clinician. Frequently Asked Questions (FAQs) Q. Can the MGC Diagnostics database and the BreezeConnect interface reside on a shared server? A. Yes. Q. If on a Virtual Machine server, can the database and interface still reside on the same OS? A. Yes. Q. Are there regular updates to the interface software? If yes, what is the notification process and the cost? A. Customers under contract with the Annual Support Agreement will receive updates to the interface when available. For updates (does not include new services or applications), customer will be notified by email and letter and there will be no charge. Q. What type of support is provided for the interface? A. Customers with an Annual Support Agreement will receive no-charge 24/7/365 telephone support and remote support assistance where available. On-Site support is available for an additional fee. Q. Is the interface compatible with various backup programs? A. The interface has its own backup utility for its databases. Q. What provisions are available for disaster recovery in the event of such an occurrence? A. Critical files can be backed up to a remote server. Q. Will it be necessary for the interface to connect to the vendor via the internet and will an internet browser be used to access or support any portion of the interface? A. An internet connection is used for remote installation and service. It is not required for routine operation. Q. Are there any concerns with Antivirus applications? A. There are file exclusions that need to be in place for any scanning software. Q. Who is going to install the interface software? A. The BreezeConnect HL7 Interface software will be installed by MGC Diagnostics. The purchase includes remote installation, or for an additional charge, onsite installation. Q. Who is responsible for the interface software? A. Support for the interface is provided by MGC Diagnostics and Data Innovations with the purchase of the Annual Support and Maintenance Agreement. Q. Is the interface designed to be used in a WAN environment? A. It can be used in a WAN environment, but due to bandwidth and latency issues the refresh of data may be longer than over a LAN. Q. Does the interface maintain an audit trail that provides documentary evidence of user transactions? A. Yes, in the Event Log. Q. Are all interfaces HL7 compatible and, if so, what version? A. Data to the EMR can be in HL7 format, however this depends on the customer. Standard HL7 interfaces currently available are HL7 2.X. 4

Application Rapid Access to Patient Data We want to bring a patient into any testing room and pull up their historical test results or view spirometry data from the Pulmonary Lab when the patient arrives for a test in Cardiology. BreezeSuite MultiUser networking software Install networking software on MGC Diagnostics systems and connect to a centralized database located on a server. Patient data can now be retrieved and viewed on any testing system or department workstation connected to the network without interrupting workflow. Faster Turnaround of Reviews and Interpretations Our doctors want to review, interpret and save test data from their office or home. Wider Availability to Patient Test Results We want to get our final reports into the EMR so it can be viewed from anywhere in the hospital. BreezeSuite MultiUser networking software BreezeReview physician review software and BreezeSuite WebReview physician review software Create a BreezeSuite MultiUser diagnostic system network and add BreezeReview physician review software to computers on the network. Physicians can now retrieve, interpret and trend patient results in their office, eliminating the need to manage paper reports. This accelerates completion of interpretations and makes the diagnosis available for rapid clinical follow up. Additionally, BreezeSuite WebReview physician review software allows the physician to use an internet connection and web browser to connect to the BreezeSuite database. Patient data can be reviewed and interpretation can be performed from any location and from any computer using Windows based web browsers. BreezeSuite MultiUser networking software with BreezeConnect HL7 interface software Using the BreezeConnect HL7 interface software, patient results can be sent from the BreezeSuite MultiUser network to the EMR for viewing on any EMR workstation. Enhanced Workflow and Reduced Errors We need to reduce entry errors and add the efficiency of entering new patient demographics by accessing the information electronically. BreezeSuite MultiUser networking software with BreezeConnect HL7 interface software With BreezeConnect HL7 interface software, patient demographic records and physician orders can be sent to the BreezeSuite MultiUser central database for access at the diagnostic workstation. 5

Specifications [ SYSTEM SPECIFICATIONS FOR BREEZESUITE MULTIUSER NETWORKING SOFTWARE SERVER ] Network 64-bit OS Support SQL Server Versions Supported SQL Server Configuration BreezeSuite SQL Database Windows Server 2003/2003 (R2) Windows Server 2008/2008 (R2) 2.0 GHz or faster recommended 40+ GB recommended 1 GB minimum 4+ GB recommended Network Interface Card Installed TCP/IP networking installed DHCP or static IP Address Yes Yes SQL Server 2005 (Workgroup, Standard or Enterprise edition) SQL Server 2008 (Workgroup, Standard or Enterprise edition) SQL Server 2008 (R2) (Workgroup, Standard or Enterprise edition) SQL Server is installed with SQL or Mixed Mode Authentication TCP/IP protocol enabled on Server Service and Native Client Service Named Pipes protocol enabled on Server Service and Native Client Service BreezeSuite cardiorespiratory diagnostic software databases require approximately 50 MB disc space when empty Database size growth should be expected at approximately 1 GB per 5000 patient tests stored Total space requirements will depend on archived data size, testing volume and database maintenance MGC Diagnostics recommends allocating 20+ GB for BreezeSuite MultiUser networking software databases [ SYSTEM SPECIFICATIONS FOR BREEZESUITE WORKSTATION ] Windows Display Properties Other Hardware Network System Type Windows XP Professional SP3 Windows 7 Professional SP1 Windows 7 Ultimate SP1 Pentium IV 2.8 GHz or greater minimum Intel Core Duo or greater recommended 40 GB minimum 80+ GB recommended 1 GB minimum 3+ GB recommended 1024 x 768 minimum resolution CD/DVD Drive 3+ USB ports 8+ USB ports for Ultima Series cardiorespiratory diagnostic systems Network Interface Card Installed TCP/IP networking installed DHCP or static IP Address x86 (32-bit) and x64 (64-bit) PC hardware and operating systems are supported NOTE: Ultima CardiO 2 gas exchange analysis systems DO NOT support x64 (64-bit) operating systems 6

Specifications (continued) [ SYSTEM SPECIFICATIONS FOR BREEZESUITE WEBREVIEW PHYSICIAN REVIEW SOFTWARE ] Windows Display Properties Server Prerequisites Supported Internet Browsers 64-bit OS Support BreezeSuite WebReview Required Browser Plug-Ins Windows Server 2008/2008 (R2) Standard Windows Server 2008/2008 (R2) Enterprise 2.0 GHz or faster recommended 10 GB minimum 40+ GB recommended 2 GB minimum 4+ GB recommended 1024 x 768 minimum resolution Latest Microsoft updates installed Microsoft.NET Framework 4 ASP.Net 4.0 Microsoft Internet Information Server (IIS) Version 7 SSL Certification for use with BreezeSuite WebReview physician review software has been obtained and installed (optional) Internet Explorer Chrome Firefox Yes Yes Silverlight 5+ [ SYSTEM SPECIFICATIONS FOR CITRIX BREEZEREVIEW PHYSICIAN REVIEW SOFTWARE ] Windows Display Properties Network 64-bit OS Support SQL Server Configuration Windows Server 2003/2003 (R2) Windows Server 2008/2008 (R2) 2.0 GHz or faster recommended 10 GB minimum 40+ GB recommended 1 GB minimum 3+ GB recommended 1024 x 768 minimum resolution Network Interface Card Installed TCP/IP networking installed DHCP or static IP Address Yes Yes Yes SQL Server is installed with SQL or Mixed Mode Authentication SQL Server named instance installed with instance name = MGCSQLServer TCP/IP protocol enabled on Server Service and Native Client Service Named Pipes protocol enabled on Server Service and Native Client Service 7

Specifications (continued) [ PERFORMANCE SPECIFICATIONS FOR CITRIX BREEZEREVIEW PHYSICIAN REVIEW SOFTWARE ] BreezeReview Process CPU Usage BreezeReview Process Usage BreezeReview Process Disk I/O Speed Minimum - 1.5 MHz Average - 450 MHz Maximum - 3500 MHz Minimum - 75 Kb Average - 140 Kb Maximum - 600 Kb Average - 50 B/sec Read Maximum - 500 B/sec Read 7200 RPM [ SYSTEM SPECIFICATIONS FOR BREEZECONNECT HL7 INTERFACE SOFTWARE SERVER ] Speed EMR/HIS Connectivity Other (Software) Other (Hardware) Windows Server 2003 or Server 2003 (R2), Standard edition (32-bit) Windows Server 2003, Enterprise edition (32-bit) (Service Pack 2) Windows Server 2008, Standard edition (32-bit) Windows Server 2008 or Server 2008 (R2), Standard edition (64-bit) Pentium 4-2.8 GHz or greater 80 GB NOTE: Additional hard disk space is required based on the amount of data to retain and duration. 7200 RPM NOTE: Faster hard drive speeds correspond to improved performance 1 GB minimum 3+ GB recommended Options include: Client/Server connectivity via TCP/IP (Static IP address) or file exchange Internet Explorer 7 or greater NOTE: Hardware running InterSystems Caché database for other applications cannot be used on the same platform. Monitor (1024 x 768) minimum resolution) Yes MGC DIAGNOSTICS CORPORATION, through its subsidiary Medical Graphics Corporation 350 Oak Grove Parkway St. Paul, Minnesota USA 55127-8599 2013 MGC Diagnostics Corporation or one of its affiliates. All rights reserved. All specifications subject to change without notice. Products may vary from those illustrated. MGC Diagnostics and its affiliates are equal opportunity/affirmative action employers committed to cultural diversity in the workforce. Part# 060088-001 RevG