Symmetra PX UPS. 10-80 kw 208 V. Operation and Maintenance Manual



Similar documents
Symmetra LX. Operations Guide

Triple Expansion Chassis

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Installation Guide Smart-UPS X External Battery Pack SMX120BP

Unpacking, Installation, and Customization

MGE Galaxy 3500 Series kva 380/400/415 V kva 208/220 V. Operation

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

Out-of-Band Management Card

CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury.

APC Step-Down Transformer. User s Manual

Galaxy kva 380/400/415 V and kva 208/220 V. Operation 09/

Installation. Basic Rack Power Distribution Unit AP9559

Network Management Card. Installation and Quick Start Manual

Configurable Events for APC Network Management Card

Back-UPS Pro 1300/1500 Installation and Operation

Installation and Operation Back-UPS 1250, 1300, 1500

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Advantium 2 Plus Alarm

Operation Manual. Smart-UPS X Uninterruptible Power Supply

PK5500 v1.1 Installation Instructions

Crow Limited Warranty. Print Version 017

Ambient Temperature In Range Probe X

User Manual. Smart-UPS TM C. Uninterruptible Power Supply SRC250 SRC /120/230 Vac. Tower/Rack-Mount 1U

How to Set Up Your NSM4000 Appliance

HP R12000 and R18000 DirectFlow UPS User Guide

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

, User s Manual

Dolphin 9900 Mobile Computers

LCD5500Z / PKP-LCD v3.x Installation Instructions

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

Installation and Operation

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Operation Manual. Smart-UPS UPS. 750/1000/1500/2200 VA Rack-mount 2U 120/230 VAC VA Rack-mount 2U 120/208/230 VAC

Metered Rack Power Distribution Unit

How To Install A Power Supply (Uplast) With A Battery Pack

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

Automatic Phone-Out Home Monitoring Systems

FXM Communication Manual

Smart-UPS VT kVA 400V. Site Preparation and Installation Manual

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

HYBRID NETWORK VIDEO RECODERS WITH INTERNAL RAID RECOVERY PROCEDURE

AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

BW TECHNOLOGIES GasAlertMicroClip Soft Tools Instruction Sheet

StorTrends 3400 Hardware Guide for Onsite Support

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Title Page Web/SNMP Management SmartSlot Card

SNMP Web Management. User s Manual For SNMP Web Card/Box

1 For All Non-Programmable Digital Thermostat

NortechCommander Software Operating Manual MAN R6

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

User Manual. Smart-UPS. Uninterruptible Power Supply 750/1000/1500 VA. 100/120/230 Vac. Rack Mount 2U

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

Network Management Card Wizard--1. Introduction... 1 Using the Network Management Card Wizard... 5

MCR1900 Media Converter 19-Slot Chassis

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade

PX100 MBP with Configurable Distribution

PowerPanel Business Edition USER MANUAL

ExStik TM ph Waterproof Meters

BroadBand PowerShield. User Manual

McAfee Data Loss Prevention

Powerware Relay-Serial Card User s Guide

EE7016 EchoStream Survey Kit

User's Guide. Integrating Sound Level Datalogger. Model Introduction

User Manual (English)

Memcom Emergency Telephone

Quick Installation Guide TK-209K TK-409K

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

Online UPS. PowerWalker VFI 1000R/1U

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

How To Set Up An Inverter

Wireless Router Setup Manual

CABLE MODEM QUICK START

Temperature & Humidity SMS Alert Controller

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Start Here Series. All-in-One Printer. Print Copy Scan. Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Spectra T50e Flash (SD) Card Installation Instructions

User and Installation Guide

Network Management Card

HM-W536 Install Guide

Cisco TelePresence VCR MSE 8220

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

INSTALLER S & OWNER S MANUAL

User Manual. Modular Online UPS

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Tyan Computer. Transport PX22. Service Engineer s Manual

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Installation and Operation

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

NEC Express5800 Series NEC ESMPRO AlertManager User's Guide

Transcription:

Symmetra PX UPS 10-80 kw 208 V Operation and Maintenance Manual

Symmetra PX 10-80 kw, 208V Operation and Maintenance Manual

Contents IMPORTANT SAFETY INSTRUCTIONS..................... 1 SAVE THESE INSTRUCTIONS........................... 1 Symbols used in this guide............................ 1 ON, OFF & STAND-BY Switch Positions................... 2 Total Power OFF Procedure............................ 3 Introduction....................................... 4 Overview of System Components....................... 5 Weights.......................................... 6 Operation........................................ 7 Functional Schematic Dual Mains / Single Mains............ 9 Control Functions................................... 9 Control Screen.................................... 10 Status Functions................................... 11 Status screens..................................... 12 Set-up Functions................................... 13 Setup screens..................................... 14 Accessories screen.................................. 15 Logging Screen.................................... 15 Display screens.................................... 16 Diag screens...................................... 16 Help screens....................................... 7 Network Connection/APC Web Management Card......... 17 Quick Configuration................................ 18 Module and Card Replacement........................ 19 How to replace Power Modules........................ 19 How to Replace Cards............................... 20 How to replace Intelligence Modules.................... 21 How to obtain replacement modules.................... 21 Replacement Parts and Numbers....................... 22 Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01 i

Troubleshooting................................... 23 General Status..................................... 23 General Fault...................................... 25 Module failure..................................... 26 Threshold Alarm................................... 26 Bypass........................................... 27 System Start-Up (if applicable)......................... 28 Secure the UPS by Setting the Stabilizing Feet............. 28 Level the UPS (Recommended)......................... 28 Power Module Installation............................ 29 Installing......................................... 29 Securing......................................... 30 Network Cable Installation (if required).................. 31 System Start-Up Procedure........................... 32 Life Support Policy/Warranty......................... 34 Life Support Policy.................................. 34 Factory Warranty.................................. 35 ii Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This guide contains important instructions for the Symmetra PX that should be followed when handling the UPS, Battery Enclosures, and Batteries. Symbols used in this guide WARNING! Risk of Electric Shock. CAUTION! Read this information. Indicates important information. Indicates a heavy load that should not be lifted without assistance. Indicates that more information is available on this subject in a different section of this manual. Indicates that more information is available on the same subject in a different manual. Do not lift heavy loads without assistance. <40 lb 40-70 lb. 70-120 lb >120 lb Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01 1

IMPORTANT SAFETY INSTRUCTIONS WARNING! Hazardous electrically-charged parts inside the UPS are energized from the battery supply even when the AC power is disconnected. Follow Total Power Off Procedure to completely de-energize the system. CAUTION! For configurations including customer-supplied external batteries, refer to manufacturer s battery installation and maintenance instructions. ON, OFF & STAND-BY Switch Positions Indicates that a switch or current protection device is in the ON position. Indicates the OFF position for a switch or a breaker Indicates that a switch is in the STAND-BY position 2 Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01

IMPORTANT SAFETY INSTRUCTIONS Total Power OFF Procedure WARNING! Before electrical installation begins, verify that the UPS is in the Total Power Off mode by following this procedure. UPS INTELLIGE NCE MODULE INTELLIGE NCE MODULE 1? Set the System Enable Switch to the STAND-BY position. SE YN SA TB EL ME XR Communica etr Op kw a era, PX tio 20 n 0V Gu ide tions Sy Ba 10 mm sic - 40 DOC UME NT STO RAG E CAUTION! To ensure solid stability, do not pull Battery Units out beyond the Red Disconnect Line unless completely removing them from the enclosure. Battery Enclosure 1 Set the DC Disconnect on ALL Battery Enclosures in your configuration to the OFF position. BATTERY UNIT 2 Disconnect all Battery Units by removing or pulling out to Red Disconnect Line. BATTER Y UNIT 3 Set the upstream Utility Power to the OFF or LOCKED OUT position. If the UPS has dual mains supply, set both supplies to the OFF or LOCKED OUT position. Note: Follow proper lock out tag procedures. ON OFF Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide OFF 990-1430 REV01 3

Introduction After the UPS has been wired electrically, it is ready for start-up. This guide will allow you to quickly start up the UPS. It contains information on Safety, System Components, Securing the UPS, Module Installation, Network Cable Installation, Start-Up Procedure, and Basic Troubleshooting. 4 Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01

? Overview of System Components Intelligence Modules (2) Network Management Card Cable Power Module Bays PowerView Display Power Module Battery Communication Cable Bypass Static Switch Module System ID Card DOCUMENT STORAGE Symmetra PX 10-40 kw, 200 V Basic Operation Guide Documentation Storage Tray Input / Output Chassis System Power Supply System Power Supply Cards (2) System Enable Switch S Y S T E M E N A B L E XR Communication Remote Computer Display Power View Interface Display/Computer Interface Port 1 Port 2 System Power Supply Smart Slots (2) Display / Computer Interface Card Battery Comm Card Terminators Reset PSU Sub Supply Switch Gear Monitor Card PSU Sub Supply Link RXTX 10/100 10/100Base-T Status AP9617 Network Management Card Switch Gear Monitor Card Network Management Card Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01 5

? Overview of System Components Weights UPS (empty) 600 lb. (275 kg) Power Module 60 lb. (26 kg) DOCUMENT STORAGE Symmetra PX 10-40 kw, 200 V Basic Operation Guide 6 Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01

Operation The PowerView is the user control interface used to configure the functionality, monitor the system, set alarm thresholds, and to provide audible and visual alarms. Four LED indicators report the operational status of the UPS. Liquid crystal display (LCD) Five navigation keys are used to select and open menu items, to access information, change system parameters, and to launch contextsensitive help. LOAD ON ON BATT BYPASS Chrg 100% Load 000% 120Vin 000Vout 60Hz Runtime: 00hr 30m ESC? 9 FAULT 1 2 3 4 5 6 7 8 1 2 3 4 LOAD ON LED ON BATT LED BYPASS LED FAULT LED When green, the Symmetra PX UPS is providing power to the load equipment. When yellow, power is flowing from the batteries to the Power Modules. When yellow, power to the load is being supplied through the Static Bypass Switch. When red, an fault condition exists. 5 LCD Displays alarms, status data, instructional help, and configuration items. 6 7 UP and DOWN navigation keys ENTER key Selects menu items and accesses information. Opens menu items and input changes to system parameters. 8 9 HELP key ESC key Launches context-sensitive help. Returns to previous screen displayed. Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01 7

Operation Press ESC ESC system status information. until you get to the Top-Level Status Screen, which provides you with basic Chrg 100% Load 000% 120Vin 000Vout 60Hz Runtime: 0hr 0m Top-Level Status Screen (factory default) Press Enter to open the Top-Level Menu screen. This screen is the launching pad to command, configure, and monitor the system. Selector Arrow Control Status Setup Accessories Logging Display Diags Help Top-Level Menu Press Up and Down to navigate the selector arrow and view all sub-menu screens. Bat Voltage: 218V Bat Capacity 100.0% Runtime: 01hr 30min 32 Batts, 00Bad Battery Module Status Screen Capacity: 80.0kVA Fault Tolerance: n+1 Total UPS Modules: 9 Bad UPS Modules: 00 Power Module Status Screen Scroll arrows indicate additional screens Press Up, Down and Enter to move input arrow to select and enter information. Low Batt Dur: Shutdwn Dly: Return Dly: Return Bat Cap: 2min 20sec 0sec Low Batt Dur: Shutdwn Dly: Return Dly: 0% Return Bat Cap: Shutdown Menu 10min 20sec 0sec 0% Shutdown Menu Input arrows indicate changeable options 8 Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01

Operation Functional Schematic Dual Mains / Single Mains Only present in single mains installations. Bypass Input Mains Input Bypass Static Switch Module Power Module Load Control Functions Turn load on/off: 1 Graceful Turn Off Start Runtime Cal Turn Load On 2 UPS LOAD IS OFF Control Sub-Menu Load Off Screen Turn into/out of bypass: 1 UPS into Bypass Do Self Test Simulate Power Fail Graceful Reboot Control Menu 2 UPS IS BYPASSED Bypassed Screen Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01 9

Operation Control Screen From the Control screen, you can select the following items: UPS into Bypass Do Self Test Simulate Power Fail Graceful Reboot Graceful Turn Off Start Runtime Cal Turn Load On/Off Place into or return from maintenance bypass operation Initiate a system of self-tests and diagnostics. Simulate a power failure Turn off and start load equipment in an ordinary manner. Shut down load equipment in an orderly manner. Begin runtime calibration of the UPS. Apply power to or shut down the Symmetra PX UPS 10 Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01

Operation Status Functions Verify general module status: Control Logging Capacity: 80.0kVA 1 Status Display 2 Fault Tolerance: n+1 Setup Diags Total Pwr Modules: 9 Accessories Help Bad Pwr Modules: 0 Top-Level Menu Sub-Sub-Sub-Sub-Sub Status Screen Verify voltage on all phases: 1 Control Status Setup Accessories Logging Display Diags Help 2 0 Vin Vbyp Vout 1 119.6 119.2 0.0 2 119.4 119.4 0.0 3 119.6 119.3 0.0 Top-Level Menu Status Screen Verify battery voltage/capacity: 1 2 Control Logging Status Display Setup Diags Accessories Help Top-Level Menu Bat Voltage: 218.6V Bat Capacity: 100.0% Runtime: 1hr 30min 32 Batts, 0 Bad Sub-Sub-Sub-Sub Status Screen Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01 11

Operation Status screens The status screen display information regarding load, battery, power module voltage, and current. Status Screen 1. Vin Vout Iout The input voltage (V), output voltage (V), and output current (A) for each phase (1-3). Status Screen 2. %load assuming no redundancy Percentage of the load in relation to the total capacity of all power modules. Status Screen 3. %load allowing for n+ redundancy Percentage of the load, allowing for the redundancy in your system. Status Screen 4. Frequencies The input and output frequency in hertz (Hz). Status Screen 5. Batt Voltage Batt Capacity Runtime #Batts #Bad Actual voltage of the DC bus (volts). Percentage of battery capacity available The available runtime for battery operation in hours and minutes The number of installed battery modules. The number of failed battery modules. 12 Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01

Operation Status Screen 6. Capacity: kva Fault Tolerance Total Pwr Modules Bad Pwr Modules The system load capacity. The configured redundancy for your UPS (n+0, n+1, n+2...). The number of power modules installed The number of failed power modules installed Status Screen 7. Alarm Thresholds Fault Tolerance n+0 Runtime hr min load: kva Settings configured for the thresholds that trigger alarms. The alarm threshold for reduced redundancy. The alarm threshold for reduced runtime. Alarm indication of the load exceeding the configured redundancy Status Screen 8. Self Test Lst Xfr Status IM RIM Status of the last self-test Information on the last transfer to battery operation. General UPS status. Status of the main intelligence module. Status of the redundant intelligence module. Set-up Functions Display parameters are set to factory defaults. Changing factory default settings: Control Logging 1 Status Display 2 Setup Accessories Diags Help Top-Level Menu Settings: Shutdown Defaults Output Freq Settings Menu Alarms Bypass Copy Other Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01 13

Operation Setup screens From the Setup screen, you can select the following items: Shutdown Configure the following system shutdown conditions: Low Batt Dur: Low battery duration is the time from low battery signal to the shutdown of the load. This signal is sent to the server using shutdown software (PC + PCNS). Shutdwn Dly: Shutdown delay is the time from when the UPS receives a shutdown command (usually sent by a server) to the shutdown of UPS power to the load equipment. This delay allows load equipment time to finish shutdown processes. Return Dly: Return delay is the amount of time the UPS wants to turn on after a power outage has ended. Defaults Output Frequency Alarms Return Bat Cap: Return battery capacity is the minimum percentage of battery capacity required for the UPS to turn the load on. Return all UPS settings to their default values. Set the desired output frequency Redundancy: The state of redundancy that will trigger an alarm. Choices are: N+0 an alarm will occur only when there is more load than all functioning power modules can support; N+1 an alarm will occur when there are no spare power modules in good condition; N+2 an alarm will occur when there is only one functioning power module. Load: When the load is greater than this threshold, an alarm will sound. Bypass Copy Other Runtime: When the time the UPS can power the load is less than this threshold, an alarm will sound. This alarm is the result of an increase in load or a decrease in battery capacity. Set the conditions in which the UPS will automatically go into bypass operation. Copy the UPS settings. Self Test: Set the UPS to perform a self-test automatically at periodic intervals. USP ID: Provide a unique name for the UPS. Vout Reporting: Set the reporting to the number of the tap to which the most significant load is wired on the output transformer. Output: Set the UPS output voltage. BatFrAmpHour: Set the Ampere-Hour rating of external battery enclosures that are not APC Symmetra PX Battery Enclosures. 14 Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01

Operation Accessories screen Control Status Setup Accessories Top-Level Menu Logging Display Diags Help From the Accessories screen, you can view the status of APC accessories connected to the UPS. Logging Screen Control Status Setup Accessories Top-Level Menu Logging Display Diags Help The Logging screen allows you to customize the UPS log. The following items are accessible from this screen: View Log View Statistics Configure Logging List Event Groups Point to an entry in the log and press the Enter key to view a description of the event. The display logs the most recent 64 events. View statistics of the events logged. Set the type of events that are recorded in the log. To log a type of event, choose On. View the list of event types. Power Events UPS Control Events User Activities UPS Fault Events Measure UPS Events For each group, press the Enter key to display each event listed under the group. Clear Log Clear all events currently stored in the log. Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01 15

Operation Display screens Control Status Setup Accessories Top-Level Menu Logging Display Diags Help The Display screens allow you to customize the UPS display interface. The following items are accessible from this screen: Date: Password Information Beeper Contrast Config Set the correct date (day:month:year) and time (hour:minute). Protect the password against unauthorized configuration changes. View the model number, serial number, date of manufacture, and revision number of the display interface. Configure the audible alarm interface.: At UPS At Disp Vol Click Set the contrast on the LCD. Personalize the Top-Level Status screen. Choose each line you want displayed from a list of options. To change a line, move the selection arrow to the line you want to change and press the ENTER key. Scroll up or down the list to find the data you want displayed and press the ENTER key to save you changes. Press the ESC key to discard your changes. Diag screens Control Status Setup Accessories Top-Level Menu Logging Display Diags Help The Diagnostic screens provide information for use in troubleshooting. The following items are accessible from this screen: 16 Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01

Display Display/Computer Interface XR Communication Port 1 Reset Link-RX/TX 10/100 10/100Base-T Status AP9617 Network Management Card Operation Fault & Diagnostics Lists any failures found. If any status except ON or OK is displayed, a module or card must be replaced. The Faults and diagnostics screen will describe the location of the failed module/ card. If you do not have a redundant intelligence module installed, you must place the UPS in bypass operation before you remove an intelligence module. Lists external device status. If any status except ON or OK is displayed, a module, card or battery must be replaced. If you do not have a redundant intelligence module installed, you must place the UPS in bypass operation before you remove an intelligence module. Help screens To access the display interface context-sensitive help screens, press the? key. Network Connection/APC Web Management Card Computer Interface Remote Computer Power View Interface 10/100Base-T Reset Link-RX/TX 10/100 Status AP9617 Network Management Card Serial port DOCUMENT STORAGE Symmetra PX 10-40 kw, 200 V Basic Operation Guide 20-foot Network Cable supplied with the UPS. Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01 17

Operation Quick Configuration Disregard the procedures in this section if you have an APC InfrastruXure Manager as part of your system. See the InfraStruXure Manager s documentation for more information. You must configure three TCP/IP settings before the Management Card can operate on a network: IP address Subnet mask Default Gateway From the PowerView Display: 1 Control Status Setup Accessories Logging Display Diags Help 2 Web/SNMP Mngmnt Card Network Setup View Network Setup Top-Level Menu Accessories Menu 3 IP>>159.215.086.082 Mask>>255.255.255.000 Gway>>159.215.086.001 Accept changes 4 IP>>159.215.086 Mask>>255.255.255.000 Gway>>159.215.086.001 Accept changes Network Set-up Screen Network Set-up Screen If a Default Gateway is unavailable, use the IP address of a computer located on the same subnet as the Management Card that is usually running. The Management Card uses the Default Gateway to test the network when traffic is very light. See Watchdog Features in the Introduction of the Network Management Card User s Guide CD (.\doc\usrguide.pdf) for more information about the watchdog role of the Default Gateway. The Management Card User s Guide CD is located in the documentation storage tray. 18 Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01

? XR Communications Module and Card Replacement WARNING! Only trained persons familiar with the construction and operation of the equipment and the electrical and mechanical hazards involved, may install and remove system components. How to replace Power Modules 1 INTELLIGENCE MODULE INTELLIGENCE MODULE To de-activate the module, turn Locking Latch (with arrow pointing towards the module) counterclockwise until it points downwards. DOCUMENT STORAGE Symmetra PX 10-40 kw, 200 V Basic Operation Guide Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01 19

Module and Card Replacement Pull out the module. Display shows message saying it has decreased the number of power modules. Reverse procedures for installation. 2 Unscrew springactivated knobs on both sides of the module until they pop out. Standing on either side of the UPS, 2 people can now pull the module almost free of the UPS (the lock mechanism prevents the module from being pulled clear of the UPS). With the module still resting in the UPS, release the lock by pushing the black plastic tab on either side of the module 3 INTELLIG ENCE MODULE INTELLIG ENCE MODULE 2? Sy Ba 10 m sic - 40metr Op kw a er, PX at 20 ion 0 GuV id e XR Commun ications DOCU MENT STO RAGE Power Module will not start unless Locking Latch is engaged. How to Replace Cards System Power Supply Display Remote PowerView Display / Computer Display Disp lay / Interface Rem ote PowerVi ew Port Por t Port mun icatio System 2 Power Supply 1 Por t XR Com 1 XR Communication Com pute Interfacer Com pute r Inte rface 2 n Reset Sub Link- RX/T 10/10X 0 Supply AP961 7 Net work 10/10 0Base -T Manag Statu Sy m Ba 10 m sic - 40 etra O kw pe PX ra, 20 tio 0 n V G ui de PSU DOCU MENT STOR AGE s ement Car d Switch Gear Monitor Card System Loosen the 2 Phillips screws at both sides of the card. Carefully pull out the card. Reverse procedures for installation. Display shows message saying it has registered the new card. 20 Power Supply Display Disp Rem ote PowerVi ew System lay / Com pute r Inte Port mun PSU icatio Power Supply rface 1 Port XR Com 2 n Sub Supply Switch Gear Monitor Card Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01

Module and Card Replacement How to replace Intelligence Modules One intelligence module can be replaced without interrupting power to the connected equipment provided another functioning intelligence module is installed. Loosen the 2 Phillips screws at both sides of the module (top of module). As soon as the left side screw is loose, the module will be deactivated. Display shows message saying it has decreased the number of cards. Reverse procedures for installation. INTELLIGENCE MODULE INTELLIGENCE MODULE INTELLIGENCE MODULE INTELLIGENCE MODULE How to obtain replacement modules To obtain a replacement module, contact APC Customer Support at 1 (800) 800 4272. 1. In the event of a module failure, the display interface may display additional fault list screens. Press any key to scroll through these fault lists, record the information, and relay it to the representative. 2. If possible, call APC Customer Support from a telephone that is within reach of the Symmetra PX UPS display interface so that you can gather and report additional information to the representative. 3. Be prepared to provide a detailed description of the problem. A representative will help you solve the problem over the telephone, if possible, or will give you a return material authorization (RMA) number. If a module is returned to APC, this RMA number must be clearly printed on the outside of the package. 4. If the Symmetra PX UPS is within the warranty period, repairs will be performed free of charge. If it is not within the warranty period, there will be a charge for repair. Review APC s warranty policy. Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01 21

Module and Card Replacement See section on Warranty for more information 5. If the Symmetra PX UPS is covered by an APC service contract, have that information available and give ti to the representative. Replacement Parts and Numbers Part 80kW Enclosure Only 10kW Power Module Intelligence Module Symmetra 3-Phase 80 kva Bypass Static Switch Module System Power Supply Card PSU Supply Board Display and Computer Interface Card Switch Gear Monitoring Card System ID Card Battery Communication Card Web Card, SNMP Battery Enclosure only No SYCF80KF SYPM10KF SYMIM4 SYSW80KF SYCSPS SYCSS SYCDCI SYCSGMON SYCSYSID SYCXRCOM AP9617 Web/ Management Slot Card SYCF8BF WARNING! Only trained persons familiar with the construction and operation of the equipment, and the electrical and mechanical hazards involved, may install and remove system components. 22 Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01

Troubleshooting This section lists all of the alarm and status messages that are displayed on the UPS display interface. A suggested corrective action is listed with each message to help you troubleshoot problems. If a problem is reported, ensure that the system component in question is correctly installed (refer to section on Modular & Card Replacement. General Status Display Message Meaning Corrective Action Input Freq outside configured range AC adequate for UPS but not for bypass Low/No AC input, startup on battery Intelligence Module inserted Intelligence Module removed Redundant Intelligence Module inserted Redundant Intelligence Module removed The input frequency to the UPS is outside the configured range. The output frequency will not synchronize with the input frequency. Normal bypass is not available. The Symmetra PX UPS will function online with the input voltage, but in the event that bypass is required, the input voltage is not adequate to power the load equipment. Input voltage is not adequate to start the Symmetra PX UPS. If start-up proceeds, the Symmetra PX UPS will function in battery operation. An Intelligence Module has been installed into the Symmetra PX UPS. An Intelligence Module has been removed from the Symmetra PX UPS. An intelligence Module has been installed into the Symmetra PX UPS. An Intelligence Module has been removed from the Symmetra PX UPS. Option 1: Improve the frequency of the incoming voltage. Option 2: Widen range of acceptable incoming frequency using the display interface. Select Start-UP, Setup, OUtput, Freq Select). Option 3: Proceed with startup. Normal bypass is not available. Option #1: Improve the incoming voltage. Option #2: Proceed with startup. Normal bypass is not available. Option 1: Cancel start-up until acceptable input voltage is present. No corrective action necessary. Check that the intelligence modules are properly inserted and that the fastening screw is tight. No corrective action necessary. Check that the intelligence modules are properly inserted and that the fastening screw is tight. Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01 23

Troubleshooting Display Message Meaning Corrective Action # of batteries changed since last ON # of Pwr modules changed since last ON At least one battery module has been added or removed from the UPS since the last time the Power ON command was used. At least one battery module has been added or removed from the UPS since the last time the Pwr ON command was used. Check that all battery units are installed correctly. Check that all power modules are properly inserted, the two fastening screws are tight, and the locking latch is engaged. # of batteries increased At least on battery module has been added to the system. # of batteries decreased At least one battery module has been removed from the system. No corrective action necessary. Ensure that all battery units are properly inserted. # of Pwr Modules increased # of Pwr Modules decreased # of External Battery Cabinets increased # of External Battery 0Cabinets decreased Redundancy Restored At least one power module has been added to the system At least one power module has been removed from the system. At least one external battery cabinet has been connected to the Symmetra PX UPS At least one external battery cabinet has been disconnected from the Symmetra PX UPS A loss of power module redundancy occurred and the redundancy has been restored. Either additional modules have been installed or the load has been reduced. No corrective action necessary. Check that all power modules are properly inserted, the two fastening screws are tight, and the locking latch is engaged. No corrective action necessary. Ensure that all Battery Enclosure s communication cables are properly connected and that the LEDs are illuminated on the Battery communication cards. No corrective action necessary. 24 Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01

Troubleshooting General Fault Display Message Meaning Corrective Action Need Bat Replacement The Redundant Intelligence Module is in control UPS Fault On Battery Shutdown or unable to transfer to batt due to overload Load Shutdown from Bypass. Input Freq/Volts outside limits Fault, Battery Charger Failure One or more battery modules are in need of replacement The Main Intelligence Module has failed, and the redundant intelligence module is functioning as the primary intelligence module. A fault has occurred in a power module. This will always occur with a power module failure message. The Symmetra PX UPS has transferred to battery operation due to the input going out of acceptable range. At this time the batteries will discharge until the input is restored to an acceptable range. The Symmetra PX UPS has shut down because an overload occurred and bypass is not available. The Symmetra PX UPS has transferred to battery operation because the input is out of acceptable range. The battery charger in one or more of the power modules failed Refer to Module Replacement Section for procedures. Replace the Main Intelligence Module.Refer to Module Replacement Section for procedures. Contact APC Technical Support at (1) (800) 800-4272. No corrective action necessary. Note: Runtime is limited in duration. Prepare to shut down the Symmetra PX UPS and the load equipment or restore incoming voltage. Option 1: Reduce the load to eliminate overload. Option 2: If possible, add power modules to eliminate overload. Option 3: Replace failed power modules to eliminate overload. Correct the input voltage problem. Refer to Module Replacement Section for procedures. Fault, Internal Temp exceeded normal limits Input circuit breaker tripped open The temperature of one or more battery units has exceeded system specifications. The input circuit breaker on the Symmetra PX UPS is open. Input voltage is disconnected to the Symmetra PX UPS. Ensure that the ambient temperature meets the specifications of the system. Option 1: If this occurs with an overload condition, decrease the load and reset the breaker. Option 2: If no overload condition exists, reset the breaker. If it trips open again, contact APC Technical Support at (1) (800) 800-4272. System level fan failed A cooling fan in the Symmetra PX UPS failed. Contact APC Technical Support at (1) (800) 800-4272. Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01 25

Troubleshooting Module failure Display Message Meaning Corrective Action Bad Battery Module A battery module has failed and requires replacement. Refer to Module Replacement Section for procedures. Bad Power Module A power module has failed and requires replacement. Refer to Module Replacement Section for procedures. Intelligence Module is installed and failed The Main Intelligence Module has failed and requires replacement. Replace the Main Intelligence Module. Refer to Module Replacement Section for procedures. Redundant Intelligence Module is installed and failed The Redundant Intelligence Module has failed and requires replacement. Replace the Redundant Intelligence Module. Refer to Module Replacement Section for procedures. Threshold Alarm Display Message Meaning Corrective Action Redundancy has been lost The Symmetra no longer detects redundant power modules. Either power module(s) have failed, or the load has increased. Option 1: If possible, install additional power modules. Option 2: Replace failed modules. Refer to Module Replacement Section for procedures. Runtime is below alarm threshold Actual power module redundancy has fallen below user-specified redundancy alarm threshold. Either power module(s) failed or the load increased. Option 1: If possible, install additional power modules. Option 2: Replace failed modules. Refer to Module Replacement Section for procedures. Option 3: Decrease load or reconfigure threshold. Runtime is below alarm threshold The predicted runtime is lower than the user-specified minimum runtime alarm threshold. Either the battery capacity has decreased, or the load has increased Option 1: Allow the battery modules to recharge. Option 2: If possible, increase the number of battery modules. Option 3: Reduce load or reconfigure threshold. Load is above kw alarm threshold The load has exceeded the user specified load alarm threshold Reduce load or re-configure threshold. 26 Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01

Troubleshooting Display Message Meaning Corrective Action Load is No Longer above Alarm Threshold Min Runtime Restored The load exceeded the load alarm threshold and the situation has been corrected either because the load decreased or the threshold was increased. The system runtime dropped below the configured minimum and has been restored. Additional battery modules were installed, the existing battery modules were recharged, the load was reduced, or the threshold was raised. No corrective action necessary No corrective action necessary Bypass Display Message Meaning Corrective Action Bypass is not in range (either freq or voltage) Backfeed contactor stuck in OFF position Backfeed contactor stuck in ON position UPS in bypass due to internal fault UPS in bypass due to overload System is in Maintenance bypass Fault, Bypass Relay Malfunction The frequency and/or voltage is out of acceptable range for bypass. This message occurs when the Symmetra is online, and indicates that the bypass mode may not be available if required. The Symmetra PX UPS is stuck in the bypass position and cannot go online. The Symmetra PX UPS is stuck in the on-line position and cannot go to bypass. The Symmetra PX UPS has transferred to bypass mode because a fault has occurred The load exceeded the system power capacity. The Symmetra PX UPS has switched to bypass mode The Symmetra PX UPS is in bypass because it has been commanded into bypass or due to an internal fault. The bypass relay has malfunctioned. Option 1: Correct the input voltage to provide acceptable voltage and/or frequency. Option 2: Decrease the sensitivity to input frequency. (Select Startup, Setup, OutputFreq, and select a value). Contact APC Technical Support. at (1) (800) 800-4272. Contact APC Technical Support. at (1) (800) 800-4272. Contact APC Technical Support. at (1) (800) 800-4272. Option 1: Decrease the load. Option 2: If possible, add a power module to the system. No corrective action necessary. If other alarms exist, troubleshoot base on other alarms. Contact APC Technical Support. at (1) (800) 800-4272. If the system works in bypass, ensure the presence of AC mains supply input. If a problem persists, note UPS model #, serial #, and date purchased before calling Tech Support at: 1 (800) 800 4272. Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01 27

System Start-Up (if applicable) System start-up is included with your system. If you have to move your system to a new location and need a new start-up, remove all power modules and follow the Total Power Off Procedure. Raise the stabilizing feet. Secure the UPS by Setting the Stabilizing Feet After the electrical wiring has been completed, secure the UPS in its final operating position. Use a 13/14-mm wrench (shipped with UPS) to adjust all 4 stabilizing feet until pads make solid contact with the floor. Level the UPS (Recommended) Adjust stabilizing feet to level from front to back and left to right. 13/14-mm wrench CAUTION! Do not move the UPS after the stabilizing feet have been lowered, or equipment damage may occur. 28 Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01

? System Start-Up (if applicable) Power Module Installation WARNING! Only APC-trained personnel familiar with the construction and operation of the equipment, and the electrical and mechanical hazards involved, may install and remove system components. CAUTION! Before installing any modules in the UPS, ensure that the System Enable Switch is left in the STAND-BY position (if not, see section on Total Power Off. At least 1 Battery Module (4 Battery Units) is required in the battery enclosure and the DC breaker to be on to start up the system. If using value line battery cabinets, battery configuration will need to be entered manually through display, Installing 9th 8th 7th 6th 5th 4th 3rd 2nd 1st Starting from the lowest available bay, remove as many blind plates as the number of Power Modules to be installed. Install Power Modules and push completely into the UPS. DOCUMENT STORAGE Symmetra PX 10-40 kw, 200 V Basic Operation Guide Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01 29

? System Start-Up (if applicable) Securing 1 2 Fasten screws using a screwdriver. Engage Locking Latch. Turn knob on right side of UPS clockwise until arrow faces module. DOCUMENT STORAGE Symmetra PX 10-40 kw, 200 V Basic Operation Guide 3 Make sure that the Locking Latch on Bypass Static Switch Module is engaged. The Power Module will not start unless the Locking Latch is engaged. After the installation and securing of the Power Modules, make sure that the locking latch on the Bypass Static Switch Module is engaged 30 Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01

? Network Cable Installation (if required) Use 20-ft. standard Cat 5 Data cable (supplied). WARNING! Ensure Total Power Off before removing side panel 3 Unlock right-side panel using key Depress latches 4 INTELLIGENCE MODULE INTELLIGENCE MODULE Pull out panel 5 Remove left terminator from Port I. Save for reinstallation in Battery Enclosure. Install Battery Communication Cable in Port I. Connect Battery Comm Cable to port 2. 1 Display Display / Computer Interface XR Communications Remote Power View Port 1 Port 2 Computer Interface Reset Switch Gear Monitor Card DOCUMENT STORAGE Symmetra PX 10-40 kw, 200 V Basic Operation Guide Link-RX/TX 10/100 10/100Base-T Status AP9617 Network Management 2 Connect Network Comm Cable to Network Port as required Lift panel off UPS 6 Route cables through front holes of UPS. Exit UPS from bottom or top as required If your UPS has been installed in-between devices and side panels cannot be removed the Bypass Static Switch Module can be removed to gain access. Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01 31

System Start-Up Procedure 1 Utility Power ON 2 Battery Enclosure Switch ON 2 System Enable Switch ON ON S Y S T E M E N A B L E OFF Wait approximately 30 seconds for system to boot up. Display will show a fault if Power Module Locking Latch is not engaged. Press ESC status information until you get to the Top-Level Status Screen, which provides you with basic system LOAD ON ON BATT BYPASS FAULT Chrg 100% Load 000% 120Vin 000Vout 60Hz Runtime: 00hr 30m Top-Level Status Screen ESC? Press Enter to open the Top-Level Menu screen. This screen is the launching pad to command, configure, and monitor the system. Control Status Setup Accessories Top-Level Menu Logging Display Diags Help 32 Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01

System Start-Up Procedure Press the down key and then the enter key to select Status. Verify that all power, battery and intelligence modules are detected by the system and are functioning correctly by scrolling down and reviewing all status screens. Please note that the intelligence modules are monitored under the Miscellaneous Status Screen (submenu under Status). Bat Voltage: 218V Bat Capacity 100.0% Runtime: 01hr 30min 32 Batts, 00Bad Typical Status Screen If a problem is reported, ensure that the system component in question is correctly installed. If the problem persists, refer to Basic Troubleshooting. From the Control Menu, choose Turn Load On. Load On LED should now be lit. Turn Load On Do Self Test Simulate Power Fail Graceful Reboot Control Menu Screen LOAD ON ON BATT UPS Load is ON. BYPASS FAULT Confirm Menu Screen The UPS is now ready to support the load equipment. For further operation, PowerView features, and configuration, see Basic Operation Guide and Product Manual CD (shipped with unit) and visit our website: www.apc.com. If you are using a network connection, please refer to the enclosed Product Manual CD. Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01 33

Life Support Policy/Warranty Life Support Policy American Power Conversion Corporation, its affiliates and subsidiaries world-wide, ( APC ) do not recommend the use of any of their products in life support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness. APC does not permit the use of any of its products in direct patient care. APC will not knowingly sell its products for use in such applications unless the life support system or direct patient care device is part of a whole facility/building into which the UPS is integrated and unless APC receives in writing assurances satisfactory to APC that: (a) the UPS system will be configured in a manner that will provide N+1 power redundancy to the critical load (b) the end-user assumes all risks and signs the APC System Configurations and Use Form, and (c) the customer and operators of the APC UPS system agree to idemnify and hold APC and its affiliates and subsidiaries harmless for any and all claims arising out of the systems use in such applications. Examples of devices considered to be life support devices include, but are not limited to, neonatal oxygen analysers, nerve stimulators (whether used for anaesthesia, pain relief, or other purposes), autotransfusion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators for both adults and infants, anaesthesia ventilators, infusion pumps, and any other device designated as critical by the U.S.F.D.A. Hospital grade wiring devices and leakage current may be ordered as options on many APC UPS systems. APC does not claim that units with this modification are certified or listed as Hospital Grade by APC or any other organization. Therefore these units do not meet the requirements for use in direct patient care. 34 Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01

Life Support Policy/Warranty Factory Warranty APC warrants that the unit, when properly installed and commissioned by APC or APC authorized service personnel, shall be free from defects in materials and workmanship for a period of (1) year from the date of installation or maximum 18 months after manufacturing. In the event that the unit fails to meet the foregoing warranty, APC shall for a period of one (1) year repair or replace any defective parts, without charge for on-site labor and travel if trained & authorized APC personnel has conducted start-up of the unit. An APC Start-Up Service must be performed/completed by APC or by service personnel authorized by APC. If not, the on-site factory warranty will be voided and replacement of defective parts only will be covered. APC shall have no liability and no obligation to repair the installed unit if nonauthorized APC personnel performed the start-up and such start-up caused the unit to be defective. APC SHALL NOT BE LIABLE UNDER THE WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY PURCHASER S OR ANY THIRD PERSON S MISUSE, NEGLIGENCE, IMPROPER INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR OR MODIFY, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, LIGHTNING OR OTHER HAZARD. THERE ARE NO WARRANTIES, EXPRESSED OR IMPLIED, BY OPERATION OF LAW OR OTHERWISE, OF PRODUCTS SOLD, SERVICED OR FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION HEREWITHIN. APC DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY, SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE. APC S EXPRESS WARRANTIES WILL NOT BE ENLARGED, DIMINISHED, OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF, APC S RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES. THE WARRANTIES SET FORTH ABOVE, CONSTITUTE APC S SOLE LIABILITY AND PURCHASER S EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES. APC S WARRANTIES RUN ONLY TO PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES. IN NO EVENT SHALL APC, ITS OFFICERS, DIRECTORS, AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, ARISING OUT OF THE USE, SERVICE OR INSTALLATION, OF THE PRODUCTS, WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT, IRRESPECTIVE OF FAULT, NEGLIGENCE OR STRICT LIABILITY OR WHETHER APC HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES. Symmetra PX 10-80 kw, 208V Operation & Maintenance Guide 990-1430 REV01 35

APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: Visit the APC Web site to find answers to frequently asked questions (FAQs), to access documents in the APC Knowledge Base, and to submit customer support requests. www.apc.com (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. www.apc.com/support/ Global support with FAQs, knowledge base, and e-support. Contact an APC Customer Support center by telephone or e-mail. Regional centers: APC headquarters U.S., Canada Latin America Europe, Middle East, Africa (1) (800) 800-4272 (toll free) (1) (401) 789-5735 (USA) (353) (91) 702020 (Ireland) Japan (0) 3 5434-2021 Local, country-specific centers: go to www.apc.com/support/contact for contact information. Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support. Entire contents copyright 2003 American Power Conversion. All rights reserved. Reproduction in whole or in part without permission is prohibited. APC, the APC logo, Symmetra, and InfraStruXure are trademarks of American Power Conversion Corporation and may be registered in some jurisdictions. All other trademarks, product names, and corporate names are the property of their respective owners and are used for informational purposes only. 990-1430 05/2003