How To Set Up An Inverter



Similar documents
MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Setting Up the ZigBee Ethernet Gateway

One. Invest with confidence Smart Solar Inverter Solutions. solarinvertersolutions.com. Residential, commercial and large scale applications

Disclaimers. Important Notice

PCS300 Universal IP Reporting Module V1.0

Danfoss Link Mobile Phone Butler

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Quick Start Guide. RV0xx Series Routers

GSMPBX version 1.3 Datasheet

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK

Quick Start Guide. RV 120W Wireless-N VPN Firewall. Cisco Small Business

HP UPS R1500 Generation 3

Memcom Emergency Telephone

Energy Communication Unit (ECU)

Installation and setup guide V 1.0

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

INSTALLATION GUIDE 1

GPS Vehicle and personal location tracker. User manual

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

HP SATA/SAS hard drive and Solid State Drive installation

Huawei E169 & E220 Status Lights

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

SMS Alarm. User Manual

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

Solar monitoring gateway quick start guide

Setting up the local FTP server

Technical Manual. (TLT-2H GPS/GSM Vehicle Tracker) V1.5

Chapter 1 Connecting the Router to the Internet

Ⅱ Function Characteristics

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

N600 WiFi USB Adapter

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

User Manual. Genius GPS / GSM 810 Real Time GPS Tracker. Android App Download. Iphone App Download ENGLISH. Genius Advanced Technologies

BEC 6200WZL. 4G/LTE Cellular Broadband Router. Quick Start Guide

SITRANS RD500 Configuring the RD500 with PSTN or GSM modems and Windows-based servers and clients for communication Objective:

Energy Communication Unit (ECU)

English version. LW320/LW321 Sweex Wireless 300N Router. Package Contents. Terminology list

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

How to Set Up Your NSM4000 Appliance

Disclaimers. Important Notice

CCTR-800 Portable Real Time GPS Tracker

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

94220E FLEXIT CS1000. Installation instructions and user guide. Web operation. ACX52.22 WEB and OPC ART.NO: 55576

USER S MANUAL. Settop Cell-Xtrem

Sunny Boy Accessories SMA POWER BALANCER

Communication Setup Application Note

Technical Notes TN 1 - ETG FactoryCast Gateway TSX ETG 3021 / 3022 modules. How to Setup a GPRS Connection?

Ericsson W25. Mobile Networks. Quick Installation Guide

Acellus Lab Cart. User s Manual. Version 4B. Acellus Corporation Copyright 2010 Acellus Corporation. All Rights Reserved.

Adding or replacing a mesh node in an existing mesh network

Vehicle Monitoring Quick Reference Guide

SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0

Talk2M ewon Internet Connection How To

June 2013 v. 0.2

ON-GUARD. Guard Management System. Table of contents : Introduction Page 2. Programming Guide Page 5. Frequently asked questions Page

User Manual WatchPower

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Getting started with

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Quick DDNS Quick Start Guide

TelNet Digital Fax. Reference Guide..

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Teltonika FM41XX. Configurator v. 1.0

Configuring security in ION devices using ION Setup

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

User s Manual. Management Software for Inverter

Network Interface Panel User s Guide NPD EN

User Manual of Omnik Internal Data Collector

Pandora FMS 3.0 Quick User's Guide: Network Monitoring. Pandora FMS 3.0 Quick User's Guide

M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007

CPEi 800/825 Series. User Manual. * Please see the Introduction Section

Installation Instructions for FT-10 Network PowerCommand ATS Communication Module (NCM) Kits and

HP R12000 and R18000 DirectFlow UPS User Guide

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

Wireless Router Setup Manual

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

Installation & Configuration Manuel. Socket Server. OpenAT application

SNMP Web Management. User s Manual For SNMP Web Card/Box

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

Installation Guide (No Router)

MAKING MODERN LIVING POSSIBLE TLX. User Manual. Three-phase 6k, 8k, 10k, 12.5k and 15k SOLAR INVERTERS

HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

Configuration Manual

telstra.com/ppmbb visit a telstra store or partner GETTING TO KNOW YOUR

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.

Link Gate SIP. (Firmware version 1.20)

Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions

PTPhoneManager II. User guide

NETCOMM LIBERTY SERIES. 3G WiFi Router. Quick Start Guide

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

NeoMail Guide. Neotel (Pty) Ltd

Wash Select II to WashPay Integration Field Retrofit Installation Guide

Installation Guide Solar Connect-11

BlackBerry Mobile Voice System. Version: 5.3. Administration Guide

Vantage Pro2 Temperature/Humidity Sensor Replacement Kit

Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation

Transcription:

MAKING MODERN LIVING POSSIBLE SOLAR INVERTERS Installation Guide GSM Option Kit FLX series www.danfoss.com/solar

Safety Safety Safety Message Types WARNING Safety information important for human safety. Warning is used for indicating potentially hazardous situations that can cause serious injury or death. CAUTION Caution with symbol is used for indicating potentially hazardous situations that can cause minor or moderate injuries. CAUTION Caution without symbol is used for indicating situations that may result in equipment or property damage. WARNING Disconnecting the inverter Before starting work on the inverter, switch off AC at the mains switch and PV using the PV load switch. Ensure that the device cannot be unintentionally reconnected. Use a voltage tester to ensure that the unit is disconnected and voltage free. The inverter can still be charged with very high voltage at hazardous levels even when it is disconnected from AC grid and solar modules. Wait at least 8 minutes following disconnection from grid and PV panels before proceeding. For safe disconnection of DC current, turn off the PV load switch (1). 160AA001.10 NOTE Note is used for indicating highlighted information that should be regarded with attention. General Safety All persons installing and servicing inverters must be: Trained and experienced in general safety rules for work on electrical equipment Familiar with local requirements, rules and regulations for the installation NOTE Before installation Check for damage to equipment and packaging. If in doubt, contact the supplier before commencing installation. CAUTION Installation For optimum safety, follow the steps described in this document. Keep in mind that the inverter has two voltage carrying sides; the PV input and the AC grid. 1 CAUTION Maintenance and modification Only authorised personnel are permitted to modify the inverter. To ensure personal safety, use only original spare parts available from the supplier. If non-original spare parts are used, compliance with CE guidelines in respect of electrical safety, EMC and machine safety is not guaranteed. The temperature of the cooling racks and components inside the inverter can exceed 70ºC. Observe the danger of burn injury. DC voltages up to 1000 V are present in a PV system even when the inverter is disconnected from the AC grid. Faults or inappropriate use may lead to electric arcing. L00410627-02_02

Safety L00410627-02_02

Contents Contents 1 Installation 2 2 Setup 4 3 Troubleshooting 7 L00410627-02_02 1

Installation 1 Installation 1 This manual describes the installation of the GSM option in the FLX series inverter. Before installation, have the following ready: GSM option (1), antenna cable (2), and antenna (3), see Illustration 1.1 Manual Active SIM card with PIN code GSM 160AA020.10 1 2 160AA025.10 SIM Card Illustration 1.2 GSM Option 1 2 Illustration 1.1 Scope of Delivery - GSM Option Kit 3 1 Antenna cable connection point 2 SIM card slot WARNING Before starting work on the inverter, switch off AC at the mains switch and PV using the PV load switch. Before proceeding wait at least 8 minutes after disconnection from grid and PV panels, until the inverter has completely discharged. Failure to switch off AC and PV and wait for discharge may result in personal injury. 160AA021.10 1 The inverter will only detect the option, when the option is installed in an unpowered state. CAUTION Do not penetrate or open the housing of the option. Opening or penetration may result in equipment damage. Illustration 1.3 Insert and Lock SIM Card 2 1.1 Installation To install the option: 1. Take the GSM option. Insert the SIM card into the slot labelled 'SIM Card'. See Illustration 1.2. Push the card fully into position. Secure it by moving the slider to locked position. See Illustration 1.3. 1 SIM card in the slot 2 Slider in the locked position 2. On the inverter, open the cover of the installation area. 3. Insert the GSM option into one of the two option slots; option slot 1 or option slot 2, see Illustration 1.5. Fasten with a click on both sides of the option. 4. Remove the plastic cap from the antenna mounting hole. The hole is located at the centre 2 L00410627-02_02

Installation of the inverter base plate and is labelled GSM. See Illustration 1.2. 5. Take the antenna cable. Insert the bulkhead connector on the antenna cable through the antenna mounting hole. Fasten it with washer and screw on the outside of the base plate. 6. Mount the antenna on the bulkhead connector. See Illustration 1.4. 1 160AA027.10 1.2 Removal To remove the option: 1. Insert a screwdriver at the snap connector on the side of the option. 2. Apply pressure sideways to release the snap connector as shown in Illustration 1.6. 3. Lift the option off the option slot. 160AA029.10 1 1 Illustration 1.4 Correctly-mounted Antenna 1 Antenna 7. Take the free end of the antenna cable. - Fasten the connector to the GSM option at the point labelled GSM Ant. See (1) in Illustration 1.5. - Check the finished installation is correct, according to Illustration 1.5. 1 160AA026.10 Illustration 1.6 Removal of Option 1.3 Closure and Verification 1. Close the cover of the inverter installation area. Ensure that the cover is correctly fastened. 2. Turn on PV and AC connection. 3. Verify that the option is detected. Refer to 2.1.1 Verification. 3 2 Illustration 1.5 Correctly Mounted GSM Option with Antenna 1 GSM option 2 Antenna cable 3 Antenna L00410627-02_02 3

Setup 2 Setup 2 2.1 Prepare for Setup 2.1.1 Verification Verify that the option is detected. 1. Turn on PV and AC connection. 2. In the display, go to [Setup Communication Setup]. 3. If the submenu GPRS connection setup is listed, then this confirms the GSM option is installed correctly. 4. If the submenu GPRS connection setup is not listed, then the GSM option is not installed correctly. Actions: 2.1.2 Preparation - Disconnect PV and AC, and open the cover to the inverter installation area as described in 1.1 Installation. - Check the option is installed with a click. - Check that antenna cable connectors are not damaged. - Repeat steps 1 3. - If the submenu is still not visible, contact hotline. For setup of communications, have the following ready: GSM option with SIM card installed in inverter GPRS connection information from the GPRS service provider: access point name, username and password, if applicable For data warehouse service: username, password and FTP server address. When the provider is CLX Portal, find username and password at [Plant Topology Information]. For access to the inverter display and/or web interface: password To avoid errors during upload, ensure that time and date are set correctly in the inverter. In the display, go to [Setup Inverter details Set date and time]. In the web interface, go to [Inverter level: Setup Inverter details Set date and time]. 2.2 Setup via Display Procedure: 1. Go to [Setup Communication Setup GPRS connection setup]. 2. Set up as follows: Enter PIN code, if applicable. Enter access point name. Enter username and password, if applicable. Set Roaming support to Enabled/ Disabled. NOTE Data roaming can be very expensive. 3. Press Back. Go to [Setup Communication Setup Communication channel Data warehouse service]. 4. Set up as follows: Set Communication channel to GSM. Verify that the data warehouse FTP server address is set. For example, clxportal.danfoss.com. Verify that the data warehouse server port is set to [21]. Verify that the FTP mode is set to Active. Enter the username and password as provided by the data warehouse provider. Wait at least 10 minutes after power up, before data upload. Press Start log upload. 5. Go to [Status Inverter Upload status]. 6. Verify the following: Signal strength is between 16 and 31. Upload status changes from Initializing to Uploading/Idle. The network provider of the SIM card is displayed. The most recent upload is shown. 4 L00410627-02_02

Setup 2.3 Setup via Web Interface 2.3.1 Communication Channel [0] [Plant] This menu item is available only for the FLX Pro inverter, set up as master. Selection of a communication channel is the first step in configuration of e-mail transmission and FTP upload. 2.3.2 GPRS Setup [0] [Plant] This menu item is available only for the FLX Pro inverter set up as master, equipped with GSM option and a valid SIM card. Configure the GPRS settings of the inverter here. These settings enable the GSM modem to connect to the Internet to send e-mails or upload data to a data warehouse or FTP server. 2 2 Illustration 2.1 Communication Channel Item Communication channel Description Select the desired communication channel for FTP upload and e-mail transmission. Select GSM. Default is Not present. E-mail and FTP upload configuration Illustration 2.2 GPRS Setup for GSM Networking Selection of a communication channel is required to define a route for e-mail transmission and/or FTP upload. Procedure: Select GSM to transmit FTP upload and e-mails via the GSM option. To fully activate e-mail communication or FTP upload, additional configuration is required. For further information, refer to 2.3.2 GPRS Setup [0] [Plant] and 2.3.3 Data Warehouse [0] [Plant] /FTP Server Upload in this chapter, and the section SMTP Setup in the FLX Series User Guide. NOTE When the communication channel is set to 'Not present', no FTP upload or e-mail transmission take place, even when GPRS, SMTP and/or data warehouse are configured. SMS configuration For SMS communication, no communication channel setting is required. For configuration of SMS communication, refer to the section STMP Setup in the FLX Series User Guide. Item SIM pin code Access point name Username Password Password again Network roaming Description Enter SIM PIN code, if applicable. The PIN code can consist of 4-8 characters. Connection information from the GPRS service provider. This information, together with a username and password, can be requested by the SIM card supplier and is needed to enable the inverter to dial in to the Internet. Max. 24 characters. Username assigned by the GPRS service provider. Max. 24 characters. Enter the password from the GPRS service provider. Each password character appears as an asterisk (*). Retype the password. Checked (Enabled) Not checked (Disabled) The default setting is not checked. When checked, the GPRS modem can connect to the Internet via a network which is not the home network (a network which does not belong to the network of the telephone company). Roaming will most likely incur extra charges. L00410627-02_02 5

Setup 2.3.3 Data Warehouse [0] [Plant] /FTP Server Upload 2 Illustration 2.3 Data Warehouse Item Upload time [0] Upload interval [0] FTP server address [1] Description Time of day for upload, used only when upload interval is configured to 'daily'. Hourly Daily Weekly Monthly Disabled The FTP server address is user configurable as a name or IP address. Enter maximum 24 characters. FTP server Default port is 21. port [1] FTP mode [1] FTP server username [0] Password [0] Start log upload now [0] Default mode is Active. Enter the username needed for the FTP/data warehouse account. If empty, the serial number of the inverter is used. Enter maximum 24 characters. The password for the FTP/web portal account. Enter maximum 24 characters. Tests the FTP upload immediately. To check status go to [Plant Status Upload status]. NOTE A prerequisite for a successful data transfer to the data warehouse is a valid and active portal account. Receive further details directly from the data warehouse/web portal provider. To register the inverter at a data warehouse provider, use the final 10 digits of the master inverter serial number. Find the serial number here: [Inverter level: Status Inverter], or on the product label on the side of the inverter. 6 L00410627-02_02

Troubleshooting 3 Troubleshooting If the data upload is unsuccessful: 1. Confirm that the GSM option is correctly installed and can be detected, see section 1.3.1 Closure and verification. 2. Find the event ID reported by the GSM modem: In the display, go to [Status Inverter Modem]. In the web interface, go to [Plant level: Status Upload status]. Find the event ID under [Last error]. 3. Refer to the event list in the FLX Series User Guide for explanation of error codes and recommended action. 3 3 L00410627-02_02 7

Danfoss Solar Inverters A/S Ulsnaes 1 DK-6300 Graasten Denmark Tel: +45 7488 1300 Fax: +45 7488 1301 E-mail: solar-inverters@danfoss.com www.danfoss.com/solar Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Rev. date 2013-05-01 Lit. No. L00410627-02_02