Extollo Communications. Home Electrical Wiring and Cross Phase Coupling Overview

Similar documents
SECTION 2 TECHNICAL DESCRIPTION OF BPL SYSTEMS

Application Note. Troubleshooting Communications

Services. Three Phase Service

Definition AC Power Distribution

FW-X240 AUTO TRANSFORMER Installation Manual

The Different Types of AC Power Connectors in North America

Three-Phase Electric Power Distribution for Computer Data Centers

Preface. Manual Revisions

SPL 2-00/-01 OPERATION INSTRUCTIONS

Short Circuit Current Calculations

The Different Types of AC Power Connectors in North America

Installation Manual Version 7.3 IMPORTANT:

Grounding Demystified

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

BASIC NEC CODE RULES AND DESIGN PRACTICE

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

Installation Instructions

INSTALLATION & SERVICE MANUAL. Display Panel

Tips for connecting 24-volt power

How To Use A Power Supply On A Powerline 2.2 (Ai)

Objectives. Electric Current

Movable Wall 8-Wire Base Electrical System - Product Notes

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Current Transformers

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Series and Parallel Circuits

Neutral Wire Facts and Mythology. White Paper #21

Broadband over Power Line (BPL) Test Procedures and Equipment Authorization

Parallel Circuits. Objectives After studying this chapter, you will be able to answer these questions: 1. How are electrical components connected

Installation Instructions

Installation Instructions For Slider Casement Air Conditioners

On/Off Relay Switch and 3-Way Switch Kit

Measurement, Modeling and Simulation of Power Line Channel for Indoor High-speed Data Communications

About the HotWire Slot Standalone Shelf

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

Cable/Conduit Conversion

TECHNICAL BRIEF. Commercial PV in Australia and New Zealand Using the Enphase Microinverter System

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

Product Guide. Low voltage grounding system. Answers for industry.

EMC analysis of LF unstructured telecom networks

Prototyping Printed Circuit Boards

Creating a Usable Power Supply from a Solar Panel

FREQUENTLY ASKED QUESTIONS: HOMEPLUG

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Fundamentals of Power

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Powerline Network. RPL-85 User Manual RPL-85. Powerline Ethernet Bridge V All rights reserved. Page 1

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Power Distribution in Data Centers: STARLINE Track Busway, PX ipdus and Power IQ

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

STREETLIGHT SYSTEM GROUNDING AND BONDING

Figure. 1 - Split Phase 240/120V circuit (180 phase shift)

Generator Transfer Switch Model # HTS15-AUTO

AV1200 TL-PA8030P KIT. 3-Port Gigabit Passthrough Powerline Starter Kit. Highlights

Left Hand Limit Switch. Housing. Left Hand. Connections. Motor Connector BROWN PURPLE GRAY BLACK DARK BLUE BLACK BROWN BROWN LIGHT BLUE.

WEEE Directive & Product Disposal

Design of Bidirectional Coupling Circuit for Broadband Power-Line Communications

Cumbria Designs T-1. SSB/CW Filter kit (4.9152MHz) User Manual

Companion Service Guide

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

NETWORKING GUIDE. designed to be better.

CPS Y S K CPS Y S C

Protect your home and family with Advanced Technology from Cutler-Hammer

Type SA-1 Generator Differential Relay

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Buck - Boost Transformers

Power Plant Electrical Distribution Systems

Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere

Current Cost TREC Current Cost ENVI Current Cost EnviR SmartNow Solar Monitoring Kit

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

The Ultimate Truck Stock Motor

ECOSMART TROUBLE SHOOTING GUIDE MODELS ECO18-ECO27

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

SPEED CONTROL SYSTEM

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Three-phase AC circuits

Components. Transformers

Enhanced In-house Voice Communication over Power- Line Network

What Is Regeneration?

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Performance Measurements on Power Line Carrier Data Transmissions in Indoor Office Environments

Colocation MIX

PV (photovoltaic) Basics There are generally two types of PV systems. The first and easiest (though the least flexible) is a grid tie system where

Powerline 1200 User Manual

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

RC NETWORKS SALES GUIDE

Model Number Electrical Compatibility Module Connector Type. M LL-S22 60 cell PV module MC-4 Type 2 Locking

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

ANI Instruction Manual DIGITAL INDOOR/OUTDOOR TV ANTENNA OMNI-DIRECTIONAL WITH AMPLIFIER INTRODUCTION:

Before installing unit, please carefully look over Installation Guide.

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Balanced vs. Unbalanced Audio Interconnections

High-Efficiency AC Power Distribution for Data Centers

HP 8970B Option 020. Service Manual Supplement

Arc Fault Circuit Interrupters Frequently Asked Questions

PORTABLE GENERATORS AND OSHA CONSTRUCTION REGULATIONS

Transcription:

Extollo Communications Home Electrical Wiring and Cross Phase Coupling Overview

Table of Contents Introduction... 3 Electrical Wiring in the Typical North American Home... 3 Figure 1. Transformer for a typical North American home... 3 Figure 2. Electrical wiring in a typical North American home... 4 The Cross-Phase Coupling Problem... 5 Figure 3. Electrical outlets in a typical North American home... 5 Solving the Cross-Phase Coupling Problem... 5 Figure 5. The electrical panel acts as a cross-phase coupler... 6 Figure 6. The cross-phase coupler path... 6 Conclusion... 7 Technical Details... 7 Three-Phase Power... 7 References... 7 2

Introduction One of the questions often asked is: Will HomePlug adapters communicate with each other if they are on different electrical phases. The answer is yes. Many Powerline Communications (PLC) products developed prior to the HomePlug AV and AV2 standards had a coverage problem. A PLC adapter placed in a particular power outlet in the home often could only communicate with a subset of the other power outlets in the home and not every other outlet in the home. This is referred to as a cross-phase coupling problem. The cross-phase coupling problem raised questions about the nature of home electrical wiring and the reliability of power lines as a communications medium. This Tech Note explains the basics of typical home electrical wiring, the cross-phase coupling problem, and how HomePlug solved the problem. Electrical Wiring in the Typical North American Home To improve efficiency, electrical power is distributed through cities and neighborhoods at high voltages of typically 6 to 16 thousand volts (kv). Near the home, a utility step-down transformer reduces the voltage down to 240 V. The leads from the two 240 V windings of the utilities distribution transformer are called Line1 and Line2. The 240 V power is a push-pull potential force that is divided evenly between Line1 and Line2. The utility distribution transformer is typically deployed on a gray pole-mount can or green pad mount box and supplies, on average, four homes per transformer. The schematic of a typical transformer is shown in Figure 1 below. Figure 1. Transformer for a typical North American home To provide the 110 V power available in most of the 2 and 3 prong electrical outlets in the typical home, the phase is split; a center tap is added to the 240 V side of the transformer. This center tap is called Neutral and is tied to ground in the electrical service panel in the home. Center tapping a transformer is like sitting at the center of a see-saw, the Line1 and Line2 potentials push up and down on either side of you and the center stays steady. The result is that there is 120 V of potential between Line1 and Neutral and between Neutral and Line2. 3

Inside the electrical service panel in the home, branches of electrical outlets are attached through circuit breakers to one of the two available 120 V phases, as shown in Figure 2 below. As each circuit breaker is added to the panel, the mechanical connection alternates between attaching the branch to the 120 V between Line1 and Neutral or the 120 V between Neutral and Line2. This configuration allows devices with high power consumption requirements, such as electric stoves and air conditioners, to take advantage of the higher 240 V available by connecting between Line1 and Line2. When you look at a normal 120-volt outlet in North America, there are two vertical slots and then a round hole centered below them. The left slot is slightly larger than the right. The left slot is called "neutral," the right slot is called "hot" and the hole below them is called "ground." If an appliance is working properly, all electricity that the appliance uses will flow from hot to neutral. Figure 2. Electrical wiring in a typical North American home 4

The Cross-Phase Coupling Problem In Figure 3 the outlets have been given individual names to aid in this discussion. Powerlines attenuate signals. As the signal travels farther and farther down the powerline it becomes smaller and smaller until the signal is no longer usable. Devices communicating on the same phase, such as a device from outlet L1A to a device on outlet L1B, the signal has a relatively short path, Line1, on which to travel. Even when two outlets are on different branches but on the same phase, Line1 provides a relatively short path. Attenuation is often measured in db. The typical outlet to outlet path has an attenuation of between 30 to 50 db. HomePlug AV technologies have a dynamic range of 70-80 db with AV2 having a dynamic range of 70-90 db. Therefore, the signal can be attenuated by 70-90 db before it is lost. Figure 3. Electrical outlets in a typical North American home The cross-phase coupling problem happens when a device in outlet L1A tries to communicate with a device in outlet L2A. The only path from Line1 to Line2 is the long wire (red line) from the electrical panel out to the utilities distribution transformer, through the highly attenuating distribution transformer, and back down the long wire from the utilities distribution transformer to the electrical panel. In this scenario, the attenuation from Line1 in the electrical panel to Line2 in the electrical panel can be 35 db or higher. Add 35 db to cross the panel to the 50 db required for an outlet to outlet connection and the total attenuation comes close to exceeding the 90 db link budget provided by the dynamic range of HomePlug s AV2 technology. The result is that older generation PLC technologies achieve approximately 80% coverage. If you walk around a house and do a random outlet to outlet test checking for a connection, the technology will work in 4 out of 5 connections, or 80% of the time. Solving the Cross-Phase Coupling Problem Older generation powerline technologies use relatively low signaling frequencies, typically below 2 MHz. HomePlug AV2 uses much higher signaling frequencies, 2-86 MHz. At these frequencies, the Bus Bars in the electrical service panel start to look like a capacitor. The Bus Bars are two large copper bars that run down the center of the electrical service panel to which the circuit breakers physically attach. The electrical Panel acts as a cross-phase coupler, as shown in Figure 5. 5

Figure 5. The electrical panel acts as a cross-phase coupler The result is that HomePlug signals couple, or radiate across the electrical panel s circuit breaker Bus Bars with as little as 5 db of loss. Therefore, the powerline signals of an adapter on Phase 1 can communicate with an adapter on Phase 2 through the Bus Bars in the electrical service panel as shown in Figure 6. Figure 6. The cross-phase coupler path 6

Conclusion HomePlug technology addresses all of the challenges present in communicating on the electrical powerlines within the home. HomePlug s AV2 standard improves the rate-reach performance within the home, resulting in a 99% in home coverage. Technical Details Electrical currents travel in closed loops, not point-point connections as illustrated in the figures. For each of the paths described here, the loop is closed by a return path on the Neutral. However, this does not affect the explanation. Though it is equally valid to state that the signal travels on the neutral, the current loop concept will illuminate the same result: the return path of the loop may have to travel across phases. Three-Phase Power Some homes, particularly those in Multi-Dwelling Units and 240 V nations, may use three-phase power instead of split phase power. The result is that there may be a third line, Line3, entering the home. Though the details of the diagrams change, the end results do not. References Intellon s application note 26002637 National Electrical Code (NEC) IEEE National Electrical Safety Code (NESC ) 7