NREL s Plans & Strategies for Building Green Data Centers



Similar documents
Reducing Data Center Loads for a Large-Scale, Net Zero Office Building

Bytes and BTUs: Holistic Approaches to Data Center Energy Efficiency. Steve Hammond NREL

Trends in Data Center Design ASHRAE Leads the Way to Large Energy Savings

Green Data Centre Design

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.

AIA Provider: Colorado Green Building Guild Provider Number: Speaker: Geoff Overland

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Managing Data Centre Heat Issues

Overview of Green Energy Strategies and Techniques for Modern Data Centers

CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense

Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Energy Efficiency and Green Data Centers. Overview of Recommendations ITU-T L.1300 and ITU-T L.1310

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

Re Engineering to a "Green" Data Center, with Measurable ROI

Reducing Data Center Energy Consumption

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

Top 5 Trends in Data Center Energy Efficiency

Data Center Components Overview

Server Room Thermal Assessment

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Office of the Government Chief Information Officer. Green Data Centre Practices

NetApp Data Center Design

Scalable. Affordable. Flexible. Fast.

How To Power And Cool A Data Center

abstract about the GREEn GRiD

Data Center Equipment Power Trends

Solve your IT energy crisis WITH An energy SMArT SoluTIon FroM Dell

Increasing Energ y Efficiency In Data Centers

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Data Center Energy Profiler Questions Checklist

Making Existing Server Rooms More Efficient Steve Bowes-Phipps, Data Centre Manager University of Hertfordshire.

DATA CENTERS BEST IN CLASS

European Code of Conduct for Data Centre. Presentation of the Awards 2014

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Greening Data Centers

Energy Efficiency and Availability Management in Consolidated Data Centers

Data Centers That Deliver Better Results. Bring Your Building Together

Best Practices. for the EU Code of Conduct on Data Centres. Version First Release Release Public

Global Green Data Center Best Practices In Action

Data Center & IT Infrastructure Optimization. Trends & Best Practices. Mickey Iqbal - IBM Distinguished Engineer. IBM Global Technology Services

Green Data Centre: Is There Such A Thing? Dr. T. C. Tan Distinguished Member, CommScope Labs

Data Centers: Definitions, Concepts and Concerns

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

ALWAYS ON GLOBALSWITCH.COM

Steps to Achieve Green Data Center

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling

THE GREEN DATA CENTER

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

The New Data Center Cooling Paradigm The Tiered Approach

Choosing Close-Coupled IT Cooling Solutions

Managing Power Usage with Energy Efficiency Metrics: The Available Me...

1. Data Centre Environment Why focus on Data Centres? Hitachi Eco-Friendly Data Centre Solutions

Energy Recovery Systems for the Efficient Cooling of Data Centers using Absorption Chillers and Renewable Energy Resources

DataCenter 2020: first results for energy-optimization at existing data centers

BRUNS-PAK Presents MARK S. EVANKO, Principal

How green is your data center?

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.

Enabling an agile Data Centre in a (Fr)agile market

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Hot Air Isolation Cools High-Density Data Centers By: Ian Seaton, Technology Marketing Manager, Chatsworth Products, Inc.

ICT and the Green Data Centre

Specialty Environment Design Mission Critical Facilities

AIRAH Presentation April 30 th 2014

Introduction to Datacenters & the Cloud

- White Paper - Data Centre Cooling. Best Practice

Guideline for Water and Energy Considerations During Federal Data Center Consolidations

AIR-SITE GROUP. White Paper. Green Equipment Room Practices

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

European Business Reliance Centres when Commodity serves Green IT

Building a data center. C R Srinivasan Tata Communications

Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre

BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0

Energy Management Services

BICSInews. plus. july/august Industrial-grade Infrastructure. + I Say Bonding, You Say Grounding + Data Center Containment.

DataCenter Data Center Management and Efficiency at Its Best. OpenFlow/SDN in Data Centers for Energy Conservation.

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

DOE FEMP First Thursday Seminar. Learner Guide. Core Competency Areas Addressed in the Training. Energy/Sustainability Managers and Facility Managers

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015

Transcription:

NREL s Plans & Strategies for Building Green Data Centers 2009 DOE Information Management Conference Chuck Powers March 2, 2009 NREL is a national laboratory of the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy operated by the Alliance for Sustainable Energy, LLC

What Makes NREL Unique? Only national laboratory dedicated to renewable energy and energy efficiency R&D Collaboration with industry and university partners is a hallmark Ability to link scientific discovery and product development to accelerate commercialization

Technology Development Programs NREL R&D Portfolio Efficient Energy Use Vehicle Technologies Building Technologies Industrial Technologies Renewable Resources Wind and water Solar Biomass Geothermal Energy Delivery and Storage Electricity Transmission and Distribution Alternative Fuels Hydrogen Delivery and Storage Foundational Science and Advanced Analytics

Research Support Facility (RSF) LEED Platinum Plus 220,000 sq. ft. Supports ~750 administrative staff Complete July 2010 Contain NREL Data Center Model for new buildings

Research Support Facility (RSF) Use of renewable / recycled energy 750kW PV array Renewable Fuels Heating Plant Waste heat from Data Center

Research Support Facility (RSF) Energy efficiency Average DOE lab: 80.6kW / sq. ft./ yr. National average: 22kW Denver building code: 14.6kW Energy goal for RSF: 7.3kW / sq. ft./ yr. 1/10 th of the DOE lab average!

Why is Data Center Efficiency Important? Data centers are facing a power and cooling crisis Data centers use 2-3% of all power produced in the U.S. Data center power demands are increasing Energy costs expected to rise Energy costs expected to exceed equipment costs

Data Center Power Usage The data center energy challenge affects both physical data center and IT infrastructure % of total data center electricity use 35 30 25 20 15 10 5 Cooling systems Electrical and building systems Chiller/ Cooling Humidifier Air- Conditioning PDU Power use UPS Switch/ gen Lighting Information Technology Optimize Data Center Infrastructure Energy Efficiency Source: Gartner Active Energy Management Optimize IT Infrastructure Energy Efficiency

Power Usage Effectiveness (PUE) PUE= Cooling + Power + Equipment Equipment

Free Cooling 80 70 60 50 Dew Point (F) 40 30 20 dehumid economizer evap ind_evap mix mix_humid 10 0-20 0 20 40 60 80 100 120-10 -20 Dry Bulb (F)

Cooling System Custom hybrid cooling system using air-side economizer, water-side economizer and chilled water Layout data center using hot and cold aisles Contain heat produced by equipment Waste heat will be use to supplement building heat

Uninterruptible Power Supply (UPS) 96% energy efficient Designed for scalability Provides 15 minutes of uptime Operate in efficiency Sweet Spot

Other Power Stuff Power Distribution Unit 98.6% efficient Lighting Energy efficient lights Motion sensors Day lighting

Power Usage Effectiveness (PUE) PUE= Cooling + Power + Equipment Equipment

Servers Moving towards high-density blade servers Highly efficient power supplies Variable speed fans Wake-on-LAN Server consolidation/virtualization Ratio: 4-8 to 1 VMware for Windows & LINUX Solaris Containers on Sun Increase server utilization Nominal increase in energy consumption for a higher server utilization

Virtualization Effect on Power Footprint 4:1 Virtualization 4 1U Servers @ 302W ea. Total 1.208kW 1 Blade Server @ 195.25W 4 Virtual Servers @ 48.8125W each

Dynamic Workload Management Server resources go from always on to always available As resources are needed, they are brought online As resources are no longer required, they are powered down or put in standby Saves energy

Network/Telecommunications Network must be always on Right-size 100Mbps to desktop Reevaluate VoIP phone selection Carefully manage # of ports Consider ways to leverage network to improve environmental impact Use virtual connections for blade servers

Storage Storage consolidation Thin provision Use data de-duplication and file compression Use appropriate RAID configuration Use largest disks possible Use tiered storage strategy

Current Data Center 30 years old 2,500 sq. ft. Supports corporate data center functions and HPC Challenged to support growing demands for space, power and cooling Inefficient power and cooling systems No backup generator power Performed energy audit to identify investments required to extend longevity Estimated PUE of 2.5

Expected Reduction in Data Center Power Target PUE of 1.1 65% overall reduction in data center power Equipment 30% more efficient Equipment load increased from lab growth and new capabilities

What does this mean? Better understand system requirements for projects Right-size systems Architect for scalability Make better use of existing system resources Turn off resources not in use Enhance capacity management processes Consider power costs in TCO for IT investments

Energy System Integration Facility (ESIF) ESIF - Focus on renewable energy systems integration 130,000 g.s.f. building, ~200 staff Mixture of office and lab space High Performance Computing 15,000 g.s.f. Data Center 2011: 200+ Tflops 1+ PByte storage 2014: 1+ Pflop Planning horizon 2010 to 2025.

ESIF: Data Center Dual Mission: Petascale system to meet NREL HPC computing needs, and Showcase for data center energy efficiency. Holistic view: integrate HPC equipment and a Data Center into an energy efficient building and campus. Integrate state-of-the-art technologies and design practices. Chips to Bricks approach. Unique opportunity with new construction.

Optimizing ESIF s Data Center Performance Seasonal PUE targets with fall, winter, spring PUE < 1! NO mechanical cooling or perimeter CRAC units Leverage favorable climate, evaporative cooling only Rely heavily on liquid cooling UPS exclusively for critical components Numerous waste heat utilization opportunities (pretreat lab air, radiant heating in office space, snow melt, ) Monitor PUE (power usage effectiveness) PUE = Total Power / IT Equipment Economizer hours, temperature profiles, allowable conditions Dashboards to report instantaneous, seasonal and cumulative PUE values

Best Practices for Green Data Centers Use energy-efficient equipment Upgrade legacy equipment Consolidate & virtualize servers Right-size IT infrastructure Good relationship between IT and Facilities Track & manage data center energy consumption Perform long-term capacity planning for power Make energy consumption a part of TCO analysis Implement targeted/adaptive cooling solutions Improve airflow management 26

10 Things You Can Do Now to Make Your Data Center More Efficient Decommission obsolete equipment Perform regular maintenance on Computer Room Air Handlers Remove excess sub floor cabling and wiring Replace long power cords with shorter lengths to improve air flow Get rid of rack spaghetti, use wire management and ties to secure wiring Turn off the lights install motion sensor switches if possible Cover all open rack spaces with blanking panels Use Kool Loc to cover floor openings and brush panels front mounted cable connections Configure your racks in a hot aisle/cold aisle Contain either hot aisle or cold aisle 27

The Green Workplace Source: Corné de Graaf 28

Campus of the Future Prototype NREL leased a LEED certified building to house 128 IT staff The office environment Low cube heights for light and air circulation huddle rooms for privacy New technologies for collaboration Idea paint whiteboarding on the walls Electronic white boards Unified Communications Headset Computer, phone, mobile device Energy conservation Replace printers/copiers/fax with all-in-one Belt-high outlets for visual awareness Personal refrigerators, microwaves and coffee pots not allowed Green recycling practices Hardware Recycle at 80 - simple trash 29

Culture Change Started with 80% resistance Lack of privacy Managers/Director do not have hard-walled offices Loss of convenience Separation from campus Currently less than 10% resistance Several of most concerned are raving Light lifts mood Everyone has a window The Walton s Experiences will influence NREL s Campus of the Future

31

32

Desktop Environment Manage workstation lifecycle for environmental impact Use energy-efficient LCD monitors Use laptops with docking stations for road warriors & day extenders Evaluating the use of thinclient technology at the desktop Workstation Type Power Reduction Standard PC 400w 0% Energy Star PC 300w 25% Laptop 60w 85% Thin Client 35w 91% 33

Technologies in Evaluation Application virtualization Thin clients Hot Desking Workstation Energy Measurement Virtual proximity Microsoft Unified Communications Round Table Telepresence State-of-the-art conference rooms Electronic whiteboards Large monitors Electronic room control

RSF Prototype Henri Hubenka Manager, Client Services henri.hubenka@nrel.gov (303) 275-4155

NREL Data Center Contacts: Chuck Powers, Manager Information Technology Infrastructure and Operations chuck.powers@nrel.gov (303) 275-4182 Kevin Donovan, Data Center Manager kevin.donovan@nrel.gov (303) 275-4169