TriStar II Surface Area and Porosity Analyzer



Similar documents
ASAP Accelerated Surface Area and

TriStar II Surface Area and Porosity System. The Science and Technology of Small Particles

Pore size and BET surface area. analysis at your fingertips. SA Gas Adsorption Analyzer

Texture characteristic of membrane materials ASAP, BET

PHYSISORPTION DETERMINATIONS

The PMI Advanced. BET SORPTOMETER BET-201-AELC-2OS Not just products...solutions!

Surface Area and Porosity

Analytical Services. Part number Measurement Description. Single-Point BET with Nitrogen N. Multi-Point BET With Nitrogen N

FINESORB Surface Area. as or more than m 2 /g. Distribution of Pore nm. Degas & Analysis Up to 12 Degas & 6 Analysis Station

presented by Neal Leddy CMA Analytical Workshop 2012 SURFACE AREA AND POROSITY

BET Surface Area Analysis of Nanoparticles

Low Temperature Adsorption Versus Pore Size in Activated Carbons

Physical Chemistry Practical Course, Oxford University. Determination of the Surface Area of Alumina by Nitrogen Adsorption at 77K (4 points)

EXPERIMENTAL METHODS IN COLLOIDS AND SURFACES

Pharmaceutical Physical Characterization: Surface Area and Porosity

CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS

Characterization of Gas Shale Pore Systems by Analyzing Low Pressure Nitrogen Adsorption

Micromeritics BET Surface Area and Porosity Analyzer Instrument Information and Generalized Standard Operating Procedure

Adsorption. December 2014

Heterogeneous Catalysis and Catalytic Processes Prof. K. K. Pant Department of Chemical Engineering Indian Institute of Technology, Delhi

A New Technique Provides Faster Particle Size Analysis at a Lower Cost Compared to Conventional Methods

Hydrogen Adsorption on Nanoporous Biocarbon

ORGANIC SAMPLE PREPARATION

Standard Test Methods for Carbon Black Surface Area by Multipoint B.E.T. Nitrogen Adsorption 1

Fiscal Measurement Natural Gas

Facts About. Industrial gases for better injection molding. This article appeared in the trade journal Kunststoffe plast europe, issue 12/2004.

On-line Dissolved Gas Analysis

(S&G 5th ed. Expt 27, 6th, 7th & 8th eds. Expt 26)

This document is a preview generated by EVS

still different technique of assessment.

UOP Adsorbents COMPREHENSIVE PORTFOLIO TO REMOVE CONTAMINANTS FROM A VARIETY OF SOURCES. UOP Adsorbent Solutions

Vacuum Pumping of Large Vessels and Modelling of Extended UHV Systems

Lecture 35: Atmosphere in Furnaces

MERCURY REMOVAL FROM NATURAL GAS AND LIQUID STREAMS ABSTRACT. Giacomo Corvini, Julie Stiltner and Keith Clark UOP LLC Houston, Texas, USA

Effect of surface area, pore volume and particle size of P25 titania on the phase transformation of anatase to rutile

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

GRANULAR ACTIVATED CARBON FOR WATER & WASTEWATER TREATMENT

ISO INTERNATIONAL STANDARD

Development of porous materials for hydrogen storage

Putting a chill on global warming

CHARACTERIZATION OF POROUS GLASS

SAMPLE CHAPTERS UNESCO EOLSS NATURAL GAS PROCESSING. H. K. Abdel-Aal National Research Center (NRC), Cairo, Egypt

Description of Thermal Oxidizers

Motivation Physisorption Chemisorption Outlook

MATHESON REFINERY PROGRAM for Specialty Gas Supply. Experience the MATHESON Commitment to Supply Chain Excellence

Supporting Information

Some generalization of Langmuir adsorption isotherm

SYLOBEAD Adsorbents. for Natural Gas Processing. Introduction. Therefore, it is often necessary to condition the raw gas to:

Chapter 5 - Aircraft Welding

ENERGY CARRIERS AND CONVERSION SYSTEMS Vol. II - Liquid Hydrogen Storage - Takuji Hanada, Kunihiro Takahashi

Appendix A. Fig. 1 Nitrogen adsorption for Activated Carbon from Norit

ADSORPTION OF N2 ON SILICA GEL

BTU ANALYSIS USING A GAS CHROMATOGRAPH

Nano-pore structure characterization of shales using gas adsorption and mercury intrusion techniques

SPECIFICS ON SURFACE AREA Rebecca Lea Wolfrom

INSTALLATION AND OPERATION OF AUTOSORB-l-C-8 FOR BET SURFACE AREA MEASUREMENT OF POROUS MATERIALS

MILESTONE. SynthWAVE. The Game Changer in Microwave Synthesis

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Decaffeination of Raw, Green Coffee Beans Using Supercritical CO 2

POROSITY OF THE FINE FRACTIONS OF FINNISH TILLS

ASimple Guide to Oil Refining

POLLUTED EMISSION TREATMENTS FROM INCINERATOR GASES

Molecular Sieve Adsorbents

Chapter 7: Oil Vapor Diffusion Pumps

Measurement of Specific Heat Capacity Using Differential Scanning Calorimeter

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

N O T E S. Environmental Forensics. Identification of Natural Gas Sources using Geochemical Forensic Tools. Dispute Scenarios

Natural Gas Information Contents

THE HUMIDITY/MOISTURE HANDBOOK

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

LNG Fuel Tank System LNG Tank overview

The photoionization detector (PID) utilizes ultraviolet

EXTENDING MOLECULAR SIEVE LIFE IN NATURAL GAS DEHYDRATION UNITS

Science Standard Articulated by Grade Level Strand 5: Physical Science

Oil Analysis. It is important that the sampling be done in the following manner: 1.

Chromatograph Maintenance and Troubleshooting Class # 5050

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

EcoCWave. The all-round talent for aqueous part cleaning.

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Ferda ORHUN Mineral Research and Exploration Institute of Turkey

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Sterilization methods and equipment Lab 1-2

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

PROJECT HAZARD ASSESSMENT FORM CHEMICAL HAZARDS

The soot and scale problems

SA-9600 Surface Area Software Manual

VAPOR PRESSURE AS A FUNCTION OF TEMPERATURE. This laboratory covers material presented in section 11.8 of the 9 th Ed. of the Chang text.

Dehydration. Dehydration UNIT. operations. bioprocess plants

German engineering under high pressure

TiO 2. : Manufacture of Titanium Dioxide. Registered charity number

Automotive Base Oil Presentation

The use of nitrogen adsorption for the characterisation of porous materials

BHS CANDLE FILTER APPLICATIONS FOR CLARIFICATION / RECOVERY OF SOLIDS FROM CHEMICAL SLURRIES

1.3 Properties of Coal

Energy Efficient Operations and Maintenance Strategies for Boilers

Viscosity: A Property of fluids Compare the viscosity of various liquids Describe factors that can modify the viscosity of a liquid 208-6

Transcription:

TriStar II Plus

TriStar II Surface Area and Porosity Analyzer Analytical Versatility/ High Throughput/ Small Footprint Surface area and porosity are important physical properties that influence the quality and utility of many materials and products. Therefore it is critically important that these characteristics be accurately determined and controlled. Likewise, knowledge of surface area and especially porosity often is an important key to understanding the formation, structure, and potential application of many natural materials. High Sample Throughput/ Analytical Versatility The TriStar II is a fully automated, three-station, surface area and porosity analyzer that delivers high-quality data at an affordable price. It is capable of increasing the speed and efficiency of routine quality control analyses, yet has the accuracy, resolution, and data reduction capability to meet most research requirements. The TriStar II also features a Krypton Option, allowing measurements in a very low surface area range. The instrument combines versatility in analysis methods and data reduction to allow the user to optimize analyses to specific applications. TriStar II A Small Footprint Packed with Features Three analysis ports can operate simultaneously and independently of one another. Three BET surface area measurements can be performed in less than 20 minutes. For additional throughput, four TriStars can be operated with one computer Surface areas as low as 0.01 m 2 /g can be measured with the standard nitrogen system. The TriStar II accommodates the use of argon, carbon dioxide, and other non-corrosive gases such as butane, methane, or other light hydrocarbons. A Krypton Option can extend surface area measurements to as low as 0.001 m 2 /g A dedicated Po port is standard, allowing the measurement of saturation pressure on a continuous basis. Saturation pressure can be entered manually, measured continuously, or collected over the sample. The TriStar II provides the flexibility to control and fine-tune analysis speed and accuracy Incremental or fixed dosing routines prevent overshooting pressure points while minimizing analysis time Free space can be measured, calculated, or manually entered providing maximum flexibility in accommodating special sample types and emphasizing speed when needed. Helium is not required Enhanced product support features include: video clips; Ethernet communication between the computer and TriStar; bar code reader capability; diagnostic software; ability to perform remote diagnostics via the internet; and the ability to read and compare historical TriStar data to TriStar II data A 2.75-liter dewar and extended length sample tubes allow complete adsorption and desorption isotherms to be collected without operator intervention The TriStar II can collect up to 1000 data points. Fine details of the isotherm can be observed and recorded providing high resolution and revealing pore structure details Intuitive and powerful Windows -based software allows more versatility in data archiving and networking. However, the most powerful features of this software are found in its expanded range of data reduction and reporting. SPC reports, isotherm and thickness models, isosteric heat of adsorption, and integrated DFT models are included Optional sample preparation devices are available combining flowing gas and/or vacuum with heat to remove atmospheric contaminants, such as water vapor and absorbed gas, from the surface and pores of the sample An attractively designed cabinet combines a small footprint with easy accessibility

Operating Software The TriStar II Windows interface provides a familiar environment for the user. It is easy to collect, organize, archive, reduce isotherm data, and store standardized sample information for later use. The reports may be generated to screen, paper, or spreadsheet file. Cut-and-paste graphics, scalable and editable graphs, and customized reports are easily generated. In addition to controlling instrument operation, the Windows software also reduces the isotherm data collected during analysis. The reduced data can be reviewed or printed in a variety of easy-tointerpret tabular and graphical reports. TriStar II Tabular and Graphical Reports: Single and multipoint BET surface area Total pore volume Langmuir surface area and Isotherm reports t-plot - Harkins and Jura Thickness Equation - Halsey Thickness Equation - Carbon STSA - Broekhoff-de Boer - Kruk-Jaroniec-Sayari BJH adsorption and desorption - Standard - Kruk-Jaroniec-Sayari correction Dollimore-Heal adsorption and desorption Mesopore - Volume and area distributions by pore size MP-Method HK Saito-Foley Chang-Yang DFT pore size DFT surface energy Summary Report SPC reports Validation reports

TriStar II Plus Surface Area and Porosity Analyzer Micromeritics' TriStar II Plus is a state-of-the-art instrument suited for use in both quality control and research environments. Intended for laboratories that require high throughput and the highest quality data, it contains all the capabilities of the TriStar II with additional hardware and software features. Advanced Hardware and Software Features The unique stainless steel analysis manifold is corrosive resistant and designed for highly-accurate gas management Improved dewar design provides more than 40 hours of continuous temperature control Available in a krypton capable model for the analysis of very low surface area materials Intuitive MicroActive software gives the user the ability to interactively evaluate isotherm data and reduces the time required to obtain surface area and porosity results User-defined reporting options allow direct modeling Powerful Python scripting language allows users to develop extensions to the standard report library available within the TriStar II Plus software application An innovative dashboard monitors and provides convenient access to real-time instrument performance indicators and maintenance scheduling information Capable of utilizing two isoterms (CO2 and N2) for caculating pore size diameter via NLDFT for micropore analyses of carbons Data Reduction Benefits Interaction with adsorption data is direct. By simply moving the calculation bars, the user is immediately updated with new textual properties. One-click access to important parameters allows the user to focus on the result rather than the parameters Interactive data manipulation minimizes the use of dialog boxes and tunneling of dialogs to specify calculation parameters. This allows the user to accurately and efficiently determine surface area and porosity of their materials Improved ability to overlay files (up to 25) including mercury intrusion data with file add and subtract feature User selectable data ranges through the graphic interface allows direct modeling for BET, t-plot, Langmuir, DFT interpretation, and much more Report Options editor allows the user to define up to five reports with on-screen previews. Each report has the ability to possess multiple summary, tabular, and graphical information panes TriStar II Plus

Enhanced Software Capabilities, Data Reduction Features, and Instrument Monitoring MicroActive for TriStar II Plus Software The intuitive MicroActive for TriStar II Plus software gives the user the ability to interactively evaluate isotherm data and reduce the time required to obtain surface area and porosity results. It is not necessary to generate reports to view results. Calculations, such as the BET surface area transform plot, can be easily generated and adjusted. The selection bars allow for a range of data points to be quickly and easily selected. As a result, the summary of values derived from the calculations is instantly updated. Within the calculation window(s), the range of data used can be further refined. Interactive selection of the BET surface area calculation range Gas Adsorption and Mercury Intrusion Overlay Capability MicroActive for the TriStar II Plus software also includes a powerful utility that allows the user to overlay a mercury porosimetry pore size distribution with a pore size distribution calculated from gas adsorption isotherms. This new import function allows users to rapidly view micropore, mesopore, and macropore distributions in one easy-to-use application. Overlay of BJH desorption and mercury intrusion log differential pore size distributions for alumina pellets Python Programming Language Included The Python programming language has been incorporated into the TriStar II Plus software. This powerful scripting language allows users to develop extensions to the standard report library available within the TriStar II Plus application. New isotherm models or calculations are easily added to the report system. The Python interface to MicroActive allows users to customize their reports and extend the utility of MicroActive.

Dual DFT The Dual DFT NLDFT model allows the user to combine the information gathered from nitrogen and carbon dioxide isotherms to deliver a full pore size distribution on materials (such as carbon slit pores) where pores of molecular sizes are present. The range of pore size analysis in this method is extended to smaller pore sizes compared to the standard nitrogen analysis. This is due to the fact that CO2 can access some very small micropores that are not accessible to N2 at cryogenic temperatures due to size restrictions, connectivity problems, or extremely slow diffusion. TriStar II Plus This advanced NLDFT method allows users to determine the pore size distribution of their sample using two isotherms. In this example CO2 adsorption (red) at 273 K and nitrogen adsorption (green) at 77 K are used to calculate a single pore size distribution. Users do not have to cut and paste distributions from CO2 and nitrogen - a single distribution is determined using both isotherms. With a single click, the TriStar II Plus provides a powerful suite of information that allows the user to maintain the instrument in peak operating condition with real-time analysis views.

External Sample Preparation Devices Micromeritics sample preparation devices prepare batches of samples for surface area and pore volume analysis. They combine flowing gas and/or vacuum with heat to remove atmospheric contaminants, such as water vapor and adsorbed gas, from the surface and pores of the sample. The quality of the data produced by surface area and pore volume analyses depends greatly on the cleanliness of the sample surface. All Micromeritics sample preparation devices accept helium, nitrogen, argon, and other non-corrosive gases. The FlowPrep 060 applies both heat and a stream of inert gas to the sample for removal of adsorbed contaminants from the surface and pores. With six degassing stations, this sample preparation unit lets you choose the temperature, gas, and flow rate best suited for your sample material and application. Needle valves allow the user to introduce the flowing gas slowly to prevent fluidization of samples. The VacPrep 061 offers two methods for removing adsorbed contaminants. In addition to flowing gas, this sample preparation unit provides vacuum to prepare samples by heating and evacuation. The VacPrep offers the user a choice of vacuum or gas flow on each of the six degassing stations. Needle valves allow the user to introduce the flowing gas or vacuum slowly to prevent fluidization of samples. The SmartPrep 065 applies a stream of flowing gas over the sample at elevated temperatures to remove adsorbed contaminants. Temperature, ramp rates, and soak times of each sample are individually controlled on the six degassing stations by a computer. This sample preparation unit contains two serial ports, one for connecting to the computer and the other for connection to an additional SmartPrep. Up to five ramps and soaks are allowed. All degas information is integrated into the sample data file for future reference. Model 021 LN2 Transfer System Micromeritics Model 021 LN2 Transfer System is useful for any number of tasks where frequent needs arise for relatively small volumes of liquid nitrogen or argon. The LN2 Transfer System makes it easy to fill dewars with liquid cryogen for laboratory or general purposes. The system includes a large storage dewar with a 47-liter capacity that can hold liquid nitrogen or argon up to 30 days allowing convenient and cost-efficient use of your cryogen. The 021 LN2 Transfer System operates at ambient pressure and replaces typical cryogen storage vessels which are pressurized to force the cryogen through the discharge line. With Micromeritics system, cryogen is transferred by a centrifugal pump. Flow starts and stops immediately when the pump is turned on or off. The discharge rate is continuously adjustable to a maximum flow of 3 L/min. The discharge line is insulated to prevent frosting and icing during use, and flexible to allow easy positioning for discharge into almost any type of receiving vessel. The system includes a mobile platform which easily rolls from location to location. Additional accessories are available for special applications. LN2 Transfer System To request a quote or additional product information, visit Micromeritics web site at www.micromeritics.com, contact your local Micromeritics sales representative or our Customer Service Department at (770) 662-3636

Applications TriStar II Plus Pharmaceuticals - Surface area and porosity play major roles in the purification, processing, blending, tableting, and packaging of pharmaceutical products as well as their useful shelf life, dissolution rate, and bioavailability. Ceramics - Surface area and porosity affect the curing and bonding of greenware and influence strength, texture, appearance, and density of finished goods. The surface area of glazes and glass frits affects shrinkage, crazing, and crawling. Adsorbents - Knowledge of surface area, total pore volume, and pore size distribution is important for quality control of industrial adsorbents and in the development of separation processes. Surface area and porosity characteristics affect the selectivity of an adsorbent. Activated Carbons - Surface area and porosity must be optimized within narrow ranges to accomplish gasoline vapor recovery in automobiles, solvent recovery in painting operations, or pollution controls in wastewater management. Carbon Black - The wear lifetime, traction, and performance of tires are related to the surface area of carbon blacks used in their production. Catalyst -The active surface area and pore structure of catalysts influence production rates. Limiting the pore size allows only molecules of desired sizes to enter and exit, creating a selective catalyst that will produce primarily the desired product. Paints and Coatings - The surface area of a pigment or filler influences the gloss, texture, color, color saturation, brightness, solids content, and film adhesion properties. The porosity of a print media coating is important in offset printing where it affects blistering, ink receptivity, and ink holdout. Projectile Propellant - The burn rate of propellants is a function of surface area. Too high a rate can be dangerous; too low a rate can cause malfunction and inaccuracy. Medical Implants - Controlling the porosity of artificial bone allows it to imitate real bone that the body will accept and allow tissue to be grown around it. Electronics - By selecting high surface area material with carefully designed pore networks, manufacturers of super-capacitors can minimize the use of costly raw materials while providing more exposed surface area for storage of charge. Cosmetics - Surface area is often used by cosmetic manufacturers as a predictor of particle size when agglomeration tendencies of the fine powders make analysis with a particle-sizing instrument difficult. Aerospace - Surface area and porosity of heat shields and insulating materials affect weight and function. Geoscience - Porosity is important in groundwater hydrology and petroleum exploration because it relates to the quantity of fluid that a structure can contain as well as how much effort will be required to extract it. Nanotubes - Nanotube surface area and microporosity are used to predict the capacity of a material to store hydrogen. Fuel Cells - Fuel cell electrodes require high surface area with controlled porosity to produce optimum power density.