TriStar II Surface Area and Porosity System. The Science and Technology of Small Particles
|
|
|
- Walter Bryan
- 10 years ago
- Views:
Transcription
1 TriStar II 3020 Surface Area and Porosity System The Science and Technology of Small Particles
2 Analytical Versatility/High Throughput/Small Footprint TriStar II 3020 Surface Area and Porosity System Surface area and porosity are important physical properties that influence the quality and utility of many materials and products. Therefore it is critically important that these characteristics be accurately determined and controlled. Likewise, knowledge of surface area and especially porosity often is an important key to understanding the formation, structure, and potential application of many natural materials. High Sample Throughput/ Analytical Versatility The TriStar II 3020 is a fully automated, three-station, surface area and porosity analyzer that delivers high-quality data at an affordable price. It is capable of increasing the speed and efficiency of routine quality control analyses, yet has the accuracy, resolution, and data reduction capability to meet most research requirements. The TriStar II also features a new Krypton Option, allowing measurements in the very low surface area range. The instrument also combines versatility in analysis methods and data reduction to allow the user to optimize analyses to specific applications. A Small Footprint/Packed with Features Three analysis ports operate simultaneously and independently of one another. Three BET surface area measurements can be performed in less than 20 minutes. For additional throughput, four TriStars can be operated with one computer. Surface areas as low as 0.01 m 2 /g can be measured with the standard nitrogen system. The TriStar II also accommodates the use of argon, carbon dioxide, and other non-corrosive gases such as butane, methane, or other light hydrocarbons. A Krypton Option can extend surface area measurements to as low as m 2 /g. A dedicated P O port is standard, allowing the measurement of saturation pressure on a continuous basis. Saturation pressure can be entered manually, measured continuously, or collected over the sample. The TriStar II provides the flexibility to control and fine-tune analysis speed and accuracy. Incremental or fixed dosing routines prevent overshooting pressure points while minimizing analysis time. Free space can be measured, calculated, or manually entered providing maximum flexibility in accommodating special sample types and emphasizing speed when needed. Enhanced product support features include: video clips; Ethernet communication between the computer and TriStar; bar code reader capability; built-in electronic test points and diagnostic software; ability to perform remote diagnostics via the internet; and the ability to read and compare historical TriStar and Gemini data to TriStar II data. A 2.75-liter Dewar and extended length sample tubes allow complete adsorption and desorption isotherms to be collected without operator intervention. The TriStar II can collect up to 1000 data points. Fine details of the isotherm can be observed and recorded providing high resolution and revealing pore structure details. Intuitive and powerful Windows -based software allows more versatility in data archiving and networking. However, the most powerful features of this software are found in its expanded range of data reduction and reporting. SPC reports, new isotherm and thickness models, isosteric heat of adsorption, and integrated DFT models are all included. Optional sample preparation devices are available combining flowing gas and/or vacuum with heat to remove atmospheric contaminants, such as water vapor and adsorbed gas, from the surface and pores of the sample. An attractively designed cabinet combines a small footprint with easy accessibility.
3 Typical TriStar II Applications Pharmaceuticals Surface area and porosity play major roles in the purification, processing, blending, tableting, and packaging of pharmaceutical products as well as their useful shelf life, dissolution rate, and bioavailability. Ceramics Surface area and porosity affect the curing and bonding of greenware and influence strength, texture, appearance, and density of finished goods. The surface area of glazes and glass frits affects shrinkage, crazing, and crawling. Adsorbents Knowledge of surface area, total pore volume, and pore size distribution is important for quality control of industrial adsorbents and in the development of separation processes. Surface area and porosity characteristics affect the selectivity of an adsorbent. Activated Carbons Surface area and porosity must be optimized within narrow ranges to accomplish gasoline vapor recovery in automobiles, solvent recovery in painting operations, or pollution controls in wastewater management. Carbon Black The wear lifetime, traction, and performance of tires are related to the surface area of carbon blacks used in their production. Catalyst The active surface area and pore structure of catalysts influence production rates. Limiting the pore size allows only molecules of desired sizes to enter and exit, creating a selective catalyst that will produce primarily the desired product. Paints and Coatings The surface area of a pigment or filler influences the gloss, texture, color, color saturation, brightness, solids content, and film adhesion properties. The porosity of a print media coating is important in offset printing where it affects blistering, ink receptivity, and ink holdout. Projectile Propellant The burn rate of propellants is a function of surface area. Too high a rate can be dangerous; too low a rate can cause malfunction and inaccuracy. Medical Implants Controlling the porosity of artificial bone allows it to imitate real bone that the body will accept and allow tissue to be grown around it. Electronics By selecting high surface area material with carefully designed pore networks, manufacturers of supercapacitors can minimize the use of costly raw materials while providing more exposed surface area for storage of charge. Cosmetics Surface area is often used by cosmetic manufacturers as a predictor of particle size when agglomeration tendencies of the fine powders make analysis with a particle-sizing instrument difficult. Aerospace Surface area and porosity of heat shields and insulating materials affect weight and function. Geoscience Porosity is important in groundwater hydrology and petroleum exploration because it relates to the quantity of fluid that a structure can contain as well as how much effort will be required to extract it. Nanotubes Nanotube surface area and microporosity are used to predict the capacity of a material to store hydrogen. Fuel Cells Fuel cell electrodes require high surface area with controlled porosity to produce optimum power density.
4 Superior Data Presentation Capability Operating Software The TriStar II 3020 Windows interface provides a familiar environment for the user. It is easy to collect, organize, archive and reduce raw data, and store standardized sample information for later use. The reports may be generated to screen, paper, or data transfer channels. Cut-and-paste graphics, scalable-and-editable graphs, and customized reports are easily generated. In addition to controlling instrument operation, the Windows software also reduces the raw data collected during analysis. The reduced data can be reviewed or printed in a variety of easy-to-interpret tabular and graphical reports. These include: Single- and multipoint BET surface area Total pore volume Langmuir surface area and isotherm reports t-plot - Harkins and Jura Thickness Equation - Halsey Thickness Equation - Carbon STSA - Broekhoff-de Boer - Kruk-Jaroniec-Sayari BJH adsorption and desorption - Standard - Kruk-Jaroniec-Sayari correction Dollimore-Heal adsorption and desorption Mesopore and Macropore - Volume and area distributions by pore size MP-Method DFT pore size DFT surface energy Summary report SPC reports Validation reports For applications that fall under the FDA s 21 CFR 11 rule, Micromeritics optional confirm software option provides the security features and audit trails required by this regulation. This BET plot of 200 m 2 /g silica alumina (red), 50 m 2 /g silica gel (green), and 200 m 2 /g titania (blue) demonstrates the versatility of the TriStar II. Three different materials may be analyzed simultaneously and then overlaid for comparison. An example of an analysis in progress the TriStar II features an embedded microprocessor that controls the unit operation and sample analysis. This userfriendly Windows software allows the user to control the instrument from a workstation, monitor the progress of the analysis, and view the results of the experiment.
5 Pore volume and pore size distributions for several samples may be overlaid to emphasize the difference between various materials. Pore volume and pore size distributions are easily determined using the full-featured TriStar II report system. TriStar II Reference Materials Silica-alumina The silica-alumina is a typical porous high surface area reference material. The surface area of silica-alumina typically exceeds 200 m 2 /g and the pore size is a nominal 100 Å. This material is recommended for users that analyze amorphous materials with surface area ranging from 10 to greater than 300 m 2 /g and for both non-porous and porous materials in the Å range. Silica-alumina is suitable for use with BET, t-plot, and BJH pore size reports. Carbon Black Standard Reference Blacks are available from 20 to greater than 100 m 2 /g. These are stable and very well characterized materials. They are recommended for all users but may be especially suited for researchers in the carbon, tire, and filler industries. The carbon black reference materials are suitable for use with the BET and STSA reports. Glass A 5 m 2 /g glass reference material is recommended for industries and users that characterize materials in the 1 through 50 m 2 /g range. Glass reference material is suitable for use with the BET surface area report. Alumina Low surface area alpha alumina (less than 1 m 2 /g) is available for use with krypton. Alpha alumina is recommended for researchers in the pharmaceutical, abrasives, soil, and other areas that require the characterization of materials with surface areas less than 1 m 2 /g. Alpha alumina reference material is recommended for use with krypton and the BET surface area report.
6 Innovative Design The TriStar II Technique Micromeritics TriStar II utilizes the static adsorption technique. The instrument features a thermally stable dosing manifold (M), a three-port sample manifold, a dedicated tube for measuring saturation pressure (P O ), and a rapid response servo valve (S). The main manifold features a 1000-torr transducer and is coupled to the rapid response servo valve. The servo valve is used for rate-controlled evacuations of the sample, and used throughout the analysis to rapidly and accurately dose the manifold. The servo-controlled evacuation rate may be set by the user to minimize the risk of fluidizing powder samples. For pellets, spheres, extrudates, or other formed samples, the evacuation rate may be set very high to rapidly evacuate the sample tube. J K During a typical analysis, the manifold, sample tubes, and the P O tube are evacuated. After a sufficient vacuum has been achieved, the manifold is filled with helium and then sample port 1 valve is opened to determine the warm free space of sample 1. This sequence is repeated for samples 2 and 3 to determine the free space at room temperature. The elevator is raised and the samples are cooled to nearly 77 K. This allows the free space to be determined at the analysis temperature. Once the free space analysis is finished, the saturation pressure of the adsorptive is determined using the P O tube. Typically nitrogen is dosed into the tube above atmospheric pressure. The nitrogen is allowed to condense and the vapor pressure of the nitrogen is easily monitored by a transducer throughout the analysis. M The adsorption isotherm is rapidly collected by using the servo valve to dose nitrogen into the manifold. The pressure and temperature of the nitrogen are recorded, a sample port is opened, and the nitrogen is allowed to adsorb onto the sample. The quantity of nitrogen removed from the manifold is recorded as the quantity dosed. The sample valve is then closed and the adsorption is allowed to proceed to equilibrium. The quantity adsorbed can be calculated from the quantity dosed minus any residual nitrogen in the sample tube. This process is repeated for all three samples. The analysis is a parallel operation so that while one sample is equilibrating a different sample can be dosed with nitrogen. The order of sample analysis is based on the material, not sequential operation. Samples that adsorb nitrogen rapidly can be analyzed in parallel with materials that are tortuous and require additional time to adsorb nitrogen. This allows the user to characterize three unique materials simultaneously providing rapid, reliable, and repeatable results. S P O The TriStar II also features four gas inlets for probe molecules (J). A typical configuration will feature nitrogen as the analysis gas and helium for determining the void volume of the sample tube. However, two additional gases may be connected for additional flexibility. For example, carbon dioxide is often used for difficult-to-analyze microporous materials, and krypton may be preferred for low surface area samples (requires additional hardware for krypton analysis option-k). Three Parallel Sample Analyses Continuous P O Monitoring Sliding Shield Large Capacity Dewar
7 Accessories Sample Preparation Devices Micromeritics sample preparation devices prepare batches of samples for surface area and pore volume analysis. They combine flowing gas and/or vacuum with heat to remove atmospheric contaminants, such as water vapor and adsorbed gas, from the surface and pores of the sample. The quality of the data produced by surface area and pore volume analyses depends greatly on the cleanliness of the sample surface. All Micromeritics sample preparation devices accept helium, nitrogen, argon, and other non-corrosive gases. The SmartPrep 065 is a flowing-gas degassing unit which removes adsorbed contaminants from the surface and pores of a sample in preparation for analysis. It contains six sample ports, each one independently temperature-controlled for greater flexibility. It contains two serial ports, one for connecting to the computer and the other available for connection of an additional SmartPrep. The temperature, ramp rates, and soak times of each sample are individually controlled by the computer. Up to five ramps and soaks are allowed. All degas information is integrated into the sample data file for future reference. The FlowPrep 060 applies both heat and a stream of inert gas to the sample. The heat causes contaminants to desorb from the surface and the stream of inert gas sweeps them out of the sample tube. It lets you choose the temperature, gas, and flow rate best suited for your sample material and application. Needle valves allow you to introduce the flowing gas slowly to prevent fluidization of samples. SmartPrep 065 The VacPrep 061 offers two methods for removing contaminants. In addition to flowing gas, it provides vacuum to prepare samples by heating and evacuation. This combination allows you to choose the preparation method that is best suited to your material or application. The VacPrep features six degassing stations, and a choice of vacuum or gas flow preparation on each of the six stations. Needle valves are also provided allowing you to introduce the flowing gas or vacuum slowly to prevent fluidization of samples. VacPrep 061 Model 021 LN 2 Transfer System The Model 021 LN 2 Transfer System allows you to transfer liquid nitrogen or liquid argon from a nonpressurized storage Dewar into smaller containers used in laboratory experiments. The system was specifically developed for conveniently filling Dewars for gas adsorption instruments but also can be used for other cryogen applications. The Model 021 can discharge cryogens at adjustable rates up to 3 liters/min. The roller base makes it easy to move the 021 System to the location where the cryogen is needed. The spigot and insulated, flexible hose enable convenient filling and refilling of analysis Dewars. The system can hold liquid nitrogen or liquid argon up to 30 days allowing costefficient use of your cryogen. Additional accessories are available for special applications. To request a quote or additional product information, visit Micromeritics web site at contact your local Micromeritics sales representative or our Customer Service Department at (770)
8 Micromeritics Instrument Corporation 4356 Communications Drive Norcross, GA USA Telephones: U.S.Sales (770) International Sales (770) Fax (770) Micromeritics China - Beijing Office Room No. 1 Building Shi-Hao Ming-Di (Ten-Mansion) No. 81 Zi Zhu Yuan Rd. Hai Dian District Beijing, P.R. CHINA Code: Telephone (86) Fax (86) Micromeritics France S.A. Parc Alata Rue Antoine Laurent Lavoisier F Verneuil en Halatte FRANCE Telephone (+33) (0) Fax (+33) (0) Micromeritics GmbH Avantis Science Park Rutherford 108 D Aachen Telephone (+49) (0) Fax (+49) (0) Micromeritics Ltd. Unit 2, Chestnut House High Street North Dunstable, Bedfordshire LU6 1AT ENGLAND Telephone (+44) (0) Fax (+44) (0) Micromeritics N.V./S.A. Eugene Plaskylaan 140B 1030 Brussels BELGIUM Telephone (+32) (0) Fax (+32) (0) Micromeritics SRL Via W.Tobagi n. 26/ Peschiera Borromeo, Milano ITALY Telephone (+39) (0) Fax (+39) (0) Micromeritics Japan, G.K. 5F Tokatsu Techno Plaza 501, Kashiwanoha Kashiwa, Chiba Japan Telephone (81) Fax (81)
TriStar II Surface Area and Porosity Analyzer
TriStar II Plus TriStar II Surface Area and Porosity Analyzer Analytical Versatility/ High Throughput/ Small Footprint Surface area and porosity are important physical properties that influence the quality
ASAP 2460. Accelerated Surface Area and
ASAP 2460 Accelerated Surface Area and Porosimetry System Analytical Versatility with Superior Throughput ASAP 2460 Accelerated Surface Area and Porosimetry System The ASAP 2460 Surface Area and Porosimetry
Pore size and BET surface area. analysis at your fingertips. SA 3100. Gas Adsorption Analyzer
Pore size and BET surface area analysis at your fingertips. SA 3100 Gas Adsorption Analyzer The History of Beckman Coulter Particle Characterization Introducing The SA 3100 Surface Area and Pore Size Analyzer
PHYSISORPTION DETERMINATIONS
G A S S O R P T I O N A N A L Y S I S PHYSISORPTION DETERMINATIONS Most atoms that make up a solid are bound on all sides by other atoms in the bulk of the solid. The atoms on the surface of the solid,
Texture characteristic of membrane materials ASAP, BET
Texture characteristic of membrane materials ASAP, BET Theory Specific surface (surface area) is used for the characterization of many materials. There are various techniques how measure the specific surface
Surface Area and Porosity
Surface Area and Porosity 1 Background Techniques Surface area Outline Total - physical adsorption External Porosity meso micro 2 Length 1 Å 1 nm 1 µm 1 1 1 1 1 mm macro meso micro metal crystallite 1-1
The PMI Advanced. BET SORPTOMETER BET-201-AELC-2OS Not just products...solutions!
The PMI Advanced BET SORPTOMETER BET-201-AELC-2OS Not just products...solutions! DESCRIPTION The Fully automated equipment is intended for measurement of adsorption characteristics of various gases on
Software. For the 21 CFR Part 11 Environment. The Science and Technology of Small Particles
Software For the 21 CFR Part 11 Environment The Science and Technology of Small Particles 21 CFR Part 11 Solution confirm Software The Code of Federal Regulations Title 21, Part 11, was implemented by
FINESORB-3020. Surface Area. as or more than 0.1-2000m 2 /g. Distribution of Pore 0.35-500nm. Degas & Analysis Up to 12 Degas & 6 Analysis Station
1 FINESORB-3020 Surface Area and Porosimetry Analyzer Finesorb-3020 is Surface Area and Porosimetry Analyzer based on vacuum system from fintec instrument company.you could do the Surface Area analysis,aperture
presented by Neal Leddy CMA Analytical Workshop 2012 SURFACE AREA AND POROSITY
presented by Neal Leddy CMA Analytical Workshop 2012 SURFACE AREA AND POROSITY Adsorption When a gas or vapour phase is brought into contact with a solid, part of it is taken up and remains on the outside
BET Surface Area Analysis of Nanoparticles
OpenStax-CNX module: m38278 1 BET Surface Area Analysis of Nanoparticles Nina Hwang Andrew R. Barron This work is produced by OpenStax-CNX and licensed under the Creative Commons Attribution License 3.0
Analytical Services. Part number Measurement Description. Single-Point BET with Nitrogen 06000-1N. Multi-Point BET With Nitrogen 06000-3N
06000-1N 06000-3N Single-Point BET with Nitrogen Multi-Point BET With Nitrogen Single-point BET specific surface area (P/Po = 0.3) by nitrogen adsorption at 77K. Dynamic flow method unless otherwise requested.
EXPERIMENTAL METHODS IN COLLOIDS AND SURFACES
EXPERIMENTAL METHODS IN COLLOIDS AND SURFACES PARTICLE SURFACE AREA FROM GAS ADSORPTION TYPES OF ADSORPTION Physical adsorption: rapid, depends on adsorbate bulk concentration, multiple molecular layers
Adsorption. December 2014
Adsorption December 2014 1 Nanosized objects have a large surface area Dividing the size of an object by 2... doubles the accessible surface 2 Adsorption Absorption Absorption is a phenomenon that occurs
Pharmaceutical Physical Characterization: Surface Area and Porosity
Whitepaper Authors: Dr John M. Zielinski Intertek Chemicals & Pharmaceuticals, Allentown, USA Dr Lorna Kettle Intertek Chemicals & Pharmaceuticals, Manchester, UK Date: April 2013 Pharmaceutical Physical
Physical Chemistry Practical Course, Oxford University. Determination of the Surface Area of Alumina by Nitrogen Adsorption at 77K (4 points)
Physical Chemistry Practical Course, Oxford University 1.06 Determination of the Surface Area of Alumina by Nitrogen Adsorption at 77K (4 points) What you will do In this experiment you will study the
CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS
CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS Natural gases either from natural production or storage reservoirs contain water, which condense and form solid gas hydrates to block pipeline flow
Heterogeneous Catalysis and Catalytic Processes Prof. K. K. Pant Department of Chemical Engineering Indian Institute of Technology, Delhi
Heterogeneous Catalysis and Catalytic Processes Prof. K. K. Pant Department of Chemical Engineering Indian Institute of Technology, Delhi Module - 03 Lecture 10 Good morning. In my last lecture, I was
Low Temperature Adsorption Versus Pore Size in Activated Carbons
Low Temperature Adsorption Versus Pore Size in Activated Carbons D. Martins 1, I. Catarino 1, D. Lopes 1, I. Esteves 2, J.P. Mota 2, G. Bonfait 1 1 CEFITEC Departamento de Física, Faculdade de Ciências
A New Technique Provides Faster Particle Size Analysis at a Lower Cost Compared to Conventional Methods
A New Technique Provides Faster Particle Size Analysis at a Lower Cost Compared to Conventional Methods Howard Sanders and Akshaya Jena Porous Material Inc. Ithaca, NY The technique described here calculates
ORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
still different technique of assessment.
D E N S I T Y A N A L Y S I S Micromeritics gas pycnometers are being used worldwide to obtain material density measurements. These measurements are necessary in the manufacture of many of today s products.
(S&G 5th ed. Expt 27, 6th, 7th & 8th eds. Expt 26)
Chem 367-2/ Physical Adsorption 63 PHYSICAL ADSORPTION (S&G 5th ed. Expt 27, 6th, 7th & 8th eds. Expt 26) The sample used in this experiment needs to be conditioned for at least two hours before the experiment;
Micromeritics BET Surface Area and Porosity Analyzer Instrument Information and Generalized Standard Operating Procedure
Micromeritics BET Surface Area and Porosity Analyzer Instrument Information and Generalized Standard Operating Procedure Micromeritics ASAP 2020 Surface Area & Porosity Analyzer Location: W108 Plant Science
This document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 18852 Third edition 2015-06-01 Rubber compounding ingredients Determination of multipoint nitrogen surface area (NSA) and statistical thickness surface area (STSA) Ingrédients
Some generalization of Langmuir adsorption isotherm
Internet Journal of Chemistry, 2000, 3, 14 [ISSN: 1099-8292]. Article 14 Some generalization of Langmuir adsorption isotherm Leszek Czepirski, Mieczyslaw R. Balys, Ewa Komorowska-Czepirska University of
ISO 12800 INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 12800 First edition 2003-12-01 Nuclear fuel technology Guide to the measurement of the specific surface area of uranium oxide powders by the BET method Technologie du combustible
Effect of surface area, pore volume and particle size of P25 titania on the phase transformation of anatase to rutile
Indian Journal of Chemistry Vol. 48A, October 2009, pp. 1378-1382 Notes Effect of surface area, pore volume and particle size of P25 titania on the phase transformation of anatase to rutile K Joseph Antony
Standard Test Methods for Carbon Black Surface Area by Multipoint B.E.T. Nitrogen Adsorption 1
Designation: D 4820 99 Standard Test Methods for Carbon Black Surface Area by Multipoint B.E.T. Nitrogen Adsorption 1 This standard is issued under the fixed designation D 4820; the number immediately
Description of Thermal Oxidizers
Description of Thermal Oxidizers NESTEC, Inc. is a full service equipment supplier specializing in solutions for plant emission problems. The benefit in working with NESTEC, Inc. is we bring 25+ years
SYLOBEAD Adsorbents. for Natural Gas Processing. Introduction. Therefore, it is often necessary to condition the raw gas to:
SYLOBEAD Adsorbents for Natural Gas Processing TECHNICAL INFORMATION Introduction Natural gas (NG) is a vital component of the world s supply of energy. It is one of the cleanest, safest, and most versatile
MERCURY REMOVAL FROM NATURAL GAS AND LIQUID STREAMS ABSTRACT. Giacomo Corvini, Julie Stiltner and Keith Clark UOP LLC Houston, Texas, USA
MERCURY REMOVAL FROM NATURAL GAS AND LIQUID STREAMS Giacomo Corvini, Julie Stiltner and Keith Clark UOP LLC Houston, Texas, USA n ABSTRACT Mercury is often present in natural gas, petrochemical and some
Motivation Physisorption Chemisorption Outlook
Surface area determination - physisorption and chemisorption Literature: Motivation Physisorption Chemisorption Outlook 1. DIN ISO 9277: BET method 2. DIN 66136: Dispersion measurement of metals 3. DIN
Fiscal Measurement Natural Gas
White Paper FSG-WP-0012 February 2014 Fiscal Measurement Natural Gas Fiscal Measurement How much? Fiscal Measurement must not be confused with Custody Transfer; in fact, fiscal measurement is a more general
ADSORPTION OF N2 ON SILICA GEL
Chapter 6. Adsorption of N 2 41 6 ADSORPTION OF N2 ON SILICA GEL The purpose of this experiment is to study the adsorption of gases on solid surfaces and to introduce you to some aspects of vacuum technique
Supporting Information
Supporting Information Copyright Wiley-VCH Verlag GmbH & Co. KGaA, 69451 Weinheim, 2013 A Study of Commercial Nanoparticulate g-al 2 O 3 Catalyst Supports Yahaya Rozita, [a] Rik Brydson,* [a] Tim P. Comyn,
RULE 1102. DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE
(Adopted January 6, 1978)(Amended August 3, 1979)(Amended July 11, 1980) (Amended August 3, 1990)(Amended December 7, 1990) (Amended November 17, 2000) RULE 1102. DRY CLEANERS USING SOLVENT OTHER THAN
Lecture 35: Atmosphere in Furnaces
Lecture 35: Atmosphere in Furnaces Contents: Selection of atmosphere: Gases and their behavior: Prepared atmospheres Protective atmospheres applications Atmosphere volume requirements Atmosphere sensors
Facts About. Industrial gases for better injection molding. This article appeared in the trade journal Kunststoffe plast europe, issue 12/2004.
Facts About. Industrial gases for better injection molding. This article appeared in the trade journal Kunststoffe plast europe, issue 12/2004. 2 Industrial gases for better injection molding Gas injection
SPECIFICS ON SURFACE AREA Rebecca Lea Wolfrom
SPECIFICS ON SURFACE AREA Rebecca Lea Wolfrom Surface area is an important property of solids with many industrial applications. Particle size is less influential on surface area than particle shape, texture,
MILESTONE. SynthWAVE. The Game Changer in Microwave Synthesis
MILESTONE H E L P I N G C H E M I S T S SynthWAVE The Game Changer in Microwave Synthesis The new Milestone SynthWAVE is designed for safe, reliable and reproducible scale-up of microwave-enhanced chemical
Fractional Distillation and Gas Chromatography
Fractional Distillation and Gas Chromatography Background Distillation The previous lab used distillation to separate a mixture of hexane and toluene based on a difference in boiling points. Hexane boils
Development of porous materials for hydrogen storage
Development of porous materials for hydrogen storage Shinji Oshima, Osamu Kato, Takeshi Kataoka, Yoshihiro Kobori, Michiaki Adachi Hydrogen & New Energy Research Laboratory Nippon Oil Corporation 8, Chidoricho,
CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA 91342 ABSTRACT
CRYOCOOLER CONTAMINATION STUDY S.W.K. Yuan, D.T.Kuo, and A.S. Loc EI Technologies, Cryocooler Group Sylmar, CA 91342 ASTRACT Eliminating or reduction of contamination is essential for the success of cryocoolers
Molecular Sieve Adsorbents
Adsorption Technologies: our work our life our passion. Molecular Sieve Adsorbents Zeochem Molecular Sieve Adsorbents Zeochem, a manufacturer of high quality molecular sieves and chromatography gels, was
Derivation of the BET and Langmuir Isotherms
Derivation of the BET and Langmuir Isotherms October 5, 2011 1 Langmuir Isotherm Assumptions used for the Langmuir isotherm 1. Gaseous molecules behave ideally 2. Only one monolayer forms 3. All sites
ASimple Guide to Oil Refining
ASimple Guide to Oil Refining We all know that motor oil and gasoline come from crude oil. What many people do not realize is that crude oil is also the starting point for many diverse products such as
Federal Institute for Materials Research and Testing
Federal Institute for Materials Research and Testing CERTIFIED REFERENCE MATERIAL FOR THE GAS ADSORPTION BAM-PM-101 Material: SiO 2 with specific surface area (BET) of 0.177 0.004 m² g -1 Mean of means
Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2
Instruction Manual Dew Point Tester The CVS Dew Point Tester is a chilled mirror apparatus, which operates by attaining the conditions necessary by the definition of dew point. When a gas is cooled out
Vacuum Pumping of Large Vessels and Modelling of Extended UHV Systems
Vacuum Pumping of Large Vessels and Modelling of Extended UHV Systems Georgy L. Saksaganski D.V. Efremov Institute, St Petersburg, Russia [email protected] An overview of the methods for reducing of
EXTENDING MOLECULAR SIEVE LIFE IN NATURAL GAS DEHYDRATION UNITS
EXTENDING MOLECULAR SIEVE LIFE IN NATURAL GAS DEHYDRATION UNITS Henry (Hank) Rastelli UOP LLC, a Honeywell Company Des Plaines, IL, USA Julie Stiltner Shadden UOP LLC, a Honeywell Company Houston, TX,
LNG Fuel Tank System LNG Tank overview
Index 1. LNG Tank Overview 2. 3. Gas Flow Diagram 4. Tank Operation 5. 6. Maintenance Boil off line Slave tank Master tank manual gas line vacuum control manual liquid line Check nonreturn filling line
G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method
G8 GALILEO High-End Melt-extraction Analyzer Innovation with Integrity Inert Gas Method Determination of O, N and H The market demands Metals, minerals, and inorganic compound markets demand high-quality
GRANULAR ACTIVATED CARBON FOR WATER & WASTEWATER TREATMENT
GRANULAR ACTIVATED CARBON FOR WATER & WASTEWATER TREATMENT CARBTROL Corporation September 1992 Rev. 10/92 TP-3 INTRODUCTION Carbon has been used as an adsorbent for centuries. Early uses of carbon were
Chapter 7: Oil Vapor Diffusion Pumps
Chapter 7: Oil Vapor Diffusion Pumps It wasn't that long ago when you could walk into any vacuum laboratory and find a vapor diffusion pump on every system. Vapor diffusion pumps were first conceived about
Characterization of Gas Shale Pore Systems by Analyzing Low Pressure Nitrogen Adsorption
Characterization of Gas Shale Pore Systems by Analyzing Low Pressure Nitrogen Adsorption Presented by: Mehdi Labani PhD student in Petroleum Engineering Supervisor: Reza Rezaee September 212 Objective
Chromatograph Maintenance and Troubleshooting Class # 5050
Chromatograph Maintenance and Troubleshooting Class # 5050 Shane Hale Business Development Manager Emerson Process Management Gas Chromatographs Division 5650 Brittmoore Drive Houston, TX 77041 USA Introduction
Appendix A. Fig. 1 Nitrogen adsorption for Activated Carbon from Norit
Appendix A Summary Report Surface Area BET Surface Area: 1555.9551 m²/g Langmuir Surface Area: 1992.1415 m²/g Pore Volume Single point adsorption total pore volume of pores 0.619747 cm³/g t-plot micropore
Hydrogen Adsorption on Nanoporous Biocarbon
Hydrogen Adsorption on Nanoporous Biocarbon Mikael Wood, Jacob Burress, Cintia Lapilli, Peter Pfeifer, Parag Shah, Galen Suppes University of Missouri-Columbia Phillip Parilla, Anne Dillon National Renewable
Characterization and Quantification of Lyophilized Product Appearance and Structure
Characterization and Quantification of Lyophilized Product Appearance and Structure Dr Kevin R. Ward B.Sc. Ph.D. MRSC Director of Research & Development Biopharma Technology Ltd. Winchester SO23 0LD, UK
Nano-pore structure characterization of shales using gas adsorption and mercury intrusion techniques
Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 2014, 6(4):850-857 Research Article ISSN : 0975-7384 CODEN(USA) : JCPRC5 Nano-pore structure characterization of shales using
CHARACTERIZATION OF POROUS GLASS
2.1. Introduction The characterisation of amorphous networked materials is problematic because the structure of the materials is enormously complex, and a "complete'' characterisation requires no less
Oil Analysis. It is important that the sampling be done in the following manner: 1.
Oil Analysis Introduction Oil analysis was originally used by the military and the railroad as a preventative maintenance program. It has expanded today to the fi eld of study called Tribology. Oil analysis
THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles
THERMAL DESORPTION Introduction and Principles Thermal Desorption Thermal desorption is a simple extension of the technique of gas chromatography (GC) It involves the use of heat and a flow of inert gas
Surface Parameters of Stannic Oxide in Powder, Ceramic and Gel Forms by Nitrogen Adsorption Techniques l
PHYSICAL SCIENCES 137 Surface Parameters of Stannic Oxide in Powder, Ceramic and Gel Forms by Nitrogen Adsorption Techniques l JAMES L. RUTLEDGE, Department of Physics OIdahoma State University, StlUwater
Natural Gas Information Contents
Natural Gas Information Contents What is natural gas Natural Gas Components Physical Properties of Natural Gas Different Forms of Natural Gas The Use of Natural Gas Co-generation System Natural Gas and
On-line Dissolved Gas Analysis
On-line Dissolved Gas Analysis accord. to IEC 567/ASTM 3612 Online-Monitoring of transformers Automatic on-line analysis of 11 gases The analysis is done in 2 steps with high selectivity and accuracy fully
Experimental Study of Micropore Size Distribution in Coals
2012 International Conference on Fluid Dynamics and Thermodynamics Technologies (FDTT 2012) IPCSIT vol.33(2012) (2012) IACSIT Press, Singapore Experimental Study of Micropore Size Distribution in Coals
EcoCWave. The all-round talent for aqueous part cleaning. www.durr.com
EcoCWave The all-round talent for aqueous part cleaning www.durr.com Part cleaning as a value-adding value-adding process process Increasing demands on cleanliness in component manufacturing impose a need
Standard Operating Procedure
Page 1 of 6 SCHLENK LINE Standard Operating Procedure Lab: Engineering Sciences Building 155 Department: Materials Science and Engineering PI: Paul V. Braun Written By: Christian Ocier Section 1: Overview
Use the BET (after Brunauer, Emmett and Teller) equation is used to give specific surface area from the adsorption
Number of moles of N 2 in 0.129dm 3 = 0.129/22.4 = 5.76 X 10-3 moles of N 2 gas Module 8 : Surface Chemistry Objectives Lecture 37 : Surface Characterization Techniques After studying this lecture, you
Cryogenic Vacuum Pumps
Oxford Instruments Austin Cryogenic Vacuum Pumps Decontamination Procedure Only use helium gas with at least 99.999% purity for decontamination procedure described in this document. Decontamination procedures
Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.
Gas Chromatography Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC. Samples in 10mL sealed glass vials were placed in the MPS-2
Propane and Natural Gas Safety
Rialto Fire Department Fire and Life Safety Tips August 2010 Propane and Natural Gas Safety If you smell Propane or Natural Gas leave area immediately and call 911 U.S. fire departments responded to an
UOP Adsorbents COMPREHENSIVE PORTFOLIO TO REMOVE CONTAMINANTS FROM A VARIETY OF SOURCES. UOP Adsorbent Solutions
UOP Adsorbents COMPREHENSIVE PORTFOLIO TO REMOVE CONTAMINANTS FROM A VARIETY OF SOURCES UOP Adsorbent Solutions When you invest in UOP Adsorbents, you gain more than simply a contaminant removal product.
THE HUMIDITY/MOISTURE HANDBOOK
THE HUMIDITY/MOISTURE HANDBOOK Table of Contents Introduction... 3 Relative Humidity... 3 Partial Pressure... 4 Saturation Pressure (Ps)... 5 Other Absolute Moisture Scales... 8 % Moisture by Volume (%M
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Batch coater For exceptional product quality
Batch coater For exceptional product quality www.andritz.com/ft Batch coating system with or without vacuum potentially opens the door to the production of entirely new categories of products in the future.
MATHESON REFINERY PROGRAM for Specialty Gas Supply. Experience the MATHESON Commitment to Supply Chain Excellence
MATHESON REFINERY PROGRAM for Specialty Gas Supply MATHESON REFINERY PROGRAM for Specialty Gas Supply MATHESON is a single source for industrial, medical, specialty, and electronics gases as well as gas
RISK ASSESMENT: HANDLING, TRANSPORTATION AND STORAGE OF LIQUID NITROGEN AND OTHER CRYOGENIC MATERIAL
RISK ASSESMENT: HANDLING, TRANSPORTATION AND STORAGE OF LIQUID NITROGEN AND OTHER CRYOGENIC MATERIAL More information can be found in the liquid nitrogen section of the departmental Health & Safety webpages:
POLLUTED EMISSION TREATMENTS FROM INCINERATOR GASES
POLLUTED EMISSION TREATMENTS FROM INCINERATOR GASES Ecole Nationale Supérieure de Chimie Avenue du Général Leclerc, Campus de Beaulieu 35700 Rennes, France Tel 33 (0)2 23 23 80 02 Fax 33 (0)2 23 23 81
Lecture 7 Heat Transfer & Thermal Insulation. J. G. Weisend II
Lecture 7 Heat Transfer & Thermal Insulation J. G. Weisend II Goals Introduce conduction, convection & radiation heat transfer as they apply to cryogenics Describe design techniques to reduce heat transfer
Car and commercial cial air conditioning service solutions
Car and commercial cial air conditioning service solutions THE STANDARD IN INFORMATION AND DIAGNOSTICS SYSTEMS INTRODUCTION For the KoolKare range of vehicle air conditioning service equipment we went
Module 1: History of Fuels. Lecture 6: Fundamental definitions, properties and various measurements
1 P age Module 1: History of Fuels Lecture 6: Fundamental definitions, properties and various measurements 2 P age Keywords: Characterisation, analytical methods, standards 1.3 Fundamental definitions,
Sterilization methods and equipment Lab 1-2
Sterilization methods and equipment Lab 1-2 PHT 434 Sterilization Sterilization a process that by which all viable M.O are removed or destroyed, based on a probability function. Sterilization concept Sterilization
INSIGHTS ON CARBON BLACK FUNDAMENTALS
INSIGHTS ON CARBON BLACK FUNDAMENTALS History Carbon black is one of the oldest manufactured materials. Early uses can be traced back to ancient China, the early Egyptians and the production of Indian
Flushing and Cleaning the A/C System
Flushing and Cleaning the A/C System Once an AC system has been contaminated or has suffered a failure, the most important part of the AC service to restore the cooling performance to the system = FLUSHING
Integrated Custom Systems
Integrated Custom Systems Compact panels Standard Manifolds & Assemblies Electronic pressure control Custom manifolds & Assemblies Automated test benches S t r e a m l i n e y o u r p r o c e s s Complete
BTU ANALYSIS USING A GAS CHROMATOGRAPH
BTU ANALYSIS USING A GAS CHROMATOGRAPH By Joseph E. Landes Southern Petroleum Laboratories, Inc. Technical Director Hydrocarbon and Field Services 8820 Interchange Drive Houston, Texas 77054 Introduction
Process gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja
Process gas chromatographs. Measurement made easy Compliance Solutions for 40CFR60 Subpart Ja Introduction ABB offers a proven analytical solution to completely meet your Refinery Flare Monitoring requirements
INSTALLATION AND OPERATION OF AUTOSORB-l-C-8 FOR BET SURFACE AREA MEASUREMENT OF POROUS MATERIALS
PINSTECH-221 INSTALLATION AND OPERATION OF AUTOSORB-l-C-8 FOR BET SURFACE AREA MEASUREMENT OF POROUS MATERIALS Abdul Sattar Ali Khan Chemistry Division Directorate of Science Pakistan Institute of Nuclear
Chapter Test A. States of Matter MULTIPLE CHOICE. a fixed amount of STAs2 a. a solid. b. a liquid. c. a gas. d. any type of matter.
Assessment Chapter Test A States of Matter MULTIPLE CHOICE Write the letter of the correct answer in the space provided. 1. Boyle s law explains the relationship between volume and pressure for a fixed
Dehydration. Dehydration UNIT. operations. bioprocess plants
Dehydration Dehydration UNIT operations bioprocess plants VOGELBUSCH MOLECULAR SIEVE DEHYDRATION PRESSURE SWING ADSORPTION PROCESS By merging specialized process know-how with existing technology Vogelbusch
Wire, cable and pipe extrusion
Marking, coding and systems solutions Wire, cable and pipe extrusion We know the unique challenges you face on your production lines More than any other industry, wire, cable or pipe production demands
TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System
TECHNICAL SPECIFICATION StirLIN-1 Economy Liquid Nitrogen System Reference 80 8120_01 Issue Date August 1, 2015 1. INTRODUCTION Since more than sixty years Stirling Cryogenics has designed and manufactured
1.3 Properties of Coal
1.3 Properties of Classification is classified into three major types namely anthracite, bituminous, and lignite. However there is no clear demarcation between them and coal is also further classified
CHAMELEON THERMOCHROMIC UV FLEXO INK
LCR Hallcrest Ltd. Riverside Buildings, Dock Road, Connah s Quay, Flintshire, CH5 4DS U.K. Tel: +44 (0)1244 817107 Fax: +44 (0)1244 818502 Email: [email protected] Web: www.lcrhallcrest.com Advanced
The photoionization detector (PID) utilizes ultraviolet
Chapter 6 Photoionization Detectors The photoionization detector (PID) utilizes ultraviolet light to ionize gas molecules, and is commonly employed in the detection of volatile organic compounds (VOCs).
We will try to get familiar with a heat pump, and try to determine its performance coefficient under different circumstances.
C4. Heat Pump I. OBJECTIVE OF THE EXPERIMENT We will try to get familiar with a heat pump, and try to determine its performance coefficient under different circumstances. II. INTRODUCTION II.1. Thermodynamic
