Technical Data. Dimensions



Similar documents
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Technical Data. Dimensions

Inductive slot sensor

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Inductive sensor NI10-M18-Y1X-H1141

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Solenoid Valve Island Type 3965

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Control- and feedback head for integrated mounting on Robolux valves Type 2036

A good connection. International approvals.

Plug and Socket Devices SolConeX 16 A Series 8570

2.12. page Products for Explosion hazardous Environment

Plug and Socket Devices CES 63 A Series 8579

Safety instructions VEGADIS DIS81.CEIA/V****

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

SEISMIC VELOCITY TRANSDUCER T1-40

Series 8146/5-V37 and Series 8150/5-V37

Relative pressure transmitter type 520

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Instructions for Safe Use

Terminal Box. Specifications TNCN

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Inductive sensors. Compact, fast, reliable. Edition 2013

CAPACITIVE LEVEL METERS CLM 36

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Technical Information RIA14

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Explosion proof enclosures

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

TTF300 Field-mount temperature transmitter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Design of intrinsically safe systems

MINI MCR-SL-R-UI(-SP)

Electronic Pressure Switch EDS 300

Thermistor motor protection

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Terminal Boxes Series 8146

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

Flow switches Series AD/VH

Safety instructions VEGAPULS PSWL61. KX***H***

SAFETY MANUAL SIL Switch Amplifier

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Pressure transmitter For general industrial applications Model A-10

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Magnetic proximity switches

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Plastic tube flowmeters Series PT/PS

Electric Rotary Actuator - On/Off or programmable control actuator

Cable Plug acc. to DIN EN , Form A

Compact pressure switch Flameproof enclosure Ex d Model PCA

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

distributing & controlling system solutions

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Three-phase monitoring relay CM-PFE

Differential-Hall-Effect based Sensors Series A5S Overview

Technical data sheet TDS0070

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Capacitive Prox E2K-X

Digital input modules

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Linear Luminaire with LED Series EXLUX 6402/2

Worcester DS/DM Series UltraSwitch Switch box

3DLevelScanner II TECHNICAL DATA SHEET

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Wolflite Safety Handlamp H-251E

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

How To Read A Pipe From A Sensor

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

UM-X Field display for continous level sensors

Transcription:

0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 15 mm Installation quasi flush Output polarity NAMUR Assured operating distance s a 0... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Nominal ratings Nominal voltage U o 8 V Switching frequency f 0... 450 Hz Hysteresis H 1... 15 typ. 5 % Reverse polarity protection reverse polarity protected Short-circuit protection yes Current consumption Measuring plate not detected 2.2 ma Measuring plate detected 1 ma Switching state indicator Multihole-LED, yellow Functional safety related parameters MTTF d 3068 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Ambient conditions Ambient temperature -25... 100 C (-13... 212 F) Storage temperature -40... 100 C (-40... 212 F) Mechanical specifications Connection type Connector M12 x 1, 4-pin Core cross-section - Housing material Stainless steel 1.4305 / AISI 303 Sensing face PBT Degree of protection IP67 information Use in the hazardous area see instruction manuals Category 1G; 2G; 3G; 3D Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibility NE 21:2007 Standards EN 60947-5-2:2007 IEC 60947-5-2:2007 Approvals and certificates FM approval Control drawing 116-0165F UL approval culus Listed, Purpose CSA approval ccsaus Listed, Purpose CCC approval CCC approval / marking not required for products rated 36 V Dimensions M30x1,5 40 5 36 LED M12x1 6 45 55 1

Electrical Connection 1 L+ 2 L- Wire colors in accordance with EN 60947-5-6 1 BN 2 BU (brown) (blue) Installation Hint Installation conditions Metal B A A = 5 mm B = 15 mm 2

ATEX 1G Device category 1G for use in hazardous areas with gas, vapour and mist EC-Type Examination Certificate PTB 00 ATEX 2048 X II 1G Ex ia IIC T6 T1 Ga Standards EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007 Ignition protection "Intrinsic safety" Appropriate type NCB15-30GM...-N0... Effective internal capacitance C i 120 nf ; a cable length of 10 m is considered. Effective internal inductance L i 150 µh ; a cable length of 10 m is considered. The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Directive and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 C was tested with regard to hot surfaces by the mentioned certification authority. If the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. Ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Note: Use the temperature table for category 1!!! The 20 % reduction in accordance with EN 1127-1:2007 has already been accounted for in the temperature table for category 1. Laws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Due to the possible danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation of the power supply and signal circuit is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. When used in group IIC non-permissible electrostatic charges should be avoided on the plastic housing parts. Additional requirements for gas group IIC. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. 3

ATEX 2G Device category 2G for use in hazardous areas with gas, vapour and mist EC-Type Examination Certificate PTB 00 ATEX 2048 X II 1G Ex ia IIC T6 T1 Ga Standards EN 60079-0:2012, EN 60079-11:2012 Ignition protection "Intrinsic safety" Appropriate type NCB15-30GM...-N0... Effective internal capacitance C i 120 nf ; a cable length of 10 m is considered. Effective internal inductance L i 150 µh ; a cable length of 10 m is considered. The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Directive and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. The use in ambient temperatures of > 60 C was tested with regard to hot surfaces by the mentioned certification authority. If the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. Ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Laws and/or regulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. 4

ATEX 3G (nl) Note This instruction is only valid for products according to EN 60079-15:2005, valid until 01-May-2013 Device category 3G (nl) for use in hazardous areas with gas, vapour and mist Standard conformity Effective internal capacitance C i Effective internal inductance L i Maximum permissible ambient temperature T Umax at Ui = 20 V for Pi=34 mw, Ii=25 ma, T6 for Pi=34 mw, Ii=25 ma, T5 for Pi=34 mw, Ii=25 ma, T4-T1 for Pi=64 mw, Ii=25 ma, T6 for Pi=64 mw, Ii=25 ma, T5 for Pi=64 mw, Ii=25 ma, T4-T1 for Pi=169 mw, Ii=52 ma, T6 for Pi=169 mw, Ii=52 ma, T5 for Pi=169 mw, Ii=52 ma, T4-T1 for Pi=242 mw, Ii=76 ma, T6 for Pi=242 mw, Ii=76 ma, T5 for Pi=242 mw, Ii=76 ma, T4-T1 Protection from UV light Protection of the connection cable Connection parts II 3G Ex nl IIC T6 X The Ex-significant identification is on the enclosed adhesive label EN 60079-15:2005 Ignition protection category "n" 120 nf ; a cable length of 10 m is considered. 150 µh ; A cable length of 10 m is considered. The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! Laws and/or regulations and standards governing the use or intended usage goal must be observed. The sensor must only be operated with an energy-limited circuit, which satisfies the requirements of IEC 60079-15. The explosion group complies with the connected, supplying, power limiting circuit. The adhesive label provided must be affixed in the immediate vicinity of the sensor! The surface to which the label is applied must be clean, flat and free from grease! The affixed adhesive label must be readable and durable, taking account of the possibility of chemical corrosion! The sensor must not be exposed to ANY FORM of mechanical danger. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. The connection cable must be prevented from being subjected to tension and torsional loading. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. The connection parts are to be installed, such that a minimum protection class of IP20 is achieved, in accordance with IEC 60529. 5

ATEX 3G (ic) Device category 3G (ic) Certificate of Compliance CE marking Standards Effective internal capacitance C i Effective internal inductance L i Maximum permissible ambient temperature T Umax at Ui = 20 V for Pi=34 mw, Ii=25 ma, T6 for Pi=34 mw, Ii=25 ma, T5 for Pi=34 mw, Ii=25 ma, T4-T1 for Pi=64 mw, Ii=25 ma, T6 for Pi=64 mw, Ii=25 ma, T5 for Pi=64 mw, Ii=25 ma, T4-T1 for Pi=169 mw, Ii=52 ma, T6 for Pi=169 mw, Ii=52 ma, T5 for Pi=169 mw, Ii=52 ma, T4-T1 for Pi=242 mw, Ii=76 ma, T6 for Pi=242 mw, Ii=76 ma, T5 for Pi=242 mw, Ii=76 ma, T4-T1 Connection parts for use in hazardous areas with gas, vapour and mist PF 13 CERT 2895 X II 3G Ex ic IIC T6 T1 Gc The Ex-significant identification is on the enclosed adhesive label EN 60079-0:2012, EN 60079-11:2012 Ignition protection category "ic" 120 nf ; a cable length of 10 m is considered. 150 µh ; A cable length of 10 m is considered. The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! Laws and/or regulations and standards governing the use or intended usage goal must be observed. The sensor must only be operated with energy-limited circuits, which satisfy the requirements of IEC 60079-11. The explosion group depends on the connected and energy-limited supply circuit. The adhesive label provided must be affixed in the immediate vicinity of the sensor! The surface to which the label is applied must be clean, flat and free from grease! The affixed adhesive label must be readable and durable, taking account of the possibility of chemical corrosion! The sensor must not be mechanically damaged. When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. The connection parts are to be installed, such that a minimum protection class of IP20 is achieved, in accordance with IEC 60529. 6

ATEX 3D Note This instruction is only valid for products according to EN 50281-1-1, valid until 30-September-2008 Note the ex-marking on the sensor or on the enclosed adhesive label Device category 3D for use in hazardous areas with non-conducting combustible dust II 3D IP67 T 111 C (231.8 F) X The Ex-significant identification is on the enclosed adhesive label Standards EN 50281-1-1 Protection via housing The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to! Laws and/or regulations and standards governing the use or intended usage goal must be observed. The adhesive label provided must be affixed in the immediate vicinity of the sensor! The surface to which the label is applied must be clean, flat and free from grease! The affixed adhesive label must be readable and durable, taking account of the possibility of chemical corrosion! Minimum series resistance R V A minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier. Maximum operating voltage U Bmax The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted. Maximum heating (Temperature rise) Values can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv. at U Bmax =9 V, R V =562 Ω 11 K using an amplifier in accordance with 11 K EN 60947-5-6 The sensor must not be mechanically damaged. Plug connector s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. The plug connector must not be disconnected under voltage. The proximity switch is marked as follows: DO NOT DISCON- NECT UNDER VOLTAGE! When the plug connector is disconnected the ingress of dirt into the inner areas (i.e. the areas, which are not accessible in the plugged-in condition) must be prevented. The plug connection can only be separated using a tool. This is achieved by using the locking protection V1-Clip (Mounting accessory from Pepperl + Fuchs). 7

ATEX 3D (td) Note This instruction is only valid for products according to EN 61241-0:2006 and EN 61241-1:2004 Note the ex-marking on the sensor or on the enclosed adhesive label Device category 3D for use in hazardous areas with non-conducting combustible dust II 3D Ex td A22 IP67 T80 C X The Ex-relevant identification may also be printed on the accompanying adhesive label. Standards EN 61241-0:2006, EN 61241-1:2004 Protection via housing "td" The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The maximum surface temperature has been determined in accordance with method A without a dust layer on the equipment. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to! The statutory requirements, directives and standards applicable to the intended use and application must be observed. The adhesive label provided must be affixed in the immediate vicinity of the sensor! The surface to which the label is applied must be clean, flat and free from grease! The affixed adhesive label must be readable and durable, taking account of the possibility of chemical corrosion! Minimum series resistance R V Maximum operating voltage U Bmax Maximum permissible ambient temperature T Umax at U Bmax =9 V, R V =562 Ω using an amplifier in accordance with EN 60947-5-6 Protection from UV light Plug connector A minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance with the following list. This can also be assured by using a switch amplifier. The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted. Values can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv. 58 C (136.4 F) 58 C (136.4 F) The sensor must not be exposed to ANY FORM of mechanical danger. The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. The plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: "WARNING - DO NOT SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e. the area that is inaccessible when the connector is inserted) The plug connection can only be separated using a tool.this is achieved by using the locking protection V1-Clip (Mounting accessory from Pepperl + Fuchs). 8