United Kingdom en. ErP information. Gas fired condensing boiler Gas 210 ECO PRO



Similar documents
GAS 610 ECO PRO. The new Remeha. Condensing Boiler Range REMEHA GAS 310/610 ECO PRO

A BIG STEP IN REDUCING YOUR CARBON FOOTPRINT.

Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

For installation guide see reverse of book

ELECTRIC CENTRAL HEATING FLOW BOILER

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

ELECTRIC INSTANTANEOUS WATER HEATER

ONE STAGE LIGHT OIL AND KEROSENE BURNERS

User manual and Installation instructions

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

EcoDesign & Labelling Directive (ErP)

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Gas Instantaneous Water Heater

Continuous flow direct water heating for potable hot water

HEAVY DUTY STORAGE GAS


User's Instructions. Alpha HE CB25/33 and HE SY25

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

User Guide. Promax System Condensing System Boiler

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Operating instructions

User Guide. EcoBlue Advance Heat Gas Fired Wall Mounted Condensing Boiler

Meaco 30L and Meaco 40L dehumidifier instruction manual

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Baxi Combi 80e & 105e

ADM1TE 5/30A DIN rail single phase two wire energy meter

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

Daikin Altherma. hybrid heat pump. The natural combination

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Daikin Altherma hybrid heat pump. The natural combination

MODULATING LIGHT OIL BURNERS RL/M SERIES

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50/16LP50, 16NG60/16LP60, 20NG50/20LP50, 20NG60/20LP60, 26NG50/26LP50, 26NG60/26LP60

G670 Intermittent Pilot Ignition Controls

Aludesign K A T A L O G

Oil - kerosene burners

High kw Electric Tankless Water Heater Troubleshooting Guide

V94 BULK TAPE DEGAUSSER

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Your safety and the safety of others are very important.

Service manual. ActivA

Service Manual REU - 16 FUA - E. Infinity 16 i. Continuous Flow Water Heater. Important.

San josé OWNER S MANUAL

Quinta Pro

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

E-gas Instant Gas Water Heaters

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

orlando OWNER S MANUAL

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Factory owners must ensure the boiler is:

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

The Concept of Condensing Boilers

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K

Service Manual Models: 502, 752, 1002, 1302,

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

Working towards a cleaner future. 30 to 4000kW. Condensing Aluminium 30 to 600kW. Condensing Stainless Steel 50 to 160kW

UDSA - UDSBD unit heater

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

User Guide. Main Heat Condensing Central Heating Boiler

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers

Installation and Service Manual. Duo-tec Combi LPG. Gas Fired Wall Mounted Condensing Combination Boiler

User Manual. Gas fired condensing wall hung boiler. G.C.N : (12 kw) G.C.N : (18 kw) G.C.N : (24 kw)

FT-100 Fire Training Fog Machine User Manual English

Operating instructions

/2010 US/CA

BFC. High Efficient Condensing Water Heater BFC - 28/30/50/60/80/100/120. Installation, User and Service Manual. Innovation has a name.

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Overheating limit control

AGA GAS MARK 2 BURNER (CONVERSION) FITTING INSTRUCTIONS

user manual smappee monitor

User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler

Aerona Air Source Heat Pumps

SECURITY SYSTEM ADP-CAN

User manual. 086U6297 Rev. 9 EN

SL280UHV SERIES GAS FURNACE WARNING

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

=============================== WARNING

Rheem Spare Parts Manual. Commercial gas model A Exterior 265L

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

1 DESCRIPTION OF THE APPLIANCE

Installation and Servicing Instructions

Installation and Service Manual. Promax Combi Condensing Combination Boiler

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Service Manual Models:

Addendum to the Operating Instructions

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

ONE STAGE GAS BURNERS RIELLO 40 FS SERIES FS kw FS kw FS kw FS kw FS kw

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

INSTALLATION GUIDE 1

WORKING DOCUMENT ON. Possible requirements for air heating products, cooling products and high temperature process chillers TRANSITIONAL METHODS

Service Manual Models:

Online UPS. PowerWalker VFI 1000R/1U

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

Transcription:

United Kingdom en ErP information Gas fired condensing boiler Gas 210 ECO PRO

Dear customer, Thank you for purchasing this appliance. Please read this manual carefully before using the product and keep it in a safe place for future reference. In order to ensure continued safe and efficient operation we recommend that the product is regularly maintained. Our Service and After Sales organization can assist with this. We hope you will receive many years of satisfactory service. Remeha B.V. Postbus 32 7300 AA Apeldoorn T +31 (0)55 549 6969 I http://nl.remeha.com E remeha@remeha.com

Contents Contents 1 Safety............................................................................................ 4 1.1 Recommendations............................................................................. 4 2 About this manual................................................................................... 6 2.1 Symbols used................................................................................. 6 2.1.1 Symbols used in the manual.............................................................. 6 2.2 Afkortingen................................................................................... 6 3 Technical specifications.............................................................................. 7 3.1 Homologations................................................................................ 7 3.1.1 Unit categories.........................................................................7 3.2 Technical data.................................................................................7 3.3 Electrical diagram............................................................................. 10 4 Commissioning.................................................................................... 12 4.1 Gas settings................................................................................. 12 4.1.1 Adaptation to a different gas type......................................................... 12 4.1.2 Checking/setting the combustion..........................................................12 5 Settings.......................................................................................... 15 5.1 Parameter descriptions......................................................................... 15 5.2 Displaying the measured values.................................................................. 15 5.2.1 Status and sub-status.................................................................. 15 6 Disposal/recycling.................................................................................. 17 6.1 Removal/recycling.............................................................................17 7 Appendix......................................................................................... 18 7.1 ErP information............................................................................... 18 7.1.1 Product card......................................................................... 18 7.2 Optional electrical connections................................................................... 18 7.2.1 Connection options for the PCB (SCU-X03)................................................. 18 7638135 - v.02-13082015 3

1 Safety 1 Safety 1.1 Recommendations Danger This appliance must not be used by people (and children) with a physical, sensory or mental disability, or by people with a lack of technical experience, unless they are supervised by someone who can assure their safety, or they have been instructed in the correct use of the appliance. Do not allow children to play with the appliance. Warning Installation and maintenance of the boiler must be carried out by a qualified installer in accordance with local and national regulations. Warning Only qualified persons are authorised to assemble, install and maintain the installation. Warning Removal and disposal of the boiler must be carried out by a qualified installer in accordance with local and national regulations. Warning If the mains lead is damaged, it must be replaced by the original manufacturer, the manufacturer's dealer or another suitably skilled person to prevent hazardous situations from arising. Warning Always disconnect the mains supply and close the main gas tap when working on the boiler. Warning Check the entire system for leaks after maintenance and servicing work. Caution Make sure the boiler can be reached at all times. The boiler must be installed in a frost-free area. If the power cord is permanently connected, you must always install a main bipolar switch with an opening gap of at least 3 mm (EN 60335-1). Drain the boiler and central heating system if you are not going to use your home for a long time and there is a chance of frost. The frost protection does not work if the boiler is out of operation. The boiler protection only protects the boiler, not the system. Check the water pressure in the system regularly. If the water pressure is lower than 0.8 bar, the system must be topped up (recommended water pressure between 1.5 and 2 bar). Keep this document near to the boiler. Casing panels may only be removed for maintenance and servicing purposes. Refit all panels when maintenance work and servicing are complete. 4 7638135 - v.02-13082015

1 Safety Instruction and warning labels must never be removed or covered and must be clearly legible throughout the entire service life of the boiler. Replace damaged or illegible instruction and warning labels immediately. Modifications to the boiler require the written approval of Remeha. 7638135 - v.02-13082015 5

2 About this manual 2 About this manual 2.1 Symbols used 2.1.1 Symbols used in the manual This manual uses various danger levels to draw attention to special instructions. We do this to improve user safety, to prevent problems and to guarantee correct operation of the appliance. Danger Risk of dangerous situations that may result in serious personal injury. Danger of electric shock Risk of electric shock. Warning Risk of dangerous situations that may result in minor personal injury. Caution Risk of material damage. Please note: important information. See Reference to other manuals or pages in this manual. 2.2 Afkortingen PCU SCU SU PCB for managing burner operation Control panel PCB Safety PCB 6 7638135 - v.02-13082015

3 Technical specifications 3 Technical specifications 3.1 Homologations 3.1.1 Unit categories Category Gas type Connection pressure (mbar) II 2H3P G20 (H gas) G31 (propane) 20 37-50 3.2 Technical data Tab.1 General Gas 210 ECO PRO 210-80 210-120 210-160 210-200 Nominal output (Pn) Central heating operation (80/60 C) Nominal output (Pn) Central heating operation (50/30 C) Nominal input (Qn) Central heating operation (Hi) Nominal input (Qn) Central heating operation (Hs) Full load central heating efficiency (Hi) 80 C/60 C (92/42 EEC) Full load central heating efficiency (Hi) 50/30 C (EN15502) Central heating efficiency under part load (Hi) (Return temperature 60 C) Part load central heating efficiency (92/42 EEC) (Return temperature 30 C) (1) Factory setting min-max (1) min-max (1) min-max (1) min-max (1) kw 16-87 87 kw 18-93 93 kw 17-89 89 kw 19-99 99 22-115 115.0 24-129 129 23-123 123 26-137 137 29-166 166 33-179 179 31-170 170 34-189 189 39-200 200 44-217 217 41-205 205 46-228 228 % 97.43 97.5 97.54 97.6 % 104.3 104.7 105.2 105.7 % 92.7 94.0 95.1 95.5 % 108.6 108.3 108.1 108.4 Tab.2 Gas and flue gas data Gas 210 ECO PRO 210-80 210-120 210-160 210-200 Gas inlet pressure G20 (H gas) min-max mbar 17-25 17-25 17-25 17-25 Gas inlet pressure G31 (propane) min-max mbar 37-50 37-50 37-50 37-50 Gas consumption G20 (H gas) min-max m 3 /h 1.8-9.4 2.4-13 3.3-18 4.3-21.7 Gas consumption G31 (propane) min-max m 3 /h 1.0-3.6 1.0-4.8 1.6-7.0 1.8-8.4 NOx annual emissions (BREAM) mg/kwh - - - - Flue gas quantity min-max kg/h 27-150 37-197 39-287 65-345 Flue gas temperature min-max C 30-63 30-64 30-62 30-64 Maximum counter pressure Pa 130 130 130 130 7638135 - v.02-13082015 7

3 Technical specifications Tab.3 Central heating circuit data Gas 210 ECO PRO 210-80 210-120 210-160 210-200 Water content l 12 16 20 24 Water operating pressure min bar 0.8 0.8 0.8 0.8 Water operating pressure (PMS) max bar 6.0 6.0 6.0 6.0 Water temperature max C 110 110 110 110 Operating temperature max C 90 90 90 90 Pressure drop secondary circuit (ΔT=20K) mbar 165 135 170 180 Minimum flow l/h 1120 1486 2142 2585 Tab.4 Electrical data Gas 210 ECO PRO 210-80 210-120 210-160 210-200 Supply voltage VAC 230 230 230 230 Power consumption full load max W 125 193 206 317 Power consumption part load min W 36 37 53 54 Power consumption standby min W 4 4 4 4 Electrical protection index IP 20 20 20 20 Fuse main fuse (A) 6.3 AT 6.3 AT 6.3 AT 6.3 AT Fuse PCB (A) 1.6 AT 1.6 AT 1.6 AT 1.6 AT Tab.5 Other data Gas 210 ECO PRO 210-80 210-120 210-160 210-200 Total weight (empty) kg 115 135 165 188 Average acoustic level (1) at a distance of 1 metre from the boiler (1) Maximum Central heating operation db(a) 59 59 59 59 Tab.6 Technical parameters Gas 210 ECO PRO 210-80 210-120 210-160 210-200 Condensing boiler Yes Yes Yes Yes Low-temperature boiler (1) Yes Yes Yes Yes B1 boiler No No No No Cogeneration space heater No No No No Combination heater No No No No Rated heat output Prated kw 87 115 166 200 Useful heat output at nominal heat output P 4 kw 87 115 166 200 (2) and high temperature operation Useful heat output at 30% of rated heat P 1 kw 29.1 38.3 55.2 66.6 output and low temperature regime (3) Seasonal space heating energy efficiency ƞ s % - - - - Useful efficiency at rated heat output ƞ 4 % 87.7 87.8 87.8 87.8 and high temperature regime (4) Useful efficiency at 30% of rated heat ƞ 1 % 97.7 97.5 97.3 97.6 output and low temperature regime (3) Auxiliary electricity consumption Full load elmax kw 0.1 0.2 0.2 0.3 Part load elmin kw 0.0 0.0 0.1 0.1 8 7638135 - v.02-13082015

3 Technical specifications Gas 210 ECO PRO 210-80 210-120 210-160 210-200 Standby mode P SB kw 0.004 0.004 0.004 0.004 Other items Standby heat loss P stby kw - - - - Ignition burner power consumption P ign kw - - - - Annual energy consumption Q HE kwh GJ - - - - Sound power level, indoors L WA db 67 67 67 67 Emissions of nitrogen oxides NO X mg/kwh 56 49 44 52 (1) Low temperature means 30 C for condensing boilers, 37 C for low temperature boilers and 50 C (at heater inlet) for other heating appliances. (2) High temperature operation means 60 C return temperature at heater inlet and 80 C feed temperature at heater outlet. See Refer to the back cover for contact details. 7638135 - v.02-13082015 9

3 Technical specifications 3.3 Electrical diagram Fig.1 X21 X01 SU-01 3 1 E 2 Electrical diagram X02 1 2 3 GY BK A B C 1 2 3 X01 X03 1 2 3 4 BR BR Nc C No Status X04 IF-01 X04 Pump 1 2 PE-6 PE-4 PE-5 X235 11 9 8 10 2 1 3 6 7 5 1 GY BK GN/YW 2 GN/YW PE-11 PE-12 GN/YW BR GN/YW 1 2 1 2 N + - 0-10V 3 GN/YW BR GN/YW X50 + - 0-10V X05 X51 X05 1 2 3 GN/YW L BK PE-2 PE-1 Mains GN/YW BR OTm 6.3AT OT On / Off 1 2 3 4 5 N L P 230V,50Hz T 6 BK X06 3 4 IF-01 X01 RL 5 6 GN/YW X235 14 13 12 BR GN/YW X55 1 2 3 9 PCU-01 PE-7 X05 X04 X07 X08 1 10 7 8 A B C D 1...6 X02 X09 1 2 3 4 BR WH GN YW X91 1 5 4 2 PE-2 BK GN/YW 9 1...6 X02a X10 1...6 D 1 2 3 Nc C No Status X03 SCU-X01 PCU-01 1 2 3 Nc C No Status X04 X01 X11 1 2 3 5 4 6 7 10 8 9 RD WH OR OR P / BK/ WH WH BR/ WH X03 YW/ WH X02 X03 X11 X10 X09 X08 X07 X06 SCU-X01 X04 X02a X02 X05 BK 10 11 12 13 14 X04 A C B D N L N L N L Wps Tout Gps VPs X03 SCU-S01 X01 1 3 2 X01 1 Ignition transformer (IT) 2 Ionisation/ignition electrode (E) 3 Safety valve (SV1) 1...6 X02 1 2 Fgv 3 4 5 6 7 8 9 X03 For the 210-80 - 210-120, the gas valve unit connection is 230 VAC. For the 210-160 - 210-200, the gas valve unit connection is 230 RAC. 4 Safety valve (SV2) For the 210-80 - 210-120 boilers, the gas valve unit connection is 230 VAC. For the 210-160 - 210-200 boilers, the gas valve unit connection is 230 RAC. 5 Power supply (P) 6 On/off switch (S) Hdv Egv SCU-S01 1 2 3 Nc C No Status X04 1 2 3 4 5 6 7 8 9 O S + X05 7 Computer connection (PC) 8 Control panel (HMI) 9 Fan (FAN) 10 Flow sensor (FTS) 11 Pressure switch (PS) 12 Storage parameter (PSU) 13 Return sensor (RTS) 14 Heat exchanger sensor (HTS) BK BK/ WH / WH BR BR/ WH Black Black/White Blue Blue/White Brown Brown/White X04 X05 X02 AD-3000122-01 10 7638135 - v.02-13082015

3 Technical specifications GN GN/ YW GY OR Green Green/Yellow Grey Orange RD WH YW YW/ WH Red White Yellow Yellow/White 7638135 - v.02-13082015 11

4 Commissioning 4 Commissioning 4.1 Gas settings 4.1.1 Adaptation to a different gas type Warning Only a qualified installer may carry out the following operations. Tab.7 Factory setting G20 (H gas) Parameter Description 210-80 210-120 210-160 210-200 Maximum speed for central heating 51 64 48 57 Minimum speed for central heating 12 13 10 12 Start speed 17 17 17 17 Restrictor ø (mm) 8,4 8,4 Before operating with a different type of gas, carry out the following steps. Fig.2 Replacing restrictor X.XX 1. Check the correct diameter of the existing restrictor (see table) and replace it if necessary. 2. Set the fan speed as indicated in the table for the relevant gas type. The speed can be changed with a parameter setting. AD-3000112-01 Tab.8 Adjustment for gas type G31 (propane) Parameter Description 210-80 210-120 210-160 210-200 Maximum speed for central heating 52 61 60 55 Minimum speed for central heating 15 14 15 13 Start speed 20 20 22 22 Restrictor ø (mm) 6,5 6,5 10 10 3. Check the setting of the gas/air ratio. 4.1.2 Checking/setting the combustion 1. Unscrew the cap from the flue gas measuring point. 2. Insert the probe for the flue gas analyser into the measurement opening. Warning During measurement, seal the opening around the sensor fully. The flue gas analyser must have a minimum accuracy of ±0.25% O 2 /CO 2. The flue gas analyser must meet the requirements of BS 7927 or BS-EN 503793 and be calibrated according to the manufacturer's requirements. 3. Measure the percentage of O 2 /CO 2 in the flue gases. Take measurements at full load and at part load. Checking/setting values O 2 /CO 2 at full load 1. Set the boiler to full load. 2. Measure the percentage of O 2 /CO 2 in the flue gases. 3. Compare the measured value with the checking values in the table. 12 7638135 - v.02-13082015

4 Commissioning Tab.9 Checking/setting values for O 2 at full load for G20 Values at full load for G20 O 2 % (1) CO 2 % (1) 210-80 3,9-5,2 (1) - 6,5 8,1-8,8 (1) - 9,5 210-120 3,9-5,2 (1) - 6,5 8,1-8,8 (1) - 9,5 210-160 4,3-5,2 (1) 8,8 (1) - 9,3 210-200 4,3-5,2 (1) 8,8 (1) - 9,3 (1) Nominal value Tab.10 Checking/setting values for O 2 at full load for G31 Values at full load for G31 O 2 % (1) CO 2 % (2) 210-80 4,7-5,7 (2) - 6,7 9,3-10,0 (2) - 10,7 210-120 4,7-5,7 (2) - 6,7 9,3-10,0 (2) - 10,7 210-160 4,9-5,7 (2) 10,0 (2) - 10,5 210-200 4,9-5,7 (2) 10,0 (2) - 10,5 (1) Nominal value 4. If the measured value is outside of the values given in the table, correct the gas/air ratio. The 210-80 and 210-120 boilers are equipped with a restrictor on the gas valve unit. They can therefore only be set to part load. Fig.3 210-160 - 210-200 5. Using the adjusting screw, set the percentage of O 2 /CO 2 for the gas type being used to the nominal value. This should always be inside the highest and lowest setting limit. The direction in which the adjustment screw must be turned to increase or decrease the gas flow is indicated on the gas valve unit. 6. Check the flame through the inspection window. The flame must not blow off. AD-3000113-01 Checking/setting values for O 2 /CO 2 at part load 1. Set the boiler to part load. 2. Measure the percentage of O 2 /CO 2 in the flue gases. 3. Compare the measured value with the checking values in the table. Tab.11 Checking/setting values for O 2 at part load for G20 Values at part load for G20 O 2 % (1) CO 2 % (1) 210-80 3,4-4,3 (1) 9,3 (1) - 9,8 210-120 3,4-4,3 (1) 9,3 (1) - 9,8 210-160 3,4-4,3 (1) 9,3 (1) - 9,8 210-200 3,4-4,3 (1) 9,3 (1) - 9,8 (1) nominal value 7638135 - v.02-13082015 13

4 Commissioning Fig.4 Adjusting screw Tab.12 Checking/setting values for O 2 at part load for G31 Values at part load for G31 O 2 % (1) CO 2 % (2) 210-80 4,1-4,9 (2) 10,5 (2) - 11,0 210-120 4,1-4,9 (2) 10,5 (2) - 11,0 210-160 4,1-4,9 (2) 10,5 (2) - 11,0 210-200 4,1-4,9 (2) 10,5 (2) - 11,0 (1) nominal value 4. If the measured value is outside of the values given in the table, correct the gas/air ratio. 5. Using the adjusting screw, set the percentage of O 2 /CO 2 for the gas type being used to the nominal value. This should always be inside the highest and lowest setting limit. The direction in which the adjustment screw must be turned to increase or decrease the gas flow is indicated on the gas valve unit. 6. Check the flame through the inspection window. The flame must not blow off. 7. Repeat the full load test and the part load test as often as necessary until the correct values are obtained. 8. Set the boiler back to the normal operating status. AD-3000111-01 14 7638135 - v.02-13082015

5 Settings 5 Settings 5.1 Parameter descriptions Tab.13 Factory setting Parameter Description Adjustment range 210-80 210-120 210-160 210-200 Minimum pump speed 0% 100% 20 20 20 20 Maximum pump speed 0% 100% 100 100 100 100 5.2 Displaying the measured values The control unit continually registers various values from the boiler and the connected sensors. These values can be read on the control panel of the boiler. 5.2.1 Status and sub-status gives the following status and sub-status num The information menu bers: Tab.14 Status Status and sub-status numbers Stand-by mode Boiler start (heat demand) Burner start Burning on CH operation Sub-status Stand-by mode Anti-swing Open hydraulic valve Start pump Wait for the correct temperature before burner start Open external gas valve Fan on Open flue damper Pre-ventilation Wait for release signal Burner on Gas leakage control VPS Pre-ignition Main ignition Flame detection Intermediate ventilation Burner on (flue gas discharge test) Temperature control Limited temperature control (ΔT protection) Capacity control Temperature gradient protection level 1 (modulate down) Temperature gradient protection level 2 (part load) Temperature gradient protection level 3 (blocking) Modulate up for flame control Temperature stabilisation time Cold start 7638135 - v.02-13082015 15

5 Settings Status Burner stop Boiler stop (end of heat demand) Control stop Blocking Sub-status Burner off Post ventilation Fan off Close flue damper Stop fan Close the external gas valve Pump post circulation Pump off Close hydraulic valve Start anti-swing Wait for burner start Anti-swing Blocking code 16 7638135 - v.02-13082015

6 Disposal/recycling 6 Disposal/recycling 6.1 Removal/recycling Removal and disposal of the boiler must be carried out by a qualified person in accordance with local and national regulations. To remove the boiler, proceed as follows: 1. Switch off the boiler's electrical connection. 2. Shut off the gas supply. 3. Shut off the water supply. 4. Drain the installation. 5. Remove the siphon. 6. Remove the air supply/flue gas outlet pipes. 7. Disconnect all pipes on the boiler. 8. Remove the boiler. 7638135 - v.02-13082015 17

7 Appendix 7 Appendix 7.1 ErP information 7.1.1 Product card Tab.15 Product card Remeha - Gas 210 ECO PRO 210-80 210-120 210-160 210-200 Seasonal space heating energy efficiency class - - - - Rated heat output (Prated or Psup) kw 87 115 166 200 Seasonal space heating energy efficiency % - - - - Annual energy consumption GJ - - - - Sound power level L WA indoors db 67 67 67 67 See For specific precautions in relation to assembly, installation and maintenance: Safety, page 4 7.2 Optional electrical connections 7.2.1 Connection options for the PCB (SCU-X03) Fig.5 SCU-X03 PCB X4 X3 SCU-X03 X1 SW1 SW2 X2 The SCU-X03 PCB can control a modulating central heating pump. Depending on the make and type of pump, the pump can be controlled by a 0 10 V, 4 20 ma or a PWM signal. The speed of the pump is modulated based on the signal received from the boiler. For correct connection of the pump, see the documentation supplied with the pump. Ctrl 0 + 0 + AD-0000061-01 Connecting on/off contact 1. Connect the on/off contact of the CH pump to the connector X1. Caution Do not use the on/off contact to interrupt the power supply to the pump. Connecting a central heating pump 1. Connect the CH pump controller to the connector X2. Select the type of signal that will be received from the boiler using the rotary knob SW1 on the PCB. See table below No. Description 0 Pump modulation signal 1 Required heat output of boiler 2 Current heat output of boiler 3 4 18 7638135 - v.02-13082015

7 Appendix No. Description 5 6 7 8 9 Caution If possible, use the pump modulation signal. This provides the most accurate pump control. In positions 3 to 9 the control PCB receives no signal from the boiler and the boiler responds as in position 0. If the automatic burner unit does not support pump modulation, the pump will behave as an on/off pump. Select the type of signal that controls the pump using the rotary knob SW2 on the PCB. See table below. No. Description 0 0 10 V (Wilo pump) 1 0 10 V (Grundfoss pump) 2 PWM 3 4 20 ma 4 5 6 7 8 9 Caution In positions 4 to 9 the control PCB sends no signal to the pump and the pump will not start up. 7638135 - v.02-13082015 19

7 Appendix 20 7638135 - v.02-13082015

7 Appendix 7638135 - v.02-13082015 21

7 Appendix 22 7638135 - v.02-13082015

Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing. Subject to alterations.

Remeha Commercial UK Innovations House 3 Oaklands Business Centre Oaklands Park RG41 2FD Wokingham Tel: +44 (0)118 978 3434 Fax: +44 (0)118 978 6977 Internet: www.remeha.co.uk E-mail: boilers@remeha.co.uk 7638135 - v.02-13082015 7638135-001-02