Installation and Servicing Instructions

Size: px
Start display at page:

Download "Installation and Servicing Instructions"

Transcription

1 Installation and Servicing Instructions Alpha Pro Tec 50, 70, 90 and 5 Wall Mounted, Fan Assisted, Gas Fired, High Efficiency Condensing System Boilers For Technical help or for Service call... ALPHA HELPLINE Tel: Nepicar House, London Road, Wrotham Heath, Sevenoaks, Kent TN5 7RS 005 For use with Natural Gas or Propane Gas (LPG) Leave these instructions with the User

2 BENCHMARK SCHEME To comply with Building Regulations Part L (Part 6 in Scotland) the boiler should be installed in accordance with the manufacturer s instructions. Self-certification that the boiler has been installed to comply with Building Regulations can be demonstrated by completing and signing the Benchmark Checklist at the back of these instructions Code of Practice For the installation, commissioning and servicing of domestic heating and hot water products. Benchmark places responsibilities on both manufacturers and installers*. The purpose is to ensure that customers** are provided with the correct equipment for their needs, that it is installed, commissioned and serviced in accordance with the manufacturer's instructions by competent persons and that it meets the requirements of the appropriate Building Regulations. Installers are required to carry out work in accordance with the following: Standards of Work Be competent and qualified to undertake the work required. Install, commission, service and use products in accordance with the manufacturer's instructions provided. Ensure that where there is responsibility for design work, the installation is correctly sized and fit for purpose. Meet the requirements of the appropriate Building Regulations. Where this involves notifiable work be a member of a Competent Persons Scheme or confirm that the customer has notified Local Authority Control (LABC), prior to work commencing. Complete all relevant sections of the Benchmark Checklist/Service Record when carrying out commissioning or servicing of a product or system. Ensure that the product or system is left in a safe condition and, where possible, in good working order. Highlight to the customer any remedial or improvement work identified during the course of commissioning or servicing work. Refer to the manufacturer's helpline where assistance is needed. Report product faults and concerns to the manufacturer in a timely manner. Customer Service Show the customer any identity card that is relevant to the work being carried out prior to commencement or on request. Give a full and clear explanation/demonstration of the product or system and its operation to the customer. Hand over the manufacturer's instructions, including the Benchmark Checklist, to the customer on completion of an installation. Obtain the customer's signature on the Benchmark Checklist to confirm satisfactory demonstration and receipt of manufacturer's instructions. Advise the customer that regular product servicing is needed, in line with manufacturers' recommendations, to ensure that safety and efficiency is maintained. Respond promptly to calls from a customer following completion of their work, providing advice and assistance by phone and, if necessary, visiting the customer. Rectify any installation problems at no cost to the customer during the installer's guarantee period. * The use of the word "installer" is not limited to installation itself and covers those carrying out installation, commissioning and/or servicing of heating and hot water products, or the use of supporting products (such as water treatment or test equipment). ** Customer includes householders, landlords and tenants. Benchmark Commissioning and Servicing Section It is a requirement that the boiler is installed and commissioned to the manufacturers instructions and the data fields on the commissioning checklist completed in full. To instigate the boiler guarantee the boiler needs to be registered with the manufacturer within one month of the installation. To maintain the boiler guarantee it is essential that the boiler is serviced annually by a Gas Safe registered engineer who has been trained on the boiler installed. The service details should be recorded on the Benchmark Service Interval Record and left with the householder. Useful contact details: Gas Safe Register Alpha Heating Innovation: General Sales Enquiries Technical Helpline Alpha Pro Tec - Benchmark Scheme

3 CONTENTS Introduction General data General boiler information... 4 Installation Commissioning and using the boiler Routine servicing Wiring diagram Fault finding Programming the boiler PCB Performance data...38 Cascade system installation Short parts list...43 Benchmark Checklist...46 Service record...47 INTRODUCTION The Alpha Pro Tec range are wall mounted high efficiency condensing, fan assisted system boilers. The burner is lit electronically and the heat output is controlled by a modulating fan and gas valve. These are system boilers providing heating only for sealed central heating systems. However, they may be used with an open central heating system if required - refer to Section 3.8. The boilers are supplied with type B23 flue configuration (open chamber and forced draught) but can be changed to type C (room sealed) by using a kit. The boilers are fitted with a pump, 4 bar safety valve and pressure gauge fully assembled and tested. They are designed for use with a fully pumped, sealed and pressurised central heating system. If used with an open system refer to Section 3.8. The boilers can be supplied for use with Natural gas or Propane Gas (LPG). Note: There are a number of additional controls and accessories available for use with the boilers to enable cascade and zone installations to be used - See Section. Further information is available from Alpha Therm Ltd. IMPORTANT It is the law that all gas appliances are installed by a competent person, ie Gas Safe registered personnel, in accordance with the following recommendations:- Current Gas Safety (Installation and Use) Regulations All current Building Regulations issued by the Department of the Environment, i.e. Approved Document L26. Building Standards (Scotland) (Consolidation) Regulations issued by the Scottish Development Department UK Water Regulations/Byelaws (Scotland) Health & Safety Document No. 635 (The Electricity At Work Regulations 989) The installation should also be in accordance with the following British Standard Codes of Practice:- BS 5440-: Flueing and Ventilation Requirements BS : Installation and Maintenance of Flues and Ventilation BS 5546: Specification for Water Heating Appliances BS 6644: 20...Specification for Installation gas fired boilers 70 kw.8 MW BS 6798: Specification for Installation gas fired boilers up to 70 kw BS 689: A2: Installation of low pressure Gas Pipework IGEM/UP/2...Installation of pipework IGEM/UP/4...Commissioning of gas fired plant IGE/UP/0...Installation of Flued gas appliances IGEM/UP/6...Design for natural gas installations IGE/UP/ and A...Strength Testing and tightness testing Natural Gas Installations Reference should also be made to any other standards and requirements relating to the installation depending on the location and use. Reference should be made to DEFRA document 'Guide to condensing boiler installation assessment procedures for dwellings'. If installation is in a timber framed building, refer to the Institute of Gas Engineers document IGE/UP/7. This appliance meets the requirements of IPX5D, ie degree of protection against moisture. This appliance contains no asbestos and no substances have been used in the construction process that contravene the COSHH Regulations (Control of Substances Hazardous to Health). Failure to install this appliance correctly could lead to prosecution. It is in your own interest and that of safety to ensure that the law is complied with. Manufacturer's instructions must NOT be taken in anyway as over-riding statutory obligations. Notes:. Ensure that the Benchmark Checklist has been completed after the boiler has been installed and commissioned. 2. It is the law that all domestic boiler installations are registered by the installer through the Gas Safe Notification Scheme. Propane Gas (LPG) - In addition to the regulations and requirements stated, the boiler must be installed in accordance with BS 5482: - The Installation of Propane Burning Appliances in Permanent Dwellings. Alpha Pro Tec - Contents/Introduction 3

4 2 GENERAL DATA 2. TECHNICAL DATA Heat output condensing (50/30 C) kw Heat output non condensing (80/60 C) kw Heat output minimum kw NOx Class Maximum CO/CO 2 Ratio Maximum CO ppm SAP/SEDBUK seasonality efficiency 2005 % SAP/SEDBUK seasonality efficiency 2009 % Effieciency at maximum output 60ºC/80ºC % Effieciency at maximum output 30ºC/50ºC % Effieciency at part load 30ºC/50ºC % Effieciency at part load 30ºC/40ºC % Maximum system temperature C Adjustable system temperature C Maximum primary system pressure bar Minimum primary system pressure bar Recommended system pressure - Cold bar System safety valve setting bar Electrical power supply V ~ 50 Hz Electrical power consumption - Maximum Watts Electrical power consumption - Standby Watts Pro Tec 50 Pro Tec 70 Pro Tec Pro Tec PHYSICAL DATA Pro Tec 50 Pro Tec 70 Pro Tec 90 Pro Tec 5 Boiler flow and return connections BSP ½" ½" ½" ½" Pressure relief valve connection BSP ¾" ¾" ¾" ¾" Gas connection BSP 28 mm 28 mm 28 mm 28 mm Boiler dimensions Height mm Width mm Depth mm Clearances for servicing Bottom mm Top (horizontal flue) mm Top (vertical flue) mm Sides mm Front mm Boiler dry lift weight kg Boiler operating weight (full of water) approx. kg Water content litre Alpha Pro Tec - Data

5 2.3 COMBUSTION DATA Natural Gas G20 (Cat I2H 2H) Pro Tec 50 Pro Tec 70 Pro Tec 90 Pro Tec 5 Heat input (gross) kw Heat input (net) kw Gas burner injector diameter mm Gas supply pressure mbar Gas rate at maximum output m 3 /h Flue mass flow rate at maximum output kg/h Flue mass flow rate at minimum output kg/h Flue temperature (nominal) C CO 2 at maximum output (factory set) % CO 2 at minimum output (factory set) % CO (nominal) at 0% O 2 ppm CO weight (nominal) mg/kwh Dry NOX weighted mg/kwh Propane G3 (Cat I3P 3P) Pro Tec 50 Pro Tec 70 Pro Tec 90 Pro Tec 5 Heat input (gross) kw Heat input (net) kw Gas burner injector diameter mm Gas supply pressure mbar Gas rate at maximum output l/h Flue mass flow rate at maximum output kg/h Flue mass flow rate at minimum output kg/h Flue temperature (nominal) C CO 2 at maximum output (factory set) % CO 2 at minimum output (factory set) % CO (nominal) at 0% O 2 ppm CO weight (nominal) mg/kwh Dry NOX weighted mg/kwh Alpha Pro Tec - Data 5

6 2.4 FLUE DATA * Max. flue length 80/25 concentric (room sealed) m * Max. flue length 80 single pipe (B23 open flue) m Flue system (optional) Concentric flue mm Hole in wall required mm Flue system (as supplied) Open flue mm Hole in wall required mm Pro Tec 50 Pro Tec 70 Pro Tec / / / Pro Tec / * Maximum Flue Lengths (includes first bend onto boiler flue connection for horizontal installations) Open flue - Maximum horizontal or vertical flue with single 80 mm dia. according to Table above 90 bend is equivalent to 2. m of flue length 45 bend is equivalent to.3 m of flue length Vertical terminal is equivalent to 2 m of flue length Concentric flue - Maximum horizontal flue or vertical flue according to Table above 90 bend is equivalent to.9 m of flue length 45 bend is equivalent to.4 m of flue length Vertical terminal is equivalent to 2 m of flue length Notes:. Ensure all flues slope downwards towards the boiler by a minimum of 25 to 30 mm per metre of flue. 2. It is recommended that horizontal and vertical flue assemblies should be supported approximately every.5 m with access provided to the joints. 3. These dimensions only apply for flue parts supplied by Alpha. Cascade flue options are also available, please contact Alpha for further details. 2.5 AVAILABLE PUMP HEAD The Pro Tec boilers are fitted with a 3 speed pump. The boiler does not operate correctly with the pump set at the slowest speed. To ensure optimal boiler operation, especially in the case of new systems it is recommended that the pump is set to maximum speed. The following graphs indicate the pump head and flow rates available at the maximum speed setting (A) and the middle speed setting (B). Pump release: If, after a prolonged period of inactivity, the pump is sticking, unscrew the front cap and turn the motor shaft using a flat bladed screwdriver. Take great care during this operation to avoid damage to the motor. For larger systems an additional external pump can be fitted and controlled by the boiler using a relay switch. See Fig Pro Tec Head (m water) B A Flow rate (l/h) Fig Alpha Pro Tec - Data

7 Pro Tec 70 Head (m water) A B Flow rate (l/h) Fig. 2.2 Pro Tec 90 Head (m water) B A Flow rate (l/h) Fig. 2.3 Alpha Pro Tec - Data 7

8 Pro Tec Head (m water) B A Flow rate (l/h) Fig ELECTRICAL CONNECTIONS Note: This Appliance Must Be Earthed 3-way valve (optional) 220/240 External relay (optional) Coil 220 V ~ 50 Hz Max. 0. A DHW sensor (optional) External sensor (optional) Remote switching (optional) i.e. room thermostat remove link F to E A AB B Mains Supply 220 V ~ 50 Hz Fuse 3.5 AF L L N N L DO NOT connect 220/240 V N L IT IS IK Q P C D R H G J F E N L R R2 A A2 S S OTOT2 Y Z M O N L External reset 220/240 V Alarm free contact Max. A 220/240 V Open Therm _ + _ + Analog input 0-0 V 37 A 38 B Zone manager (optional) Fig Alpha Pro Tec - Data

9 2.7 BOILER SCHEMATIC Pro Tec (P3) Flow Gas Condensate discharge Return Tundish 2 Safety valve (4 bar) 3 Drain point 4 Flow manifold 5 Condensate trap 6 Gas valve 7 Injector 8 Fan 9 Manifold cover 0 Ignition electrode Combustion chamber cover 2 Heat exchanger 3 Heat exchanger automatic air vent 4 Flue sensor 5 Thermofuse 6 Air sampling point 7 Flue sampling point 8 Flue hood 9 Venturi positive point (P2) 20 Overheat thermostat (manual reset) 2 Overheat thermostat 22 Primary flow temperature sensor 23 Primary return temperature sensor 24 Flame sensing electrode 25 Primary flow sensor 26 Air inlet pipe 27 Burner 28 Venturi 29 Automatic air vent 30 Pump Fig. 2.6 Alpha Pro Tec - Data 9

10 Pro Tec 70, 90, (P3) Flow Gas Condensate discharge Return Tundish 2 Safety valve (4 bar) 3 Drain point 4 Primary pressure switch 5 Flow manifold 6 Gas valve 7 Fan 8 Injector 9 Air inlet pipe 0 Flame sensing electrode Combustion chamber cover 2 Heat exchanger 3 Flue hood 4 Air sampling point 5 Flue sampling point 6 Heat exchanger automatic air vent 7 Primary flow temperature sensor 8 Overheat thermostat 9 Primary return temperature sensor 20 Overheat thermostat (manual reset) 2 Flue sensor 22 Burner 23 Thermofuse 24 Ignition electrode 25 Manifold cover 26 Venturi 27 Pump 28 Condensate trap Fig Alpha Pro Tec - Data

11 3 GENERAL BOILER INFORMATION 3. GAS SUPPLY Natural Gas: The meter and supply pipes must be capable of delivering the required quantity of gas in addition to the demand from any other appliances. The boiler requires at least a 28 mm gas supply pipe and ensure the inlet supply pressure is at least 20 mbar (Natural Gas) The complete installation, including the meter, must be tested for gas tightness and purged as described in BS 689 and IGE/UP/, IGE/UP/A or IGE/UPB. Propane Gas (LPG): The local Propane Gas supplier should be consulted, at the installation planning stage, in order to establish the availability of an adequate supply of gas, 37 mbar for Propane Gas (LPG). 3.2 ELECTRICAL SUPPLY The boiler requires a 220/240 V ~ 50 Hz permanent mains supply, fused at 3 A Note: The boiler must be earthed. There must only be one common isolator, providing complete electrical isolation, for the boiler and any external controls. This boiler has been fitted with a supply cable, however, if it is necessary to fit a cable use PVC insulated cable not less than 0.75 mm² (24 x 0.2 mm). The boiler should be connected to a fused three pin plug and unswitched shuttered socket outlet, or a fused double pole switch with a contact separation of at least 3 mm in both poles. Wiring external to the boiler must be in accordance with the current IEE Wiring Regulations (BS 767). 3.3 AIR SUPPLY Open flued (Type B23 flue) Alpha Pro Tec boilers leave the factory with 'B23' type configuration (open chamber and forced draught - single flue pipe) and receive the air for combustion from openings in the rear of the boiler, therefore air supply for combustion and ventilation must be provided in accordance with BS 5440:2 (for domestic installations with a net input less than 70 kw) or BS 6644 (for commercial installations with a net input over 70 Kw). Room sealed (Type C flue) If the boilers are converted to a 'C' type configuration (sealed chamber and forced draught - concentric flue pipe) as described in Section 3.4 only air for ventilation is required.. If the boiler is installed in a room - No air vents are required in the room in which the boiler is installed. 2. If the boiler is installed in a cupboard or compartment - Permanent air vents for ventilation are required in the cupboard or compartment, one at high level and one at low level, either direct to the outside air or to a room. Both the high and low level air vents must communicate with the same room or must be on the same wall to outside air. Both the high and low level vent must each have a free area as per BS 5440:2 or BS The minimum clearances for servicing must always be maintained. 3.4 FLUE SYSTEM The flue system must be installed in accordance with BS 5440: or BS For horizontal flues ensure the flue assembly slopes downwards towards the boiler by a minimum of mm per metre of flue. It is recommended that horizontal and vertical flue assemblies should be supported at least every.5 m with access provided to the joints. Alpha Pro Tec boilers leave the factory with 'B23' type flue configuration (open chamber and forced draught - single flue pipe). To change the configuration to 'C' type (sealed chamber and forced draught - concentric flue pipe), remove the 80 mm dia. adapter, the bracket and gasket from the top of the boiler and fit the concentric flue adaptor, see Sections 4.5 and 4.6. Note:. Under no circumstances must the flue length (including allowances for extra bends) exceed the maximum flue lengths stated for each type of flue. 2. Failure to use the correct Alpha flue components with the boiler will invalidate the boilers CE approval, guarantee and may be unsafe. Seals for flue elements - If lubrication of components (already performed by the manufacturer) is not sufficient, remove the residual lubricant using a dry cloth, then to ease fitting apply a small amount of common or industrial talc to the seal. Ensure that the seals are correctly located in the elbows and extensions when assembling the flue. Note: Do not use silicone or other oil based lubricants on the flue seals. Alpha Pro Tec - General Boiler Information

12 Flue components are available as follows:- Open flue - 80 mm dia. single pipe Horizontal terminal kit 80 mm dia. (includes metre straight terminal section, one 90 bend and two collars) Vertical terminal kit 80 mm dia Extension pipe metre x 80 mm dia bend 80 mm dia bend 80 mm dia mm flue support bracket Pitched roof flashing (universal) Flat roof flashing (universal) Concentric flue - 80/25 mm dia Horizontal terminal kit 80/25 mm dia. (includes metre straight terminal section, one 90 bend, two collars and adaptor with square gasket) Vertical terminal kit 80/25 mm dia. (includes adaptor with square gasket) Extension kit metre x 80/25 mm dia bend 80/25 mm dia bend 80/25 mm dia Pitched roof flashing (universal) Flat roof flashing (universal) Cascade flue options are also available for multiple boilers Horizontal Concentric Flue Options L Max. L Max. Open flue: 80 mm dia. single pipe 90 bend is equivalent to 2. m of flue length 45 bend is equivalent to.3 m of flue length Concentric flue: 80/25 mm dia. 90 bend is equivalent to.9 m of flue length 45 bend is equivalent to.4 m of flue length Pro Tec model 80/25 mm Concentric flue 80 mm Open flue m 30 m L Max m 8 m 28 m 4 m 5 5 m 8.5 m Fig Alpha Pro Tec - General Boiler Information

13 3.4.2 Vertical Concentric Flue Options Not less than 000 mm Not less than 000 mm L Max. L Max. L Max. Pro Tec model 80/25 mm Concentric flue 80 mm Open flue m 30 m 70 m 28 m 90 8 m 4 m 5 5 m 8.5 m Fig FLUE TERMINATION The Alpha ProTec range of boilers can be individually flued using either 80 mm open flue configuration or 80/25 mm concentric flue. Multiple boilers can be individually flued or cascade flue kits are also available. When installing these boilers careful planning and consideration for the flue system must be undertaken. All flue systems must conform to the relevant standards depending on the boiler size and configuration. Refer to BS 6644, BS 5440 or IGE/UP/0 for the correct flue location requirements. 3.6 BOILER LOCATION The boiler is not suitable for external installation unless it is installed within a purpose designed weatherproof building. The boiler must be installed on a flat vertical wall which is capable of supporting the weight of the boiler. The boiler can be fitted to or adjacent to a wall comprising of a combustible material without the need for a special thermal insulation barrier. If the boiler is to be fitted in a timber framed building, it should be fitted in accordance with the Institute of Gas Engineers 'Guide for Gas Installations in Timber Frame Housing', reference IGE/UP/7. The boiler may be installed in any room or internal space, although particular attention is drawn to the requirements of the current IEE Wiring (BS 767) Regulations, and in Scotland, the electrical provisions of the Building Regulations applicable in Scotland, with respect to the installation of the boiler in a room or internal space containing a bath or shower. Where a roomsealed boiler is installed in a room containing a bath or shower, it must not be possible for a person using the bath or shower to touch any electrical switch or boiler control utilising mains electricity. The boiler may be installed in a cupboard or compartment, provided it is correctly designed for that purpose, i.e. complies with the Building Regulations and the requirements of BS 6798 and BS Propane Gas (LPG): Installation pipes, cylinders and pressure regulators should be fitted in accordance with BS 5482:. Bulk tank installation must comply with the requirements of the Home Office code of practice for the storage of liquefied petroleum gas at fixed installations. The boiler must not be installed in a room or internal space below ground level, e.g. in a basement or cellar, except where at least one side is open to ground level. 3.7 FROST PROTECTION The boiler is fitted with a frost thermostat that activates the pump and burner when the system water temperature in the boiler falls below 3 C. The electrical supply to the boiler must be left on for the thermostat to operate and the selector switch must be set to ON. Alpha Pro Tec - General Boiler Information 3

14 3.8 CENTRAL HEATING SYSTEM - Fig. 3.3 The boiler is designed for use in a sealed central heating system in accordance with the requirements of BS 5449 and BS The system should be designed to operate with flow temperatures of up to 85 C. When designing the system, the pump head, expansion vessel size, mean radiator temperature, etc. must all be taken into account. Refer to the pump performance graph Section 2.5 for guidelines. However, if the boiler is to be used with an open central heating system refer to Fig. 3.3 and use a barrier heat exchanger (i.e. separates the boiler primary circuit from the open heating circuit). This will also ensure the boiler heat exchanger is protected from an old/dirty system. Sealed system volume - An expansion vessel is not incorporated into the boiler. An expansion vessel must be fitted in the position shown in Fig To check correct operation of the expansion vessel the system pressure should not be more than 3.5 bar when the system is at maximum operating temperature (for further guidance refer to BS 7074:), For example an 8 litre expansion vessel is suitable for a sealed system of 80 litres. Expansion vessels should be set to bar before the system is filled. The boiler is supplied with the following components built in:- Pressure relief valve - complying with BS 6759 and set to operate at 4 bar. The discharge pipe must be routed clear of the boiler and terminated in such a manner that it can be seen, but cannot cause injury to persons or property. Pressure gauge - To indicate the system pressure to be maintained. By-pass - The boiler has no built-in by-pass, therefore a by-pass is required for the system. Installation on a low temperature heating system. The boiler can directly feed a low temperature system, varying the maximum delivery temperature of the boiler and setting a value of between 20 and 85 C. To vary the boiler maximum delivery temperature, modify the boiler maximum delivery temperature of parameter No. 02 as described in Section 9. In this mode it is advisable to include a safety limit thermostat set at 55 C in series with the boiler controls. The thermostat Make up vessel (sealed system only) Static head of system Boiler Automatic air vent Expansion vessel (sealed system only) Double check valve assy. (sealed system only) Filling point (sealed system only) Heating flow Return Barrier heat exchanger used on open or old/dirty systems Note: A drain tap should be installed at the lowest point of the heating circuit and beneath the appliance. Heating return System drain tap Return Flow Flow Heating flow Heating return Fit pump if Barrier heat exchanger used Expansion vessel (sealed system only) Drain tap Fig. 3.3 must be positioned in the system flow pipe at more than 2 metres from the boiler. 3.9 FILLING THE SEALED CENTRAL HEATING SYSTEM - Figs. 3.4, 3.6 The system design pressure (cold) should be set to.0 bar. This pressure is equivalent to a static head (see Fig. 3.3) of 0.2 metres of water. Provision should be made to replace water lost from the system. This can be by manual or automatic means, as shown in Figs. 3.4 and 3.5. The position for connecting an automatic make-up vessel is indicated in Fig A double check valve assembly must be used, as shown in Fig Alpha Pro Tec - General Boiler Information

15 Filling of the system must be carried out in a manner approved by the local Water Undertaking. Where allowed, the system may be filled via a temporary connection as shown in Fig After filling, always disconnect the flexible hose of the filling loop. All fittings used in the system must be able to withstand pressures up to 4 bar. Drain taps (to BS 2879) must be used to allow the system to be completely drained. A pressurisation unit may also be used to maintain the system level. Refer to the instructions supplied with the unit for correct installation. Heating circuit return Stop valve Hose unions Double check valve assembly Test cock Filling loop temporarily connected Stop valve Mains water supply Heating circuit return Double check valve assembly Test cock Overflow Stop valve Mains water supply Feed cistern to be located above highest point in the system Fig. 3.4 Fig FLUSHING THE HEATING SYSTEM It is essential that the central heating system is thoroughly cleaned and flushed when fitting an Alpha Pro Tec boiler. Failure to do so will invalidate the warranty. If this is difficult because the system is old/dirty refer to Section 3.8, Fig. 3.3 gives consideration to using a barrier heat exchanger. The primary condensing heat exchanger is constructed in stainless steel and therefore is compatible with most materials used in a heating system. A cleaning agent and inhibitor should be used, they must be applied in accordance with their manufacturers instructions. Only products from Fernox and Sentinel are acceptable for use with the Alpha Pro Tec boilers. Further information can be obtained from Fernox (Tel: ) or Sentinel (Tel: ). The system should be flushed in accordance with BS 7593 and BS The following procedures are recommended:. Installing onto a new system:- a. Fill the system, vent at high points, at pump and radiators. b. Check for leaks. c. Rapidly drain the system. d. If required, chemically clean the system as instructed by the recommended cleaner manufacturer. Note: Ensure that the system is flushed to remove any remains of the cleaner. e. If chemical cleaner is not used to clean the system:- i) Refill the system. ii) Switch on the boiler and allow the system to heat up to the normal operating temperature. iii) Rapidly drain the system while the water is still hot. iv) Refill the system. f. As required, add the recommended inhibitor to the system as instructed by the inhibitor manufacturer. g. Recheck for leaks. 2. Installing onto an existing system, clean the system before fitting the new boiler:- a. If the old boiler is still working:- i) Switch on the boiler and allow the system to heat up to the normal operating temperature. ii) Rapidly drain the system while the water is still hot. iii) Refill and chemically clean the system as instructed by the recommended cleaner manufacturer. iv) Ensure the system is flushed to remove any remains of the cleaner. v) Fit the new boiler. b. If the old boiler is not working:- i) Rapidly drain the system. ii) Remove the old boiler. iii) Flush the system through. iv) Fit the new boiler. v) Refill and chemically clean the system as instructed by the recommended cleaner manufacturer. vi) Ensure the system is flushed to remove any remains of the cleaner. c. As required, add the recommended inhibitor to the system as instructed by the inhibitor manufacturer. d. Check for leaks. Alpha Pro Tec - General Boiler Information 5

16 3. DISPOSAL OF CONDENSATE Provision must be made for the safe disposal of condensate produced by Alpha Pro Tec boilers and reference should be made to BS 6798: 2000 for the requirements on the disposal of condensate. The boilers incorporate a condensate trap which has a seal greater than 75 mm, therefore no additional trap is required. The condensate should ideally be discharged internally into an internal waste pipe or soil pipe to avoid the possible risk of freezing. The pipework must be in at least 22 mm pipe. External pipe runs should be avoided, but if it is necessary, the pipework should be at least 32 mm and protected from the risk of freezing with waterproof insulation and the length should be kept to a maximum of 3 m. Termination should be into an external gulley or soakaway as shown in Figs. 3.6 and 3.7. Note: All pipework must have a continuous fall (see Figs. 3.6 and 3.7) from the boiler and must be of an acid resistant material such as plastic waste pipe, (copper or steel is not suitable). It should be noted that the connection of a condensate pipe to a drain may be subject to local building control requirements. Plastic pipe Use waterproof pipework insulation in very exposed positions Ensure pipe is adequately supported Open end of pipe diverted into gully below grid but above water level Minimum gradient 2½ Fig External gully 22mm termination from boiler Cement mortar sealing 500 mm min. O 2½ fall Ground level (either/or) 00mm plastic tube 25mm 300mm Bottom of tube sealed Soakaway depth 400mm filled with limestone chippings Two rows of 3 x 2mm holes at 25mm centres, 50mm from the bottom of the tube. Holes to face away from house. Fig External soakaway 6 Alpha Pro Tec - General Boiler Information

17 4 INSTALLATION 4. UNPACKING. The basic boiler is supplied in a single box, containing the following:- Cased boiler supplied with water connections and washers Mounting hooks and wall plugs with coach screws Tundish for pressure relief valve outlet Condensate discharge pipe Gas service cock and 28 mm connection tail Literature pack and Wall template Other parts of the flue system are supplied in separate packs as ordered. 2. Unpack boiler and remove the loose items. 4.2 DIMENSIONS and CONNECTIONS- Fig Pro Tec Dia E G 92 SV CD 30 HF HR E - Electrical connection G - Gas supply HR - Heating return HF - Heating flow CD - Condensate drain SV - Safety valve outlet (tundish) Fig. 4. Alpha Pro Tec - Installation 7

18 MINIMUM TOP CLEARANCE 350 mm TOP OF CASING WITH COVER BOILER MOUNTING HOOK FIXING HOLE MINIMUM SIDE CLEARANCE 0 mm BOTTOM OF CASING HEATING FLOW (/2" BSP) Dia. 50 E G 92 SV CD 30 HF HR SAFETY VALVE (3/4" BSP) MINIMUM BOTTOM CLEARANCE 250 mm GAS (28 mm) BOILER MOUNTING HOOK FIXING HOLE MINIMUM SIDE CLEARANCE 0 mm HEATING RETURN (/2" BSP) Pro Tec 70, 90, Dia. A Pro Tec 70 Pro Tec 90, 5 40 A 502 mm 632 mm 29 B C 265 mm 497 mm 40 mm 627 mm E G CD 3 HF SV HR B C E - Electrical connection G - Gas supply HR - Heating return HF - Heating flow CD - Condensate drain SV - Safety valve outlet (tundish) Fig PREPARE THE WALL - Fig Decide upon the position of the boiler taking into account the clearances required for servicing (refer to Section 2.2) and the flue terminal position. 2. Tape the template to the wall (ensure it is level and the right way up) and mark the position of the two holes for the boiler mounting hooks. 3. Drill the fixing holes (2 mm dia.) to accept the No. 2 plugs supplied. Screw the boiler mounting hooks fully into the plugs. 4. Cut suitable holes in the wall/roof 00 mm dia for open flue 80 mm dia. pipe or 27 mm dia. for concentric flue. Use the centre line positions given on the flue template. For side flue follow the horizontal line (ensuring at least a 25 mm/m fall towards the boiler) to the corner then 40 mm along the side wall to the centre of the hole for the flue. 5. Lift the boiler and locate it on the mounting hooks. Note: When handling or lifting always use safe techniques - keep your back straight, bend your knees, don't twist - move your feet, avoid bending forwards and sideways and keep the load as close to your body as possible. Where possible transport the boiler using a sack truck or other suitable trolley. Always grip the boiler firmly, and before lifting feel where the weight is concentrated to establish the centre of gravity, repositioning yourself as necessary. Centre line for horizontal concentric flue 70 mm Centre line for horizontal open flue Centre line for vertical flues Alpha Fig mm Top of casing with cover 8 Alpha Pro Tec - Installation

19 4.4 CONNECT THE PIPEWORK - Fig Thoroughly flush out all the system pipework. Refer to Section Connect the system flow and return pipework to the boiler using suitable isolating valves. Note: Do not forget that the pressure relief valve discharge pipe must be routed clear of the boiler to a drain in such a manner that it may be seen, but cannot cause injury to persons or property. 3. Connect the 22 mm condensate trap drain pipe to the condensate discharge pipe using the clip supplied. Ensure that the condensate discharge pipe is as required in Section 3.. Pour at least litre of water into the flue duct, as shown in Fig. 4.4, and check the condensate discharge pipe for soundness 4. Ensure that all the valves are closed and do not turn on the water or gas supplies at this stage. Fig 'B23' TYPE SINGLE PIPE 80 mm FLUE KITS Vertical kit - see Fig. 4.5 and 4.6, and refer to Section 3.4. Fig. 4.5 shows the vertical flue kit parts. To assemble the kit to the boiler - Slide the flue pipe down through the roof seal and place the seal over the flue duct. Push the flue duct into the flue socket on top of the boiler up to the stop. Ensure the seal is pushed in position against the ceiling. To install extensions or other flue components, proceed as follows: fit the male end of the pipe or elbow up to the stop on the female socket (with lip seals) of the previously installed component, this will ensure a secure fit and seal of the joints. Ensure all joints have the seal located correctly and the tape supplied is applied around each joint to ensure the flue ducts cannot be pulled apart. It is recommended that the flue should be supported at least every.5 m with access provided to the joints. Vertical terminal 430 mm Minimum Flue pipe L Max. Seal Seal L Max. Pro Tec 50 Pro Tec 70 Pro Tec 90 Pro Tec 5 30 m 28 m 4 m 8.5 m Fig. 4.5 Fig. 4.6 Horizontal through the wall kit - see Fig. 4.7 and 4.8, and refer to Section 3.4. Figs. 4.8 and 4.9 show the horizontal through the wall kit parts. To assemble the kit to the boiler - Fit the male end of the flue elbow into central flue outlet on the top of the boiler to the stop. Place the outer seal over the flue duct and slide it through the wall from the outside. Place the inner seal over the flue duct then insert the duct into the elbow up to the stop. Slide the seals along the duct to seal it to the inside and outside of the wall. To install extensions or other flue components, proceed as follows: fit the male end (smooth) of the pipe or elbow up to the stop on the female socket (with lip seals) of the previously installed component, this will ensure a secure fit and seal of the joints. Note: To prevent condensate lying in the flue pipe, slope the pipe towards the boilers with a minimum slope of (25-30 mm per metre). When installing the extensions, a wall/ceiling mounted clamp must be installed at least every.5 metres. Alpha Pro Tec - Installation 9

20 Flue elbow Flue pipe Inner seal Outer seal Fig mm L Max. 70 mm 00 mm Pro Tec 50 Pro Tec 70 Pro Tec 90 Pro Tec 5 L Max. 30 m 28 m 4 m 8.5 m Note: Ensure the flue slopes downwards towards the boiler by a minimum of 25 to 30 mm per metre (2.5 to 3 ) Fig 'C' TYPE CONCENTRIC FLUE KITS Convert the boiler from the factory supplied 'B23' type configuration to 'C' type, i.e. room sealed concentric flue by removing the 80 mm dia. adaptor and four screws securing the fixing plate and gasket from the top of the boiler. Horizontal through the wall concentric flue kit - see Fig. 4.9 and 4.0. Fig. 4.9 shows the flue kit parts that need to be fitted to the boiler to ensure the room sealed concentric flue can be used. To assemble the kit to the boiler - Fit the adapter into the central flue outlet on the top of the boiler up to the stop. Slide the square gasket over the adapter up to the groove, then fix it to the cover by means of the previously removed fixing plate and four screws. Fit the male end of the flue elbow up to the stop on the adapter. Place the outer seal over the concentric flue pipe and slide it through the wall from the outside. Place the inner seal over the concentric flue pipe then insert the pipe into the elbow up to the stop. Slide the seals along the duct to seal it to the inside and outside of the wall. To install extensions or other flue components, proceed as follows: fit the male end (smooth) of the concentric pipe or concentric elbow up to the stop on the female socket (with lip seals) of the previously installed component, this will ensure a secure fit and seal of the joints. Note: To prevent condensate lying in the flue pipe, slope the pipe towards the boilers with a minimum slope of 3 (25-30 mm per metre). When installing the extensions, a wall/ceiling mounted clamp must be installed every.5 metres. Flue elbow Fixing plate Inner seal Outer seal Square gasket Adapter Concentric flue pipe Fig Alpha Pro Tec - Installation

21 L Max. 36 mm 80 mm Inner seal Pro Tec 50 Pro Tec 70 Pro Tec 90 Pro Tec 5 L Max. 4.5 m m 8 m 5 m 200 mm Note: Ensure the flue slopes downwards towards the boiler by a minimum of 25 to 30 mm per metre (2.5-3 ) Outer seal Fig CONNECT THE MAINS SUPPLY AND EXTERNAL CONTROLS - Fig. 4.. Remove the case front panel as follows: a. Remove the two screws () from the bottom of the front panel (2). b. Grip the handle in the bottom of the panel and pull it forwards to detach it from the central catches (3) then slide it down from the top fixings (4) and remove. 2. Remove the two screws and washers (5) securing the sides of the control panel. Press the two side hooks (6) and tilt the control panel (7) forwards. Remove the three screws (8) securing the control box cover (9) to gain access to the terminal block. Refer to Technical Data, Section 2.6 for connection details. Note: This boiler has been fitted with a mains supply cable. However, if it is necessary to fit an alternative supply cable, ensure the cable clamp that has been fitted is removed and connect as follows:- Pass the mains supply cable through the cable clamp and connect as follows:- Brown to L, Blue to N and Green/Yellow to. Ensure correct polarity. Note: Ensure that the length of the earth wire is such that if the supply cable is pulled out of its clamp the live and neutral wires become taut before the earth wire. Do not switch on the electrical supply at this stage. 3. If any external control, i.e. room thermostat etc. is to be fitted, refer to Fig Do not connect 220/240 volts to any of the other terminals. 4. Ensure that there is sufficient free cable to allow the control panel to be raised and lowered then tighten the cable clamp screws. 5. Leave the control panel open until commissioning procedures have been completed. 6. Carry out electrical system checks - Short circuit, Polarity, Earth continuity and Resistance to earth with a suitable multimeter. Alpha Pro Tec - Installation 2

22 Fig Alpha Pro Tec - Installation

23 + 5 COMMISSIONING and USING THE BOILER When commissioning the boiler, ensure the Benchmark Checklist is completed. 5. FILL THE SYSTEM If the front cover has not been removed, refer to Section The Pro Tec 50 has two automatic air vents (see Fig. 6.2), the Pro Tec 70, 90, 5 boilers have one automatic air vent (see Fig. 6.3). Ensure that these are always open. 2. Open the central heating flow and return valves. 3. Open the fill point valve on the filling loop until water is heard to flow. 4. To remove the air - Vent each radiator in turn, starting with the lowest in the system. Note: The Pro Tec 50 model must be vented using the manual air vent on the top left of the heat exchanger (see Fig. 6.2). 5. It is important that the pump (see Fig. 6.2 or 6.3) is properly vented to avoid it running dry and damaging its bearings. Unscrew and remove the cap from the centre of the pump. Using a suitable screwdriver rotate the exposed spindle about half a turn, then replace the cap. 6. Check the operation of the safety valve (see Fig. 6.2 or 6.3) by turning the head anti-clockwise until it clicks. The click is the valve lifting off its seat allowing water to escape from the system - check that this is actually happening. 7. Continue to fill the system until the pressure gauge indicates.0 bar. Close the fill point valve and check the system for water soundness, rectifying where necessary. Disconnect the filling loop from the mains supply. If the system has been over pressurised water may be released from the system by manually operating the drain point (see Fig. 2.6 or 2.7) until the system design pressure is obtained. The system design pressure (cold) should be between 0.75 and.25 bar. Refer to Sections 3.9 and 3.0. Filling and Flushing the system. 5.2 TEST FOR GAS TIGHTNESS AND PURGE THE SUPPLY. With the boiler gas service cock closed. Pressure test the gas supply and inlet pipework connection to the boiler gas service cock for tightness in accordance with BS Loosen the gas inlet pressure test point screw on the gas valve (see Fig. 5.). Ensure the gas supply is on and open the boiler service cock to purge in accordance with BS Retighten the test point screw and test for gas tightness. Close the boiler gas service cock. Pro Tec 50, 70 gas valve Pro Tec 90, 5 gas valve P (P3) 3 P Inlet gas pressure point 2 - Outlet gas pressure point 3 - Off/Set adjustment screw (minimum) 4 - Outlet flow regulator (maximum) 2 (P3) Fig. 5. Alpha Pro Tec - Commissioning 23

24 5.3 BOILER CONTROLS - Fig. 5.2 Raise the control panel cover using the handle '3' in Fig ON 2 bar A B C RESET On/Off switch 2 - Main flow temperature - Increase or Decrease 3 - Control panel cover handle 4 - DHW temperature - Increase or Decrease (optional) 5 - System pressure gauge 6 - Summer/Winter mode selector button (A) 7 - Reset and information button (B) 8 - Hot water enable/disable button (C) 9 - LCD display 0 - Heating function - Numeric indicators - Temperature, Info and Fault codes 2 - Open Therm function 3 - Information icon 4 - Wireless feature 5 - Reset required 6 - Engineer mode for system setup 7 - Standby mode 8 - External temperature feature (optional) 9 - Measurement value units 20 - DHW function active (optional) 2 - DHW function disabled 22 - Burner ON 23 - Reset required 24 - Internal pump running 25 - Summer mode active Fig BOILER LCD DISPLAY AND CONTROL BUTTONS The boiler display (see Fig. 5.2), is composed of a 4-character display and 7 buttons. By using these buttons it is possible to adjust the boiler as it would be by using traditional selector switches and knobs. The function of each button is listed in Fig When the boiler is operating, the display indicates the mode icons and the boiler flow temperature. 5.5 INITIAL LIGHTING - Refer to Fig Ensure that the gas and electrical supplies to the boiler are off and that the heating flow and return valves are open. 2. Check that the system has been pressurised to the required pressure (at least bar). 3. Turn on the gas and electrical supplies to the boiler. 4. Ensure any external controls are calling for heat. 5. Set the On/Off switch to ON. The boiler pump will run through a brief air purging cycle. At the beginning of this cycle the display will check the software and connections. When the purge cycle is complete the boiler will then respond to the request of the heating controls and the burner will light if a demand is present. The boiler will only fire at low level initially and will ramp up gradually according to the heat demand. Allow the boiler to run and heat the circuit, checking for leaks and correct circulation, testing any secondary circuits and zone controls for correct operation. During operation gas working pressure and gas rate checks can be conducted using the engineering function. Refer to Section Alpha Pro Tec - Commissioning

25 'A' operating mode button( ) - With the boiler on, press button 'A' repeatedly to change the operating mode. It will switch from Summer mode ( ) (DHW heating only, when the optional kit is installed) to Winter mode (DHW and room heating), alternately. With the boiler on but not running, the screen will display the flow sensor temperature reading. A B C RESET Fig. 5.3 When the boiler switches on the relative symbols will be displayed and the flow sensor temperature reading shown. A B C RESET Fig. 5.4 Summer ( ) - In this mode the boiler only operates for DHW heating. By pressing the + or - buttons (as shown in Fig. 5.5) just once it is possible to read the temperature setting. By pressing them again you can change the settings as needed. You will need to press button 'B' to save the new value. The temperature reading will flash during adjustment. If a certain amount of time lapses without saving the value, the boiler will exit the setting mode and maintain the previous setting. A B C RESET Fig. 5.5 Winter ( ) - In this mode the boiler provides both DHW and room heating. By pressing the + or - buttons (as shown in Fig. 5.6) once, you can view the temperature setting. By pressing them again you can change the setting as needed. You will need to press button 'B' to save the new value. The temperature reading will flash during adjustment. If a certain amount of time lapses without saving the value, the boiler will exit the setting mode and maintain the previous setting. A B C RESET Fig. 5.6 Stand-by mode ( ) - By pressing buttons 'A' and 'C' (as shown in Fig. 5.7) at the same time it is possible to place the boiler in the standby mode. A B C RESET Fig. 5.7 In the standby mode the boiler is still switched on but not active, maintaining the anti-freeze function. To turn it back on simply press button 'B'. A B C RESET Fig. 5.8 Alpha Pro Tec - Commissioning 25

Installation and Servicing Instructions. Eco. Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boiler

Installation and Servicing Instructions. Eco. Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boiler Installation and Servicing Instructions Eco Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boiler For Technical help or for Service call... ALPHA HELPLINE Tel:

More information

Alpha InTec 12S, 18S, 28S

Alpha InTec 12S, 18S, 28S Installation and Servicing Instructions Alpha InTec 2S, 8S, 28S Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing System Boilers For Technical help or for Service

More information

Alpha CD13R,18R and 24R

Alpha CD13R,18R and 24R Installation and Servicing Instructions Alpha CD3R,8R and 24R Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Regular Boiler Range For Technical help or for Service call...

More information

Alpha InTec 30GS and 40GS

Alpha InTec 30GS and 40GS Installation and Servicing Instructions Alpha InTec 30GS and 40GS Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers with a Passive Flue Gas Heat Recovery

More information

User's Instructions. Alpha HE CB25/33 and HE SY25

User's Instructions. Alpha HE CB25/33 and HE SY25 User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:

More information

Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers

Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers Installation and Servicing Instructions Alpha 240/280 Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers For Technical help or for Service call... ALPHA HELPLINE Tel: 0870

More information

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet

More information

AquaNova. Water heater. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

AquaNova. Water heater. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER AquaNova Water heater Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims to improve the standards of installation

More information

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

For installation guide see reverse of book

For installation guide see reverse of book USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

Operating instructions

Operating instructions 6302 6959 02/2006 GB For the user Operating instructions Logano G215 WS Oil and gas-fired boilers Please read thoroughly before use. Overview Regulations and directives Installation: 90/396/EEC gas appliance

More information

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book USERS GUIDE LOGIC Heat 12, 15, 18, 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

Mikrofill Ethos Condensing combination boiler

Mikrofill Ethos Condensing combination boiler Mikrofill Ethos Condensing combination boiler Installation Instructions 24cc CE Mark No: 0201055 British Gas Service Listing G.C.No: 47-157-01 Mikrofill gas appliances comply with the requirements contained

More information

Combi 30 HE. Installation & Service Instructions

Combi 30 HE. Installation & Service Instructions Installation & Service Instructions Combi 30 HE Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Baxi Heating UK Ltd 2009 Natural Gas Main

More information

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009 Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25

More information

Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk

Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk 1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance

More information

ferroli Boiler Replacement Optimax HE- Modena HE

ferroli Boiler Replacement Optimax HE- Modena HE ferroli Boiler Replacement Optimax HE- Modena HE Introduction The new Ferroli Modena 32C HE high efficiency condensing combination boiler is an ideal replacement for the Ferroli Optimax HE 31 C and the

More information

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

MULTIPOINT BF Gas Fired Balanced Flue Water Heater Please leave these instructions with the user MULTIPOINT BF Gas Fired Balanced Flue Water Heater User Operating, Installation and Servicing Instructions 6 720 607 090 GB (04.10) JS Natural Gas Main Multipoint

More information

-- ---- I u SYSTEM BOILER. Central Heating Faned Flue system. Installation. System 40. System 60. heygfj& AA

-- ---- I u SYSTEM BOILER. Central Heating Faned Flue system. Installation. System 40. System 60. heygfj& AA -- ---- I u SYSTEM BOILER Central Heating Faned Flue system System 40 System 60 Installation Operating and instructions heygfj& v AA These instructions are suitable for the following boilers : Britony

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

Response: The combi boiler. Response: The fit anywhere combi

Response: The combi boiler. Response: The fit anywhere combi Response: The combi boiler The Ideal Response is a wall mounted, fanned flue combination boiler which serves a home's central heating system and delivers hot water on demand. It has been designed to be

More information

HALSTEAD. Best db 30/40/50/60 HALSTEAD INSTALLATION & SERVICING INSTRUCTIONS FOR THE

HALSTEAD. Best db 30/40/50/60 HALSTEAD INSTALLATION & SERVICING INSTRUCTIONS FOR THE INSTALLATION & SERVICING INSTRUCTIONS FOR THE HALSTEAD CAST IRON HALSTEAD Best db 0/40/50/60 WALL MOUNTED FAN ASSISTED BOILER B R I T I S H M A D E B O I L E R S Best 0 G. C. No. 4 50 Best 40 G. C. No.

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler

More information

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. 1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular

More information

Flue Installation. High Efficiency Condensing Boilers

Flue Installation. High Efficiency Condensing Boilers Flue Installation High Efficiency Condensing Boilers Table of contents INTRODUCTION 1 Instruction guidance...4 1.1 Product documentation...4 1.2 Explanation of symbols...4 1.3 Important Notes...4 INSTALLATION

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

Betacom. 24c G.C. No. 47-019-08. 30c G.C. No. 47-019-09. Installation and Servicing. High Efficiency Condensing Combination Boilers

Betacom. 24c G.C. No. 47-019-08. 30c G.C. No. 47-019-09. Installation and Servicing. High Efficiency Condensing Combination Boilers bar 3 4 5 2 6 1 7 24 8 23 9 22 10 21 11 20 12 19 13 18 14 17 16 15 Betacom Installation and Servicing 24c G.C. No. 47-019-08 30c G.C. No. 47-019-09 High Efficiency Condensing Combination Boilers ON 30

More information

Operators manual Basic water heater

Operators manual Basic water heater Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,

More information

Installation and Service Manual. Duo-tec Combi 24-28 - 33-40 28 LPG. Gas Fired Wall Mounted Condensing Combination Boiler

Installation and Service Manual. Duo-tec Combi 24-28 - 33-40 28 LPG. Gas Fired Wall Mounted Condensing Combination Boiler United Kingdom en Installation and Service Manual Gas Fired Wall Mounted Condensing Combination Boiler Duo-tec Combi 24-28 - 33-40 28 LPG These instructions include the Benchmark Commissioning Checklist

More information

Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options

Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options Flue Options Ace Finest Finest Gold Best 30/40/50/60 Best 80 Flue Options Flue Options Flue Options Flue Options B r i t i s h M a d e B o i l e r s Halstead have been manufacturing boilers in the UK since

More information

User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler

User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler You can rely on User Guide and Important Warranty Information Heatmax Combi HE Range Condensing Combination Boiler Please keep these instructions in a safe place. If you move house, please hand them over

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Mynute 25 A. High efficiency system boiler. Users Instructions. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Mynute 25 A. High efficiency system boiler. Users Instructions. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Mynute 25 A High efficiency system boiler Users Instructions Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims

More information

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions Part No. 130009 Iss. 12 August 2004 Elson www.elsonhotwater.co.uk Open Vented Thermal Store providing mains pressure hot water heated by electricity Installation, Servicing and User's Instructions Read

More information

INSTALLATION & TECHNICAL MANUAL

INSTALLATION & TECHNICAL MANUAL The COMET Range of Boilers the ultimate solution for central heating INSTALLATION & TECHNICAL MANUAL If you require any further assistance: Telephone: 01698 820533 Fax: 01698 825697 E-mail: info@electric-heatingcompany.co.uk

More information

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy

More information

Verve. High efficiency system boiler. Users Instructions. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Verve. High efficiency system boiler. Users Instructions. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Verve High efficiency system boiler Users Instructions Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims to

More information

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Baxi Combi Instant 8e & 15e Gas Fired Wall Mounted Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.

More information

Baxi Combi 80e & 105e

Baxi Combi 80e & 105e Baxi Combi 8e & 15e Please keep these instructions safe. Should you move house, please hand them over to the next occupier. Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Natural

More information

INDUSTRY GUIDANCE FOR INSTALLERS ON CONDENSATE DRAINAGE PIPE INSTALLATION. This guidance is endorsed by HHIC members.

INDUSTRY GUIDANCE FOR INSTALLERS ON CONDENSATE DRAINAGE PIPE INSTALLATION. This guidance is endorsed by HHIC members. 1. BACKGROUND INDUSTRY GUIDANCE FOR INSTALLERS ON CONDENSATE DRAINAGE PIPE INSTALLATION This guidance is endorsed by HHIC members. During recent winters the UK has experienced prolonged spells of extremely

More information

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1. Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1. Please read and understand these instructions before starting work. Please leave this leaflet

More information

Operating instructions

Operating instructions 6300 9681 02/2006 GB For the user Operating instructions Logano GE315 Boiler for oil-/gas-fired pressure jet burners Please read thoroughly before use. Operating instructions Logano GE315 Dear Customer,

More information

Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler User s Operating Instructions & Important Warranty Information Duo-tec Combi HE A Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions in a safe place. If you move

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R8202395-02EN - Edition 02-21/04/2005

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R8202395-02EN - Edition 02-21/04/2005 CUENOD Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CELTIC RSc b R8202395-02EN - Edition 02-21/04/2005 Boilers Solar Panel 69214511 31 CELTIC

More information

Instructions for installation and servicing ecomax

Instructions for installation and servicing ecomax For the installer Instructions for installation and servicing ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/2 E ecomax 68/2 E ecomax 622/2 E ecomax 635 E ecomax 824/2 E ecomax

More information

Spare Parts List M96A.24SM/B M96A.28SM/B

Spare Parts List M96A.24SM/B M96A.28SM/B *16202390* 162.0239.0 REV5 14/04 2015 Spare Parts List M96A.24SM/B M96A.28SM/B Issue Table description Issue n. of pages Overall view 09/2008 1 C.h. return group and d.h.w. heat exchanger 09/2008 1 C.h.

More information

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler User s Operating Instructions Baxi Combi 130 HE Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.

More information

Installation and Service Manual. Promax Combi 24-28 - 33. Condensing Combination Boiler

Installation and Service Manual. Promax Combi 24-28 - 33. Condensing Combination Boiler United Kingdom en Installation and Service Manual Condensing Combination Boiler Promax Combi 24-28 - 33 These instructions include the Benchmark Commissioning Checklist and should be left with the user

More information

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1 Visage Digital Digital diverter TM Installation guide Visage Digital diverter installation instructions Page 1 Visage Digital diverter Visage Digital concealed with adjustable and fixed head Visage Digital

More information

GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER

GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER Installation Instructions REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

Baxi Bahama 100 Gas Fired Wall Mounted Combination Boiler

Baxi Bahama 100 Gas Fired Wall Mounted Combination Boiler Baxi Bahama 100 Gas Fired Wall Mounted Combination Boiler Installation and Servicing Instructions BAXI Page 2 Natural Gas Baxi Bahama 100 G.C.Nº 47 075 02 Baxi Limited is one of the leading manufacturers

More information

Gas Instantaneous Water Heater

Gas Instantaneous Water Heater 6 720 607 884 (2009/05) GB Installation Manual and Operating Instructions Gas Instantaneous Water Heater WR8..P... WR11..P... With piezo ignition and double safety system consisting of flue gas monitor

More information

Visage. Digital. Exposed with adjustable height head. Visage Digital exposed installation instuctions page 1

Visage. Digital. Exposed with adjustable height head. Visage Digital exposed installation instuctions page 1 Visage Digital Exposed with adjustable height head The Waste Electrical and Electronic Equipment (Producer Responsibility) Regulation 2004 This product is outside the scope of the European Waste Electrical

More information

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

1. Description. 2. List of Accessories included A B C F G H

1. Description. 2. List of Accessories included A B C F G H 1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin. The unit will start automatically. Please pay particular attention to the following: Possible danger to

More information

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS Applied Energy Products Limited, Morley Way, Peterborough, PE2 9JJ, UK Telephone: +44 (0) 844 372 7761 / Fax: +44 (0) 84 372 7762 Website:

More information

Table of Contents. 1 List of Contents... 4 1.1 Contents included with ecomax pro boiler... 4

Table of Contents. 1 List of Contents... 4 1.1 Contents included with ecomax pro boiler... 4 To be left with the user Instructions for Use, Installation and Servicing ecomax pro GB Wall hung condensing boilers for traditional open vented systems 18 E 28 E Table of Contents Page 1 List of Contents.......................................

More information

User manual and Installation instructions

User manual and Installation instructions Wall hung, fanflue, roomsealed, high efficiency gas boiler User manual and Installation instructions Riva Plus HE Models G.C. Appl. No. M296.24SM/C 47-583-24 Combi boiler M296.28SM/C 47-583-25 Combi boiler

More information

User Manual THR840DUK Digital Thermostat

User Manual THR840DUK Digital Thermostat User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical

More information

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit. 1. Description The macerating system of this unit is installed in a case, specifically designed for horizontal outlet spigots. This macerator is manufactured in a factory which is quality certified to

More information

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler User s Operating Instructions & Important Warranty Information Baxi Platinum Combi HE Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house,

More information

G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating

More information

Stove-boiler for solid fuels 12-30 KW Directions for use and assembling

Stove-boiler for solid fuels 12-30 KW Directions for use and assembling Stove-boiler for solid fuels 12-30 KW Directions for use and assembling February 7, 2012 Contents 1 Technical data 2 1.1 Boiler properties TEMY PLUS 12-30 KW......................... 3 1.2 On Product............................................

More information

Link-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk

Link-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk Solid Fuel Association Guide to Central Heating Link-Up Combining solid fuel with other central heating technologies using various methods ranging from a simple link-up to a fully integrated thermal store

More information

ELECTRIC CENTRAL HEATING FLOW BOILER

ELECTRIC CENTRAL HEATING FLOW BOILER ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease The NEW Greenstar i innovative intuitive improved performance installation ease A NEW look, NEW features and a NEW NAME for the UK s best selling boiler, the Greenstar i Junior 1 Introducing the new Greenstar

More information

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S *1756202470* 17562.0247.0 REV3 06/09 2012 Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S Issue Table description Issue n. of pages Overall view 06/2009 1 C.h.

More information

HeatSource HS1800 Heater

HeatSource HS1800 Heater HeatSource HS1800 Heater Vehical Installation & Operating Instructions Propex Heatsource Ltd Unit 5, Second Avenue Buisness Park, Milbrook, Southampton, SO15 OLP Tel: 023 8052 8555 Fax: 023 8052 8800 Website:

More information

Instructions for Use Installation and Servicing. To be left with the user

Instructions for Use Installation and Servicing. To be left with the user Instructions for Use Installation and Servicing To be left with the user 0020013349-02.06.05 24cxi G.C. No. 47-047-23 12175 30cxi G.C. No. 47-047-24 38cxi G.C. No. 47-047-27 High Efficiency Condensing

More information

80-115 80-140 80-180 95-199 95-260 70-360 65-400 65-500

80-115 80-140 80-180 95-199 95-260 70-360 65-400 65-500 Release R.2.0 Uk 80-115 80-140 80-180 95-199 95-260 70-360 65-400 65-500 Installation User and Service Manual www.state-waterheaters.co.uk your installer Warning Read this manual carefully before first

More information

8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en

8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en 8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................

More information

GRANT. Vortex Condensing Oil Boilers. USER, INSTALLATION and SERVICING INSTRUCTIONS

GRANT. Vortex Condensing Oil Boilers. USER, INSTALLATION and SERVICING INSTRUCTIONS Part No. IRL 003 Rev. 02 May 2010 EFFICIENT HEATING SOLUTIONS GRANT Vortex Condensing Oil Boilers USER, INSTALLATION and SERVICING INSTRUCTIONS Indoor/Utility, System and Boiler House Models with outputs

More information

24CDi/28CDi/35CDi II RSF

24CDi/28CDi/35CDi II RSF Bosch Group 24CDi/28CDi/35CDi II RSF WALL MOUNTED COMBINATION BOILER FOR CENTRAL HEATING AND MAINS FED DOMESTIC HOT WATER INSTALLATION AND SERVICING INSTRUCTIONS 24CDi 28CDi 35CDi II GC NUMBER (N.G) 47

More information

Cooling system components, removing and installing

Cooling system components, removing and installing Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,

More information

NAVIEN AMERICA INC. 17855 FITCH AVENUE

NAVIEN AMERICA INC. 17855 FITCH AVENUE Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:

More information

Installation and Service Instructions. Neutralization System Part no. 7441823 Grünbeck part no. 410480

Installation and Service Instructions. Neutralization System Part no. 7441823 Grünbeck part no. 410480 Installation and Service Instructions for use by heating contractors Neutralization System Part no. 7441823 Grünbeck part no. 410480 Safety and Installation Requirements Please ensure that these instructions

More information

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table

More information

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................

More information

Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission Quinta Range Condensing Boilers REMEHA QUINTA RANGE High efficiency wall hung condensing boiler with ultra low NOx emission QUINTA RANGE OUTPUTS Q30: 5.6-28 kw Q45: 7-40 kw Q65: 11-61 kw Q85: 14.4-84.2

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

1 DESCRIPTION OF THE APPLIANCE

1 DESCRIPTION OF THE APPLIANCE 1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers

More information

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: This booklet should be left with the user after installation and demonstration Thank you for choosing a quality Redring product

More information

Getting the best from your urn

Getting the best from your urn 444448538 Standard 444448539 Deluxe Getting the best from your urn Remove any plastic film from the urn before use. Any water in the urn is due to testing and is normal. The urn must be used on a flat

More information

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:

More information

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,

More information

Vaillant s plain English guide to. simple, concise and precise

Vaillant s plain English guide to. simple, concise and precise Vaillant s plain English guide to simple, concise and precise Introduction Contents Installing a new boiler 05 Servicing and repairing 13 What s a diverter valve? Why do you need a TRV? And happens when

More information

Instructions for Use Installation and Servicing. To be left with the user

Instructions for Use Installation and Servicing. To be left with the user Instructions for Use Installation and Servicing To be left with the user 0020008155A.02.05 18sxi G.C. No. 41-047-72 12041 30sxi G.C. No. 41-047-62 High Efficiency Condensing System Boiler Glow-worm, Nottingham

More information

INSTRUCTIONS FOR INSTALLATION AND SERVICING TURBOmax VUW 242/1 E. TURBOmax VUW 282/1 E

INSTRUCTIONS FOR INSTALLATION AND SERVICING TURBOmax VUW 242/1 E. TURBOmax VUW 282/1 E INSTRUCTIONS FOR INSTALLATION AND SERVICING TURBOmax VUW / E TURBOmax VUW 8/ E Wall hung room sealed fan assisted combination boilers HEATING, CONTROLS, HOT WATER. Page. Introduction. Boiler Specification.

More information

Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html

Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html Installation / Operating Instructions GOOD.BEETER>BOSCH Water Wizard 600 Continuous Flow Gas

More information

INFRARED QUARTZ WALL HEATER

INFRARED QUARTZ WALL HEATER INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this

More information

Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB

Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB Gas Fired Cookers Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB FOR USE IN GB & IE PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING YOUR AGA Consumer Protection As responsible

More information

E-gas Instant Gas Water Heaters

E-gas Instant Gas Water Heaters The Proven Preferred Choice! E-gas Instant Gas Water Heaters Training & Information Manual: There are important functional and operational differences between the conventional hot water geyser and the

More information

SERVICE SERVICE MANUAL FOR ALDE ELECTRICAL HEATER

SERVICE SERVICE MANUAL FOR ALDE ELECTRICAL HEATER SERVIE SERVIE MNUL FOR LDE ELETRIL HETER 2737 2762 2763 ontents Page hap Title 3 1:0 Flow chart 4 2:0 bout the electrical heater 4 2:1 Technical data 4 3:0 General faultfinding 4 4:0 Faultfinding 4 4:1

More information

QUANTEC COMBI ErP. High Efficiency Combination Boiler. sustainable solutions under one roof INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS

QUANTEC COMBI ErP. High Efficiency Combination Boiler. sustainable solutions under one roof INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS sustainable solutions under one roof HEATING HOT WATER VENTILATION QUANTEC COMBI ErP High Efficiency Combination Boiler Publication No. ZZ 1432-6 September 2015 INSTALLATION, COMMISSIONING & SERVICING

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

GREENSTAR 60/100 HORIZONTAL FLUE

GREENSTAR 60/100 HORIZONTAL FLUE FLUE KIT INSTALLATION MANUAL 7 76 9 08 ROOM SEALED TELESCOPIC FLUE 7 76 9 7 ROOM SEALED LONGER TELESCOPIC FLUE 7 76 9 086 PLUME MANAGEMENT SYSTEM GREENSTAR 60/00 HORIZONTAL FLUE FOR WORCESTER GREENSTAR

More information