Automation Technology



Similar documents
Automation Technology

Hazardous Location. Products and Applications

Water and. Environmental Technology

TYPE APPROVAL CERTIFICATE

emobility WAGO Leading the Charge

TYPE APPROVAL CERTIFICATE

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

Heating, Ventilation and Air Conditioning

Solar Power. Industry Solutions

Current and Energy. Measurement Technology

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

S-series Electronic Marshalling

CANtrol EC Modular Control System Powerful and versatile

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Optimize your simple machines... Modicon M218 Selection Guide

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

S-series Mass Connection Solutions

Modular I/O system Rugged Modular I/O System Solutions EN certified for railway applications

Ponto Series. A new concept for automation

ABB RTU560A Series CMU & Modules

Application/Connection Examples

Industrial Bar Code Scanners

3500/22M Transient Data Interface

Inline The flexible I/O system for the control cabinet

Vorlesung Kommunikationsnetze Fieldbus Systems

Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8

Barcode Reader Series BCL 31, BCL 32, BCL 34

TO-PASS. TO-PASS -FAQ- Remote Monitoring. What is TO-PASS used for? What are the special functions of TO-PASS?

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

The Rail-Mounted Terminal Block System

WINSTA The Pluggable Connection System A Complete Range of Connectors

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Profibus DP Network with DeltaV/EMERSON Digital Automation System and Ponto Series Remote I/O

KNX IP: Breakthrough to more performance

EFC Frequency converters

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

S800 I/O Product Guide

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

NETWORK ENABLED EQUIPMENT MONITOR

applicomio Profibus-DP

GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0

Electronic Control Devices The European Product Catalogue 2007

Technical Information POWER PLANT CONTROLLER

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

M1000 Process Alarm Monitor

C ed P d ed b Em 184

Packaging Machines. Products and Applications

DeltaV S-series Traditional I/O

BC Bus Terminal Controller for PROFIBUS

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

ACOS 7 Series. Automation and Telecontrol Technology

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

Real pioneers don t know where to stop: Hirschmann explosion protection technology for hazardous locations.

The intelligent Protocol Converter

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

Modicon M340 The all-in-one PAC

ISpac isolators. the perfect system

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

How to make a diagnostic on TeSysT to start the network?

Electronic Control Devices The European Product Catalogue 2007

MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION

PCB TERMINAL BLOCKS. Product Overview

Using the WAGO PROFINET Coupler as Remote I/O with a Siemens S7 PLC

KNX Panasonic Air Conditioners

HARTING econ 3000 Introduction and features

Fieldbus slave modules with I/Os, DIO

Freelance Distributed process control system System description

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

EtherCAT P Ultra-fast Communication and Power in One Cable. One Cable Automation for the Field Level. EtherCAT US 24 V/3 A UP 24 V/3 A

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

sigpod Press ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS FEATURES

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Environmental data Temperature: -20 C to +55 C (Operating) -55 C to +85 C (Storage) Humidity: 0 95%

IntesisBox KNX Modbus TCP master

THE KNX IP CONTROLLER. Taking Proven Technology to the Next Level

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Industrial Bar Code Scanners

Unidirectional Transmitter/ Receiver Units Introduction

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Telephone- and leased line modem for industrial applications TD-36

MP85 / MP85DP. Data sheet. Special features MP85 / MP85DP. B en

Power supplies and UPS. For superior system availability

Telecontrol Technology with IEC 60870/61850/61400

38 Series - Relay interface modules A

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

Modbus Server SAMSUNG Air Conditioners

J TB/TW Temperature limiter, temperature monitor

Rack mounted telephone- and leased line modem for industrial applications

Transcription:

Automation Technology Full Line Catalog, Volume 3 Edition: 215 Approvals Overview WAGO-IO-SYSTEM 75753

WAGO Full Line Catalogs ms Syste lock inal B d Term ounte Rail-M e Full Lin 1 lume og, Vo Catal ition: 215 Ed Volume 1, Rail-Mounted Terminal Block Systems Rail-Mounted Terminal Blocks Rail-Mounted Terminal Blocks with Pluggable Connector (X-COM -SYSTEM and X-COM S-SYSTEM) Patchboard Systems Terminal Strips PUSH WIRE Connectors for Junction Boxes Lighting Connectors Shield Connecting System nd cks a lo inal B Term PCB ectors Conn 2 lume og, Vo 15 e Catal Edition: 2 Full Lin Volume 2, PCB Terminal Blocks and Connectors PCB Terminal Blocks SMD PCB Terminal Blocks MULTI CONNECTION SYSTEM (MCS) Pluggable PCB Terminal Blocks Feedthrough Terminal Blocks Specialty Connectors Empty Housings ation m Auto y olog Techn 3 lume og, Vo 15 e Catal Edition: 2 Full Lin Volume 3, Automation Technology Software Operating Monitoring - PERSPECTO Controllers Modular IO-SYSTEM, IP2IP67 Industrial Switches Radio Technology, TO-PASS Telecontrol Technology IP67 SensorActuator Boxes, IP67 Cables and Connectors Interf nic ectro ace El lume og, Vo 15 e Catal Edition: 2 Full Lin Volume, Interface Electronic Relay and Optocoupler Modules JUMPFLEX Signal Conditioners and Isolation Amplifiers Current and Energy Measurement Technology EPSITRON Power Supply System Interface Modules and System Wiring Overvoltage Protection Interface Modules with Specialty Functions Empty Housings ystem tion S A onnec WINST ggable C lu The P e Full Lin 5 lume og, Vo Catal ition: 215 Ed Volume 5, WINSTA The Pluggable Connection System WINSTA MINI Pluggable Connectors WINSTA MINI special Pluggable Connectors WINSTA MIDI Pluggable Connectors WINSTA MIDI special Pluggable Connectors WINSTA MAXI Pluggable Connectors WINSTA RD Cable Assemblies WINSTA KNX Pluggable Connectors WINSTA IDC Flat Cable Systems WINSTA Distribution Boxes

Approvals Overview WAGO-IO-SYSTEM 75753 Approvals for versions with item no. suffix...-... upon request. r C UL US E175199, UL 58 3-HG3786-PDA; 1-HN17753X 1353C BV, 3389A1 BV DNV (Det Norske Veritas) A-193, A-15 g GL (Germanischer Lloyd) 11 631-1 HH; 1971-11 HH; 26 62-5 HH; 26 898-5 HH; 7 311-12 HH; 59 627-8 HH; 6 21-9 HH; 61 626-13 HH; 95 3-1 HH; Cat. A, B, C, D (EMC 1) HMB588-AC1, -AC2, -AC3, -AC LR (Lloyd s Register) 2226 (E); Env. 1, 2, 3, RINA (Registro Italiano Navale) ELE13212XG 12.1297 X; 1.1911 X 7ATEX5586 X; IECEx TUN 9.1 X 12ATEX1632 X; IECEx TUN 12.39 X 1ATEX18929 X; IECEx TUN 1.35 X RINA PRS NKK LR KR GL DNV BV ABS PFC2 75-822 PFC2 CS 2ETH RS x x x 58 Fieldbus Controllers 1) 75-823 PFC2 CS 2ETH CAN x x x 56 75-82 PFC2 CS 2ETH RS CAN x x x x 5 75-826 PFC2 CS 2ETH RS CAN DPS x x x 52 75-8 INTERBUS Controller x x x x 1 75-86 DeviceNet Controller x x x x x x x x x x x x x 92 75-8153- MODBUS Controller, RS-85 (15 Bd... 115,2 kbd) x x x x x x x x x x 9 75-8163- MODBUS Controller, RS--232 (15 Bd... 115,2 kbd) x x x x x x x x x x 96 75-83 BACnetIP Controller x x x x x x x x x x x x 8 75-831 BACnetIP Controller x 82 75-833 PROFIBUS DPV1 Controller x x x x x x x x x x x x x 98 75-837 CANopen Controller, MSS x x x x x x x x x x x x x 1 75-838 CANopen Controller, D-Sub x x x x x x x x x 12 75-82 ETHERNET Controller 1 Mbits x x x x x x x x x x x x x 9 75-83 ETHERNET Controller 1 Mbits x x x x x x x x x x x x 88 75-852 ETHERNET ECO Controller x x 78 75-871 ETHERNET TCPIP Controller, 2 Ports x x x x x x x x x x x x Internet 75-872 Telecontrol Controller RJ-5 + D-Sub x x x 7 75-873 ETHERNET TCPIP RS-232 Controller x x x x x x x x x x x x 76 75-88 ETHERNET Controller x x x x x x x x x x x x 66 75-881 ETHERNET Controller x x x x x x x x x x x x 68 75-882 Media Redundancy ETHERNET Controller x x x x x x x x x x x x 72 75-88 Application Controller BA x x x Internet 75-885 Media Redundancy ETHERNET Controller x x x 7 75-838- CANopen Controller XTR x x x 11 75-88- ETHERNET Controller XTR x x x 112 75-88-1 ETHERNET Telecontroller XTR x x x 112 1) Notice: The 75-626 filter module is absolutely necessary for ship approval (note the power supply instructions)!

r C UL US E175199, UL 58 3-HG3786-PDA; 1-HN17753X 1353C BV, 3389A1 BV DNV (Det Norske Veritas) A-193, A-15 g GL (Germanischer Lloyd) 11 631-1 HH; 1971-11 HH; 26 62-5 HH; 26 898-5 HH; 7 311-12 HH; 59 627-8 HH; 6 21-9 HH; 61 626-13 HH; 95 3-1 HH; Cat. A, B, C, D (EMC 1) HMB588-AC1, -AC2, -AC3, -AC LR (Lloyd s Register) 2226 (E); Env. 1, 2, 3, RINA (Registro Italiano Navale) ELE13212XG Fieldbus Couplers 12.1297 X; 1.1911 X 7ATEX5586 X; IECEx TUN 9.1 X 12ATEX1632 X; IECEx TUN 12.39 X 1ATEX18929 X; IECEx TUN 1.35 X RINA PRS NKK LR KR GL DNV BV ABS 1) 75-33 PROFIBUS DP FMS 12 Mbaud x x x x x x x x x x x x 136 75-3 INTERBUS 5 kbaud x x x 172 75-36 DeviceNet x x x x x x x x x x x x 152 75-37 CANopen x x x 156 75-31 CC-Link x x x 18 75-3153- MODBUS, RS-85 (15 Bd... 115,2 kbd) x x x x x x x x x x 168 75-3163- MODBUS, RS-232 (15 Bd... 115,2 kbd) x x x x x x x x x x 17 75-331 PROFIBUS DP 1.5 MBaud (Optical Fiber) x 12 75-333 PROFIBUS DPV1 12 MBaud x x x x x x x x x x x x x 138 75-33 INTERBUS 5 kbaud (Optical Fiber) x x x 178 75-337 CANopen, MSS x x x x x x x x x x x x x 158 75-338 CANopen, D-Sub x x x x x x x x 16 75-3 PROFINET IO Coupler x x 128 75-32 ETHERNET TCPIP 1 Mbits x x x x x x x x x x x x x 16 75-33 PROFIBUS DP ECO 12 Mbaud x x x x x x x x x x x x x 1 75-3 INTERBUS ECO 5 kbaud x x x x 17 75-35 INTERBUS ECO 2 Mbaud x x x x 176 75-36 DeviceNet ECO x x x x 15 75-37 CANopen ECO, MSS x x x x x x x x x x x x x 162 75-38 CANopen ECO x x x x x x x x x x x x x 16 75-351 SERCOS III Coupler x x x x x x x x x x x 166 75-352 ETHERNET TCPIP 11 Mbits x x x x x x x x x x x x 1 75-35 EtherCAT x x x 18 75-37 PROFINET IO 1Mbit 2-port x x x 13 75-375 PROFINET IO adv. 2-Port x x 132 75-377 PROFINET IO adv. ECO 2-Port x x 13 75-333- PROFIBUS DPV1 12 Mbd XTR x x x 75-338- CANopen D-Sub XTR x x x 75-352- ETHERNET Fieldbus Coupler XTR x x x 2 Fieldbus Connectors 75-96 PROFIBUS Fieldbus connector with D-Sub male connector x x x x x x x x x x x x 63 75-961 INTERBUS Fieldbus connector with D-Sub female connector x x x 6 75-962 INTERBUS Fieldbus connector with D-Sub male connector x x x 61 75-963 CANopen Fieldbus connector with D-Sub connectors x x x x x x x x x x x 639 75-97 PROFIBUS Fieldbus connector with D-Sub female connector x x x x x x x x x x x Internet 75-975 ETHERNET RJ-5 connector x x x x x x x x x 637 75-976 PROFINET RJ-5 connector x 638 1) Notice: The 75-626 filter module is absolutely necessary for ship approval (note the power supply instructions)!

r C UL US E175199, UL 58 3-HG3786-PDA; 1-HN17753X 1353C BV, 3389A1 BV DNV (Det Norske Veritas) A-193, A-15 g GL (Germanischer Lloyd) 11 631-1 HH; 1971-11 HH; 26 62-5 HH; 26 898-5 HH; 7 311-12 HH; 59 627-8 HH; 6 21-9 HH; 61 626-13 HH; 95 3-1 HH; Cat. A, B, C, D (EMC 1) HMB588-AC1, -AC2, -AC3, -AC LR (Lloyd s Register) 2226 (E); Env. 1, 2, 3, RINA (Registro Italiano Navale) ELE13212XG Digital Input Modules 12.1297 X; 1.1911 X 7ATEX5586 X; IECEx TUN 9.1 X 12ATEX1632 X; IECEx TUN 12.39 X 1ATEX18929 X; IECEx TUN 1.35 X RINA PRS NKK LR KR GL DNV BV ABS 75-2DI 2V DC, 3.ms x* x* x* x* x* x* x* x* x* x* x* x* 186 75-1 2DI 2V DC,.2ms x* x* x* x* x* x* x* x* x* x* x* x* 186 75-2 DI 2V DC, 3.ms x* x* x* x* x* x* x* x* x* x* x* x* 189 75-3 DI 2V DC,.2ms x* x* x* x* x* x* x* x* x* x* x* x* 189 75-5 2DI 23V AC x* x* x* x* x* x* x* x* x* x* x* x* 21 75-6 2DI 12V AC x* x* x* x* x* x* x* x* x* x* x* x* 212 75-7 2DI 22 V DC x 211 75-8 DI 2V DC, 3.ms, low-side switching x* x* x* x* x* x* x* x* x* 192 75-9 DI 2V DC,.2ms, low-side switching x* x* x* 192 75-1 2DI 2V DC, 3.ms, proximity switching x* x* x* x* x* x* x* x* x* x* x* x* 187 75-11 2DI 2V DC,.2ms, proximity switching x* x* x* x* x* x* x* x* x* x* x* x* 187 75-12 2DI 8V DC, 3.ms x* x* x* 28 75-1 DI 5V DC,.2ms x x 18 75-15 DI 2V ACDC 2ms x* x x* x* x* x* x* x* x* x* x* x* x* 25 75-18 2DI 2V DC, 3.ms, diagn., acknol. x* x x* x* x* x* x* x* x* x* x* x* x* 188 75-21 2DI 2V DC, diagn. x* x* x* x* x* x* x* x* x* x* x* x* 188 75-22 2DI 2V DC, pulse extension x* x x* x* 191 75-23 DI 2V ACDC, 5ms, power contacts x* x x* x* x* x* x* x* x* x* x* x* x* 26 75-2 2DI 2V DC, intruder detection x* x x* x* x* x* x* x* x* x* x* x* x* 216 75-25 2DI NAMUR x* x x* x* x* x* x* x* x* x* x* x* x* 215 75-27 2DI 11V DC x* x x* x* 21 75-28 DI 2V ACDC, 2ms x* x* x* 27 75-3 8DI 2V DC, 3.ms x* x x* x* x* x* x* x* x* x* x* x* x* 195 75-31 8DI 2V DC,.2ms x* x x* x* x* x* x* x* x* x* x* x* x* 195 75-32 DI 2V DC x* x* x* x* x* x* x* x* x* x* x* x* 19 75-33 DI 2V DC x* x* x* x* x* x* x* x* x* x* x* x* 19 75-35 2) 1DI NAMUR Exi x x x x x x x x x x x x x 3 75-36 8DI 2V DC, 3.ms x* x* x* x* x* x* x* x* x* x* x* x* 196 75-37 8DI 2V DC,.2ms x* x* x* x* x* x* x* x* x* x* x* x* 196 75-38 2) 2DI NAMUR Exi x x x x x x x x x x x x x 36 75-39 2) 8DI NAMUR Exi x x x x x 38 75-1 16DI 2V DC 3.ms, high-side switch., ribbon cable x x x x x x x x x x x x 21 75-12 16DI 2V DC 3.ms, low-side switch., ribbon cable x x x x x x x x x x x x 23 75-15 16DI 2V DC 3.ms, high-side switch. x x x x x x x x x x x x 22 75-16 16DI 2V DC.2ms, high-side switch. x x x x x x x x 22 75-17 16DI 2V DC 3.ms, low-side switch. x x x x x x x x x x x x 2 75-115 8DI 2V DC, 3.ms, high-side switch., 2-conductor x x x x x x x x x x x x 199 75-116 8DI 2V DC,.2ms, high-side switch., 2-conductor x x x x x x x x x x x x 199 75-117 8DI 2V DC, 3.ms, low-side switch., 2-conductor x x x x x x x x x x x x 2 75-118 8DI 2V DC,.2ms, low-side switch., 2-conductor x x x x x x x x x x x x 2 75-12 DI 2V DC, 3.ms, high-side switch., 3-conductor x x x x x x x x x x x x 193 75-121 DI 2V DC,.2ms, high-side switch., 3-conductor x x x x x x x x x x x x 193 75-122 DI 2V DC, 3.ms, low-side switch., 3-conductor x x x x x x x x x x x x 19 75-123 DI 2V DC,.2ms, low-side switch., 3-conductor x x x x x x x x x x x x 19 75-125 8DI PTC x 217 753-29 2DI 6 V DC, 3. ms x x x 29 753-3 8DI 512V DC x x x x 185 753- DI 1223V AC x x x 213 75-7- 2DI 22V DC 3.ms XTR x x x 8 75-15- 16DI 2V DC 3.ms XTR x x x 7 75-115- 8DI 2V DC 3.ms, 2-wire connection XTR x x x 6 * Approval is also granted for the 753 Series pluggable IO modules 2) Only use this module in connection with the 2VDC Ex i supply module (note the power supply instructions!)

r C UL US E175199, UL 58 3-HG3786-PDA; 1-HN17753X 1353C BV, 3389A1 BV DNV (Det Norske Veritas) A-193, A-15 g GL (Germanischer Lloyd) 11 631-1 HH; 1971-11 HH; 26 62-5 HH; 26 898-5 HH; 7 311-12 HH; 59 627-8 HH; 6 21-9 HH; 61 626-13 HH; 95 3-1 HH; Cat. A, B, C, D (EMC 1) HMB588-AC1, -AC2, -AC3, -AC LR (Lloyd s Register) 2226 (E); Env. 1, 2, 3, RINA (Registro Italiano Navale) ELE13212XG Digital Output Modules 12.1297 X; 1.1911 X 7ATEX5586 X; IECEx TUN 9.1 X 12ATEX1632 X; IECEx TUN 12.39 X 1ATEX18929 X; IECEx TUN 1.35 X RINA PRS NKK LR KR GL DNV BV ABS 75-51 2DO 2V DC,.5A x* x* x* x* x* x* x* x* x* x* x* x* 222 75-52 2DO 2V DC, 2.A x* x* x* x* x* x* x* x* x* x* x* x* 223 75-5 DO 2V DC,.5A x* x* x* x* x* x* x* x* x* x* x* x* 226 75-56 2DO 2V DC,.5A, diagn. x* x* x* 22 75-58 2DO 2V DC, 2.A, diagn. x* x* x* x* x* x* x* x* x* x* x* x* 225 75-59 2DO 23V AC,.3A, SSR x* x* x* x* x* x* x* x* x* x* x* x* 22 75-512 2DO 23V AC, 2.A, rel. 2 NO x* x* x* x* x* x* x* x* x* x* x* x* 26 75-513 2DO 23V AC, 2.A, rel. 2 NO, pot. free x* x* x* x* x* x* x* x* x* x* x* x* 27 75-51 2DO 125V AC,.5A, rel. 2 CO, pot. free x* x* x* x* x* x* x* x* x* x* 2 75-516 DO 2V DC,.5A, low side switch x* x x* x* x* x* x* x* x* x* x* x* x* 228 75-517 2DO 23V AC, 1.A, rel. 2 CO, pot. free x* x* x* x* x* x* x* x* x* x* x* x* 25 75-519 DO 5V DC, 2mA x x x 22 75-522 2DO 23V AC, 3.A, 3s, SSR x x x x 23 75-523 1DO 23V AC, 16A, rel. 1a, pot. free x x x x x x x x x x 28 75-53 8DO 2V DC,.5A x* x x* x* x* x* x* x* x* x* x* x* x* 23 75-531 DO 2V DC,.5A x* x* x* x* x* x* x* x* x* x* x* x* 227 75-532 DO 2V DC,.5A, diagn. x x x x x x x x x x x x 229 75-53 8DO 512V DC x* x* x* x* 221 75-535 2) 2DO 2V DC, Ex i x x x x x x x x x x x x x 352 75-536 8DO 2V DC,.5A x* x* x* x* x* x* x* x* x* x* x* x* 231 75-537 8DO 2V DC,.5A, diagn. x* x* x* x* x* x x* x* x* x x* x* 232 75-538 2) 2DO RELAY Ex i x x x x x 35 75-15 16DO 2V DC.5A, high-side switch., ribbon cable x x x x x x x x x x x x 237 75-151 16DO 2V DC.5A, low-side switch., ribbon cable x x x x x x x x x x x x 239 75-152 8DI 8DO 2V DC.5A, high-side switch., ribbon cable x x x x x x x x x x x x 197 75-15 16DO 2V DC.5A, high-side switch. x x x x x x x x x x x x 238 75-155 16DO 2V DC.5A, low-side switch. x x x x x x x x x x x x 2 75-156 8DI 8DO 2V DC.5A, high-side switch. x x x x x x x x x x x x 198 75-1515 8DO 2V DC.5A, high-side switch., 2-conductor x x x x x x x x x x x x 235 75-1516 8DO 2V DC.5A, low-side switch., 2-conductor x x x x x x x x x x x x 236 753-5 DO 1223V AC x x x 21 75-58- 2DO 2V DC 2.ADiagnostics XTR x x x 9 75-517- 2DO 23V AC 1.A Relay 2COpotential-free XTR x x x 11 75-1515- 8DO 2V DC.5A, 2-wire connection XTR x x x 1 * Approval is also granted for the 753 Series pluggable IO modules 2) Only use this module in connection with the 2VDC Ex i supply module (note the power supply instructions!)

r C UL US E175199, UL 58 3-HG3786-PDA; 1-HN17753X 1353C BV, 3389A1 BV DNV (Det Norske Veritas) A-193, A-15 g GL (Germanischer Lloyd) 11 631-1 HH; 1971-11 HH; 26 62-5 HH; 26 898-5 HH; 7 311-12 HH; 59 627-8 HH; 6 21-9 HH; 61 626-13 HH; 95 3-1 HH; Cat. A, B, C, D (EMC 1) HMB588-AC1, -AC2, -AC3, -AC LR (Lloyd s Register) 2226 (E); Env. 1, 2, 3, RINA (Registro Italiano Navale) ELE13212XG Analog Input Modules 12.1297 X; 1.1911 X 7ATEX5586 X; IECEx TUN 9.1 X 12ATEX1632 X; IECEx TUN 12.39 X 1ATEX18929 X; IECEx TUN 1.35 X RINA PRS NKK LR KR GL DNV BV ABS 75-52 2AI 2mA, differential input x* x* x* x* x* x* x* x* x* x* x* x* 252 75-53 AI 2mA, single ended x* x* x* x* x* x* x* x* x* x* x* x* 259 75-5 2AI 2mA, differential input x* x* x* x* x* x* x* x* x* x* x* x* 252 75-55 AI 2mA, single ended x* x* x* x* x* x* x* x* x* x* x* x* 259 75-56 2AI ± 1 VDC x* x* x* x* x* x* x* x* x* x* x* x* 261 75-57 AI ± 1 VDC, single ended x* x* x* x* x* x* x* x* x* x* x* x* 267 75-59 AI -1 VDC, single ended x* x* x* x* x* x* x* x* x* x* x* x* 267 75-6 AI Resistance Temperature Device (RTD) x 27 75-61 2AI Resistance Temperature Device (RTD) x* x* x* x* x* x* x* x* x* x* x* x* 269 75-63 AI RTD-3 C... +15 C x x 271 75-6 2AI RTD, configurable x x x x x x x x x x x x 272 75-65 2AI 2mA, single ended x* x* x* 253 75-66 2AI 2mA, single ended x* x* x* 253 75-67 2AI 1 VDC, single ended x* x* x* 265 75-68 AI 1 VDC, single ended x x x x x x x x x x x 266 75-69 2AI Thermocouple (TC) diagn. x* x* x* x* x* x* x* x* x* x* x* 275 75-7 2AI 2mA, single ended, s.c. protec. x x x x x x x x x x x x 25 75-72 2AI 2mA, 16 bits, single ended x* x x* x* x* x* x* x* x* x* x* x* x* 255 75-73 2AI 2mA, single ended, s.c. protec. x x x x x x x x x x x x 25 75-7 2AI 2mA, 16 bits,single ended x* x x* x* x* x* x* x* x* x* x* x* x* 255 75-75 2AI 1A ACDC, differential input x* x x* x* x* x* x* x* x* x* x* x* x* 26 75-76 2AI ±1 VDC, 16 bits, single ended x* x x* x* x* x* x* x* x* x* x* x* x* 263 75-77 2AI 1V ACDC, differential input x* x* x* 26 75-78 2AI 1 VDC, 16 bits, single ended x* x x* x* x* x* x* x* x* x* x* x* x* 263 75-79 2AI ± 1 VDC, differential measurement input x* x x* x* x* x* x* x* x* x* x* x* x* 262 75-8 2AI 2mA, differential measurement input x* x x* x* 256 75-813- 2) 2AI RTD, Ex i x x x x x x x x x x x x x 36 75-82 2AI 2 ma 12 Bit single ended HART x* x* x* 258 75-83 2AI 3 VDC, differential measurement input x* x* x* x* x* x* x* x* x* x* x* x* 268 75-8 2) 2AI 2 ma 12 Bit single ended HART Ex i x x x x x x x x x x x x x 358 75-85 2AI 2mA, Ex i x x x x x x x x x x x x x 356 75-873- 2) 2AI TC, Ex i x x x x x x x x x x 362 75-92 2AI 2mA, differential measurement input x* x x* x* 257 75-93 3-Phase Power Measurement Module x x 277 75-9 3-Phase Power Measurement Module x x 278 75-53- AI -2mA S.E. XTR x x x 12 75-55- AI -2mA S.E. XTR x x x 12 75-57- AI ±1VDC S.E. XTR x x x 1 75-6- 2 AI RTD configurable XTR x x x 15 75-68- AI -1V DC S.E. XTR x x x 13 75-69- 2AI Thermocoupleconfigurable XTR x x x 16 * Approval is also granted for the 753 Series pluggable IO modules 2) Only use this module in connection with the 2VDC Ex i supply module (note the power supply instructions!)

r C UL US E175199, UL 58 3-HG3786-PDA; 1-HN17753X 1353C BV, 3389A1 BV DNV (Det Norske Veritas) A-193, A-15 g GL (Germanischer Lloyd) 11 631-1 HH; 1971-11 HH; 26 62-5 HH; 26 898-5 HH; 7 311-12 HH; 59 627-8 HH; 6 21-9 HH; 61 626-13 HH; 95 3-1 HH; Cat. A, B, C, D (EMC 1) HMB588-AC1, -AC2, -AC3, -AC LR (Lloyd s Register) 2226 (E); Env. 1, 2, 3, RINA (Registro Italiano Navale) ELE13212XG Analog Output Modules 12.1297 X; 1.1911 X 7ATEX5586 X; IECEx TUN 9.1 X 12ATEX1632 X; IECEx TUN 12.39 X 1ATEX18929 X; IECEx TUN 1.35 X RINA PRS NKK LR KR GL DNV BV ABS 75-55 2AO 1 VDC x* x* x* x* x* x* x* x* x* x* x* x* 285 75-552 2AO 2mA x* x* x* x* x* x* x* x* x* x* x* x* 282 75-553 AO 2mA x* x* x* x* x* x* x* x* x* x x* x* 28 75-55 2AO 2mA x* x* x* x* x* x* x* x* x* x* x* x* 282 75-555 AO 2mA x* x* x* x* x* x* x* x* x* x x* x* 28 75-556 2AO ±1 VDC x* x* x* x* x* x* x* x* x* x* x* x* 285 75-557 AO ± 1 VDC x* x* x* x* x* x* x* x* x* x* x* x* 287 75-559 AO -1 VDC x* x* x* x* x* x* x* x* x* x* x* x* 287 75-56 2 AO -1 VDC 1 bits 1 ma 2V x x x 288 75-562 2AO ±1 VDC 16 bits x x x 286 75-563 2AO -2 ma 6-18 VDC 16 bits x x x x 283 75-585 2) 2AO 2mA, Ex i x x x x x x x x x x x x x 36 75-586 2) 2AO 2mA, Ex i x x x x x 36 75-557- AO ± 1V DC XTR x x x 18 75-559- AO -1V DC XTR x x x 18 75-563- 2 AO -2mA 6-18VDC configurable XTR x x x 17 * Approval is also granted for the 753 Series pluggable IO modules 2) Only use this module in connection with the 2VDC Ex i supply module (note the power supply instructions!)

r C UL US E175199, UL 58 3-HG3786-PDA; 1-HN17753X 1353C BV, 3389A1 BV DNV (Det Norske Veritas) A-193, A-15 g GL (Germanischer Lloyd) 11 631-1 HH; 1971-11 HH; 26 62-5 HH; 26 898-5 HH; 7 311-12 HH; 59 627-8 HH; 6 21-9 HH; 61 626-13 HH; 95 3-1 HH; Cat. A, B, C, D (EMC 1) HMB588-AC1, -AC2, -AC3, -AC LR (Lloyd s Register) 2226 (E); Env. 1, 2, 3, RINA (Registro Italiano Navale) ELE13212XG Function, Technology and Communication Modules 12.1297 X; 1.1911 X 7ATEX5586 X; IECEx TUN 9.1 X 12ATEX1632 X; IECEx TUN 12.39 X 1ATEX18929 X; IECEx TUN 1.35 X RINA PRS NKK LR KR GL DNV BV ABS 75- Updown counter, 1kHz x* x* x* x* x* x* x* x* x* x* x* x* 292 75-511 2 DO, 2 VDC,.1A, pulse width x x x 29 75-63 SSI transmitter interface x x x x 295 75-631- Incremental encoder interface, 16 bits x x 296 75-632 Proportional Valve Module x x x 31 75-633 2) Updown counter Ex i x x x x x x 366 75-635 Digital pulse interface x* x x* x* 298 75-637 Incremental encoder interface, 32 bits x x x x x x x x x x x x x 297 75-638 Updown counter, 5kHz x* x x* x* 293 75-6 RTC Module x x x 299 75-62 Radio receiver module x x x 319 75-63 MP-Bus Master module x x x 323 75-6 Bluetooth RF Transceiver x x x 318 75-65 2AI2DO VIB VRMSSPM Multi x x x 31 75-65 Serial interface RS-232 C x* x* x* x* x* x* x* x* x* x* x* x* 31 75-651 TTY interface x x x x x x x x x x x 317 75-652 RS-232RS-85 configurable x* x* x* x* x* x x* x* x* x x* x* 316 75-653 Serial interface RS-85 x* x* x* x* x* x* x* x* x* x* x* x* 315 75-65 Data exchange module x x x x x x x x x x 329 75-655 AS-Interface Master x* x* x* x* x* x* x* x* x* x* x* x* 32 75-657 -Channel IO-Link Master x 326 75-658 CAN Gateway x x x 328 75-66-1 PROFIsafe 8 DI x x x 332 75-661-3 PROFIsafe FDI 2V x* x* x* x* 333 75-662-3 PROFIsafe 8 FDI 2 V x* x* x* x* 33 75-663-3 F Ex i DI 2V PROFIsafe V2 ipar x x x x x 338 75-665-1 PROFIsafe FDO.5 A; FDI 2V DC x x x 335 75-666-3 PROFIsafe FDI2 FDO 2V1A x* x* x* 336 75-667-3 PROFIsafe FDI FDO 2V2A x* x* x* x* 337 75-67 Stepper Controller RS-222V2mA x x x 32 75-671 Stepper Controller 2V1.5A x 33 753-66 KNXEIBTP1 module x x x x x x x x x x 32 753-67 DALI Multi-Master Module x 321 753-68 LON FTT Module x 322 75-652- RS-232RS-85 freely configurable XTR x x x 19 * Approval is also granted for the 753 Series pluggable IO modules 2) Only use this module in connection with the 2VDC Ex i supply module (note the power supply instructions!)

r C UL US E175199, UL 58 3-HG3786-PDA; 1-HN17753X 1353C BV, 3389A1 BV DNV (Det Norske Veritas) A-193, A-15 g GL (Germanischer Lloyd) 11 631-1 HH; 1971-11 HH; 26 62-5 HH; 26 898-5 HH; 7 311-12 HH; 59 627-8 HH; 6 21-9 HH; 61 626-13 HH; 95 3-1 HH; Cat. A, B, C, D (EMC 1) HMB588-AC1, -AC2, -AC3, -AC LR (Lloyd s Register) 2226 (E); Env. 1, 2, 3, RINA (Registro Italiano Navale) ELE13212XG Supply and Segment Modules 12.1297 X; 1.1911 X 7ATEX5586 X; IECEx TUN 9.1 X 12ATEX1632 X; IECEx TUN 12.39 X 1ATEX18929 X; IECEx TUN 1.35 X RINA PRS NKK LR KR GL DNV BV ABS 75-6 End module x x x x x x x x x x x x 39 75-61 3) Supply module 2 VDC fuse x x x x x x x x x x x x 371 75-62 3) Supply module 2 VDC x* x* x* x* x* x x* x* x* x x* x* 37 75-63 Field side connection module x* x* x* x* x* x* x* x* x* x* x* 377 75-6 Field side connection module x* x* x* x* x* x* x* x* x* x* x* 378 75-66 Supply module 2 VDC Ex i x x x x x x x x x x x x x 32 75-69 Supply module 23 VAC fuse x x x x x x x x x x x x 371 75-61 3) Supply module 2 VDC fuse diagn. x x x x x x x x x x x x 372 75-611 Supply module 23 VDC fuse diagn. x x x x x x x x x x x x 372 75-612 ) Supply module -23 V ACDC x* x* x* x* x* x x* x* x* x x* x* 37 75-613 1) Internal system supply module 2 VDC x x x x x x x x x x x x 37 75-61 Field side connection module, - 23 V ACDC x* x* x* x* x* x* x* x* x* x* x* x* 376 75-615 Supply module 12 VAC fuse x x x 371 75-616 Separation module x x x x x x x x x x x x 389 75-617 Supply module 2 VAC fuse x x 371 75-621 Separation module with contacts x x x 389 75-622 Binary spacer module with power supply x x x 386 75-623 Supply module 25-15 VDC x x x x x x x x x 373 75-62 Overvoltage protection, field side power supply x x x x x x x x x x x x 382 75-625-1 Supply module 2 VDC Ex i x x x x x x x x x x x x x 32 75-626 Filter module, system and field side power supply x x x x x x x x x x x x 383 75-627 Internal Data Bus Extension End Module x x x 38 75-628 Internal Data Bus Extension Coupler Module x x x 385 75-165 Field side connection module x x x x x x x x x x x x 379 75-166 Field side connection module x x x x x x x x x x x x 38 75-167 Field side connection module x x x x x x x x x x x x 381 753-62 DALI Multi-Master DCDC Converter x 375 753-6292- Spacer Module passive x 388 753-1629 Spacer Module active x 387 75-6- End Module XTR x x x 27 75-62- 2VDC Power Supply XTR x x x 2 75-612- -23V ACDC Power Supply XTR x x x 21 75-613- 2VDC Bus Power Supply XTR x x x 22 75-62-1 Overvoltage protection, field side power supply XTR x x x 23 75-626- Filter module, system and field side power supply XTR x x x 2 75-165- Field-Side Connection Module 16+ XTR x x x 25 75-166- Field-Side Connection Module 16- XTR x x x 26 * Approval is also granted for the 753 Series pluggable IO modules 1) Notice: The 75-626 filter module is absolutely necessary for ship approval (note the power supply instructions)! 3) Notice: The 75-62 filter module is absolutely necessary for ship approval (note the power supply instructions)! ) Notice: The 75-626 filter module is absolutely necessary for ship approval at 2VDC power supply (note the power supply instructions)!

r C UL US E175199, UL 58 3-HG3786-PDA; 1-HN17753X 1353C BV, 3389A1 BV DNV (Det Norske Veritas) A-193, A-15 g GL (Germanischer Lloyd) 11 631-1 HH; 1971-11 HH; 26 62-5 HH; 26 898-5 HH; 7 311-12 HH; 59 627-8 HH; 6 21-9 HH; 61 626-13 HH; 95 3-1 HH; Cat. A, B, C, D (EMC 1) HMB588-AC1, -AC2, -AC3, -AC LR (Lloyd s Register) 2226 (E); Env. 1, 2, 3, RINA (Registro Italiano Navale) ELE13212XG Infrastructure 12.1297 X; 1.1911 X 7ATEX5586 X; IECEx TUN 9.1 X 12ATEX1632 X; IECEx TUN 12.39 X 1ATEX18929 X; IECEx TUN 1.35 X RINA PRS NKK LR KR GL DNV BV ABS 852-11 5-Port 1BASE-TX Industrial Switch x 528 852-12 8-Port 1BASE-TX Industrial Switch x 529 852-13 82 Port 1BASE-TXFX Industrial Switch x 53 852-111 5-Port 1BASE-TX Industrial Eco Switch x 5) x 532 852-112 8-Port 1BASE-TX Industrial Eco Switch x 533 852-33 82-Port 1BASE-TX1BASE SXLX x Internet Industrial Managed Switch 852-1111 5-Port 1BASE-T Industrial Eco Switch x 5) 53 852-135 8-Port 1Base-T1BASE SXLX x Internet Industrial Managed Switch 5) DNV only with 852-911 Carrier Rail Adapter

888-63-691-691 Automation Technology 215 US 7215-3 Printed in Germany Subject to design changes WAGO Kontakttechnik GmbH Co. KG Postfach 288 D - 32385 Minden Hansastraße 27 D - 3223 Minden Germany Phone: +9 571 887 - Fax: +9 571 887-169 E-Mail: info@wago.com Online: www.wago.com