Trinity Feature: DSL Configuration



Similar documents
Trinity Feature: T1/E1 Configuration

V101. VDSL LAN Extender

Exam questions. 1. Which of the following are true regarding xdsl? Choose three. It uses a portion of the existing phone line.

Technote. SmartNode Quality of Service for VoIP on the Internet Access Link

Monitoring and Testing

VDSL2 LAN Extender User Manual

PARADISE DATACOM APPLICATION NOTE CONTROL AND MONITOR OF DISTANT END TERMINAL USING LOCAL MODEM WEB USER INTERFACE EVO_AN_001

Chapter 4 T1 Interface Card

Actiontec V1000W VDSL Gateway Static Business Class

! encor en etworks TM

This techno knowledge paper can help you if: You need to setup a WAN connection between a Patton Router and a NetGuardian.

T1 Networking Made Easy

SHDSL LAN EXTENDER H301A. User Manual

Long Range Ethernet Extender

NetVanta Series (with Octal T1/E1 Wide Module)

Configuring T1 and E1 WAN Interfaces

ADSL WAN Connections. Contents

Digital Subscriber Line (DSL) Transmission Methods

Voice Over IP Per Call Bandwidth Consumption

How To Check If Your Router Is Working Properly On A Nr854T Router (Wnr854) On A Pc Or Mac) On Your Computer Or Ipad (Netbook) On An Ipad Or Ipa (Networking

Ethernet over VDSL2 PoE PD Converter

Acterna DSL Services Tester TPI 350+ Application Highlights

Cisco 8-Port Channelized T1/E1 Shared Port Adapter

Broadband 101: Installation and Testing

1. Overview. 2. F-bit Utilization

Data Link Protocols. TCP/IP Suite and OSI Reference Model

MLPPP Deployment Using the PA-MC-T3-EC and PA-MC-2T3-EC

T3 Mux M13 Multiplexer

Building a Bigger Pipe: Inverse Multiplexing for Transparent Ethernet Bridging over Bonded T1/E1s

How To Set Up A Netvanta For A Pc Or Ipad (Netvanta) With A Network Card (Netvina) With An Ipa (Net Vanta) And A Ppl (Netvi) (Netva)

Detecting Bridged Tap and Noise Interference in VDSL2 Access Networks using the JDSU SmartClass TPS

BroadCloud Adtran Total Access Quick Start Guide

OSBRiDGE 5XLi. Configuration Manual. Firmware 3.10R

DSL Variations. NEXTEP Broadband White Paper. Broadband Networks Group. Definitions and differences of Digital Subscriber Line variations.

TD-8610/TD-8610B External ADSL2+ MODEM

Public Switched Telephone System

IEX-402-SHDSL Series Quick Configuration Guide First Edition, January 2013

How To Switch In Sonicos Enhanced (Sonicwall) On A 2400Mmi 2400Mm2 (Solarwall Nametra) (Soulwall 2400Mm1) (Network) (

IP videoconferencing solution with ProCurve switches and Tandberg terminals

NetVanta 3000 Series (with T1/FT1 or T1/FT1 with DSX-1 Network Interface Module)

Chapter 2 - The TCP/IP and OSI Networking Models

Speed-DSL 9.2 Ethernet connection over 8-wires up to 9.2 Mbit/s. Manual * * * *

Introduction to ADSL. NEXTEP Broadband White Paper. Broadband Networks Group. A primer on Asymmetric Digital Subscriber Line transmission technology.

Cisco 2-Port and 4-Port Channelized T3 (DS-0) Shared Port Adapters

TNE1500-P and TNE1500-S Single Line T1 Network Extender Provider and Subscriber

CAMPUS-RS CSU/DS-1 INTERFACE CARDS

LevelOne User Manual VDS-0120 Ethernet over VDSL2 Converter (PSE)

Nokia Siemens Networks. CPEi-lte User Manual

IP Router QUICK START GUIDE

Appendix C Network Planning for Dual WAN Ports

Cisco CCNA Optional Semester 4 Labs Wide Area Networking LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes)

SAGEM TM 800 (PPP) User Guide October 2002 Issue

TAM Port T1 Access Multiplexer

16-PORT POWER OVER ETHERNET WEB SMART SWITCH

BroadCloud PBX Customer Minimum Requirements

Extending Ethernet over 2-wire Copper Networks

Terminal Server Router QUICK START GUIDE

Talk2M ewon Internet Connection How To

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

RADview/TDM. Element Management System for TDM Applications Optimux-T RAD Data Communications Publication 06/05

WEB RANger-II Internet Access Router

Appendix A QUICK Specifications

LOHU 4951L Outdoor Wireless Access Point / Bridge

What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France

Black Box Explains: DSL

WANPIPE TM. Multi-protocol WANPIPE Driver CONFIGURATION M A N U A L. Author: Nenad Corbic/Alex Feldman

CTS2134 Introduction to Networking. Module 07: Wide Area Networks

Chapter 6 Using Network Monitoring Tools

How To Check If Your Router Is Working Properly

Chapter 6 Bandwidth Utilization: Multiplexing and Spreading 6.1

Configuring E1 and T1 Interfaces

Digital Subscriber Line (DSL)

CONTRIBUTION ABSTRACT

Gigabit Ethernet Turn-up Procedure using the JDSU T-BERD 8000 or T-BERD 6000A March 4, 2009

N560 series H/W Installation Guide

bintec Workshop WAN Partner Configuration Copyright November 8, 2005 Funkwerk Enterprise Communications GmbH Version 0.9

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

Load Balance Mechanism

WAN Data Link Protocols

DigiPoints Volume 1. Student Workbook. Module 4 Bandwidth Management

Configuring the Channelized 12-port CT3/T1 Optical Services Modules

CS263: Wireless Communications and Sensor Networks

TD-8810 External ADSL2+ Router

Opportunities and techniques for power saving in DSL

Adtech Data Link Simulators.

LAN Switching Computer Networking. Switched Network Advantages. Hubs (more) Hubs. Bridges/Switches, , PPP. Interconnecting LANs

DSA800 Series Spectrum Analyzer

NEW WORLD TELECOMMUNICATIONS LIMITED. 2 nd Trial Test Report on 3.5GHz Broadband Wireless Access Technology

Common Application Guide

Network Requirements for DSL systems, (ADSL through G.Fast) (A summarized view)

Configuring E1 and T1 Interfaces

Acer ADSL Surf USB Modem

ANT-20, ANT-20E Advanced Network Tester PDH MUX/DEMUX

24-Port Channelized E1/T1 Line Card Overview

SAGEM TM 800 / 840 (PPP) User Guide June 2005 Issue

Technology Brief. Implementing DSL Service for ISPs with the SMS. The DSL Opportunity. DSL is Different from Dial

Chapter 2 Connecting the FVX538 to the Internet

Transcription:

Trinity Feature: Reference Guide Appendix Sales Office: +1 (301) 975-1000 Technical Support: +1 (301) 975-1007 E-mail: support@patton.com WWW: www.patton.com Part Number: 07MTRINDSL-APD, Rev. C Revised: February 24, 2012

Patton Electronics Company, Inc. 7622 Rickenbacker Drive Gaithersburg, MD 20879 USA tel: +1 (301) 975-1000 fax: +1 (301) 869-9293 support: +1 (301) 975-1007 web: www.patton.com e-mail: support@patton.com Copyright Copyright 2012, Patton Electronics Company. All rights reserved. Notice The information in this document is subject to change without notice. Patton Electronics assumes no liability for errors that may appear in this document. The software described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license.

Appendix Chapter contents Overview...4 Configuration Overview...4 Web Management Interface (WMI)...5 Configure DSL Ports...5 Manage DSL Ports and PPP Interfaces...6 Command Line Interface (CLI)...7 Viewing Statistical Information...7 Example...8 3

Overview This chapter describes how to configure DSL settings. Some models with the Trinity platform offer a G.SHDSL port on the back of the device. Each DSL interface is capped with a PPP interface that is routed or bridged out an Ethernet interface or another WAN service. In this way, the device is a DSL Access Multiplexer or DSLAM. Note The menu, commands, and features for your model may vary slightly from what is shown in this manual. Some models may not include all of the features mentioned. Refer to the model s User Manual, available online at www.patton.com/manuals, to see which features are available. Configuration Overview When the unit boots, it creates Data Channels for each DSL interface (i.e. dsl0, dsl1,..., dsl23). Data Channels are automatically available to bind to PPP interfaces. See the PPP Configuration chapter in the TrinityAE Administrator s Reference Guide (available online at www.patton.com/manuals/trinity-arg.pdf) for details on how to configure PPP. The unit allows each DSL interface to be configured independently with the following settings: bandwidth, terminal type, annex, and link state. G.SHDSL defines bandwidth (speed) in terms of 64kbps increments called timeslots. There is a minimum of 3 (192kbps) and a max of 36 (2.3Mbps). It also defines two annexes which are the frequency spectrum used to transmit data. The spectrum for Annex A relates directly to the spectrum used for T1 and Annex B relates directly to E1. The final configuration value is link state, which can be up or down. When the link is up, the DSL interface will attempt to establish a DSL connection regardless of whether it is physically connected or not. When the link is down, the DSL will not attempt to establish nor will it respond to attempts to establish a DSL connection. When linking, the unit will always attempt to use G.Handshake to negotiate line speed; this cannot be disabled. In CO mode, the configured bandwidth is the max possible bandwidth, but it could negotiate a lower value if the signal to noise ratio is to high. In CPE mode, the configured bandwidth is ignored. To configure DSL through the WMI, see the section Web Management Interface (WMI) on page 5. To configure DSL through the CLI, see the section Command Line Interface (CLI) on page 7. Overview 4

Web Management Interface (WMI) To access the G.SHDSL Management page, click on Interface Configuration > DSL from the main menu on the left of the screen. Figure 1. G.SHDSL Management main page Configure DSL Ports To configure a DSL port: 1. Click on the port number in the G.SHDSL Status table. The G.SHDSL Port Management page displays. Figure 2. G.SHDSL Port Configuration 2. Select the Enable checkbox to begin training the link. 3. From the Terminal Type drop-down menu, set the DSL as CO (Central) or CPE (Remote). 4. Select the desired speed value (including timeslots) from the Speed drop-down menu. Web Management Interface (WMI) 5

5. Select A or B from the Annex drop-down menu. 6. Enter a Description for the port (optional). 7. Click Update. Note A DSL port cannot be configured while it is bound to a PPP interface. Manage DSL Ports and PPP Interfaces To manage DSL ports and PPP interfaces, click on PPP in the main navigation menu on the left side of the screen. Then, select the PPP interface to manage. DSL ports display as PPP devices. Figure 3. DSL Ports and PPP To bind a DSL port to a PPP interface: 1. On the PPP interface page, select the Enabled checkbox in the Select Devices section. 2. If you want to bind multiple ports, select the Multilink (MLPPP) checkbox. 3. Select the Bind checkbox for the desired DSL port(s). 4. Click Update to enable your changes. To unbind a DSL port from a PPP interface: 1. On the PPP interface page, deselect the Enabled checkbox in the Select Devices section. 2. Deselect the Bind checkbox for the desired DSL port(s). 3. Click Update to enable your changes. Note For more detailed information on PPP, refer to the PPP Configuration chapter in the TrinityAE Administrator s Reference Guide (available online at www.patton.com/manuals/trinity-arg.pdf). Web Management Interface (WMI) 6

Command Line Interface (CLI) Step Table 1. DSL - CLI Commands 1 Trinity#configure Enter configure mode. 2 Trinity[config]#interface dsl <number> 3 Trinity[dsl-0]# set {annex {a b} timeslot <number> type {central remote}} Explanation Enter the configuration mode for dsl number, where number is between 0 and 23. Sets various attributes of the DSL. set annex {a b} Sets the annex to A or B. set timeslot <number> Sets the number of timeslots to use. Valid values are 3-36. set type {central remote} Sets the DSL to CO (central) or CPE (remote). 4 Trinity[dsl-0]# [no] shutdown Enables or Disables a DSL interface. Viewing Statistical Information The following statistical information is available for each DSL. The information can be acquired via the show interface dsl [<number>] command or via the show command while configuring the DSL interface. Note Statistics are only accurate when the DSL is linked. DSL link state as configured vs. DSL link state in reality Number of links vs. Number of attempts to link Noise on the line in 0.5dB increments Far End Attenuation in 0.5dB increments Link up-time Terminal type as configured (CO or CPE) Speed/timeslots as negotiated Speed/timeslots as configured (only shown if different from negotiated value) Annex as configured (A or B) General Errors - Loss Of Signal errors - Cyclic Redundancy Check errors - Digital Phased Locked Loop errors Command Line Interface (CLI) 7

Rx Errors - Full buffer errors - Empty buffer errors - Buffer Slip errors Tx Errors - Full buffer errors - Empty buffer errors - Buffer Slip errors - Number of Stuff Bits injected Example Trinity[dsl-4]# show DSL 4 is up, link is up 4 links in 10 attempts 20.0dB noise, 0.0dB far end atten. Link active for 5 seconds Terminal type is central (CO) Speed is 1024kbps (16 timeslots) configured as 2304kbps (36 timeslots) Annex is A General Errors 5 LOS, 4 CRC, 0 DPLL Rx Errors 1 full, 0 empty 0 slip Tx Errors 0 full, 0 empty 0 slip, 0 stuff bits Command Line Interface (CLI) 8