BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS



Similar documents
B.D.I. The B.D.I. (Burst Disc Indicator) Alarm System is designed for use with Continental Disc

Sanitary Type Electronic Flow Switches

Electronic Flow Switches

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Scraper Passage Indicator. Electrical Indicator. Features

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

In-Line Electronic Flow Switches

4 Posiflow Proportional Solenoid Valves

Baumann Flexsleev Sanitary Control Valve

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Micro Motion Model D and DL Coriolis Flow and Density Meters

Section: R100 Bulletin: R Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Submersion/Insertion Toroidal Sensor

Model 3051 Pressure Transmitter with HART Protocol

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Baumann Way Bronze or Stainless Steel Control Valve

SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR WARNING VDC

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

B-Series Switches Pressure, Differential Pressure & Hydraulic

In-Line Electronic Flow Switches

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Self-operated Temperature Regulators Temperature Regulator Type 1u

Typical Aluminum GFM Mass Flow Meter

Plastic tube flowmeters Series PT/PS

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

AP/UP, AP/MIL Series. Magnetic Circuit Protectors

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Cable Plug acc. to DIN EN , Form A

for ALL your Rupture Disk needs...

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

SITRANS F flowmeters SITRANS F M

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

PRODUCT PROFILE FEATURES

SQUARE D INDUSTRIAL CONTROL PRODUCTS

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

AlarmLine Addressable Linear Heat Detector

Advantium 2 Plus Alarm

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

General Purpose ph/orp Sensors

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

ALARMLINE ANALOGUE Linear Heat Detection System

WD-AMX Water Detection Controllers

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

2.12. page Products for Explosion hazardous Environment

Thermatel Model TA1 Mass Flow Transmitter

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

Automatic Self-Cleaning Strainers

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Pressure Switch for gas and air

Fisher 646 Electro Pneumatic Transducer

The Unique Accelabar Flow Meter

Compact pressure switch Flameproof enclosure Ex d Model PCA

Model 111 Mass Flow Instruments

Flow switches Series AD/VH

Technical Data. Installation

Model TJE. Precision Gage/Absolute Pressure Transducer DESCRIPTION FEATURES

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

Solenoid Valve Island Type 3965

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Conductive Level Switch FK 2 Technical Data:

Quick Connect Boxes Inside Gloveboxes

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

OPTIMASS 6000 Technical Datasheet

Liquid Level Limit Switch liquiphant T FTL 20

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

Assisted lift operated 2/2-way solenoid valves Type EV250B

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

FlowPak TM General Application Valve 1/2-4, Class 150

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

VSO MAX HP High Flow Proportional Valve

Rosemount 333 HART Tri-Loop

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

Baumann Little Scotty Bronze Control Valve

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Mono-Block II Installation & Operation Manual

kymanual or Automatic - it s your Choice

Worcester DS/DM Series UltraSwitch Switch box

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

Electronic Wallmount Faucet 1500T4 & 1501T4 Series

SELECTION, APPLICATION AND MAINTENANCE

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

B-Series Temperature Switches

Baumann Mikroseal Control Valve

Installing a Probe. Typical Installation

MFP14, MFP14S and MFP14SS Automatic Pumps

Transcription:

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief device, burst indication is used to provide instantaneous notification of rupture disc activation. When rupture discs are used in conjunction with pressure relief valves, they remove valves from contact with harsh process conditions and helps prevent fugitive emissions. In this application, the ASME code, Section VIII, Div. 1, requires that the space between the disk and the valve must be provided with a suitable telltale assembly capable of detecting a rupture or pin-hole leak. Depending on the device selected, Fike burst indicators can be used to activate alarms, bells, remote annunciators or interfaced with process control systems, so that appropriate safety follow-up measures can be taken. Fike has a wide range of rupture disc burst indication devices, use this selection guide to determine the best one for your application. Some rupture disc models offer optional integral burst indication that is built into the rupture disc assembly on the downstream side. RUPTURE DISC BURST INDICATOR SELECTION GUIDE BurstCheck BurstCheck Plus BC2 4 BCH Integral Liquid or Gas Service Yes Yes Yes 2 Yes Yes Process Temperature 400 F 400 F 500 F 350 F 450 F 5 Explosion Proof No NEMA 7, 9 No No No Intrinsically Safe Yes 1 N/A Yes 1 Yes 1 Yes 1 Weatherproof NEMA 4 NEMA 4, 7, 9, 13 Yes Yes Yes SRV Isolation 7 Yes Yes No 3 No 3 No 3 Pressure Extremes 2 10 to 1000 psi 10 to 500 psi See Note 6 10 psi minimum See Note 5 Disc Types All All Axius, SRX, SRL, Poly-SD, MRK, HO, P SR-H, Axius SC, SHX, AD-H TC SR-H, Axius SC, AD-H TC, AD-H, Lo-V 1. When properly installed with an appropriate intrinsic barrier and in accordance with local and national electric codes. 2. Pressure limits may be a function of size and media. Consult factory for other pressures. 3. Will not detect pinhole leakage through the disc, not considered a suitable tell-tale indicator when used alone. 4. Consult factory for minimum burst pressures when using graphite rupture discs. 5. Refer to applicable rupture disc model data sheet for limitations. 6. Refer to BC2 table on page 3. 7. Refer to Technical Bulletin TB8105 Form No. R.1.02.01-9 704 S.W. 10th Street P.O. Box 610 Blue Springs, Missouri 64013-0610 U.S.A. (816) 229-3405 www.fike.com Page 1

BURSTCHECK (BC) AND BURSTCHECK PLUS (BCP) BurstCheck and BurstCheck Plus install between a rupture disc and a safety relief valve. They provide positive indication of any pressure build-up due to leakage through the disc, or disc burst due to overpressure. Because their contacts are either normally open or normally closed, BurstCheck and BurstCheck Plus can be wired in a fail-safe configuration for continuous supervision of intact circuitry. BurstCheck is designed as a single unit and incorporates a 1/2 conduit connection. The internal sensor is constructed of 303 stainless steel with a Viton pressure sensing diaphragm. BC burst indicator BurstCheck is suitable for intrinsically safe applications when properly installed with an appropriate intrinsic barrier and in accordance with local and national electric codes. BurstCheck Plus is designed as a single unit and incorporates a 1/2 conduit connection. The hermetically sealed switch is rated for use in hazardous locations. Both units are supplied with a stainless steel pipe nipple for standoff mounting. BURSTCHECK PLUS SPECIFICATIONS Hazardous Area Rating Nema 4, 7, 9, 13 UL/CSA Listed Div. I, Class 1, Groups A, B, C, and D; Class II, Groups E, F, and G SPDT Hermetically sealed Contact Electrical Rating 120 VAC + 10% @ 11 amperes resistive load 30 VDC + 10% @ 5 amperes resistive load Seal Switch hermetically sealed from process Environmentally sealed NEMA 4, 7, 9, 13 Wetted parts: 316 SST, Viton Activation Pressure Set point @ 6 PSIG/.41 BARG Max. Operating Pressure 500 PSIG/34 BARG Housing Proof Pressure 750 PSIG/51 BARG -40 to 400 o F (-40 to 204 o C) Ambient Temperature Range -30 to 160 o F (-34 to 71 o C) Installation 1/4 NPT (male) BURSTCHECK SPECIFICATIONS SPDT Contact Electrical Rating 120 VAC @ 5A The BC is intrinsically safe for Class I, Groups A, B, C, and D when connected through a CSA certified shunt diode safety barrier. Intrinsic Safety Barrier available from Fike, P/N 02-8353. Seal Environmentally sealed (NEMA 4) High impact plastic 303 SST wetted parts Viton diaphragm Activation Pressure Set point @ 6 PSIG/.41 BAR Housing Proof Pressure 1000 PSI/68.95 BAR 0 to 400 o F (-18 to 204 o C) Ambient Temperature Range 0 to 165 o F (-18 to 74 o C) Installation 1/4 NPT (male) Page 2

BURSTCHECK 2 (BC2) The BC2 is a rupture disc burst indicator that uses a break in electrical continuity to signal the burst of a rupture disc. The indicator consists of a insulated flex-circuit and may have a fluoropolymer diaphragm or actuator strip mounted across a ring with integral gaskets. Upon disc rupture, the BC2 s thin fluoropolymer diaphragm or Actuator Strip acts upon the flexible circuit causing the circuit to be physically broken. This open circuit condition can be used to activate alarms, bells, remote annunciators or interfaced with process control systems. This provides process operators with immediate annunciation of an overpressure event so that appropriate measures can be taken. The circuit conductive loop is protected with Kapton, providing excellent corrosion resistance. NOTE: While similar in appearance, the BC2 is not a rupture disc and cannot be used as such. There should be no pressure differential across the BC2. BC2 burst indicator BC2 SPECIFICATIONS Disc Compatability Axius, SRX, SRL, Poly-SD, MRK, HO, P Sizes 1/2 thru 24 ANSI, DIN, JIS, etc. Normally closed The BC2 is intrinsically safe for Class I, Groups A, B, C, and D when connected through a CSA certified shunt diode safety barrier. Maximum resistance across the circuit prior to rupture is 2.0 OHMS. Barrier available from Fike, P/N 02-8353. Electrical Rating 24 VAC/DC @ 50mA Indicator circuit: Copper foil laminated between Kapton Membrane: PFA fluoropolymer with Nylon connector (2 & 3 )PTFE Fluoropolymer with Nylon connector (4 and up) Support Frame: 316 SSTGasket: Compressed arimide fiber in nitrile binder -40 to 500 F (-40 to 260C) -40 to 165 F (-40 to 74 C) Wiring Two conductor 20 AWG with shield and 20 AWG drain Blue PFA jacket The BC2 comes with 18 of 20 AWG cable equipped with a 3 pin quick disconnect weatherproof receptacle. A lead cable can be purchased in lengths of 10 (Fike P/N D3513-115-10) and 25 (Fike P/N D3513-115-25) with quick disconnect plug to connect to customer monitoring systems. CSA certified Directive 94/9/EC Corresponding Rupture Disc Minimum Burst Pressures Nominal Size PSIG (BARG) 1/2 (DN15) 36 (2.48) 3/4 (DN20) 34 (2.34) 1 (DN25) 10 (.69) 1 1/2 (DN40) 8 (.55) 2 (DN50) 8 (.55) 3 (DN75) 7 (.48) 4 (DN100) 7 (.48) 6 (DN150) 6 (.41) 8 (DN200) 4.5 (.31) 10 (DN250) 3.6 (.25) 12 (DN300) 3 (.21) 14 (DN350) 2.6 (.18) 16 (DN400) 2.3 (.16) 18 (DN450) 2 (.14) 20 (DN500) 1.8 (.12) 24 (DN600) 1.5 (.10) Note: Any application where the burst pressure falls below the values on this table will need to be evaluated by Fike Page 3

BURSTCHECK HYGENIC (BCH) The BCH Burst Indicator is specifically designed for use with standard Tri-Clover ferrules and clamps. It provides instantaneous notification of rupture disc activation. The indicator consists of a insulated flex-circuit and may have a fluoropolymer diaphragm or actuator strip mounted across a ring with a selected gasket. Upon disc rupture, the BC2 s thin fluoropolymer diaphragm or Actuator Strip acts upon the flexible circuit causing the circuit to be physically broken. This open circuit condition can be used to activate alarms, bells, remote annunciators or interfaced with process control systems. This provides process operators with immediate annunciation of an overpressure event so that appropriate measures can be taken. The circuit conductive loop is protected with Kapton, providing excellent corrosion resistance. The flexible circuit is physically attached at two locations and is broken in a predetermined pattern. This eliminates the possibility of the conductive loop remaining intact after disc rupture. BCH burst indicator The BCH is installed downstream of the rupture disc. NOTE: While similar in appearance, the BCH is not a rupture disc and cannot be used as such. There should be no pressure differential across the BCH. SPECIFICATIONS Disc Compatibility SR-H, Axius SC, SHX The BCH is intrinsically safe for Class I, Groups A, B, C, and D when connected through a CSA certified shunt diode safety barrier at levels of 50 ma @ 24 VAC/DC. Maximum resistance across the circuit prior to rupture is 1.0 OHMS. An intrinsic Safety Barrier is available from Fike, P/N 02-8353. -40 to 350 o F (-40 to 177 o C) -40 to 165 o F (-40 to 74 o C) Gasket Temperature Range *EPDM: -40 to 300 o F (-40 to 149 o C) *Silicone: -40 to 450 o F (-40 to 232 o C) *Viton, *PTFE fluoropolymer: -20 to 450 o F (-28 to 232 o C) Note: * USP Class 6 Schematic of BCH with rupture disc The BCH comes with 18 of 20 AWG cable equipped with a 3 pin quick disconnect weatherproof receptacle. A lead cable (P/N D3515-115-X) can be purchased in lengths of 10 and 25 with a quick disconnect plug to connect to customer monitoring systems. Indicator circuit: Copper foil laminated between Kapton Membrane: PTFE fluoropolymer CSA Certified Directive 94/9/EC Page 4

INTEGRAL BURST INDICATOR The integral burst indicator is built directly into the rupture disc assembly on the downstream side and provides instantaneous notification of rupture disc activation. The indicator consists of a insulated flex-circuit actuator strip mounted across the disc ring with a selected gasket. Upon disc rupture, the normally closed circuit is physically broken. This open circuit condition can be used to activate alarms, bells, remote annunciators or interfaced with process control systems and provides process operators with immediate annunciation of an overpressure event so that appropriate measures can be taken. The circuit conductive loop is protected with Kapton, providing excellent corrosion resistance. The flexible circuit is physically attached at two locations and is broken in a predetermined pattern. This eliminates the possibility of the conductive loop remaining intact after disc rupture. Axius SC with burst indicator SPECIFICATIONS Integral Burst Indicator (BI) Rupture Disc Option for the following models: SR-H, Axius SC, Lo-V, AD-H-TC The Integral BI is intrinsically safe for Class I, Groups A, B, C, and D when connected through a CSA certified shunt diode safety barrier at levels of 50 ma @ 24 VAC/DC. Maximum resistance across the circuit prior to rupture is 1.0 OHMS. An intrinsic Safety Barrier is available from Fike, P/N 02-8353. s -40 F to 450 F (-40 C to 232 C) The Integral BI comes with 18 of 20 AWG cable equipped with a 3 pin quick disconnect weatherproof receptacle. A lead cable (P/N D3515-115-X) can be purchased in lengths of 10 and 25 with a quick disconnect plug to connect to customermonitoring systems. Burst Indicator Indicator circuit: Copper foil laminated between Kapton CSA Certified -40 F to 165 F (-40 C to 74 C) Temperature limits may be further restricted by specific disc model/ material selections R Copyright Fike Corporation All Rights Reserved. Form No. R.1.02.01-9 January, 2012 Specifi cations are subject to change without notice. BurstCheck, BurstCheck Plus, BCH, and BC2 are trademarks of Fike Corporation. Kapton is a registered trademark of DuPont Corporation. All other product names are trademarks of their respective owners Page 5