HVAC Efficiency Definitions



Similar documents
Glossary of Heating, Ventilation and Air Conditioning Terms

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Creating Efficient HVAC Systems

ENERGY STAR Program Requirements for Residential Air Source Heat Pump (ASHPs) and Central Air Conditioner Equipment. Partner Commitments.

Heating, Ventilation & Air Conditioning Equipment

CHILLER PLANT CONTROL MULTIPLE CHILLER CONTROLS

Appendix C. Minimum Equipment Efficiency Standards

Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Chapter 3.4: HVAC & Refrigeration System

Lower Energy Costs with Rooftop Air-Conditioning Package Units

SECTION HEAT PUMPS

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

Understanding Heating Seasonal Performance Factors for Heat Pumps

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

How To Design A Building In New Delhi

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

WORKING DOCUMENT ON. Possible requirements for air heating products, cooling products and high temperature process chillers TRANSITIONAL METHODS

HVAC Basic Science - System Capacity

Heating, Ventilation & Air Conditioning Equipment

How To Buy A Lennox Power System

Rating Water-Source Heat Pumps Using ARI Standard 320 and ISO Standard

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application

Air-Conditioning Buying Guide

Poor Performing AC? High Electric Bills? High Humidity?

Achieving ENERGY EFFICIENCY with Standard Air-Conditioning Units. Mike West, PhD, PE Advantek Consulting, Inc

ZUBA-CENTRALTM. Heating & Cooling. Evolved. HEATING AND AIR CONDITIONING FOR WHOLE-HOME, YEAR-ROUND COMFORT

3/29/2012 INTRODUCTION HVAC BASICS

RESEARCH HIGHLIGHT. Performance Assessment of a Cold-Climate Air Source Heat Pump

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Energy Efficiency. Energy Efficient Home Cooling:

Regency TAFE, SA. An evaluation of the effects of PermaFrost treatment on a Fujitsu Heat Pump. July Prepared by

Heating & Cooling Efficiency

The Second Law of Thermodynamics

How To Save Energy With High Pressure Control

By Tom Brooke PE, CEM

HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems

2010 Duct-Free Splits Line Card

Development and testing of a multi-type air conditioner without using AC inverters

Laboratory Test Report for Fujitsu 12RLS and Mitsubishi FE12NA Mini-Split Heat Pumps

Energy savings in commercial refrigeration. Low pressure control

Ductless Heat Pumps. Gary Nordeen January

Dr. Michael K. West, PE 1 Dr. Richard S. Combes, PE 2 Advantek Consulting / Melbourne, Florida

Massachusetts COOL SMART. RESIDENTIAL CENTRAL AC/DUCTED AIR SOURCE HEAT PUMP Rebate Application

New energy evaluating methodology of Air conditioner and Heat pump

Optimization of Water - Cooled Chiller Cooling Tower Combinations

Strategy Guideline: HVAC Equipment Sizing

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

Economic Evaluation of Residential Air Conditioner Designs for Hot and Dry Climates

Laboratory Performance Testing of Residential Window Mounted Air Conditioners

Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications

The Development of a Frost-Less Heat Pump

Large Energy Savings Per Installation VFDs for Large Chillers

Improving Data Center Energy Efficiency Through Environmental Optimization

5.6 Technical Specification: Premium Efficiency Electric Air Conditioning Equipment

Schedule 3(A) Room Air Conditioners

AHRI Standard 325 (Formerly ARI Standard 325) 1998 Standard for Ground Water-Source Heat Pumps

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

SASO 2663 :2014 ENERGY LABELLING AND MINIMUM ENERGY PERFORMANCE REQUIREMENTS FOR AIR-CONDITIONERS

EFFECTS OF INDOOR RELATIVE HUMIDITY ON REFRIGERATED DISPLAY CASE PERFORMANCE

SIMULATION OF RADIANT COOLING PERFORMANCE WITH

The ASHRAE HQ Building Can the energy efficiency of the different mechanical systems really be compared? RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL

A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures

Florida Power & Light Company. Business Heating Ventilation & Air Conditioning ( HVAC ) Program Standards. Effective: November 9, 2015

Preventive Maintenance Strategies and Technologies Can Pave the Path for Next Generation Rooftop HVAC systems

A Glossary of HVAC Terms:

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

HVAC Systems: Overview

Analysis of data centre cooling energy efficiency

HEAT PUMPING AND REVERSIBLE AIR CONDITIONING; RETROFIT OPPORTUNITIES IN A LABORATORY BUILDING. Campus du Sart Tilman, B49, B-4000 Liège, Belgium

york air-conditioning products Residential & VRF News 2015

Performance 17 Two-Stage Air Conditioner with Puron Refrigerant

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

AND SIMPLE HVAC SYSTEMS

Energy Efficiency in Industrial HVAC Systems

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

Evaporative Cooling for Residential and Light-Commercial

1 Project Information. 2 Building Type. 3 Trade Ally/Contractor Information. Appalachian Power Commercial Program HVAC and VFD Rebate Worksheet

The Seasonal Efficiency of Multi-Boiler and Multi-Chiller Installations

Tech Byte 27: Small Computer Room and IT Closet Cooling

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Research on the Air Conditioning Water Heater System

FTQ. Daikin Inverter Ducted Heat Pump

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

Introduction. Motor Types

Calculating System Flow Requirements

Optimization of combined heating and cooling in Supermarkets

Smart School Symposium Heating Ventilation and Air Conditioning Session HVAC Products. Richard Lord

Defining Quality. Building Comfort. Precision. Air Conditioning

HEAT RECOVERY FROM CHILLED WATER SYSTEMS. Applications for Heat Reclaim Chillers

Theoretical Study on Separate Sensible and Latent Cooling Air-Conditioning System

Hybrid (Dual Fuel) - Gas Heat and Air Source Heat Pump

Transcription:

HVAC Efficiency Definitions Term page EER - 2 SEER - 3 COP - 4 HSPF - 5 IPLV - 6 John Mix May 2006 Carrier Corporation 1

Energy Efficiency Ratio (EER) The energy efficiency ratio is used to evaluate the equipment s efficiency while in the cooling mode. EER is defined as the net cooling capacity (in Btuh) divided by the total electrical power input (in watts), as shown in EQ 1. EER is calculated at a single very specific operating point and is typically only applied for commercial equipment > 6 nominal tons. EER = NetCapacity( Btuh) PowerInput( kw ) (see supplemental equations EQ 3-6) For applicable units, manufacturers must rate their units per the ARI defined operating conditions. This must officially be determined EER from actual laboratory test measurements, and results in an EER ARI. The ARI defined EER conditions are: Evaporator Entering Air (EAT) = 80/67 o F Ambient air (condenser air) = 95 o F Specific static pressure requirements that vary with the tonnage. No outside ventilation air is specified. No specific indoor airflow rate. However, the same equation can be applied at any other specific operating condition. In this case the resulting value is an application specific EER value, or EER App. Care must be taken not to confuse the two any application specific conditions which incur a larger load on the unit than what the ARI conditions impose, will result in a lower energy efficiency ratio value. Since the value for EER is expressed in Btuh/watts, it is not dimensionless, and is an efficiency ratio not a value of efficiency. Since the units are typically not mentioned when quoting EER values, it is important not to interpret this as a percentage or actual efficiency. For example, a 9.7 EER value does not meant that the unit is 9.7% efficient. In order to obtain an actual value for efficiency, the units must be converted so they are similar terms in both the numerator and denominator. For example, if a unit produces 220,000 Btuh of cooling with 22 kw of power input: ex: % Energy Efficiency = 220,000Btuh 22,000( watts) x3.414( Btuh / watt) EQ-1 =2.9 % EQ-2 This means that for every Btuh of electrical energy supplied, 2.9 Btuh of heat can be absorbed. The EER rating evaluates how a unit will perform at one specific point. A higher value for EER represents a higher efficiency at standard conditions. Net Capacity = Gross Capacity indoor fan motor heat Bhp 746( watts / Bhp) Indoor fan motor heat = x(3.414btuh / watt) motor _ efficiency EQ-3 EQ-4 Total Power Input = compressor watts + Indoor fan motor watts + condenser fan motor watts EQ-5 actual _ power( Bhp) x746( watts / Bhp) Fan motor input (watts) = x( number _ of _ fans) motor _ efficiency EQ-6 2

Seasonal Energy Efficiency Ratio (SEER) The Seasonal Energy Efficiency Ratio is similar to the EER in that its purpose is to represent the efficiency of the unit while in the cooling mode. However, there are two major differences between them. First, the SEER attempts to take into account the energy consumption due to the cycling of the fan motors and compressors. Second, EER is calculated only at one point (the ARI standard conditions) where SEER is calculated at two different points that simulate operation at higher and lower humidity levels for entering conditions. According to the industry definition, the SEER rating is only defined for units 5 tons and less that operate on single phase current. Nonetheless, it is industry convention to apply the SEER rating to single and three phase equipment that are < 5 tons. Also, just like an EER App the SEER formula is sometimes calculated for larger equipment. The SEER calculation requires performance testing and measurements at two different points, as outlined below. The first point is intended to simulate dry coil conditions and is evaporator entering air (EAT) of 80/57 o F and ambient air of 82 o F. The unit is operated at this point and performance measurements are taken. Next, the unit is cycled on and off and power measurements are taken. Then, the same procedure is done at EAT = 80/67 o F with 82 o F ambient, to simulate wet coil conditions. Calculating SEER involves laboratory testing, in a similar manner to all other rating values, with the exception that SEER requires power measurements to be recorded while the unit is in steady state operation, upon start-up and while the unit is at rest (there can still be some amp draw even while the compressors are not running due to potential operation of the fan motor, crankcase heaters, etc). SEER is impossible to calculate without a considerable amount of specific test data. Similarly to EER, the SEER is not a dimensionless value, but is always quoted as a pure number (i.e. no units). SEER weighted average of EER values at all four measurement conditions EQ-7 Many times people try to derive the SEER value from the EER value. However, this is impossible without laboratory test data. To do so requires calculating of a Degredation Factor ( C D as shown in EQ 8), which can only be determine from laboratory testing at the various SEER defined operating conditions. SEER = EER ( 1 C D /2 ) where C D = the Degredation Factor EQ-8 The SEER evaluates a unit s performance under two different conditions ; high and low humidity with less than design ambient conditions. A higher value of SEER represents a higher cooling efficiency. 3

Coefficient of Performance (COP) The coefficient of performance is used to measure the unit s efficiency while in the heating mode and is applied to heat pumps, of any nominal cooling capacity, that operates on three phase current. To evaluate a heat pump s efficiency while in cooling mode, EER or SEER must be used. The COP is a dimensionless value defined as the energy produced by the heat pump (in watts) divided by the energy consumed by the heat pump (in watts). In an air to air heat pump, the evaporating refrigerant moves heat from the outside air (when in heating mode) and this heat plus the heat equivalent of the work of compression is rejected to the recirculated air flowing over the condenser coil and to the space to be heated. There is always heat energy in the outside air, however, at lower temperatures, it becomes more difficult to extract. Therefore the COP decreases at lower ambient and the ARI COP rating is calculated at two different ambient temperatures (47 o F and 17 o F). The formula for calculating COP is shown below in EQ 9. Net Capacity (watts) (Gross Cooling capacity) (Supply fan heat) COP = = EQ-9 Power Input (watts) supply fan + compressor(s) + condenser fan(s) Thus, a heat pump with a COP = 2.5 would produce two and a half times as much heat than the heat equivalent of the watts input. If electrical resistance heat is used to condition the space, it is by definition, 100% efficient. In this case only 1 watt of heat would be obtained for every watt input, and the resulting COP would be equal to 1. COP represents the efficiency of a heat pump while in the heating mode. A higher value of COP reflects a higher heating efficiency. 4

Heating Seasonal Performance Factor (HSPF) The Heating Seasonal Performance Factor is used to measure a unit s efficiency while in the heating mode and applies only to heatpumps. It is defined as the total heating output (including supplementary electric heat) divided by the total electric power necessary to maintain building heating requirements for its normal annual usage period. The units are Btuh divided by Watt-hours for the same period. The HSPF is only applied to heat pumps (in heating mode) that operate on single phase current and have a nominal cooling capacity of less than 5.5 tons. Since HSPF represents a seasonally corrected heating efficiency, the first step in the calculation involves the hours of operation for different geographic locations and different modes of operation. To accomplish this, the country has been broken up into different regions reflecting the amount of time spent in a particular mode of operation. The heating regions map is shown in Figure 1, and a similar map exists that represents hours spent in cooling mode. By factoring in the total hours of operation in each mode, as well as the design conditions for each area, the HSPF can be calculated using EQ-10. HSPF = (total heating output during normal usage period) (total electric power input during normal usage period) EQ-10 Fig. 1 HSPF Heating Zones 5

Integrated Part Load Value (IPLV) The Integrated Part Load Value was developed to evaluate the equipment s energy consumption in the cooling mode while it is operating at less than full capacity. The IPLV can essentially be described as a weighted average of the energy efficiency ration (EER) calculated at each stage of unloading at which the unit can operate. Thus, the IPLV is similar to EER and SEER in that all three are intended to represent the unit s cooling efficiency. The significant difference between them is that the EER is calculated at one very specific point while IPLV is calculated over the unit s entire range of unloading operation. One major difference between the SEER and IPLV values is that SEER takes into account the cycling of the equipment, but does not actually unload the compressors like IPLV does. The IPLV can be of significant importance since a unit typically operates at full capacity only a small fraction of the time it is in use. In order to properly integrate IPLV, it is important to understand how the value is calculated. IPLV is a function of two independent variables; Part-Load-EER and the Part-Load-Factor (PLF). IPLV is mathematically represented by the formula shown in EQ-11 and EQ-12. PLF = A0 + (A1 x Q) + (A2 x Q 2 ) + (A3 x Q 3 ) +(A4 x Q 4 ) + (A5 x Q 5 ) + (A6 x Q 6 ) Where: Q = % of full-load capacity at part-load rating conditions A0 through A6 are constants given by the part-load curve IPLV = (PLF 1 PLF 2 )[(EER 1 + EER 2 )/2] EQ-12 EQ-11 + (PLF 2 PLF 3 )[(EER 2 + EER 3 )/2] + (PLF n-1 PLF n )[(EER n-1 + EER n )/2] + (PLF n )(EER n ) Where: PLF = Part Load Factor from EQ-12 n = total number of capacity steps subscript 1 = 100% capacity and EER at part-load conditions subscript 2 through n = Specific capacity steps Since the IPLV is a function of the PLF, it is important that the PLF curve is representative of how the unit will actually perform. Otherwise, the IPLV value is meaningless. See Figure 2. Note that at at ~ 80% of full load, the PLF is nearly equal to 1.0, while at ~ 20% of full load, the PLF is only equal to ~ 0.07. Thus, the PLF is a value that represents the percentage of the time a unit typically spends operating at a given step of capacity. The exact values of the PLF greatly determine the single IPLV value. Also, the EER value for each step of capacity is dependent on the load that is on the unit. The summation of all these values (as shown in EQ-11) yields the single IPLV value that is published. 1 0 Figure 2 A unit that has few steps of unloading will have a higher Part Load Factor (which results in a higher IPLV, all other factors being equal) than one that has many steps of unloading. This is true regardless of whether or not the unit ever uses these steps of unloading. A higher IPLV does not mean that the unit is 6

more energy efficient. It is important to recognized that more stages of unloading will result in a lower IPLV which means it is more closely matched to the cooling load, will result in less over-cooling of the conditioned space, and better humidity control. Additionally, more stages of unloading will result in less cycling of the equipment. Continuous cycling of the equipment will typically lead to premature wear and excessive current draw on start-up. Therefore, a unit with a lower IPLV is usually preferable unless the unit will always operate near its full load value 100% of the time. IPLV represents the cooling efficiency of a unit operating over its entire range of unloading. Unless the unit will operate at or near its full load value 100% of the time, a lower IPLV is more desirable for better overall performance. NOTE: As of the date of this document, the current IPLV methodology is flawed because it does not properly represent all the aspects of part load. ARI has defined a new procedure that is predicted to be released in 2006. The levels will be about the same, but will also show credit for variable speed fans and other part load improvements that the prior procedure does not properly consider. 7