Agilent 5500 AFM. Data Sheet. Features and Benefits



Similar documents
Keysight Technologies How to Choose your MAC Lever. Technical Overview

Agilent 4339B/4349B High Resistance Meters

Agilent Television Power Consumption Testing. Application Note

Agilent 4338B Milliohm Meter

Nano-Spectroscopy. Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale

Nanotribology of Hard Thin Film Coatings: A Case Study Using the G200 Nanoindenter

Pore size and BET surface area. analysis at your fingertips. SA Gas Adsorption Analyzer

The Next Generation in Automated Oscilloscope Test

STM and AFM Tutorial. Katie Mitchell January 20, 2010

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

Scanning Probe Microscopy

Agilent Automotive Power Window Regulator Testing. Application Note

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract

Agilent E5063A ENA Series Network Analyzer

Lecture 4 Scanning Probe Microscopy (SPM)

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

Agilent OSS access7 Signaling Meter

Agilent 87421A/87422A Power Supply

Piezoelectric Scanners

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

PXI and AXIe Modular Instrumentation

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

Accuracy counts! SENSORS WITH ANALOG OUTPUT

Image Lab Software for the GS-900 Densitometer

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

PXI and AXIe Modular Instrumentation

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

Agilent E6832A W-CDMA Calibration Application

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

Make Better RMS Measurements with Your DMM

Agilent U2000 Series USB Power Sensors

Supplies 1. Toner cartridges. Printing. Using color. Paper handling. Maintenance. Troubleshooting. Administration. Index

PCI Express 1.0 (2.5 GT/s) Protocol Test

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Agilent U2000 Series USB Power Sensors

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

1 Introduction. 1.1 Historical Perspective

Force Spectroscopy with the Atomic Force Microscope

h e l p s y o u C O N T R O L

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

A METHOD OF PRECISE CALIBRATION FOR PIEZOELECTRICAL ACTUATORS

Computer Specifications

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

802.11ac Power Measurement and Timing Analysis

Agilent 8762/3/4A,B,C Coaxial Switches

Report on Government Information Requests

High-Speed Inter Connect (HSIC) Solution

Agilent P940xA/C Solid State PIN Diode Switches

Pall in the Brewery (more value per hectolitre) DE Free Clarification FB1795

ATOMIC FORCE MICROSCOPY

WATERS QUANTITATIVE ANALYSIS solutions

Evaluating Oscilloscope Bandwidths for Your Application

AN2604 Application note

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

ProteinChip Energy Absorbing Molecules (EAM)

WD Hard Drive Interface Guide

How does a venture capitalist appraise investment opportunities?

Leica DFC450 & DFC450 C. Digital Microscope Cameras for Analysis and Documentation

Keysight N6854A Geolocation System. Configuration Guide

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens

Cisco 2-Port OC-3/STM-1 Packet-over-SONET Port Adapter

INTRODUCTION TO SCANNING TUNNELING MICROSCOPY

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

Keysight Technologies Quickly Identify and Characterize Thermal Measurement Points

Achieving Functional Safety with Global Resources and Market Reach

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

Agilent U2000 Series USB Power Sensors

Agilent FieldFox Remote Viewer

amplification tech Optical Design of CFX96 Real-Time PCR Detection System Eliminates the Requirement of a Passive Reference Dye

Living up to Life. Leica LAS Live Image Builder Dynamic Software for Fast Widefield Imaging and Extended Depth of Focus

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS

Surface Analysis with STM and AFM

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software

[ Care and Use Manual ]

10 Reasons to Choose Image-based ID Readers. White Paper

Calibration of AFM with virtual standards; robust, versatile and accurate. Richard Koops VSL Dutch Metrology Institute Delft

Fundamentals of Mass Flow Control

White Paper. 10 Reasons to Choose Image-based Barcode Readers

HSeries. High Power High Quality. Ultra-High Speed, Sensing Ionizer SJ-H Series

Exceptional Accuracy and Durability for Tough Industrial Environments INDUSTRIAL FLOOR SCALES. VERTEX Industrial Floor Scales Heavy-Duty Design

AT-S39 Version 1.3 Management Software for the AT-8024 and AT-8024GB Fast Ethernet Switches. Software Release Notes

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Thermo Scientific Compound Discoverer Software. A New Generation. of integrated solutions for small molecule structure ID

Barcode Labeling in the Lab Closing the Loop of Patient Safety

Motion and Positioning

Atomic Force Microscopy Observation and Characterization of a CD Stamper, Lycopodium Spores, and Step-Height Standard Diffraction Grating

Agilent Infoline Web Services. Quick Reference Guide. Scan and use your phone to go to Infoline at

Who We Are. Denis Thiery Chairman and Chief Executive Officer

Agilent EEsof EDA.

Application Note. Double click System tray icon after service started. Click start/continue button

product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology

The Lawson Customer Relationship Management Solution

1 st Edition Nanotechnology Measurement Handbook A Guide to Electrical Measurements for Nanoscience Applications

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

Updating the QIAcube operating software

Transcription:

Agilent 5500 AFM Data Sheet Figure 1. STM image of HOPG showing atomic structure. Scan size: 4 nm. Features and Benefits Exceptional environmental and temperature control Superior scanning in fluids, gases, or ambient conditions High precision AFM delivers atomic resolution The utmost flexibility from a highly modular system Convenient vertical sample approach Applications Electrochemistry Life science Materials science Polymer science Electrical characterization Nanolithography Nanografting Biotechnology Overview The Agilent 5500 is the ideal multiple-user research system for atomic force microscopy. As the high-performance flagship of Agilent s AFM instrument line, the 5500 provides atomic-scale resolution and a wealth of unique technological features, including patented top-down scanning, ultra-precision temperature control, and industry-leading environmental control. It is well suited for life science, materials science, polymer science, electrical characterization, and nanolithography applications. The intelligent, modular design of the 5500 permits the simple integration of an inverted optical microscope, numerous imaging modes, customizable sample-handling plates, an electrochemistry kit, and a video microscope. In short, the versatile 5500 has been engineered to support almost every scientific AFM capability offered by Agilent Technologies.

Scanners Agilent s open- and closed-loop scanners (two ranges available: 90µm x 90µm, or 9µm x 9µm) offer outstanding linearity, accuracy, versatility, and ease of use. These multipurpose, top-down scanners are ideal for imaging in fluids or air and under controlled temperature and environmental conditions. To deliver high-resolution imaging results, a balanced-pendulum design is utilized that eliminates artifacts in the image by keeping the relative position of the laser spot fixed in relation to the cantilever throughout the scan cycle. MAC Mode Agilent s patented MAC Mode provides the industry s best performance for imaging in fluids and imaging soft samples, allowing researchers to image submolecular structures that cannot be resolved with any other AFM technique. MAC Mode is particularly useful in application areas that require high resolution and force sensitivity, such as biology, polymers, and surface science. AAC mode is included with MAC Mode. STM scanners (9µm x 9µm, or 1µm x 1µm) are also available for use with the 5500. Agilent s STM scanners deliver excellent results on a variety of conducting materials. These low-current and ultra-lowcurrent STM scanners provide stable imaging at pico-ampere and sub-pico-ampere currents to resolve individual atoms and molecules. STM scanners take advantage of the extreme distance sensitivity of the tunneling current between two conducting electrodes. By measuring the tunnel-current variations as a probe is scanned over a sample s surface, STM is able to deliver the highest-resolution SPM images. Open access to the scanner and easy alignment of optics help simplify use of the 5500. In addition, easy-to-load scanner nose cones make switching imaging modes quick and convenient. The nose cones are made from PEEK polymers, have low chemical reactivity, and can be used in a wide range of solvents. Their easy interchangeability provides tremendous flexibility. Figure 2. AFM images of normal alkanes on graphite obtained in amplitude modulation mode. 2

MAC Mode III Patented MAC Mode III provides three user-configurable lock-in amplifiers, affording researchers virtually limitless application possibilities and unprecedented speed. It also provides two expansion slots. MAC Mode III has been designed to allow single-pass imaging concurrent with KFM/EFM. Simultaneous, high-accuracy topography and surface potential measurements are enabled by a servo-on-height cantilever approach that is not susceptible to scanner drift. KFM/EFM is especially useful for measuring dielectric films, metal surfaces, piezoelectrics, and conductor-insulator transitions. MAC Mode III also lets researchers perform vertical or lateral modulation studies and delivers a unique plot of the oscillating amplitude vs. frequency in contact. This capability allows easy optimization of the detection sensitivity for a broad range of cantilever spring constants. In addition to KFM/EFM and piezo force, MAC Mode III allows the use of higher resonance modes of the cantilever. Higher harmonic imaging provides contrast different from that seen with fundamental amplitude and phase signals. This technique can be utilized to collect additional information about mechanical properties of the sample surface. Temperature Control Agilent s temperature controller uses a patented thermal insulation and compensation design to deliver the industry s most precise temperature control. It allows imaging during temperature changes and is fully compatible with all imaging modes, including those utilized in fluid. The temperature controller s design isolates the sample plate from the rest of the 5500 system. An insulated ceramic fixture protects the surrounding apparatus from the effects of heating or cooling, thus providing the most precise, stable temperature control available. Temperature control is offered with heating up to 250 C and cooling down to -30 C. Figure 3. Topography, surface potential and, dc/dz and dc/dv images of F 12 H 20 adsorbates on Si. The images were obtained in the AM-FM mode. Scan area 300nm. The contrast covers the height and potential changes in the 0 200nm and 0 1V ranges. The contrast of dc/dz maps is in relative units. The images in the columns from top to bottom were obtained respectively at the probe-sample distances of 1nm, 7nm, 15nm, and 30nm. 3

Environmental Control Agilent s industry-leading environmental isolation chamber (EIC) has been specifically designed to meet the many requirements of intricate, demanding atomic force microscopy and scanning probe microscopy research. The EIC mounts directly to the 5500 and provides a sealed sample compartment that is completely isolated from the rest of the system. Eight inlet/outlet ports permit the flow of many different gases into or out of the sample area. Agilent scanners reside outside the EIC, so they are protected from contamination, harsh gases, solvents, caustic liquids, and other damaging experimental conditions. With the EIC, humidity levels can be controlled, oxygen levels monitored and controlled, and reactive gases easily introduced into and purged from the sample chamber. Figure 4. 5500 AFM with environmental chamber. a. b. c. d. Figure 5. Topography images of multiarm star block copolymer macromolecules at low humidity (a), at high humidity (b), at high humidity after 12 hours (c), and at low humidity again (d). Scans are 2 micron. 4

Sample Plates The unique design of Agilent s sample plates delivers superior sample stability and ease of use. Magnetic suspension provides easy loading and eliminates mechanical drift. The stand-alone plates permit simple sample mounting and applicationspecific plate customization. A modular design allows the plates to be used with an unparalleled number of options, such as open liquid cells, flow-through cells, salt-bridge cells (electrochemistry), Petri dishes (live-cell imaging), and glass microscope slides. Figure 6. Sample plates: high temperature plate (left), coverslip and liquid cell plate (middle), Petri dish plate (right). Electrochemical SPM Agilent s electrochemical SPM option includes a complete kit for high-resolution in situ EC-SPM experiments. Electrochemical SPM offers a low-noise potentiostat/ galvanostat for in situ EC-STM and EC-AFM. When combined with temperature control, it is possible to obtain valuable information about electrochemical processes that would otherwise be inaccessible. The addition of environmental control allows imaging with no dissolved oxygen in either aqueous or non-aqueous solutions. a. b. c. d. Figure 7. Corrosion study of a polished metal surface: rest potential (a), after two cycles (b), after three cycles (c), and after six cycles (d). 5

PicoTREC Agilent s exclusive PicoTREC molecular recognition tool kit is designed for use with MAC Mode. The option includes specialized hardware, electronics, consumables, and accessories. With PicoTREC, researchers can quickly distinguish between species that are engaged in molecular binding events and those that are not engaged in molecular binding events, thus eliminating the need to perform slow and tedious force-volume spectroscopy experiments to get the same results. Scientists can use PicoTREC with the 5500 AFM to explore dynamic properties of biological systems (antibody-antigen, ligand-receptor, drug-receptor, DNA-protein, DNA-DNA, and so forth) by imaging patterns of molecular binding and adhesion on surfaces. Topographic Recognition Figure 8. PicoTREC imaging of the micropatterned avidin molecules. Topographic images (above, left), and corresponding recognition images (above, right). Figure 9. Accuracy and reproducibility using PiocTREC anti-his3 on AFM and chromatin on glutaraldehyde mica. PicoTREC can repeat an experiment in a matter of minutes. In the top image blue indicates misses and red indicates false hits. In the bottom image green indicates hits. There was five minutes between scans and number of hits went down on the rescan (96% to 92%) and the false positive rate was 2.8%. Images courtesy of Dr. Stuart Lindsay based on results generated in his lab by Dr. Hongda Wang at ASU. 6

Software The 5500 utilizes Agilent s PicoView, an imaging and analysis software package that offers 3D rendering capabilities. PicoView allows complete control of all scanning parameters and provides the flexibility required for more complex experiments. An integrated script editor and sample scripts are also included. For additional interactive post-processing capabilities, Agilent s easy-to-use Pico Image Basic imaging and analysis software package includes all of the features and functions required to build a basic surface analysis report on multi-layer measurement data that is input from the 5500. The document consists of a set of frames containing surfaces, profiles extracted from surfaces, the results of applying filters and other operators, analytical studies, and 2D and 3D parameters. A measurement identity card, screen notes, and illustrations can be added to each document. Pico Image Advanced and Expert packages are also available. Ultra High Resolution Imaging on the 5500 Figure 10. STM image of C36H 74 alkanes on graphite. Scan size: 8 nm. Figure 11. AFM images of C 18 H 38 and C 390 H 782 lamellae on graphite obtained in the contact mode. The spacings, which are related to the lamellae and individual chains, are distinguished in the image of C 18 H 38 lamellae (left). The zigzag pattern along the closely packed alkane chains is seen in the image of the ultra long alkane C 390 H 782 (right). The Agilent 5500 not only provides the researcher flexibility and modularity but also the highest imaging resolution. The 5500 has excellent signal-to-noise characteristics, low thermal drift and excellent control of the tip-sample forces. Figures 9-11 are just a few of the sub-100nm features seen in a variety of polymers. Figure 12. AFM images of C 242 H 486 lamellae on graphite obtained in the contact mode. Several slightly twisted lamellae were detected in the images of C242H486, A number of linear defects caused by the missing chains or their parts are also distinguished in the100nm image (left). The individual alkane chains, which are extended betweenthe edges of the lamellae, are also noticed in the 55nm image (right). 7

Specifications Scanners Note: Specifications shown are for open-loop operation. Closed-loop scanners are also available. Large Multi-Purpose Scanner Scanning Range 90µm x 90µm Z Range 8µm Vertical Noise Small Scanner 0.5ÅRMS Scanning Range 9µm x 9µm Z Range 2µm Vertical Noise Sample Plate Sizes Optics Vibration Isolation Controller Input Drive Output Interface Power Facilities Specifications Acoustic Noise Temperature Variation Humidity Variation <0.2ÅRMS Kinematic mount translatable plate Navitar video camera Available Ten 16-bit channels 5 channels ± 215 V, 24-bits Four 24-bit channels, ± 10V USB 100-120VAC or 220-240VAC 1A; 50-60Hz <75 dbc Does not exceed ± 2 F Does not exceed ± 20% RH AFM Instrumentation from Agilent Technologies Agilent Technologies offers high-precision, modular AFM solutions for research, industry, and education. Exceptional worldwide support is provided by experienced application scientists and technical service personnel. Agilent s leading-edge R&D laboratories are dedicated to the timely introduction and optimization of innovative and easy-to-use AFM technologies. www.agilent.com/find/afm Americas Canada (877) 894 4414 Latin America 305 269 7500 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Thailand 1 800 226 008 Europe & Middle East Austria 43 (0) 1 360 277 1571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2013 Printed in USA, January 10, 2013 5989-6405EN RevB